Fabrication of experimental three-meter space telescope primary and secondary mirror support structure

The fabrication of prototype titanium alloy primary and secondary mirror support structures for a proposed experimental three-meter space telescope is discussed. The structure was fabricated entirely of Ti-6Al-4V tubing and plate. Fabrication included the development of procedures including welding, forming, and machining. Most of the structures was fabricated by gas-shielding tungsten-arc (GTA) welding with several major components fabricated by high frequency resistance (HFR) welding.

Mishler, H. W.↗

Progress Report on the University of Arizona NGST Mirror System Demonstrator

We will present an update for the University of Arizona NGST (Next Generation Space Telescope) Mirror System Demonstrator (NMSD). The 2-m, f/5 NMSD mirror uses a 2 mm thick glass substrate and an actuated lightweight structure for surface accuracy and support. We will review the mirror's basic design and summarize the fabrication process. We will also discuss the current results from system integration and testing.

Baiocchi, Dave↗

Status of NASA Mirror Technology Development for Large Space Telescopes

This talk will present the current status of several NASA technology development activities, including: SBMD, NMSD, AMSD (Advanced Mirror System Demonstrator), etc.. And will discuss how these activities map into future NASA mission requirements, including: NGST (Next Generation Space Telescope), SAFIR, SUVO, etc.

Stahl, H. Philip↗

Lifetime Predictions of a Titanium Silicate Glass with Machined Flaws

A dynamic fatigue study was performed on a Titanium Silicate glass to assess its susceptibility to delayed failure and to compare the results with those of a previous study. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions. The material strength and lifetime was seen to increase due to the removal of residual stress through grinding and polishing. Influence on time-to-failure is addressed for the case with and without residual stress present. Titanium silicate glass otherwise known as ultra-low expansion (ULE)* glass is a candidate for use in applications requiring low thermal expansion characteristics such as telescope mirrors. The Hubble Space Telescope s primary mirror was manufactured from ULE glass. ULE contains 7.5% titanium dioxide which in combination with silica results in a homogenous glass with a linear expansion coefficient near zero. delayed failure . This previous study was based on a 230/270 grit surface. The grinding and polishing process reduces the surface flaw size and subsurface damage, and relieves residual stress by removing the material with successively smaller grinding media. This results in an increase in strength of the optic during the grinding and polishing sequence. Thus, a second study was undertaken using samples with a surface finish typically achieved for mirror elements, to observe the effects of surface finishing on the time-to-failure predictions. An allowable stress can be calculated for this material based upon modulus of rupture data; however, this does not take into account the problem of delayed failure, most likely due to stress corrosion, which can significantly shorten lifetime. Fortunately, a theory based on fracture mechanics has been developed enabling lifetime predictions to be made for brittle materials susceptible to delayed failure. Knowledge of the factors governing the rate of subcritical flaw growth in a given environment enables the development of relations between lifetime, applied stress and failure probability for the material under study. Dynamic fatigue is one method of obtaining the necessary information to develop these relationships. In this study, the dynamic fatigue method was used to construct a time-to-failure diagram for polished ULE glass.

Tucker, Dennis S.↗

An 8 Meter Monolithic UV/Optical Space Telescope

The planned Ares V launch vehicle with its 10 meter fairing and at least 55,600 kg capacity to Earth Sun L2 enables entirely new classes of space telescopes. A consortium from NASA, Space Telescope Science Institute, and aerospace industry are studying an 8-meter monolithic primary mirror UV/optical/NIR space telescope to enable new astrophysical research that is not feasible with existing or near-term missions, either space or ground. This paper briefly reviews the science case for such a mission and presents the results of an on-going technical feasibility study, including: optical design; structural design/analysis including primary mirror support structure, sun shade and secondary mirror support structure; thermal analysis; launch vehicle performance and trajectory; spacecraft including structure, propulsion, GN&C, avionics, power systems and reaction wheels; operations & servicing; mass budget and cost.

Stahl, H. Philip↗

The Case for Aggressive Segmentation of the Primary Mirror of the Next Generation Space Telescope and Future ORIGINS Missions

Optical performance variations are considered from several factors including the gap between regular hexagonal mirror segments, the relative ability of segments of different size to be manufactured with low wavefront error, and expected mirror deformations. Additionally a weight variation function will be driven by recently postulated relationships which can be expressed so as to determine thickness of the mirror segment to satisfy: (1) polishing pressures (2) 1-g sage deflection, and (3) thermal induced stress as well as ancillary masses including actuators, wiring, and electronics. The result will be to survey the trade space of segment number and size for a range of apertures from 4 to 20 meters.

Montgomery, Edward E., IV↗

B-Roll of AMSD Mirror

This video shows the Advanced Mirror System Demonstrator (AMSD) mirror being inspected and handled at Tinsley. The mirror is a beryllium mirror technology demonstrator that is a critical item demonstrating that the James Webb Space Telescope mirrors can be fabricated and will meet the performance requirements. Because Tinsley is very concerned about sharing proprietary information, the video, shot by them, does not show any key aspects of the polishing process (such as the polishing heads). The video includes workers at Tinsley rotating and inspecting the mirror. Excerpts of this video will be provided as part of a press release on JWST technology.

