Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stream temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Stagnation region gas film cooling: Effects of dimensionless coolant temperature

An experimental investigation was conducted to mode the film cooling performance for a turbine vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio and dimensionless coolant temperature with free stream-to-wall temperature ratio approximately 1.7 and Re sub D = 90000. the cylindrical test surface was instrumented with miniature heat flux gages and wall thermocouples to determine the percentage reduction in the Stanton number as a function of the distance downstream from injection (x/d sub 0) and the location between adjacent holes (z/S). Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, from stagnation using a hole spacing ratio of S/d = 5. The film coolant was injected with T sub c T sub w with a dimensionless coolant temperature in the range 1.18 or equal to theta sub c or equal to 1.56. The data for local Stanton Number Reduction (SNR) showed a significant increase in SNR as theta sub c was increased above 1.0.

Bonnice, M. A.↗

Hyperspectral Microwave Atmospheric Sounder (HyMAS) Architecture and Design Accommodations

The Hyperspectral Microwave Atmospheric Sounder (HyMAS) is being developed at Lincoln Laboratories and accommodated by the Goddard Space Flight Center for a flight opportunity on a NASA research aircraft. The term "hyperspectral microwave" is used to indicate an all-weather sounding that performs equivalent to hyperspectral infrared sounders in clear air with vertical resolution of approximately 1 km. Deploying the HyMAS equipped scanhead with the existing Conical Scanning Microwave Imaging Radiometer (CoSMIR) shortens the path to a flight demonstration. Hyperspectral microwave is achieved through the use of independent RF antennas that sample the volume of the Earth s atmosphere through various levels of frequencies, thereby producing a set of dense, spaced vertical weighting functions. The simulations proposed for HyMAS 118/183-GHz system should yield surface precipitation rate and water path retrievals for small hail, soft hail, or snow pellets, snow, rainwater, etc. with accuracies comparable to those of the Advanced Technology Microwave Sounder. Further improvements in retrieval methodology (for example, polarization exploitation) are expected. The CoSMIR instrument is a packaging concept re-used on HyMAS to ease the integration features of the scanhead. The HyMAS scanhead will include an ultra-compact Intermediate Frequency Processor (IFP) module that is mounted inside the door to improve thermal management. The IFP is fabricated with materials made of Low-Temperature Co-fired Ceramic (LTCC) technology integrated with detectors, amplifiers, A/D conversion and data aggregation. The IFP will put out 52 channels of 16 bit data comprised of 4-9 channel data streams for temperature profiles and 2-8 channel streams for water vapor. With the limited volume of the existing CoSMIR scanhead and new HyMAS front end components, the HyMAS team at Goddard began preliminary layout work inside the new drum. Importing and re-using models of the shell, the scan head computer, and the slip rings developed for CoSMIR was the starting point. The next step was to modify the antenna faceplate to accommodate the dimensions of the three dual polarization Gaussian Optics Antenna (GOA) assemblies. Two mechanical concepts for the core technology, the hyperspectral IFP, were captured in a design tradeoff. Connector models considered minimum bend radii for the IFP analog connectors. Hyperspectral imaging is accomplished by strategically using a short wavelength intermediate frequency of 18-29 GHz, and thus reducing the size of components in the connection of the front end to the IFP. The SMK (2.92mm) Series connector will lay near the hinge line to minimize its flexing. The digital output of the IFP will use a Serial Peripheral Interface (SPI) that must be accommodated by the scan head computer. To make that computer more reliable, maintainable, and forward compatible with the 52 HyMAS channels, a testbed of the scan head, calibration, and archive computers and the PIC24 microprocessor that resides on the IFP is in development. The computers will be programmed using a new framework application called Interoperable Remote Component (IRC). This software allows flexibility to program computers that communicate with each other and can adapt easily to the emerging HyMAS requirements for data format, algorithms, and graphical user interface (GUI). It is expected that the CoSMIR instrument will cut over to the IRC after it is adapted on an updated CoSMIR testbed.

Hilliard, Lawrence↗

A fast-response aspirating probe for measurements of total temperature and pressure in transonic cryogenic wind tunnel

A newly developed, 3-mm-diam, dual hot-wire aspirating probe was used to measure the time-resolved stagnation temperature and pressure in a transonic cryogenic wind tunnel. The probe consists of two coplanar constant temperature hot wires at different overheat ratios operating in a 1.5-mm-diam channel with a choked exit. Thus, the constant Mach number flow by the wires is influenced only by free-stream stagnation temperature and pressure. Diffusion of the free-stream Mach number to a lower value in the channel reduces the dynamic drag on the hot-wire. Frequency response of the present design is dc to 20 kHz. The probe was used to measure the unsteady wake shed from an oscillating airfoil tested in the 0.3-m Transonic Cryogenic Tunnel at NASA-Langley Research Center. The hot-wire lasted for more than ten hours before breaking, proving the ruggedness of the probe and the usefulness of the technique in a high dynamic pressure, transonic cryogenic wind tunnel. Typical data obtained from the experiment are presented after reduction to stagnation pressure and temperature.

