Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Theory of strain phase equilibria and diagrams

Chemical phase equilibria and phase diagrams are well established and have served as indispensable guides for designing materials through chemical tuning. However, a general thermodynamic theory for strain phase equilibria remains elusive despite extensive studies which have revealed dramatic impacts of mechanical strain on the stability of phases and domain states in solid-state materials. Here, we establish the thermodynamic theory of strain equilibria and a general framework for efficiently constructing multidomain and multiphase diagrams of arbitrarily strained solids under incoherent conditions. As examples, we obtain temperature-strain phase diagrams of ferroelectric PbTiO 3 , strongly correlated VO 2 , and unconventional ferroelectric Hf 0.5 Zr 0.5 O 2 . We reveal the analogs of the Gibbs phase rules, multiple- and multi-critical points, common-tangent construction, and level rule in strain equilibria to those in the familiar chemical phase equilibria. Finally, our strain equilibria theory offers a powerful framework for predicting the thermodynamic stability of structural phases and domains in strained solids and for guiding the strain engineering of their functional properties.

36 MATERIALS SCIENCE↗

The classical-to-quantum crossover in the strain-induced ferroelectric transition in SrTiO3 membranes

Mechanical strain presents an effective control over symmetry-breaking phase transitions. In quantum paralelectric SrTiO3, strain can induce ferroelectric order via modification of the local Ti potential energy landscape. However, brittle bulk materials can only withstand limited strain range (~0.1%). Taking advantage of nanoscopically-thin freestanding membranes, we demonstrate an in- situ strain-induced reversible ferroelectric transition in freestanding SrTiO3 membranes. We measure the ferroelectric order by detecting the local anisotropy of the Ti 3d orbital signature using x-ray linear dichroism at the Ti-K pre-edge, while the strain is determined by x-ray diffraction. With reduced thickness, the SrTiO3 membranes remain elastic with >1% tensile strain cycles. A robust displacive ferroelectricity appears beyond a temperature-dependent critical strain. Interestingly, we discover a crossover from a classical ferroelectric transition to a quantum regime at low temperatures, which enhances strain-induced ferroelectricity. Our results offer new opportunities to strain engineer functional properties in low dimensional quantum materials and provide new insights into the role of ferroelectric fluctuations in quantum paraelectric SrTiO3.

36 MATERIALS SCIENCE↗

Stroboscopic x-ray diffraction microscopy of dynamic strain in diamond thin-film bulk acoustic resonators for quantum control of nitrogen-vacancy centers

Bulk-mode acoustic waves in a crystalline material exert lattice strain through the thickness of the sample, which couples to the spin Hamiltonian of defect-based qubits such as the nitrogen-vacancy (N-V) center defect in diamond. This mechanism has previously been harnessed for unconventional quantum spin control, spin decoherence protection, and quantum sensing. Bulk-mode acoustic wave devices are also important in the microelectronics industry as microwave filters. A key challenge in both applications is a lack of appropriate operando microscopy tools for quantifying and visualizing gigahertz-frequency dynamic strain. Here, in this work, we directly image acoustic strain within N-V center-coupled diamond thin-film bulk acoustic wave resonators using stroboscopic scanning hard x-ray diffraction microscopy at the Advanced Photon Source. The far-field scattering patterns of the nanofocused x-ray diffraction encode strain information entirely through the illuminated thickness of the resonator. These patterns have a real-space spatial variation that is consistent with the bulk strain’s expected modal distribution and a momentum-space angular variation from which the strain amplitude can be quantitatively deduced. We also perform optical measurements of strain-driven Rabi precession of of the N-V center spin ensemble, providing an additional quantitative measurement of the strain amplitude. As a result, we directly measure one of the six N-V spin-stress coupling parameters, 𝑏 =2.73⁢(2) MHz/GPa, by correlating these measurements at the same spatial position and applied microwave power. Our results demonstrate a unique technique for directly imaging ac lattice strain in micromechanical structures and provide a direct measurement of a fundamental constant for the N-V center defect spin Hamiltonian.

