Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heterodyne spectrophotometry of ozone in the 9.6-micron band using a tunable diode laser

Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (0.0003/cm) solar spectra in the 9.6-micron ozone band. Observations have shown that a signal-to-noise ratio of 120:1 (about 30 percent of theoretical) for an integration time of 1/8 s can be achieved at a resolution of 0.0013 wave numbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that measured at the nearby NOAA ozone monitoring facility in Boulder, Colorado. Line positions for several ozone lines in the spectral region 996-997/cm are reported. Recent improvements have produced a signal-to-noise ratio of 95:1 (about 40 percent of theoretical) at 0.0003/cm and extended the range of wavelengths which can be observed.

Mcelroy, C. T.↗

Ground testing of the Li-ion batteries in support of JPL's 2003 Mars Exploration Rover Mission

In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(deg)C to +4O(deg)C), withstand long storage periods (e.g., cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the viability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit (RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The testing performed includes, (a) performing initial characterization tests (discharge capacity at different temperatures), (b) simulating the launch conditions, (c) simulating the cruise phase conditions (including trajectory corrections), (d) simulating the entry, decent, and landing pulse load profile (if required to support the pyros) (e) simulating the Mars surface operation mission simulation conditions, as well as, (f) assessing performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by LithiodYardney, Inc.) were demonstrated to far exceed the requirements defined by the mission, and are projected to support an extended mission (> 2 years) with margin to spare.

Li-ion batteries↗

Analysis of IUE observations of hydrogen in comets

The large body of hydrogen Lyman-alpha observations of cometary comae obtained with the International Ultraviolet Explorer satellite has gone generally unanalyzed because of two main modeling complications. First, the inner comae of many bright (gas productive) comets are often optically thick to solar Lyman-alpha radiation. Second, even in the case of a small comet (low gas production) the large IUE aperture is quite small as compared with the immense size of the hydrogen coma, so an accurate model which properly accounts for the spatial distribution of the coma is required to invert the inferred brightnesses to column densities and finally to H atom production rates. Our Monte Carlo particle trajectory model (MPTM), which for the first time provides the realistic full phase space distribution of H atoms throughout the coma was used as the basis for the analysis of IUE observations of the inner coma. The MCPTM includes the effects of the vectorial ejection of the H atoms upon dissociation of their parent species (H2O and OH) and of their partial collisional thermalization. Both of these effects are crucial to characterize the velocity distribution of the H atoms. A new spherical radiative transfer calculation based on our MCPTM was developed to analyze IUE observations of optically thick H comae. The models were applied to observations of comets P/Giacobini-Zinner and P/Halley.

Combi, Michael R.↗

Characterization and Compensation of the Atmosphere for the Inversion of AVIRIS Calibrated Radiance to Apparent Surface Reflectance

Calibrated radiance spectra measured remotely record the integrated effects of the solar source, the atmosphere, and the surface. To pursue scientific research and applications, based on the molecular absorptions and constituent scattering properties of the surface, the solar source and atmosphere must be characterized and compensated in the spectra. This paper describes a set of radiative transfer spectral fitting algorithms that characterize the absorbing and scattering constituents of the atmosphere from calibrated AVIRIS spectra. These atmospheric characteristics were used in conjunction with the illumination and observation geometries to invert the AVIRIS calibrated radiance spectra to apparent surface reflectance. A validation of the algorithm was performed with in-situ reflectance spectra acquired at the time of the AVIRIS overflight over Pasadena, California, in 1994.

Green Robert O.↗

Comparative Analysis of the 2020 November 29 Solar Energetic Particle Event Observed by Parker Solar Probe

We analyze two specific features of the intense solar energetic particle (SEP) event observed by Parker Solar Probe (PSP) between 2020 November 29 and 2020 December 2. The interplanetary counterpart of the coronal mass ejection (CME) on 2020 November 29 that generated the SEP event (hereafter ICME-2) arrived at PSP (located at 0.8 au from the Sun) on 2020 December 1. ICME-225 was preceded by the passage of an interplanetary shock at 18:35 UT on 2020 November 30 (hereafter26S2), that in turn was preceded by another ICME (i.e., ICME-1) observed in situ on 2020 November 30. The two interesting features of this SEP event at PSP are: First, the presence of the intervening ICME-1 affected the evolution of the.8 MeV proton intensity time profiles resulting in the observation of inverted energy spectra throughout the passage of ICME-1. Second, the sheath region preceding ICME-2 was characterized by weak magnetic fields compared to those measured immediately after the passage of the shock S2 and during the passage of ICME-2. Comparison with prior SEP events measured at 1 au but with similar characteristics indicates that (1) low-energy particles accelerated by S2 were excluded from propagating throughout ICME-1, and (2) the low magnetic fields measured in the sheath of ICME-2 resulted from the properties of the upstream solar wind encountered by ICME-2 that was propagated into the sheath; whereas the high energetic particle energy density in the sheath did not play a dominant role in the formation of these low magnetic fields.