Ng, W.-F.↗

X-RAY DENSITOMETER FOR USE IN PLASMA STREAMS

Densitometer for the measurement of mass density of a gas in a localized volume element with application to density measurements in high temperature gas streams

X-RAY DENSITY MEASUREMENT↗

Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"

This data package contains the associated data and scripts for Nagamoto, E., Ombadi, M., Ciulla, F. et al. Widespread drought-driven declines in streamflows and water quality in the Upper Colorado River Basin during 1998-2022. Commun Earth Environ 7, 734 (2026). https://doi.org/10.1038/s43247-026-03890-5. This purpose of this study was to investigate the impact of the 21st century drought on water quantity and quality at catchments throughout the Upper Colorado River Basin (UCRB). We used stream flow, water temperature, specific conductance, air temperature, precipitation, and catchment attribute data for over 200 sites in the UCRB, collected from the National Water Information System using Basin3D (Varadharajan, 2023), GAGESII (Falcone, 2010), and the Google Earth Engine. We identified years of severe drought between 1998 and 2022 using the Standardized Precipitation Evaporation Index (SPEI), then calculated the relative change percentage of the stream flow, water temperature, and specific conductance from drought versus non-drought years. We used the attribute information from GAGESII to investigate what physical traits of catchments are associated streamflow vulnerability (greater relative change) or resilience to drought. We used land cover data from the National Land Cover Database (USGS, 2024) to assess any changes to physical attributes that may not be represented in the static attributes information in GAGESII. To increase data availability, we modeled stream temperature using methods from Willard, 2023. While the study period is water years 1998 to 2022, the raw water quantity and quality data extends to 1950 and the meteorological data extends to 1980. The data and code can be downloaded via the UCRB_drought.zip. Within the zip, the files are organized as follows: - INPUTS: Contains all input data used in UCRB_Drought_Workflow.ipynb - OUTPUTS: Contains all intermediate data created from UCRB_Drought_Workflow.ipynb as well as final products including the calculated Standardized Evapotranspiration Index (SPEI) - climatic_variables: The code used to collect meteorologic data from Google Earth Engine - feature_importance: The code used for the catchment attributes analysis - preprocessing: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - pyeto: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - calculations: Code used in UCRB_Drought_Workflow_Impacts.ipynb - plotting: Code used in UCRB_Drought_Workflow_Impacts.ipynb - README.md - UCRB_Drought_Workflow_Preprocessing.ipynb: The code used to prep raw data for the analysis - UCRB_Drought_Workflow_Impact.ipynb: The code which uses the prepped raw data for analysis, and plots all figures - requirements_ucrb-drought_v2.yml: The requirements file to create a virtual environment and Jupyter Lab kernel to run the code The INPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_RAW" folder contains raw data for streamflow, water temperature, and specific conductance in a ".h5" file. The "NLCD_RAW" folder contains ".csv" files with annual land cover percentages for counties within the UCRB. The "MET_RAW" folder contains a ".csv" file with monthly meteorological data (air temperature and precipitation) for the sites in the UCRB which was obtained from code in the climatic_variables folder. The "GAGESII" folder contains ".csv" files with physical catchment attribute variables for catchments across the country. The "WT_LSTM_data" folder contains ".csv" files with calculated WT (Willard, 2023) and the associated RMSEs. The "Upper_Colorado_River_Basin_Boundary" folder contains geographic data including a shapefile for plotting in the UCRB_Drought_Workflow.ipynb. The "RESERVOIRS_RAW" folder contains ".csv" files for each reservoir in the UCRB with daily reservoir storage. There are also two files in the INPUTS folder that have combined reservoir storage data and reservoir metadata. The OUTPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_data" folder contains a folder "Water_year" with the associated cleaned data, metadata, and data availability information in ".csv" files, a folder "Median_Relchange" with the relative change comparing drought to non-drought years in ".csv" files, and a folder "Peak95_Min5_Relchange" that has ".csv" files for the relative change in peak (95th %) and minimum (5th %) variables. The "NLCD_data" folder contains the difference in land cover from the beginning to end of the study period and the percentage of the county that is within UCRB bounds can be found in Nagamoto et al (2025)). The "MET_data" folder contains separated monthly air temperature and precipitation data and the calculated PET in ".csv" files. The "SPEI_data" folder contains ".csv" files with calculated SPEI values (one restricted to the study period and the other with information from the entire MET data period). The "Paper_Tables" folder contains two ".csv" files containing site information and data availability and information about the GAGESII trait aggregated categories. The base directory includes the file “flmd.csv” for a list and description of all files and the file “dd.csv” for data dictionaries. Scripts for preprocessing, analysis, and figure generation are located in the associated GitHub repository found at [https://github.com/iNAIADS/drought-impacts/tree/develop/UCRB-drought]. UPDATE 1: Title and code file updated to match submitted manuscript 10-15-2025. UPDATE 2: Code and data files updated to match revised manuscript 3-4-2026. UPDATE 3: Code and data files updated to match revised manuscript 6-7-2026. ** NOTE: DD and FLMD have not been updated yet. UPDATE 4: Added associated Manuscript information and DD and FLMD have been updated. To cite this code, please use the following BibTeX: @misc{nagamoto2025drought, author = {Emily Nagamoto and Fabio Ciulla and Mohammad Ombadi and Jared Willard and Rosemary Carroll and Charuleka Varadharajan}, title = {Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"}, year = {2025}, doi = {10.15485/2551894}, publisher = {ESS-DIVE Repository}, url = {https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2551894} }

