Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years.

36 MATERIALS SCIENCE↗

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years. In this project we developed a machine learning-based algorithm capable of automatically generating device designs to produce desired optical properties, reducing the design cycle life in certain situations to be almost instantaneous.

36 MATERIALS SCIENCE↗

Geothermal Play Fairway Analysis of Low-Temperature Resources for Sedimentary Basin Geothermal Play Types: An Example in the Denver Basin

This project is part of a nationwide effort to highlight the advantages of incorporating low-temperature geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). The initiative aims to hasten the nation's decarbonization process by exploring the potential for using low-temperature geothermal resources (< 150 Degrees Celsius) in selected sedimentary basins that have several population centers. The Play Fairway Analysis (PFA) techniques were modified from earlier studies of sedimentary basin geothermal play types (SBGPTs) that assessed the viability of low-temperature resources. The decision-making process for leveraging low-temperature geothermal resources for GDU and CHP applications is complex and considers a variety of factors, including geological, economic, and risk criteria. This study covers workflows, relevant datasets, python code, and both common and composite maps used to create low-temperature geothermal resource favorability maps for the Denver Basin, which extends across Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. The proposed geothermal PFA approach for low-temperature geothermal resources includes: (1) identifying available relevant data and grouping data sets into PFA criteria (e.g., geological, economic, and risk criteria); (2) analyzing data gaps enable future focalized exploration; (3) performing uncertainty quantification; (4) weighting relevant data; (5) developing favorability and common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection. This project will facilitate future deployment of CHP and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources in sedimentary basins.

15 GEOTHERMAL ENERGY↗

Industrial Electrification Technologies Booklet

Electrification refers to transitioning from fuel-powered systems to electrically-powered alternatives. In an industrial context, this primarily refers to the electrification of process heat, but there are also widespread opportunities to electrify space heating and cooling as well as onsite transportation (e.g., forklifts). Electrification does not refer to one particular technology, but a wide range of technologies that use different methods to transfer electrical energy into a usable form – usually heat.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Development of New g-function Data for Simulating a Novel Shallow Bore Ground Heat Exchanger

Geothermal heat pump (GHP), which is also referred as ground source heat pump, is the most energy-efficient technology for space heating and cooling. However, the application of GHP is hindered by its high initial cost, of which approximately 30% is for the ground heat exchanger (GHE). In recent years, researchers have developed different types of shallow bore ground heat exchangers (SBGHE) intending to reduce the cost of drilling. The ability to predict the thermal response of an SBGHE is critical for sizing SBGHE. While g-functions have been commonly used for predicting the thermal response of conventional vertical bore ground heat exchangers (VBGHE), they cannot be directly used for predicting the performance of SBGHE because they did not account for the impacts of the seasonal variation of the soil temperature along with the depth of an SBGHE. In addition, an SBGHE has a larger thermal mass within the borehole than the VBGHE due to the larger borehole diameter of SBGHE. This study develops new g-function data pairs for a new design of SBGHE, which is named Underground Thermal Battery (UTB). Impacts of the seasonal variation of soil temperature on the thermal response of UTB were accounted for by superposing a time-dependent soil temperature onto the g-functions calculated with a numerical model that assumes constant undisturbed soil temperature. The TOUGH program was used to predict the thermal response of several configurations involving multiple UTBs. The results indicate that the proposed methodology is appropriate to generate g-functions for the UTB, and the g-function value of UTB is much lower than that of VBGHE in the time range of 15 min to 1 year due to the large thermal mass and convection heat transfer within the UTB.

Shi, Liang↗

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Thermal Energy Storage in Commercial Buildings

Space heating and cooling account for as much as 40% of energy used in commercial buildings. Aligning this energy consumption with renewable energy generation through practical and viable energy storage solutions will be pivotal in achieving 100% clean energy by 2050. Integrated on-site renewable energy sources and thermal energy storage systems can provide a significant reduction of carbon emissions and operational costs for the building owner.

buildings energy storage↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Incoherent Dynamics of Intense Proton Beams under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5~MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incoherent Dynamics of Intense Proton Beams Under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

43 PARTICLE ACCELERATORS↗