D Lario↗

Method of fabricating a solar cell array

A first set of pre-tabbed solar cells are assembled in a predetermined array with at least part of each tab facing upward, each tab being fixed to a bonding pad on one cell and abutting a bonding pad on an adjacent cell. The cells are held in place with a first vacuum support. The array is then inverted onto a second vacuum support which holds the tabs firmly against the cell pads they abut. The cells are exposed to radiation to melt and reflow the solder pads for bonding the tab portions not already fixed to bonding pads to these pads.

Lazzery, Angelo G.↗

A Newton-Raphson Method Approach to Adjusting Multi-Source Solar Simulators

NASA Glenn Research Center has been using an in house designed X25 based multi-source solar simulator since 2003. The simulator is set up for triple junction solar cells prior to measurements b y adjusting the three sources to produce the correct short circuit current, lsc, in each of three AM0 calibrated sub-cells. The past practice has been to adjust one source on one sub-cell at a time, iterating until all the sub-cells have the calibrated Isc. The new approach is to create a matrix of measured lsc for small source changes on each sub-cell. A matrix, A, is produced. This is normalized to unit changes in the sources so that Ax(delta)s = (delta)isc. This matrix can now be inverted and used with the known Isc differences from the AM0 calibrated values to indicate changes in the source settings, (delta)s = A ·'x.(delta)isc This approach is still an iterative one, but all sources are changed during each iteration step. It typically takes four to six steps to converge on the calibrated lsc values. Even though the source lamps may degrade over time, the initial matrix evaluation i s not performed each time, since measurement matrix needs to be only approximate. Because an iterative approach is used the method will still continue to be valid. This method may become more important as state-of-the-art solar cell junction responses overlap the sources of the simulator. Also, as the number of cell junctions and sources increase, this method should remain applicable.

Snyder, David B.↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Solar occultation sounding of pressure and temperature using narrowband radiometers

A technique for simultaneously retrieving pressure and temperature profiles using satellite-based narrowband radiometer measurements of absorption in the CO2 4.3-micron band is described. Pressure and temperature profiles for earth's upper atmosphere on a global scale can be obtained with errors less than 3% and 3 K, respectively. The p-T information can be used not only for improving the accuracy of inverted gas concentrations in the same absorption experiment but also for investigating the upper atmosphere circulation.

Park, J. H.↗

Effects of Optimisation Parameters on Data-Driven Magnetofrictional Modelling of Active Regions

Context . The solar magnetic field plays an essential role in the formation, evolution, and dynamics of large-scale eruptive structures in the corona. The estimation of the coronal magnetic field, the ultimate driver of space weather, particularly in the ‘low’ and ‘middle’ corona, is presently limited due to practical difficulties. Data-driven time-dependent magnetofrictional modelling (TMFM) of active region magnetic fields has been proven to be a useful tool to study the corona. The input to the model is the photospheric electric field that is inverted from a time series of the photospheric magnetic field. Constraining the complete electric field, that is, including the non-inductive component, is critical for capturing the eruption dynamics. We present a detailed study of the effects of optimisation of the non-inductive electric field on the TMFM of AR 12473. Aims . We aim to study the effects of varying the non-inductive electric field on the data-driven coronal simulations, for two alternative parametrisations. By varying parameters controlling the strength of the non-inductive electric field, we wish to explore the changes in flux rope formation and their early evolution and other parameters, for instance, axial flux and magnetic field magnitude. Methods . We used the high temporal and spatial resolution cadence vector magnetograms from the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO). The non-inductive electric field component in the photosphere is critical for energising and introducing twist to the coronal magnetic field, thereby allowing unstable configurations to be formed. We estimated this component using an approach based on optimising the injection of magnetic energy. Results . Our data show that flux ropes are formed in all of the simulations except for those with the lower values of these optimised parameters. However, the flux rope formation, evolution and eruption time varies depending on the values of the optimisation parameters. The flux rope is formed and has overall similar evolution and properties with a large range of non-inductive electric fields needed to determine the non-inductive electric field component that is critical for energising and introducing twist to the coronal magnetic field. Conclusions . This study shows that irrespective of non-inductive electric field values, flux ropes are formed and erupted, which indicates that data-driven TMFM can be used to estimate flux rope properties early in their evolution without needing to employ a lengthy optimisation process.

