Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

125 records · Page 7

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Systems

Although most of the current photovoltaic (PV) system installations use monofacial modules with fixed-tilt mounting structures, bifacial modules, trackers, and the combination of them are also getting more attention as potential candidates to further reduce the PV levelized cost of electricity (LCOE). This work is then the first to present a worldwide analysis on the yield potential and cost-effectiveness of PV farms composed of monofacial fixed-tilt and single/dual (1T/2T) tracker installations, as well as their bifacial counterparts. Our approach starts by estimating the irradiance reaching the front and rear surface of the modules for the different system designs (validated based on data from real PV systems and results from the literature) to estimate their energy production (row-row shading is neglected). Subsequently, the overall system cost during their 25-year lifetime is factored in, and LCOE is obtained. The results reveal that bifacial-1T installations increase energy yield by 35% and reach the lowest LCOE for the majority of the world (93.1% of the land area). Although dual axis trackers achieve the highest energy generation — especially for bifacial modules — their cost is still too high, and are therefore not as cost-effective. Sensitivity analyses based on the Monte Carlo and region sensitivity approach are performed to analyze the impact of input assumptions on the calculated LCOE. These reveal that our conclusions are robust in general but exact configuration to choose depends on specific site conditions. This investigation is not only of interest to the scientific community, but also can be used as a guide for PV installation companies and investors to determine the most suitable technology for a particular location.

14 SOLAR ENERGY↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

Field Experience with 3-Sun Mirror Module Systems

JX Crystals 3-sun PV mirror modules have now been operating in four separate systems in the field for up to 2 years. Two post-mounted 2-axis tracking arrays of 12 modules each were installed at the Shanghai Flower Park in April of 2006. Then 672 modules were installed in a 100 kW array on N-S horizontal beam trackers at the Shanghai Flower Port in November of 2006. Finally, sets of 4 modules were installed on azimuth-tracking carousels on buildings at the Oak Ridge National Lab and at the U. of Nevada in Las Vegas in late 2007. All of these modules in each of these systems are still operating at their initial power ratings. No degradation in performance has been observed. The benefit of these 3-sun PV mirror modules is that they use 1/3 of the silicon single-crystal cell material in comparison to traditional planar modules. Since aluminum mirrors are much cheaper than high-purity single-crystal silicon-cells, these modules and systems should be much lower in cost when manufactured in high volume.

14 SOLAR ENERGY↗

Estimation of the potential array output charge in the performance analysis of stand-alone photovoltaic systems without MPPT (Case study: Mediterranean climate)

The potential array output energy, E{sub P}, stated by the Joint Research Centre (JRC) in their European Guidelines for the Assessment of Photovoltaic Plants and the IEC Standard 61724 does not estimate properly the potential array output of stand-alone photovoltaic (SAPV) systems without maximum power point tracker (MPPT) as it is the case for SAPV systems with MPPT and grid connected systems. In this way, the main purpose of this paper is to validate an expression that compromises simplicity and accuracy when estimating the potential array output of SAPV systems without MPPT. This issue can be of high interest to photovoltaic (PV) practitioners and experts as it can improve the analysis performance of this type of systems, helping to discriminate better the different losses in this kind of systems. Furthermore, a study of the array potential estimation through different expressions will be developed in order to evaluate which matches better the array potential output in SAPV system without MPPT. Although the analysis will be focused especially in Mediterranean climates, it will be derived some general conclusions that can be considered in other climates. (author)

14 SOLAR ENERGY↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

PSCAD Modules Representing PV Generator

Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

14 SOLAR ENERGY↗

THEORY OF DISPERSED FIXED-DELAY INTERFEROMETRY FOR RADIAL VELOCITY EXOPLANET SEARCHES

The dispersed fixed-delay interferometer (DFDI) represents a new instrument concept for high-precision radial velocity (RV) surveys for extrasolar planets. A combination of a Michelson interferometer and a medium-resolution spectrograph, it has the potential for performing multi-object surveys, where most previous RV techniques have been limited to observing only one target at a time. Because of the large sample of extrasolar planets needed to better understand planetary formation, evolution, and prevalence, this new technique represents a logical next step in instrumentation for RV extrasolar planet searches, and has been proven with the single-object Exoplanet Tracker (ET) at Kitt Peak National Observatory, and the multi-object W. M. Keck/MARVELS Exoplanet Tracker at Apache Point Observatory. The development of the ET instruments has necessitated fleshing out a detailed understanding of the physical principles of the DFDI technique. Here we summarize the fundamental theoretical material needed to understand the technique and provide an overview of the physics underlying the instrument's working. We also derive some useful analytical formulae that can be used to estimate the level of various sources of error generic to the technique, such as photon shot noise when using a fiducial reference spectrum, contamination by secondary spectra (e.g., crowded sources, spectroscopic binaries, or moonlight contamination), residual interferometer comb, and reference cross-talk error. Following this, we show that the use of a traditional gas absorption fiducial reference with a DFDI can incur significant systematic errors that must be taken into account at the precision levels required to detect extrasolar planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on 1-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored. shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗

