Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral linewidths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Modification to Scott's method for direct integration of gaseous transmission to improve speed and accuracy

Two limitations to the method of Scott for rapid direct integration of gaseous transmission in a finite spectral interval over an inhomogeneous optical path are discussed. One of these is the inability to use a precomputed form of the Voigt line shape, which can be parameterized via the linewidth alone. This is rectified using the Voigt shape approximation of Kielkopf, which involves a linear combination of three functions which can be pre-computed: the Lorentz shape, the Doppler shape and a correction function. The other limitation involves situations where lines must be treated individually, either line positions must be known with great precision or a uniform value for the widths of all lines in the spectral interval does not describe the transmission adequately. In this case, the strongest lines are treated individually, while the remainder are treated assuming uniform line widths and line positions coincident with positions on the frequency grid, i.e. following Scott's method directly.

Orton, G. S.↗

Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dye laser traveling wave amplifier

Injection locking was applied to a cavity-dumped coaxial flashlamp pumped dye laser in an effort to obtain nanosecond duration pulses which have both high energy and narrow-linewidth. In the absence of an injected laser pulse, the cavity-dumped dye laser was capable of generating high energy (approx. 60mJ) nanosecond duration output pulses. These pulses, however, had a fixed center wavelength and were extremely broadband (approx. 6nm FWHM). Experimental investigations were performed to determine if the spectral properties of these outputs could be improved through the use of injection-locking techniques. A parametric study to determine the specific conditions under which the laser could be injection-locked was also carried out. Significant linewidth reduction to 0.0015nm) of the outputs was obtained through injection-locking but only at wavelengths near the peak lasing wavelength of the dye. It was found, however; that by inserting weakly dispersive tuning elements in the laser cavity, these narrow-linewidth outputs could be obtained over a wide (24nm) tuning range. Since the tuning elements had low insertion losses, the tunability of the output was obtained without sacrificing output pulse energy.

Davidson, F.↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Seven-core fibre Raman laser with intercore coupling

This paper reports results of a study aimed at producing a Raman fibre laser based on a multicore fibre with high-reflectivity fibre Bragg gratings inscribed in its peripheral cores using femtosecond laser pulses. We present spectral and power characteristics of a Raman laser whose output power at a wavelength of 1090 nm is 2.5 W. The laser emission linewidth has been shown to decrease as a result of the reduction in nonlinear effects owing to the larger effective mode area in the multicore fibre in comparison with a standard single-mode fibre Raman laser. (paper)

36 MATERIALS SCIENCE↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Probing electrolyte–silica interactions through simulations of the infrared spectroscopy of nanoscale pores

The structural and dynamical properties of nanoconfined solutions can differ dramatically from those of the corresponding bulk systems. Understanding the changes induced by confinement is central to controlling the behavior of synthetic nanostructured materials and predicting the characteristics of biological and geochemical systems. A key outstanding issue is how the molecular-level behavior of nanoconfined electrolyte solutions is reflected in different experimental, particularly spectroscopic, measurements. This is addressed here through molecular dynamics simulations of the OH stretching infrared (IR) spectroscopy of NaCl, NaBr, and NaI solutions in isotopically dilute HOD/D 2 O confined in hydroxylated amorphous silica slit pores of width 1–6 nm and pH ~2. In addition, the water reorientation dynamics and spectral diffusion, accessible by pump–probe anisotropy and two-dimensional IR measurements, are investigated. In this work, the aim is to elucidate the effect of salt identity, confinement, and salt concentration on the vibrational spectra. It is found that the IR spectra of the electrolyte solutions are only modestly blue-shifted upon confinement in amorphous silica slit pores, with both the size of the shift and linewidth increasing with the halide size, but these effects are suppressed as the salt concentration is increased. This indicates the limitations of linear IR spectroscopy as a probe of confined water. However, the OH reorientational and spectral diffusion dynamics are significantly slowed by confinement even at the lowest concentrations. The retardation of the dynamics eases with increasing salt concentration and pore width, but it exhibits a more complex behavior as a function of halide.