acoustic techniques↗

Distributed strain sensing using Bi-metallic coated fiber optic sensors embedded in stainless steel

Silica fiber optic sensors are resistant to corrosive environments and high temperatures, making them attractive candidates for harsh conditions found in nuclear and aerospace industries. Moreover, fibers can be deployed remotely for continuous measuring of spatially distributed temperatures and strains. Here, this study investigated embedding a Ni/Cu bi-metallic coated fiber in a stainless-steel 316 (SS316) matrix using laser powder bed fusion towards functionalizing metal components for site-specific health monitoring. The embedded fiber was continuously interrogated during controlled heating to 1000°C. The measured fiber strains were similar to the expected differential thermal strains between the fiber and the SS316 matrix, until divergent behavior was observed at temperatures >500°C. No debonding at the matrix–coating–fiber interfaces was observed during microscopy, but significant interactions between the coatings and matrix resulted in diffusion-driven chemistry variations and Kirkendall void formation. Applying the strain-lag theory revealed plastic behavior in the Ni coating at temperatures >500°C, limiting the strain transfer to the fiber at higher temperatures. It was estimated that the elastic modulus in the Ni coating had decreased from ~200 GPa at room temperature to below 40 GPa, starting at 600°C. The low elastic modulus above 600°C is within the margin of what the tangent modulus would be in the case of bilinear isotropic hardening. Regardless of the divergent strain transfer at higher temperatures, the fiber was exposed to the equivalent of 1.9 % engineering strain at 1000°C, but measured only a 0.7 % engineering strain due to the poor strain transfer. Although compensating for the plastic behavior of Ni proved challenging, the bonding of a brittle silica fiber to a metal matrix surviving to 1000°C invites potential iterations on coating material for future application. For example, the embedded fiber is sufficient for acoustic energy transfer, realizing high temperature distributed acoustic sensing.

36 MATERIALS SCIENCE↗

High phenotypic and genotypic plasticity among strains of the mushroom-forming fungus Schizophyllum commune

Schizophyllum commune is a mushroom-forming fungus notable for its distinctive fruiting bodies with split gills. It is used as a model organism to study mushroom development, lignocellulose degradation and mating type loci. It is a hypervariable species with considerable genetic and phenotypic diversity between the strains. In this study, we systematically phenotyped 16 dikaryotic strains for aspects of mushroom development and 18 monokaryotic strains for lignocellulose degradation. There was considerable heterogeneity among the strains regarding these phenotypes. The majority of the strains developed mushrooms with varying morphologies, although some strains only grew vegetatively under the tested conditions. Growth on various carbon sources showed strain-specific profiles. The genomes of seven monokaryotic strains were sequenced and analyzed together with six previously published genome sequences. Moreover, the related species Schizophyllum fasciatum was sequenced. Although there was considerable genetic variation between the genome assemblies, the genes related to mushroom formation and lignocellulose degradation were well conserved. These sequenced genomes, in combination with the high phenotypic diversity, will provide a solid basis for functional genomics analyses of the strains of S. commune.

59 BASIC BIOLOGICAL SCIENCES↗

Discovery of spontaneous mesoscopic strain waves in nematic domains using dark-field x-ray microscopy

Electronic nematic order arises when correlated electrons spontaneously break the rotational symmetry of a crystal lattice. When electronic nematic order couples bilinearly to symmetry-breaking lattice strain, both appear together at a single ferroelastic phase transition, producing structural twin domains with distinct orientations of the nematic director. While the effects of applied strain on these domains are well established, the intrinsic behavior of spontaneous subdomain strain fields has remained unexplored. Here, we report the discovery of spontaneous mesoscopic strain waves within individual nematic domains of an iron-based superconductor, observed using dark-field x-ray microscopy (DFXM). Using this advanced full-field imaging technique, we visualize subdomain strain modulations emerging concurrently with nematic order. Elastic compatibility relations governing inhomogeneous strains provide a natural mechanism for the strain waves. Our findings reveal a broadly relevant form of strain self-organization and position DFXM as a powerful probe of the local interplay between lattice strain and electronic order.