A. Kumari↗

The influence of NO and ClO variations at twilight on the interpretation of solar occultation measurements

The influence of short lived photochemically produced species on solar occultation measurements of ClO and NO was examined. Time varying altitude profiles of ClO and NO were calculated with a time dependent photochemical model to simulate the distribution of these species during a solar occultation measurement. These distributions were subsequently used to calculate simulated radiances for various tangent paths from which mixing ratios were inferred with a conventional technique that assumes spherical symmetry. These results show that neglecting the variation of ClO in the retrieval process produces less than a 10 percent error between the true and inverted profile for both sunrise and sunset above 18 km. For NO, errors are less than 10 percent for tangent altitudes above about 35 km for sunrise and sunset; at lower altitudes, the error increases, approaching 100 percent at altitudes near 25 km. the results also show that average inhomogeneity factors, which measure the concentration variation along the tangent path and which can be calculated from a photochemical model, can indicate which species require more careful data analysis.

Boughner, R.↗

A Tower-based Prototype VHF/UHF Radar for Subsurface Sensing: System Description and Data Inversion Results

Knowledge of subsurface characteristics such as permittivity variations and layering structure could provide a breakthrough in many terrestrial and planetary science disciplines. For Earth science, knowledge of subsurface and subcanopy soil moisture layers can enable the estimation of vertical flow in the soil column linking surface hydrologic processes with that in the subsurface. For planetary science, determining the existence of subsurface water and ice is regarded as one of the most critical information needs for the study of the origins of the solar system. The subsurface in general can be described as several near-parallel layers with rough interfaces. Each homogenous rough layer can be defined by its average thickness, permittivity, and rms interface roughness assuming a known surface spectral distribution. As the number and depth of layers increase, the number of measurements needed to invert for the layer unknowns also increases, and deeper penetration capability would be required. To nondestructively calculate the characteristics of the rough layers, a multifrequency polarimetric radar backscattering approach can be used. One such system is that we have developed for data prototyping of the Microwave Observatory of Subcanopy and Subsurface (MOSS) mission concept. A tower-mounted radar makes backscattering measurements at VHF, UHF, and L-band frequencies. The radar is a pulsed CW system, which uses the same wideband antenna to transmit and receive the signals at all three frequencies. To focus the beam at various incidence angles within the beamwidth of the antenna, the tower is moved vertically and measurements made at each position. The signals are coherently summed to achieve focusing and image formation in the subsurface. This requires an estimate of wave velocity profiles. To solve the inverse scattering problem for subsurface velocity profile simultaneously with radar focusing, we use an iterative technique based on a forward numerical solution of the layered rough surface problem. The layers are each defined in terms of a small number of unknown distributions as given above. An a priori estimate of the solution is first assumed, based on which the forward problem is solved for the backscattered measurements. This is compared with the measured data and using iterative techniques an update to the solution for the unknowns is calculated. The process continues until convergence is achieved. Numerical results will be shown using actual radar data acquired with the MOSS tower radar system in Arizona in Fall 2003, and compared with in-situ measurements.

Moghaddam, Mahta↗

Performance Testing of Lithium Li-ion Cells and Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(super 0)C to +40(super 0)C), withstand long storage periods (e.g., including pre-launch and cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the inability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The primary focus of this paper is to communicate the latest results regarding Mars surface operation mission simulation testing, as well as, the corresponding performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by Yardney Technical Products, Inc.) have been demonstrated to far exceed the requirements defined by the mission, being able to support the operation of the rovers for over three years, and are projected to support an even further extended mission.

low temperature electrolytes↗

Characterization and modeling of radiation effects NASA/MSFC semiconductor devices

A literature review of the near-Earth trapped radiation of the Van Allen Belts, the radiation within the solar system resulting from the solar wind, and the cosmic radiation levels of deep space showed that a reasonable simulation of space radiation, particularly the Earth orbital environment, could be simulated in the laboratory by proton bombardment. A 3 MeV proton accelerator was used to irradiate CMOS integrated circuits fabricated from three different processes. The drain current and output voltage for three inverters was recorded as the input voltage was swept from zero to ten volts after each successive irradiation. Device parameters were extracted. Possible damage mechanisms are discussed and recommendations for improved radiation hardness are suggested.

