Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spallation Neutron Source (SNS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Building Initial Dynamic System Models for Digital Twins of the Cryogenic Moderator System at the ORNL Spallation Neutron Source

This work describes the initial development of dynamic system models of the cryogenic moderator system (CMS) of the Spallation Neutron Source (SNS) at ORNL as a part of the ORNL LDRD funded project Building TRANSFORM to Accelerate Digital Twin Applications for Nuclear Systems, LOIS 10563. The goal of the work is to start the dynamic system modeling effort with the end goal of using them for real-time applications as digital twins. The CMS is a cryogenic liquid hydrogen flow loop that provides moderation of the neutrons that are generated by the SNS. For optimal neutron production, the CMS needs to maintain a steady and controlled density of cryogenic hydrogen in the moderator section thus requiring precise temperature and pressure control. Due to the varied time scales and system characteristics, control of the system is complex, and diagnostics are also difficult. Difficulty in accessing the flow loop during operations, limited instrumentation and unknown design details of the equipment combine to make the case for having sophisticated digital twin models of the system. Operationally the CMS also provides a strong use case for digital twins due to the constant need of optimization and for troubleshooting/diagnostics. The large amount of data collected which are freely available for using in building the model and verifying and validating the model also makes it a great candidate for a proof-of-concept for digital twins. The project extends ORNL's capacity of development and implementation of the open-source dynamic system modeling tool TRANSFORM for engineering design and digital twin/real-time applications. Specific system configuration data for the CMS have been gathered and an initial dynamic model was created in the TRANSFORM library using Dymola as the solution platform. Models of increasing complexity are created to demonstrate the need for a multi-layered approach in digital twin modeling depending on the scale and phenomena being focused on. The dynamic modeling is shown to bring the dynamic operational aspects to the design process for systems as well as serve as a digital twin to the hardware and allow for models to be tuned and compared against real time operational data. These aims should help to push forward strategic goals of application of digital twins and increase the impact of ORNL systems modeling capabilities with TRANSFORM/Modelica for various advanced energy systems.

42 ENGINEERING↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty Aware Deep Learning for Particle Accelerators

Standard deep learning models for classification and regression applications are ideal for capturing complex system dynamics. However, their predictions can be arbitrarily inaccurate when the input samples are not similar to the training data. Implementation of distance aware uncertainty estimation can be used to detect these scenarios and provide a level of confidence associated with their predictions. In this paper, we present results from using Deep Gaussian Process Approximation (DGPA) methods for errant beam prediction at Spallation Neutron Source (SNS) accelerator (classification) and we provide an uncertainty aware surrogate model for the Fermi National Accelerator Lab (FNAL) Booster Accelerator Complex (regression).

Rajput, Kishansingh↗

Second Target Station Project: STS/PSD/ESTD Workshop on Batteries and Energy Storage

Oak Ridge National Laboratory's (ORNL) upcoming Second Target Station (STS) at the Spallation Neutron Source (SNS) provides a substantial leap forward in neutron scattering capabilities, offering high-brightness cold neutron sources that have the potential to revolutionize the study of energy materials. This report highlights the outcomes of a cross-directorate workshop on Batteries and Energy Storage held in September 2023, which brought together stakeholders from the STS Project, the Physical Sciences Directorate (PSD), the Energy Science and Technology Directorate (ESTD), and the Neutron Sciences Directorate (NScD).

25 ENERGY STORAGE↗

Analysis of Second Target Station Target Segment Removal Dose Rates

This report documents the analysis of the dose rate fields in two configurations of the target system of the Second Target Station (STS) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) in support of the remote handling target segment removal operation. The two configurations detailed in this report are both assuming 8 hours since beam was incident on the target. The first configuration assumes all shielding is in place just as it was during operation and allows for confirmation of hands-on maintenance capability of the target drive components. The second configuration assumes that a hatch in the target drive room ceiling has been opened to the high bay, the target segment removable core vessel shield block has been removed, and there is a direct line-of-sight to the target segment some 5 m below the target drive room elevation. Dose rate fields in both configurations are documented in this report along with details of the methods of computation. The dose rate fields included in this report are intended to support the engineering of remote handling special equipment and the planning of remote handing operations. The models and analysis detailed in this report are in support of the preliminary design of the STS and future analysis is needed to support the final design of the STS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Oak Ridge National Laboratory's Strategic Research and Development Insights for Digital Twins

Oak Ridge National Laboratory (ORNL) is pleased to provide our response to the NITRD RFI on Digital Twins Research and Development. Digital twins are virtual representations of physical systems, leveraging real-time data to simulate and predict behaviors. ORNL is advancing digital twin technology across various disciplines, including neutron scattering, networking, science ecosystems, supercomputing, secure facilities, mobility technologies, materials design and discovery, power systems, fusion reactors, biological sciences, and earth observation. These efforts aim to enhance scientific research, operational efficiency, and decision-making processes. ORNL facilities, such as the High Flux Isotope Reactor (HFIR), Grid-C, Spallation Neutron Source (SNS), and Oak Ridge Leadership Computing Facility (OLCF), provide the infrastructure to develop and demonstrate these digital twin technologies. In this document, we lay out key challenges, research gaps, and future opportunities based on our experience with digital twins that aim to serve as useful contributions towards a National Digital Twins R&D Strategic Plan. In the remaining document, we address nine of the thirteen topic areas specified in the RFI.