Mesoporous material↗

Homogeneous broadening in the spectrum of a broadband erbium-doped fibre light source

Interference of wave trains separated out in an inhomogeneous emission spectrum of a superluminescent erbium-doped fibre source has been studied by scanning the wavelength of a spectrum analyser. The results demonstrate that, as the spectral resolution of the spectrum analyser decreases to a level corresponding to a sharp drop in interference fringe visibility relative to its original level, near 100 %, fringe visibility becomes dependent on the wavelength in the inhomogeneous spectrum of the source. The reason for this is that, at some characteristic resolution δλ (δλ > 0.5 nm in our case), the coherence time of wave trains is not limited by the spectral resolution of the spectrum analyser and is related to the inhomogeneous spectrum of the source, whose limiting width can be thought of as the homogeneous linewidth in the spectrum of the source. This feature can be used for evaluating homogeneous line broadening. (paper)

74 ATOMIC AND MOLECULAR PHYSICS↗

Contributions to the optical linewidth of shallow donor-bound excitonic transition in ZnO

Neutral shallow donors in zinc oxide (ZnO) are spin qubits with optical access via the donor-bound exciton. This spin–photon interface enables applications in quantum networking, memories, and transduction. Essential optical parameters which impact the spin–photon interface include radiative lifetime, optical inhomogeneous and homogeneous linewidth, and optical depth. We study the donor-bound exciton optical linewidth properties of Al, Ga, and In donors in single-crystal ZnO. The ensemble photoluminescence linewidth ranges from 4 to 11 GHz, less than two orders of magnitude larger than the expected lifetime-limited linewidth. The ensemble linewidth remains narrow in absorption through samples with an estimated optical depth up to several hundred. The primary thermal relaxation mechanism is identified and found to have a negligible contribution to the total linewidth at 2 K. We find that inhomogeneous broadening due to the disordered isotopic environment in natural ZnO is significant, contributing 2 GHz. Two-laser spectral hole burning measurements indicate that the dominant mechanism, however, is homogeneous. Despite this broadening, the high homogeneity, large optical depth, and potential for isotope purification indicate that the optical properties of the ZnO donor-bound exciton are promising for a wide range of quantum technologies, and motivate a need to improve the isotope and chemical purity of ZnO for quantum technologies.

Niaouris, Vasileios (ORCID:000000015313748X)↗

Real-Frequency Response Functions at Finite Temperature

Building on previous developments [A. Taheridehkordi, S. H. Curnoe, and J. P. F. LeBlanc, Phys. Rev. B 99, 035120 (2019); A. Taheridehkordi, S. H. Curnoe, and J. P. F. LeBlancPhys. Rev. B101, 125109 (2020); A. Taheridehkordi, S. H. Curnoe, and J. P. F. LeBlancPhys. Rev. B102, 045115 (2020), B. Holm and U. von Barth, Phys. Rev. B 57, 2108 (1998), J. Vičičevic and M. Ferrero, Phys. Rev. B 101, 075113 (2020)], we show that the diagrammatic Monte Carlo technique allows us to compute finite-temperature response functions directly on the real-frequency axis within any field-theoretical formulation of the interacting fermion problem. There are no limitations on the type and nature of the system’s action or whether partial summation and self-consistent treatment of certain diagram classes are used. In particular, by eliminating the need for numerical analytic continuation from a Matsubara representation, our scheme allows us to study spectral densities of arbitrary complexity with controlled accuracy in models with frequency-dependent effective interactions. Finally, for illustrative purposes we consider the problem of the plasmon linewidth in a homogeneous electron gas (jellium).