Kerns, D. V., Jr.↗

X-Ray Source Motions and Their Implications for Flare Models

RHESSI observations have revealed a downward contraction of solar flare loops followed by upward expansion. In some flares a pair of above-the-looptop sources is observed, one just above the top of the cooler flare loops and the other a discrete source well above the looptops characterized by an effective temperature gradient increasing toward lower altitudes. In one flare the higher, temperature-inverted coronal source sped outward at a speed consistent with that of a coronal mass ejection associated with the flare. In some flares with minimal preheating (early impulsive flares), nonthermal X-ray sources have been observed to propagate downward and then upward along the legs of the flare loop. I will discuss the implications of all of these X-ray source motions for flare models, and their use as diagnostics of the evolution of the physical conditions in flares.

Holman, Gordon D.↗

NASA Tech Briefs, April 2002

The contents include: 1) Application Briefs; 2) Sneak Preview of Sensors Expo; 3) The Complexity of the Diagnosis Problem; 4) Design Concepts for the ISS TransHab Module; 5) Characteristics of Supercritical Transitional Mixing Layers; 6) Electrometer for Triboelectric Evaluation of Materials; 7) Infrared CO2 Sensor With Built-In Calibration Chambers; 8) Solid-State Potentiometric CO Sensor; 9) Planetary Rover Absolute Heading Detection Using a Sun Sensor; 10) Concept for Utilizing Full Areas of STJ Photodetector Arrays; 11) Development of Cognitive Sensors; 12) Enabling Higher-Voltage Operation of SOl CMOS Transistors; 13) Estimating Antenna-Pointing Errors From Beam Squints; 14) Advanced-Fatigue-Crack-Growth and Fracture- Mechanics Program; 15) Software for Sequencing Spacecraft Actions; 16) Program Distributes and Tracks Organizational Memoranda; 16) Flat Membrane Device for Dehumidification of Air; 17) Inverted Hindle Mount Reduces Sag of a Large, Precise Mirror; 18) Heart-Pump-Outlet/Cannula Coupling; 19) Externally Triggered Microcapsules Release Drugs In Situ; 20) Combinatorial Drug Design Augmented by Information Theory; 21) Multiple-Path-Length Optical Absorbance Cell; 22) Model of a Fluidized Bed Containing a Mixture of Particles; 23) Refractive Secondary Concentrators for Solar Thermal Systems; 24) Cold Flow Calorimeter; 25) Methodology for Tracking Hazards and Predicting Failures; 26) Estimating Heterodyne-Interferometer Polarization Leakage; 27) An Efficient Algorithm for Propagation of Temporal- Constraint Networks; 28) Software for Continuous Replanning During Execution; 29) Surface-Launched Explorers for Reconnaissance/Scouting; 30) Firmware for a Small Motion-Control Processor; 31) Gear Bearings and Gear-Bearing Transmissions; and 32) Linear Dynamometer With Variable Stroke and Frequency.

Source record↗

Comparison of SOHO/UVCS and MLSO MK4 Coronameter Densities

This paper compares the density distributions of the solar corona obtained by UVCS and the Mauna MLSO MK4 coronameter. This is the first attempt to compare the coronal densities estimated by the two instruments. Two UVCS emission lines (O VI 1032 hand 1037.6 A), which have both radiative and collisional components, were used. The coronal number density is determined from the ratio of these two components. The coronal density can be determined by inverting MLSO MK4 polarization maps. It was found that the mean electron number density in a helmet streamer observed by MK4 on 2003 April 28 is fairly consistent with that observed by UVCS. For a coronal hole and an active region observed on 1999 October 19 and 24, the MK4 coronal densities are close to those from the UVCS. The results demonstrate that MK4 polarization data can provide a coronal density distribution in a large field of view with a time cadence of about three minutes.

Lee, K.-S.↗

Pressure sensing of the atmosphere by solar occultation using broadband CO2 absorption

A technique for obtaining pressure at the tangent point in an IR solar occulation experiment is described. By measuring IR absorption in bands of atmospheric CO2 (e.g., 2.0, 2.7, or 4.3 microns), mean pressure values for each tangent point layer (vertical thickness 2 km or less) of the atmosphere can be obtained with rms errors of less than 3%. The simultaneous retrieval of pressure and gas concentration in a remote-sensing experiment will increase the accuracy of inverted gas concentrations and minimize the dependence of the experiment on pressure or mass path error resulting from use of climatological pressure data, satellite ephemeris, and instrument pointing accuracy.

Park, J. H.↗