36 MATERIALS SCIENCE↗

Recent experience with elevated-temperature foil strain gages with application to thin-gage materials

The effects of thin-gage materials on high-temperature strain measurements are discussed. Apparent strain test were performed using facesheet coupons, honeycomb coupons, and the panel with strain gages in an installed condition. The apparent strain results differed in each of the cases. The apparent strain curves from the panel tests are expected to provide the best correlation with analysis, assuming that the thermal strains are insignificant or that the thermal strains derived from the analysis of the apparent strain test performed on the panel can be used to correct the apparent strain curves.

Hudson, Larry D.↗

Evaluation of Pd-Cr Wires for Strain Gage Application

A newly developed alloy, palladium-13 weight percent chromium (Pd13Cr), was identified by United Technologies Research Center under a NASA contract to be the best material for high temperature strain gage applications. An electrical resistance strain gage that can provide accurate static strain measurement to a temperature higher than that of a commercially available gage is urgently needed in aerospace and aeronautics research. A strain gage made of a 25.4 micron (1 mil) diameter Pd13Cr wire has been recently demonstrated to be usable for static strain measurements to 800 C. This compares to the 400 C temperature limit of the commercially available strain gages. The performance of the Pd-Cr gage, however, strongly depends on the quality of the Pd13Cr wire. Four batches of Pd-Cr wires purchased from three different manufacturers were therefore evaluated to determine the best source of the wire for strain gage applications. The three suppliers were Precious Metal Institute in China, Sigmund Cohn Co., and G & S Titanium, Inc. in the United States. Two batches of wires obtained from Previous Metal Institute in 1987 and 1992, respectively are referred to herein as China87 and China92 wires. The mechanical, chemical and electrical properties of these wires, both as-received and after high temperature exposures at 800 C for 50 hours were analyzed. The elastic modulus and the failure strength of the wires were evaluated using a tensile test machine equipped with a laser speckle strain measurement system. The chemical and microstructural properties of the wires were inspected using a plasma atomic emission spectrometer and a scanning electron microscope (SEM) equipped with an energy dispersive X-ray spectroscope (EDS). The electrical stability and repeatability of the wires were determined by measuring the electrical resistance of the wires during three thermal cycles to 1000 C and a ten-hour soak at 1000 C. As a result of this study, the wire which has the highest strength, the least impurities content, the best oxidation resistance and the best electrical stability will be selected for upcoming strain gage applications.

Lei, Jih-Fen↗

A New Correction Technique for Strain-Gage Measurements Acquired in Transient-Temperature Environments

Significant strain-gage errors may exist in measurements acquired in transient-temperature environments if conventional correction methods are applied. As heating or cooling rates increase, temperature gradients between the strain-gage sensor and substrate surface increase proportionally. These temperature gradients introduce strain-measurement errors that are currently neglected in both conventional strain-correction theory and practice. Therefore, the conventional correction theory has been modified to account for these errors. A new experimental method has been developed to correct strain-gage measurements acquired in environments experiencing significant temperature transients. The new correction technique has been demonstrated through a series of tests in which strain measurements were acquired for temperature-rise rates ranging from 1 to greater than 100 degrees F/sec. Strain-gage data from these tests have been corrected with both the new and conventional methods and then compared with an analysis. Results show that, for temperature-rise rates greater than 10 degrees F/sec, the strain measurements corrected with the conventional technique produced strain errors that deviated from analysis by as much as 45 percent, whereas results corrected with the new technique were in good agreement with analytical results.

Richards, W. Lance↗

Natural Strain

The purpose of this paper is to present a consistent and thorough development of the strain and strain-rate measures affiliated with Hencky. Natural measures for strain and strain-rate, as I refer to them, are first expressed in terms of of the fundamental body-metric tensors of Lodge. These strain and strain-rate measures are mixed tensor fields. They are mapped from the body to space in both the Eulerian and Lagrangian configurations, and then transformed from general to Cartesian fields. There they are compared with the various strain and strain-rate measures found in the literature. A simple Cartesian description for Hencky strain-rate in the Lagrangian state is obtained.