97 MATHEMATICS AND COMPUTING↗

Measured vs. Calculated Dose Rates During Ring Injection Dump Replacement

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is the ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H - beam, about 5% of the full SNS beam current, is discarded in the injection into the accumulator ring and is redirected to the RID. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID are removed and replaced when they have reached their end-of-life owing to radiation exposure. This procedure, which includes multiple steps, took place during a facility maintenance period in March 2023. To support work planning and meet as low as reasonably achievable (ALARA) requirements during removal and exchange of the components, dose rates were calculated for each stage of the exchange operation. During each stage, dose rates were measured before and after work. This comparison shows that measured dose rates are within a factor of 2 of the predicted (calculated) dose rates.

43 PARTICLE ACCELERATORS↗

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly

This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.

43 PARTICLE ACCELERATORS↗

Integrating Machine-learning-assisted Computer Vision with RICH System

Developments in artificial intelligence have vastly expanded the capabilities of robots. Currently, the Spallation Neutron Source (SNS) beamlines at Oak Ridge National Lab (ORNL) have robotic sample loaders to increase the efficiency of running experiments. However, they require retraining if anything about the situation changes, e.g., where the samples are, and cannot notice if errors occur. So, the viability of using computer vision and machine learning to enhance these sample loaders’ functionality was investigated. In this project, the RICH system with a Dobot CR3 6-axis robot present at the VULCAN beamline assisted by an Intel Realsense D435i camera, a unique camera that enables convenient translation of 2D pixel coordinates to 3D world points, was programmed to load ceramic crucibles into a thermogravimetric analyzer (TGA) furnace. An algorithm was constructed in Python with three major phases planned: (1) obtaining a sample, (2) moving it to the target location, and then (3) bringing the sample back to its original location once the experiment finished. In the first phase, the algorithm would dynamically detect sample locations using ArUco markers to recognize the samples’ general location and a custom-trained yolov5 object detection model to locate the crucibles’ centers. Afterward, the robot would be directed to pick up samples based on the crucibles’ calculated positions. In the second phase, the robot would move the sample to a secondary point, reorient its grip, and place the sample at the target location. In the final phase, the robot would determine whether the sample was intact and would bring it back to its original place if it was or raise an alarm. Using this algorithm, the robot was able to pick up different types of crucibles at varying positions. These results indicate that integrating machine-learning-assisted computer vision with robotic sample loaders can result in effective autonomous detection of samples.

97 MATHEMATICS AND COMPUTING↗

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗

Analyses of Dose Rates for Second Inner Reflector Plug Replacement at Spallation Neutron Source

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source (SNS) target monolith, which houses the liquid mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018 and next one, which is IRP2, is planned to be replaced during the facility maintenance period in the end of December 2025, beginning of January 2026 calendar year. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. For planning the replacement workflow to help to reduce radiation exposure to workers dose rates for each stage of extraction/replacement operation are predicted.

42 ENGINEERING↗

ESAC v1: Enhanced AI-Powered Chatbot for EQ-SANS Experiment Automation Improvements and Updates

ESAC (EQ-SANS Assisting Chatbot) is an advanced AI-powered application designed to streamline the workflow of neutron scattering experiments at the Spallation Neutron Source (SNS). This report documents the significant advancements in ESAC v1, which include the integration of a combined In-Context Learning (ICL) + Retrieval-Augmented Generation (RAG) capability, a robust integrated development environment, and standalone executable distribution. These enhancements address the limitations of the original version, making ESAC v1 a transformative tool for researchers. The report also discusses the technical challenges encountered during development and their resolution, highlighting the impact of these improvements on the neutron scattering research community.

36 MATERIALS SCIENCE↗

Application of SAMMY for Non-Destructive Characterization of Irradiated Samples Using Neutron Transmission Measurements at VENUS

This report presents the application of SAMMY (Larson 2008), an R-matrix Bayesian fitting system, for analyzing neutron transmission data to enable non-destructive isotopic identification. Transmission measurements were conducted at the VENUS (Bilheux et al. 2023) beamline of the Spallation Neutron Source (SNS) using samples with unknown or partially characterized compositions. Through the application of SAMMY’s R-matrix Bayesian fitting capabilities to the measured transmission spectra and comparison against evaluated nuclear data libraries, isotopic constituents can be quantitatively determined based on their characteristic neutron resonance signatures. This methodology demonstrates significant potential for applications in nuclear safeguards, forensics, and post-irradiation examination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