54 ENVIRONMENTAL SCIENCES↗

Water-Film Cooling of an 80 deg Total-Angle Cone at a Mach Number of 2 for Airstream Total Temperatures up to 3,000 deg R

Film-cooling tests, with water as the coolant, were made on an 80 deg total-angle cone in a Mach number 2 free jet at sea-level pressure. The tests were made at free-stream total temperatures from 1,500 deg R to 3,000 deg R and at free-stream Reynolds numbers per foot from 8 x 10(exp 6) to 3 x 10(exp 6). The tests showed that the downstream end of the model became very hot if the coolant rate was too small to cover the complete model with a water film. This water film was fairly symmetrical when the model was at zero angle of attack but was very asymmetrical when the model was at an angle of attack of 5 deg. A comparison with results of a previous transpiration-cooling test showed that, with water as the coolant, transpiration cooling was at least 2.5 times as efficient as the film cooling of the present tests.

Carter, Howard S.↗

Finite analytic numerical solution of axisymmetric Navier-Stokes and energy equations

Convective heat transfer for steady state laminar flow in axisymmetric coordinates is considered. Numerical solutions for flow pattern and temperature distribution are obtained by the finite analytic numerical method applied to the Navier-Stokes equations expressed in terms of vorticity and stream function, and the energy equation. The finite analytic numerical method differs from other numerical methods in that it utilizes a local analytic solution in an element of the problem to construct the total numerical solution. Finite analytic solutions of vorticity, stream function, temperature and heat transfer coefficients for flow with Reynolds number of 5.0, 100.0, 1000.0, and 2000.0, and Prandtl number of 0.1, 1.0, and 10.0 with uniform grid sizes are reported for axisymmetric pipe with sudden expansion and contraction. The wall temperature is considered to be isothermal and differs from the inlet temperature. It is shown that the finite analytic solution is stable, converges rapidly, and simulates the convection of fluid flow accurately since the local analytic solution is capable of simulating automatically the influence of skewed convection through the element boundary on the interior nodal values thereby minimizing the false numerical diffusion.

Chen, C.-J.↗

Emission Spectroscopy and Radiometric Measurements in the NASA Ames IHF Arc Jet Facility

Plasma diagnostic measurement campaigns in the NASA Ames Interaction Heating Facility (IHF) have been conducted over the last several years with a view towards characterizing the flow in the arc jet facility by providing data necessary for modeling and simulation. Optical emission spectroscopy has been used in the plenum and in the free jet of the nozzle. Radiation incident over a probe surface has also been measured using radiometry. Plenum measurements have shown distinct radial profiles of temperature over a range of operating conditions. For cases where large amounts of cold air are added radially to the main arc-heated stream, the temperature profiles are higher by as much as 1500 K than the profiles assumed in flow simulations. Optical measurements perpendicular to the flow direction in the free jet showed significant contributions to the molecule emission through inverse pre-dissociation, thus allowing determination of atom number densities from molecular emission. This has been preliminarily demonstrated with the N2 1st Positive System. Despite the use of older rate coefficients, the resulting atom densities are reasonable and surprisingly close to flow predictions.