Freed, Alan D.↗

Thermal Output of WK-Type Strain Gauges on Various Materials at Cryogenic and Elevated Temperatures

Strain gage apparent strain (thermal output) is one of the largest sources of error associated with the measurement of strain when temperatures and mechanical loads are varied. In this paper, experimentally determined apparent strains of WK-type strain gages, installed on both metallic and composite-laminate materials of various lay-ups and resin systems for temperatures ranging from -450 F to 230 F are presented. For the composite materials apparent strain in both the 0 ply orientation angle and the 90 ply orientation angle were measured. Metal specimens tested included: aluminum-lithium alloy (Al-LI 2195-T87), aluminum alloy (Al 2219-T87), and titanium alloy. Composite materials tested include: graphite-toughened-epoxy (IM7/997- 2), graphite-bismaleimide (IM7/5260), and graphite-K3 (IM7/K3B). The experimentally determined apparent strain data are curve fit with a fourth-order polynomial for each of the materials studied. The apparent strain data and the polynomials that are fit to the data are compared with those produced by the strain gage manufacturer, and the results and comparisons are presented. Unacceptably high errors between the manufacture's data and the experimentally determined data were observed (especially at temperatures below - 270-F).

Kowalkowski, Matthew K.↗

Exercise Countermeasures for Bone Loss During Space Flight: A Method for the Study of Ground Reaction Forces and their Implications for Bone Strain

Effective countermeasures to prevent loss of bone mineral during long duration space flight remain elusive. Despite an exercise program on MIR flights, the data from LeBlanc et al. (1996) indicated that there was still a mean rate of loss of bone mineral density in the proximal femur of 1.58% per month (n=18, flight duration 4 - 14.4 months). The specific mechanisms regulating bone mass are not known, but most investigators agree that bone maintenance is largely dependent upon mechanical demand and the resultant local bone strains. A plausible hypothesis is that bone loss during space flight, such as that reported by LeBlanc et al. (1996), may result from failure to effectively load the skeleton in order to generate localized bone strains of sufficient magnitude to prevent disuse osteoporosis. A variety of methods have been proposed to simulate locomotor exercise in reduced gravity. In such simulations, and in an actual microgravity environment, a gravity replacement load (GRL) must always be added to return the exercising subject to the support surface and the resulting skeletal load is critically dependent upon the magnitude of the GRL. To our knowledge, GRLs during orbital flight have only been measured once (on STS 81) and it is likely that most or all prior treadmill exercise in space has used GRLs that were less than one body weight. McCrory (1997) has shown that subjects walking and running in simulated zero-G can tolerate GRLs of 1 if an appropriate harness is used. Several investigators have attempted to measure in vivo strains and forces in the bones of humans, but have faced ethical and technical limitations. The anteromedial aspect of the tibial midshaft has been a common site for the placement of strain gauges; one reason to measure strains in the anterior tibia is that this region is surgically accessible. Aamodt et al. (1997) were able to measure strains on the lateral surface of the proximal femur only because their experimental subjects were already scheduled for hip surgery. Lu et al. (1997) used an instrumented massive proximal femoral prosthesis along with electromyographic measurements to demonstrate that femoral forces depend on muscular activity. These analyses of in vivo bone mechanics are valuable. The invasive nature of the procedures involved, however, limits both the number of subjects and the number of strain gauge locations. Further, the results of these studies may be confounded by the inclusion of subjects with pathological conditions. Gross et al. (1992) measured strain at three locations on the equine third metacarpal and used those data to construct a computer model of the internal strain environment of the bone. An analogous placement of multiple gauges in living humans would be difficult and potentially hazardous because of the depth of soft tissue overlying the tibia and femur.

