Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Radiation Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the design margin concept with one of failure probability.

radiation hardness assurance↗

Radiation model predictions and validation using LDEF data

Radiation dosimetry aboard LDEF, as well as post-flight measurements of the radioactivity induced in numerous LDEF spacecraft components, provide unique data for evaluating the accuracy of current models for predicting both the space radiation environments (trapped proton intensity, spectra, and directionality; cosmic ray fluence) and the radiation environments induced in spacecraft components (fluence, energy spectra, secondary particle, linear energy transfer, etc.). By determining the accuracy of such models using LDEF data, and with model updates where required, improved radiation environment predictions can be made for future missions, which in turn allows improved predictions for specific radiation effects for future spacecraft components (single event upsets of microelectronics, radiation damage to focal plane arrays, noise in sensitive instrumentation, etc.). Herein, the status and results from radiation model predictions and comparisons with LDEF data is given. The calculations are made using radiation transport codes coupled with a 3-D geometry/mass model of LDEF, together with current models of the space radiation environment.

Armstrong, T. W.↗

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors↗

Wide Band Gap Radiation Detectors for Deep Space Science

Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.

ion detectors↗

Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The initial focus of the present experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on, the results of the passive dosimetry within the anthropomorphic phantoms represent the best tool to generate reliable data to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study.

Berger, Thomas↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

The NASA Space Solar Cell Advanced Research Program

Two major requirements for space solar cells are high efficiency and survivability in the naturally occurring charged particle space radiation environment. Performance limits for silicon space cells are well understood. Advanced cells using GaAs and InP are under development to provide significantly improved capability for the future.

Flood, Dennis J.↗

Simulation of Earth-Moon-Mars Environments for the Assessment of Organ Doses

Space radiation environments for historically large solar particle events (SPE) and galactic cosmic rays (GCR) at solar minimum and solar maximum are simulated in order to characterize exposures to radio-sensitive organs for missions to low-Earth orbit (LEO), moon, and Mars. Primary and secondary particles for SPE and GCR are transported through the respective atmosphere of Earth or Mars, space vehicle, and astronaut s body tissues using the HZETRN/QMSFRG computer code. In LEO, exposures are reduced compared to deep space because particles are deflected by the Earth s magnetic field and absorbed by the solid body of the Earth. Geomagnetic transmission function as a function of altitude was applied for the particle flux of charged particles, and the shift or the organ exposures to higher velocity or lower stopping powers compared to those in deep space were analyzed. In the transport through Mars atmosphere, a vertical distribution of atmospheric thickness was calculated from the temperature and pressure data of Mars Global Surveyor, and the directional cosine distribution was implemented to describe the spherically distributed atmospheric distance along the slant path at each altitude. The resultant directional shielding by Mars atmosphere at solar minimum and solar maximum was used for the particle flux simulation at various altitudes on the Martian surface. Finally, atmospheric shielding was coupled with vehicle and body shielding for organ dose estimates. We made predictions of radiation dose equivalents and evaluated acute symptoms at LEO, moon, and Mars at solar minimum and solar maximum.

Kim, Myung-Hee↗

The Galactic Cosmic Ray Simulator at the NASA Space Radiation Research Laboratory

With NASA’s new Artemis plan for a sustainable return to the moon, astronauts will once again leave Earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR). The ever penetrating GCR will continue to pose significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, and degenerative tissue effects including circulatory and heart disease. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the “GCR simulator” to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle.

NASA Space Radiation Laboratory↗

Radiation in Microgravity

Spaceflight results in unavoidable exposure of astronauts or experimental organisms to the complex space radiation environment while simultaneously subjecting the individuals to gravity unloading and other stresses such as vibroacoustic stimuli.

Space radiation environment↗

Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

Kim, Myung-Hee Y.↗

A summary of the OV1-19 satellite dose, depth dose, and linear energy transfer spectral measurements

Measurements of the biophysical and physical parameters in the near earth space environment, specifically, the Inner Van Allen Belt are discussed. This region of space is of great interest to planners of the Skylab and the Space Station programs because of the high energy proton environment, especially during periods of increased solar activity. Many physical measurements of charged particle flux, spectra, and pitch angle distribution have been conducted and are programmed in the space radiation environment. Such predictions are not sufficient to accurately predict the effects of space radiations on critical biological and electronic systems operating in these environments. Some of the difficulties encountered in transferring from physical data to a prediction of the effects of space radiation on operational systems are discussed.

Cervini, J. T.↗

Compendium of Current Single Event Effects for Candidate Spacecraft Electronics for NASA

NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment are often limited by their susceptibility to single event effects (SEE). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is and adequate understanding of the test condition is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), and single-event transient (SET). For total ionizing dose (TID) and displacement damage dose (DDD) results, see a companion paper submitted to the 2015 Institute of Electrical and Electronics Engineers (IEEE) Nuclear and Space Radiation Effects Conference (NSREC) Radiation Effects Data Workshop (REDW) entitled "compendium of Current Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA by M. Campola, et al.

spacecraft electronics↗