Winter, Michael W.↗

The Influence of Low Wall Temperature on Boundary-Layer Transition and Local Heat Transfer on 2-Inch-Diameter Hemispheres at a Mach Number of 4.95 and a Reynolds Number per Foot of 73.2 x 10(exp 6)

Measurements of the location of boundary-layer transition and the local heat transfer have been made on 2-inch-diameter hemispheres in the Langley gas dynamics laboratory at a Mach number of 4.95, a Reynolds number per foot of 73.2 x 10(exp 6), and a stagnation temperature of approximately 400 F. The transient-heating thin-skin calorimeter technique was used, and the initial values of the wall-to-stream stagnation- temperature ratios were 0.16 (cold-model tests) and 0.65 (hot-model test). During two of the four cold tests, the boundary-layer flow changed from turbulent to laminar over large regions of the hemisphere as the model heated. On the basis of a detailed consideration of the magnitude of roughness possibly present during these two cold tests, it appears that this destabilizing effect of low wall temperatures (cooling) was not caused by roughness as a dominant influence. This idea of a decrease in boundary-layer stability with cooling has been previously suggested. (See, for example, NASA Memorandum 10-8-58E.) For the laminar data obtained during the early part of the hot test, the correlation of the local-heating data with laminar theory was excellent.

Cooper, Morton↗

Analysis of heat transfer in a simulated wing-elevon cove in hypersonic flow

A simplified analytical model of leakage into a wing-elevon cove under high speed external flow conditions is presented. The model accounts for convection from the high temperature gas stream leaking into the cove, radiation exchanges between walls and with the environment, and axial conduction within the channel walls. Comparisons are made of predicted and measured wall temperatures of an experimental wing-elevon-cove model that was tested in a hypersonic wind tunnel. Analytically determined Nusselt numbers for laminar flow entrance conditions are compared with those calculated from experimentally measured gas temperatures, wall temperatures and wall heating rates. Although reasonable agreement appears to be indicated, testing times much larger than those of the present test program (5 seconds) would be desirable in evaluating the reliability and accuracy of the simplified model.

Keshock, E. G.↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Optimization of a Nafion Membrane-Based System for Removal of Chloride and Fluoride from Lunar Regolith-Derived Water

A long-term human presence in space will require self-sustaining systems capable of producing oxygen and potable water from extraterrestrial sources. Oxygen can be extracted from lunar regolith, and water contaminated with hydrochloric and hydrofluoric acids is produced as an intermediate in this process. We investigated the ability of Nafion proton exchange membranes to remove hydrochloric and hydrofluoric acids from water. The effect of membrane thickness, product stream flow rate, and acid solution temperature and concentration on water flux, acid rejection, and water and acid activity were studied. The conditions that maximized water transport and acid rejection while minimizing resource usage were determined by calculating a figure of merit. Water permeation is highest at high solution temperature and product stream flow rate across thin membranes, while chloride and fluoride permeation are lowest at low acid solution temperature and concentration across thin membranes. The figure of merit varies depending on the starting acid concentration; at low concentration, the figure of merit is highest across a thin membrane, while at high concentration, the figure of merit is highest at low solution temperature. In all cases, the figure of merit increases with increasing product stream flow rate.

Anthony, Stephen M.↗

Similitude requirements for hypersonic, rarefied, nonequilibrium flow

Similitude requirements for hypersonic, rarefied flow with nonequilibrium chemistry and vibration are presented. The full Navier-Stokes equations with catalytic or noncatalytic walls and with or without slip conditions are nondimensionalized. The heat transfer coefficient is written in terms of fourteen dimensionless parameters and reduced to four by making the binary scaling assumption. Duplication of blunt and sharp nose heat transfer requires the use of air over a geometrically similar model with the same free stream velocity, wall temperature and product of free stream density and characteristic length. Estimates of this heat transfer coefficient are also presented.

Hendricks, W. L.↗

Analysis of an effusive sampling device for analysis of boundary layer gases

The effect of suction, through an opening in a surface, upon a stream of flowing gas is determined. The quantity of interest is the maximum distance, Y, from the surface that the main stream is affected by the applied suction. The fraction of this distance Y of the boundary layer thickness sigma is determined as a function of tubing radius and length, gas pressure, temperature and stream velocity. The shape of the flow in the high velocity stream is assumed to be determined by means of a parameter which is an unknown function of the distance from the leading edge of the surface.

Brown, K. G.↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