Generating Synthetic Time Series Photovoltaic Data with Real-World Physical Challenges and Noise for Use in Algorithm Test and Validation

The PV Fleet Data Initiative and other projects seek the develop algorithms for automated analysis of PV time series data for extraction of statistical information and other parameters of the data such as degradation rates, soiling loss information, tracker performance, clipping or curtailment, system availability and other valuable information. While there is a vast body of PV data available for application of said extraction algorithms it is difficult to validate these algorithms because the true parameters to be extracted are not known. There has been a wide use of synthetic data in the literature for algorithm validation but this synthetic data is typically very bounded by the problem or topic at hand. The PV Fleet Data Initiative project has demonstrated that real time series PV data almost always includes a host of data quality and physical problems that, in reality, any automated PV abstraction algorithm must handle appropriately. For this reason, this work describes the development of a complex synthetic PV times series data set that includes data quality and physical problems that have been experienced in real world PV data. The various quality and physical problems are documented in the synthetic data so that users can test the validity of various PV extraction algorithms as well as develop new algorithms to solve problems this data set can support.

14 SOLAR ENERGY↗

Evaluation of Composite Structural Materials for Heliostat Cost Reduction

Structures manufactured from steel comprise up to 40% of a CSP heliostat's cost. Composite structures represent a potential opportunity to reduce this cost. A reference heliostat structural model has been created with a reflector area of 25m 2 . The design, constructed of low-carbon steel, pro-vides baseline deflection and stiffness under a 21 m/s operating wind speeds. Wind loads on the tracker structure are determined for both operating and stow conditions. An established roster of suitable metal alternative materials is considered including: glass, basalt, and carbon reinforced polymer (GFRP, BFRP, and CFRP respectively). Three heliostat components are investigated: the pylon, torque tube, and the purlin-strut assembly. Composite material properties are substituted for those of steel, and the beams are re-sized to match the original steel components' deflection under given wind loads. Weight and cost changes resulting from this resizing are evaluated. It is found that GFRP and BFRP represent a 3X–6X cost premium for the same operating deflection character-istics as steel across all three investigated component classes; with weight reduction only achieved for the purlin-strut assembly. While CFRP components can achieve approximately 25–75% weight savings depending on the application, this comes with a 9X–14X cost increase over the steel base-line for tube-type structures and roughly 5X cost increase when replacing c-channel structures. This work does not rule out the possibility of cost savings when the heliostat design and kinematics to take advantage of composites' specific properties.

14 SOLAR ENERGY↗

Life after 30 years - a PV system in Colorado

The PV system consisted of 155 monocrystalline Si Arco M53 panels, installed in 1987. 80 were installed on a fixed tilt rack, and 75 on 5 separate dual-axis passive trackers. The system was decommissioned in 2017 due a campus re-design and building expansion at the Platte River Power Authority (PPRA) site. Prior to decommissioning a site visit established the following failure type observations: EVA browning (100%), cracked cells (60%), and cracked wires or grommets (9%, or more if replacements were made selectively on cracked parts). EVA browning is typical in modules of this vintage, whereas the occurrence of so many cracked cells is surprising and is likely weather-related. The fairly frequent occurrence of cracked wires and grommets serves as a reminder that accelerated testing of these components is important for goals of low-cost 50-year energy generation. In smaller numbers, thermal effects (7%), bent frames (1%), and cell corrosion (<1%) were observed. A sample of 20 modules was selected and brought to NREL for in-depth characterization. Because baseline measurements were not available using the nameplate rating, which can be inaccurate, revealed a mean module sample degradation of 0.7 %/year. Sporadic production data during the 30 years determined a system degradation rate closer to 1.2 %/year. Subsequently, four of these modules were re-mounted outdoors at NREL and are now approaching a total lifetime of 34 years.

durability↗

A faster and more reliable data acquisition system for the full performance of the SciCRT

The SciBar Cosmic Ray Telescope (SciCRT) is a massive scintillator tracker to observe cosmic rays at a very high-altitude environment in Mexico. The fully active tracker is based on the Scintillator Bar (SciBar) detector developed as a near detector for the KEK-to-Kamioka long-baseline neutrino oscillation experiment (K2K) in Japan. Since the data acquisition (DAQ) system was developed for the accelerator experiment, we determined to develop a new robust DAQ system to optimize it to our cosmic-ray experiment needs at the top of Mt. Sierra Negra (4600 m). One of our special requirements is to achieve a 10 times faster readout rate. We started to develop a new fast readout back-end board (BEB) based on 100 Mbps SiTCP, a hardware network processor developed for DAQ systems for high energy physics experiments. Then we developed the new BEB which has a potential of 20 times faster than the current one in the case of observing neutrons. Lastly, we installed the new DAQ system including the new BEBs to a part of the SciCRT in July 2015. The system has been operating since then. In this article, we describe the development, the basic performance of the new BEB, the status after the installation in the SciCRT, and the future performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