Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software Certification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

114 records · Page 7

Modeling the direct sun component in buildings using matrix algebraic approaches: Methods and validation

Simulation tools that enable annual energy performance analysis of optically-complex fenestration systems have been widely adopted by the building industry for use in building design, code development, and the development of rating and certification programs for commercially-available shading and daylighting products. The tools rely on a three-phase matrix operation to compute solar heat gains, using as input low-resolution bidirectional scattering distribution function (BSDF) data (10–15° angular resolution; BSDF data define the angle-dependent behavior of light-scattering materials and systems). Measurement standards and product libraries for BSDF data are undergoing development to support solar heat gain calculations. Simulation of other metrics such as discomfort glare, annual solar exposure, and potentially thermal discomfort, however, require algorithms and BSDF input data that more accurately model the spatial distribution of transmitted and reflected irradiance or illuminance from the sun (0.5° resolution). This study describes such algorithms and input data, then validates the tools (i.e., an interpolation tool for measured BSDF data and the five-phase method) through comparisons with ray-tracing simulations and field monitored data from a full-scale testbed. Simulations of daylight-redirecting films, a micro-louvered screen, and venetian blinds using variable resolution, tensor tree BSDF input data derived from interpolated scanning goniophotometer measurements were shown to agree with field monitored data to within 20% for greater than 75% of the measurement period for illuminance-based performance parameters. The three-phase method delivered significantly less accurate results. We discuss the ramifications of these findings on industry and provide recommendations to increase end user awareness of the current limitations of existing software tools and BSDF product libraries.

14 SOLAR ENERGY↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extreme Scale Computing to Secure the Nation

Since the dawn of modern electronic computing in the mid 1940's, U.S. national security programs have been dominant users of every new generation of high-performance computer. Indeed, the first general-purpose electronic computer, ENIAC (the Electronic Numerical Integrator and Computer), was used to calculate the expected explosive yield of early thermonuclear weapons designs. Even the U. S. numerical weather prediction program, another early application for high-performance computing, was initially funded jointly by sponsors that included the U.S. Air Force and Navy, agencies interested in accurate weather predictions to support U.S. military operations. For the decades of the cold war, national security requirements continued to drive the development of high performance computing (HPC), including advancement of the computing hardware and development of sophisticated simulation codes to support weapons and military aircraft design, numerical weather prediction as well as data-intensive applications such as cryptography and cybersecurity U.S. national security concerns continue to drive the development of high-performance computers and software in the U.S. and in fact, events following the end of the cold war have driven an increase in the growth rate of computer performance at the high-end of the market. This mainly derives from our nation's observance of a moratorium on underground nuclear testing beginning in 1992, followed by our voluntary adherence to the Comprehensive Test Ban Treaty (CTBT) beginning in 1995. The CTBT prohibits further underground nuclear tests, which in the past had been a key component of the nation's science-based program for assuring the reliability, performance and safety of U.S. nuclear weapons. In response to this change, the U.S. Department of Energy (DOE) initiated the Science-Based Stockpile Stewardship (SBSS) program in response to the Fiscal Year 1994 National Defense Authorization Act, which requires, 'in the absence of nuclear testing, a progam to: (1) Support a focused, multifaceted program to increase the understanding of the enduring stockpile; (2) Predict, detect, and evaluate potential problems of the aging of the stockpile; (3) Refurbish and re-manufacture weapons and components, as required; and (4) Maintain the science and engineering institutions needed to support the nation's nuclear deterrent, now and in the future'. This program continues to fulfill its national security mission by adding significant new capabilities for producing scientific results through large-scale computational simulation coupled with careful experimentation, including sub-critical nuclear experiments permitted under the CTBT. To develop the computational science and the computational horsepower needed to support its mission, SBSS initiated the Accelerated Strategic Computing Initiative, later renamed the Advanced Simulation & Computing (ASC) program (sidebar: 'History of ASC Computing Program Computing Capability'). The modern 3D computational simulation capability of the ASC program supports the assessment and certification of the current nuclear stockpile through calibration with past underground test (UGT) data. While an impressive accomplishment, continued evolution of national security mission requirements will demand computing resources at a significantly greater scale than we have today. In particular, continued observance and potential Senate confirmation of the Comprehensive Test Ban Treaty (CTBT) together with the U.S administration's promise for a significant reduction in the size of the stockpile and the inexorable aging and consequent refurbishment of the stockpile all demand increasing refinement of our computational simulation capabilities. Assessment of the present and future stockpile with increased confidence of the safety and reliability without reliance upon calibration with past or future test data is a long-term goal of the ASC program. This will be accomplished through significant increases in the scientific bases that underlie the computational tools. Computer codes must be developed that replace phenomenology with increased levels of scientific understanding together with an accompanying quantification of uncertainty. These advanced codes will place significantly higher demands on the computing infrastructure than do the current 3D ASC codes. This article discusses not only the need for a future computing capability at the exascale for the SBSS program, but also considers high performance computing requirements for broader national security questions. For example, the increasing concern over potential nuclear terrorist threats demands a capability to assess threats and potential disablement technologies as well as a rapid forensic capability for determining a nuclear weapons design from post-detonation evidence (nuclear counterterrorism).

99 GENERAL AND MISCELLANEOUS↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Explorer-II: Wireless Self-Powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and recovery of the system using custom fittings and a (to be developed) launch-chamber/-tube. The battery modules are used to power the system, by providing power to the robot's bus. The support modules perform the functions of centration for the rest of the train as well as odometry pickups using incremental encoding schemes. The electronics architecture is based on a distributed (8-bit) microprocessor architecture (at least 1 in ea. module) communicating to a (one of two) 32-bit SBC, which manages all video-processing, posture and motion control as well as CAN and wireless communications. The operator controls the entire system from an off-board (laptop) controller, which is in constant wireless communication with the robot train in the pipe. The sensor modules collect data and forward it to the robot operator computer (via the CAN-wireless communications chain), who then transfers it to a dedicated NDE data-storage and post-processing computer for further (real-time or off-line) analysis. The prototype robot system was built and tested indoors and outdoors, outfitted with a Remote-Field Eddy Current (RFEC) sensor integrated as its main NDE sensor modality. An angled launcher, allowing for live launching and retrieval, was also built to suit custom angled launch-fittings from TDW. The prototype vehicle and launcher systems are shown. The complete system, including the in-pipe robot train, launcher, integrated NDE-sensor and real-time video and control console and NDE-data collection and -processing and real-time display, were demonstrated to all sponsors prior to proceeding into final field-trials--the individual components and setting for said acceptance demonstration are shown. The launcher-tube was also used to verify that the vehicle system is capable of operating in high-pressure environments, and is safely deployable using proper evacuating/purging techniques for operation in the potentially explosive natural gas environment. The test-setting and environment for safety-certification of the X-II robot platform and the launch and recovery procedures, is shown. Field-trials were successfully carried out in a live steel pipeline in Northwestern Pennsylvania. The robot was launched and recovered multiple times, travelling thousands of feet and communicating in real time with video and command-and-control (C&C) data under remote operator control from a laptop, with NDE sensor-data streaming to a second computer for storage, display and post-processing. Representative images of the activities and systems used in the week-long field-trial are shown. CMU also evaluated the ability of the X-II design to be able to integrate an MFL sensor, by adding additional drive-/battery-/steering- and support-modules to extend the X-II train.

03 NATURAL GAS↗