3-dimensional systems↗

Analysis of mode-locked and intracavity frequency-doubled Nd:YAG laser

The paper presents analytical and computer studies of the CW mode-locked and intracavity frequency-doubled Nd:YAG laser which provide new insight into the operation, including the detuning behavior, of this type of laser. Computer solutions show that the steady-state pulse shape for this laser is much closer to a truncated cosine than to a Gaussian; there is little spectral broadening for on-resonance operation; and the chirp is negligible. This leads to a simplified analytical model carried out entirely in the time domain, with atomic linewidth effects ignored. Simple analytical results for on-resonance pulse shape, pulse width, signal intensity, and harmonic conversion efficiency in terms of basic laser parameters are derived from this model. A simplified physical description of the detuning behavior is also developed. Agreement is found with experimental studies showing that the pulsewidth decreases as the modulation frequency is detuned off resonance; the harmonic power output initially increases and then decreases; and the pulse shape develops a sharp-edged asymmetry of opposite sense for opposite signs of detuning.

Siegman, A. E.↗

Improved spectroscopic line parameters for the ozone molecule

Recently available spectral O3 line parameters are summarized and progress in remote sensing based on these parameters is discussed. Particular attention is given to covering line positions, line intensities and linewidths for both the main isotopic species (O-16)3 and the isotopic variants (O-16)(O-18)(O-16) and (O-16)(O-16)(O-18).

Flaud, J.-M.↗

Passive Microwave Spectral Imaging of Amospheric Structure

The primary objective of this research was to improve the scientific foundation necessary to full realization of the meteorological potential of the NOAA Advanced Microwave Sounding Unit (AMSU) recently first launched on the NOAA-15 satellite in May, 1998. These advances were made in four main areas: (1) improvements, based on aircraft observations, in the atmospheric transmittance expressions used for interpreting AMSU and similar data; (2) development of neural network retrieval methods for cloud top altitude estimates of approximately 1-km accuracy under cirrus shields--the altitude is that of the larger ice particles aloft, which is related to precipitation rate; (3) analysis of early AMSU flight data with respect to its precipitation sensitivity and fine-scale thermal structure; and (4) improvements to the 54-GHz and 118-GHz MTS aircraft imaging spectrometer now operating on the NASA ER-2 aircraft. More specifically, the oxygen transmittance expressions near 118 GHz were in better agreement with aircraft data when the temperature dependence exponent of the 118.75-GHz linewidth was increased from the MPM92 value (Liebe et al., 1992) of 0.8 to 0.97+/-0.03. In contrast, the observations 52.5-55.8 GHz were consistent with the MPM92 model. Neural networks trained on comparisons of 118-GHz spectral data and coincident stereoscopic video images of convective cells observed from 20-km altitude yielded agreement in their peak altitudes within as little as 1.36 km rms, much of which is stereoscopic error. Imagery using these methods produced useful characterizations for Cyclone Oliver in 1993 and other storms (Schwartz et al., 1996; Spina et al., 1998). Similar neural network techniques yielded simulated rms errors in relative humidity retrievals of 6-14 percent over ocean and 6-15 percent over land at pressure levels from 1013 to 131 mbar (Cabrera-Mercader and Staelin, 1995).

Staelin, David H.↗

Intensity and linewidth measurements in the 13.7-micron fundamental bands of (C-12)2H2 and (C-12)(C-13)H2 at planetary atmospheric temperatures

The absolute intensities and collision-broadened half-widths of several lines in the P-,Q-, and R-branches of the nu5-fundamental band of (C-12)2H2 have been measured at various temperatures between 147 and 295 K employing the Doppler-limited spectral resolution (about 10 exp -4/cm) of a tunable diode laser spectrometer. The absolute intensities of R(5), R(7), R(9), and R(20) in the same fundamental belonging to (C-12)(C-13)H2 have also been measured at 294 K. The temperature dependence of the collision-broadened half-width has been determined for some of the lines broadened by planetary atmospheric gases, namely, He, Ar, H2, and N2. Four self-broadened linewidths of (C-12)2H2, as well as three H2-broadened linewidths and a self-broadened half-width of (C-12)(C-13)H2, have also been retrieved from the measurements.

Varanasi, Prasad↗