Peterman, M.↗

Analytical Modeling of the High Strain Rate Deformation of Polymer Matrix Composites

The results presented here are part of an ongoing research program to develop strain rate dependent deformation and failure models for the analysis of polymer matrix composites subject to high strain rate impact loads. State variable constitutive equations originally developed for metals have been modified in order to model the nonlinear, strain rate dependent deformation of polymeric matrix materials. To account for the effects of hydrostatic stresses, which are significant in polymers, the classical 5 plasticity theory definitions of effective stress and effective plastic strain are modified by applying variations of the Drucker-Prager yield criterion. To verify the revised formulation, the shear and tensile deformation of a representative toughened epoxy is analyzed across a wide range of strain rates (from quasi-static to high strain rates) and the results are compared to experimentally obtained values. For the analyzed polymers, both the tensile and shear stress-strain curves computed using the analytical model correlate well with values obtained through experimental tests. The polymer constitutive equations are implemented within a strength of materials based micromechanics method to predict the nonlinear, strain rate dependent deformation of polymer matrix composites. In the micromechanics, the unit cell is divided up into a number of independently analyzed slices, and laminate theory is then applied to obtain the effective deformation of the unit cell. The composite mechanics are verified by analyzing the deformation of a representative polymer matrix composite (composed using the representative polymer analyzed for the correlation of the polymer constitutive equations) for several fiber orientation angles across a variety of strain rates. The computed values compare favorably to experimentally obtained results.

Goldberg, Robert K.↗

In vitro modeling of human tibial strains during exercise in micro-gravity

Prolonged exposure to micro-gravity causes substantial bone loss (Leblanc et al., Journal of Bone Mineral Research 11 (1996) S323) and treadmill exercise under gravity replacement loads (GRLs) has been advocated as a countermeasure. To date, the magnitudes of GRLs employed for locomotion in space have been substantially less than the loads imposed in the earthbound 1G environment, which may account for the poor performance of locomotion as an intervention. The success of future treadmill interventions will likely require GRLs of greater magnitude. It is widely held that mechanical tissue strain is an important intermediary signal in the transduction pathway linking the external loading environment to bone maintenance and functional adaptation; yet, to our knowledge, no data exist linking alterations in external skeletal loading to alterations in bone strain. In this preliminary study, we used unique cadaver simulations of micro-gravity locomotion to determine relationships between localized tibial bone strains and external loading as a means to better predict the efficacy of future exercise interventions proposed for bone maintenance on orbit. Bone strain magnitudes in the distal tibia were found to be linearly related to ground reaction force magnitude (R(2)>0.7). Strain distributions indicated that the primary mode of tibial loading was in bending, with little variation in the neutral axis over the stance phase of gait. The greatest strains, as well as the greatest strain sensitivity to altered external loading, occurred within the anterior crest and posterior aspect of the tibia, the sites furthest removed from the neutral axis of bending. We established a technique for estimating local strain magnitudes from external loads, and equations for predicting strain during simulated micro-gravity walking are presented.

NASA Discipline Musculoskeletal↗

Long-term measurement of bone strain in vivo: the rat tibia

Despite the importance of strain in regulating bone metabolism, knowledge of strains induced in bone in vivo during normal activities is limited to short-term studies. Biodegeneration of the bond between gauge and bone is the principle cause of this limitation. To overcome the problem of bond degeneration, a unique calcium phosphate ceramic (CPC) coating has been developed that permits long-term attachment of microminiature strain gauges to bone. Using this technique, we report the first long-term measurements of bone strain in the rat tibia. Gauges, mounted on the tibia, achieved peak or near peak bonding at 7 weeks. Measurements were made between 7-10 weeks. Using ambulation on a treadmill, the pattern and magnitude of strain measured in the tibia remained relatively constant between 7-10 weeks post implantation. That strain levels were similar at 7 and 10 weeks suggests that gauge bonding is stable. These data demonstrate that CPC-coated strain gauges can be used to accurately measure bone strain for extended periods, and provide an in vivo assessment of tibial strain levels during normal ambulation in the rat. Copyright 2001 John Wiley & Sons, Inc.