Source record↗

The initial lunar supply base

The first lunar supply base should have a mass less than 1000 tons, be deployed by 24 persons in 4 months, and be maintained by 10 persons. Output could be expanded 20 times in 5 years to 600,000 tons/yr by a factor of 10 expansion of the area of the solar array on the lunar surface, using low power soil beneficiation, increasing the fleet of mining vehicles, and illuminating the base continuously at night with lunar orbiting mirrors. The space manufacturing facility (SMF) will supply most of the mass (solar cells and orbiting mirrors) necessary for expansion. Several devices and procedures are suggested for development which could further reduce the total mass necessary to transport to the Moon to establish the initial lunar supply base.

Criswell, D.↗

Hybrid Electrostatic/Flextensional Mirror for Lightweight, Large-Aperture, and Cryogenic Space Telescopes

A lightweight, cryogenically capable, scalable, deformable mirror has been developed for space telescopes. This innovation makes use of polymer-based membrane mirror technology to enable large-aperture mirrors that can be easily launched and deployed. The key component of this innovation is a lightweight, large-stroke, cryogenic actuator array that combines the high degree of mirror figure control needed with a large actuator influence function. The latter aspect of the innovation allows membrane mirror figure correction with a relatively low actuator density, preserving the lightweight attributes of the system. The principal components of this technology are lightweight, low-profile, high-stroke, cryogenic-capable piezoelectric actuators based on PMN-PT (piezoelectric lead magnesium niobate-lead titanate) single-crystal configured in a flextensional actuator format; high-quality, low-thermal-expansion polymer membrane mirror materials developed by NeXolve; and electrostatic coupling between the membrane mirror and the piezoelectric actuator assembly to minimize problems such as actuator print-through.

Patrick, Brian↗

Overview and Recent Accomplishments of Advanced Mirror Technology Development (AMTD) for Very Large Space Telescopes

AMTD uses a science-driven systems engineering approach to define & execute a long-term strategy to mature technologies necessary to enable future large aperture space telescopes. Because we cannot predict the future, we are pursuing multiple technology paths including monolithic & segmented mirrors. Assembled outstanding team from academia, industry & government; experts in science & space telescope engineering. Derived engineering specifications from science measurement needs & implementation constraints. Maturing 6 critical technologies required to enable 4 to 8 meter UVOIR space telescope mirror assemblies for both general astrophysics & ultra-high contrast exoplanet imaging. AMTD achieving all its goals & accomplishing all its milestones.

Stahl, H. Philip↗

Segmented mirror figure control for a space-based far-IR astronomical telescope

For segmented large mirrors to be used effectively for astronomy they must be actively aligned and controlled to extreme levels of precision. We consider the figure control problem for a spaceborne far-IR telescope, the Precision Segmented Reflector Project Focus Moderate Mission Telescope. We propose a two-stage approach. A figure initialization controller is used to achieve initial phasing and alignment of the telescope using an imaging science detector. A figure maintenance controller keeps the telescope aligned during normal operation using a laser metrology optical truss sensor system. We show that performance of any figure control system is subject to limits on the controllability of the wavefront. Maintenance controllers are additionally limited by considerations of the observability of the wavefront from the maintenance sensors. We show preliminary results for the figure initialization controller. We present a 'Wavefront Compensation' method for figure maintenance control that minimizes wavefront errors due to misalignment errors.

Redding, David↗

Phase space variations of near equatorially mirroring ring current ions

Observations of near equatorially mirroring ring current ions before and after a magnetic storm are presented in the form of phase space densities with respect to the first adiabatic invariant. Particle densities were obtained from the medium energy particles instrument covering the energy range 24-2081 keV on ISEE 1 at L values between 3 and 8 earth radii and ratios of the magnetic field at the satellite position to the magnetic field at the magnetic equator less than 1.2. Analysis of the phase space densities through the magnetosphere reveals a well-defined high magnetic moment peak in the prestorm near-equatorial ring current ion phase space density distribution, with the magnetic storm resulting from an enhancement of phase space densities at magnetic moment values below the peak and phase space densities remaining constant above the peak. Results are found to be in good agreement with those obtained by Explorer 45 six years previously, indicating that the observed phase space density variations are characteristic of energetic ion behavior during magnetic storms.

Williams, D. J.↗

Design and tolerance analysis of two null corrector designs for the Space Telescope fine guidance aspheric collimating mirror

The collimating mirror within the Fine Guidance Subsystem of the Space Telescope's Pointing Control System is aspherized in order to correct the pupil aberration. A null corrector is needed to test the collimating mirror in autocollimation. Triplet and doublet null corrector designs are subjected to tolerance sensitivity analyses, and the doublet design is chosen despite its more restricted tolerances because of its compactness and simplicity.

Friedman, I.↗