Non-programmatic↗

High-Temperature, Thin-Film Strain Gages Improved

Conventional resistance strain gage technology uses "bonded" strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow. The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of minimally intrusive surface strain measurements and give highly repeatable readings with low drift at temperatures from ambient to 1100 C. This is a 300 C advance in operating temperature over the PdCr wire gage and a 500 C advance over commercially available gages made of other materials.

Source record↗

Hydrostatic Stress Effects Incorporated Into the Analysis of the High-Strain-Rate Deformation of Polymer Matrix Composites

Procedures for modeling the effect of high strain rate on composite materials are needed for designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. The nonlinearity and strain rate dependence of the composite response is primarily due to the matrix constituent. Therefore, in developing material models to be used in the design of impact-resistant composite engine cases, the deformation of the polymer matrix must be correctly analyzed. However, unlike in metals, the nonlinear response of polymers depends on the hydrostatic stresses, which must be accounted for within an analytical model. An experimental program has been carried out through a university grant with the Ohio State University to obtain tensile and shear deformation data for a representative polymer for strain rates ranging from quasi-static to high rates of several hundred per second. This information has been used at the NASA Glenn Research Center to develop, characterize, and correlate a material model in which the strain rate dependence and nonlinearity (including hydrostatic stress effects) of the polymer are correctly analyzed. To obtain the material data, Glenn s researchers designed and fabricated test specimens of a representative toughened epoxy resin. Quasi-static tests at low strain rates and split Hopkinson bar tests at high strain rates were then conducted at the Ohio State University. The experimental data confirmed the strong effects of strain rate on both the tensile and shear deformation of the polymer. For the analytical model, Glenn researchers modified state variable constitutive equations previously used for the viscoplastic analysis of metals to allow for the analysis of the nonlinear, strain-rate-dependent polymer deformation. Specifically, we accounted for the effects of hydrostatic stresses. An important discovery in the course of this work was that the hydrostatic stress effects varied during the loading process, which needed to be accounted for within the constitutive equations. The model is characterized primarily by shear data, with tensile data used to characterize the hydrostatic stress effects.

Goldberg, Robert K.↗

The Compressive Behavior of Isocyanate-crosslinked Silica Aerogel at High Strain Rates

Aerogels are low-density, highly nano-porous materials. Their engineering applications are limited due to their brittleness and hydrophilicity. Recently, a strong lightweight crosslinked silica aerogel has been developed by encapsulating the skeletal framework of amine-modified silica aerogels with polyureas derived by isocyanate. The mesoporous structure of the underlying silica framework is preserved through conformal polymer coating, and the thermal conductivity remains low. Characterization has been conducted on the thermal, physical properties and the mechanical properties under quasi-static loading conditions. In this paper, we present results on the dynamic compressive behavior of the crosslinked silica aerogel (CSA) using a split Hopkinson pressure bar (SHPB). A new tubing pulse shaper was employed to help reach the dynamic stress equilibrium and constant strain rate. The stress-strain relationship was determined at high strain rates within 114-4386/s. The effects of strain rate, density, specimen thickness and water absorption on the dynamic behavior of the CSA were investigated through a series of dynamic experiments. The Young's moduli (or 0.2% offset compressive yield strengths) at a strain rate approx.350/s were determined as 10.96/2.08, 159.5/6.75, 192.2/7.68, 304.6/11.46, 407.0/20.91 and 640.5/30.47 MPa for CSA with densities 0.205, 0.454, 0.492, 0.551,0.628 and 0.731 g/cu cm, respectively. The deformation and failure behaviors of a native silica aerogel with density (0.472 g/cu cm ), approximately the same as a typical CSA sample were observed with a high speed digital camera. Digital image correlation technique was used to determine the surface strains through a series of images acquired using high speed photography. The relative uniform axial deformation indicated that localized compaction did not occur at a compressive strain level of approx.17%, suggesting most likely failure mechanism at high strain rate to be different from that under quasi-static loading condition. The Poisson s ratio was determined to be 0.162 in nonlinear regime under high strain rates. CSA samples failed generally by splitting, but were much more ductile than native silica aerogels.

Luo, H.↗