Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

dropletProbe Premium v1.201

Selects locations of interest for liquid microjunction surface sampling coupled to a subsequent analysis is done in a user friendly way. That information is then transferred to instrument control softwares. In addition, readout of a laser sensor allows for robust probe-to-surface distance measurement. Furthermore, pictures taken by the software from a camera provides feedback to judge on successful microjunction sampling.

Kertesz, Vilmos↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Combining Transmission Geometry Laser Ablation and a Non Contact Continuous Flow Surface Sampling Probe/Electrospray Emitter for Mass Spectrometry-Based Chemical Imaging

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection into a continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imaging. The flow probe/emitter device was placed in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collected was immediately aspirated into the probe and on to the electrospray emitter, ionized and detected with the mass spectrometer. Freehand drawn ink lines and letters and an inked fingerprint on microscope slides were analyzed. The circular laser ablation area was about 210 m in diameter and under the conditions used in these experiments the spatial resolution, as determined by the size of the surface features distinguished in the chemical images, was about 100 m.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and analysis of actively-cooled, edge-transport diagnostic for long-pulsed operation in WEST

Next step fusion devices that will operate in steady-state will require complex plasma-facing components (PFCs) that can survive the harsh environment over long timescales not common in current devices. This will require robust plasma facing surfaces that are integrated with active cooling systems. In a collaboration between CEA and ORNL, a plasma-interacting diagnostic is being designed for the W Environment in Steady-state Tokamak (WEST) in Cadarache, France which requires plasma-facing protection like those needed for steady-state PFCs. This integrated diagnostic studies edge transport and impurity migration within WEST, and is planned to include imbedded temperature Langmuir probe sensors, as well as removeable sample slots for ex-situ surface analysis of plasma-material interactions. The entire assembly is expected to move into the plasma edge for periods up to 1000 s having an energy removeable capability of ∼6 kW and seeing a peak heat flux of more than 7 MW/m2. The assembly compliments WEST high fluence campaigns that plan for multiple 1000 s pulses. Within these specifications, the assembly will require a refractory metal plasma facing surface and integral cooling in order to function within the limited space allotted for such diagnostics. Because of the limited space and linear actuator needs, additive manufacturing of the high heat flux working end of the assembly is being considered which could allow for precision cooling-channels and lighter weight designs. Conceptual design along with simulation and analysis results will be presented for this complex diagnostic with novel PFCs.

Lumsdaine, Arnold↗

SU-C-303-05: Photosensitizer Determination for PDT Using Interstitial and Surface Measurements of Fluorescence

Purpose: Photosensitizer concentration during photodynamic therapy (PDT) is an important parameter for accurate dosimetry. Fluorescence signal can be used as a measure of photosensitizer concentration. Two methods of data acquisition were compared to an ex vivo study both for in vivo and phantom models. Methods: Fluorescence signal of commonly used photosensitizer benzoporphyrin derivative monoacid ring A (BPD) was obtained in phantoms and mouse tumors using an excitation light of 405 nm. Interstitial fluorescence signal was obtained using a side-cut fiber inserted into the tumor tissue of interest. Using a previously developed multi-fiber probe, tumor surface fluorescence measurements were also collected. Signals were calibrated according to optical phantoms with known sensitizer fluorescence. Optical properties for each sample were determined and the influence of different absorption and scattering properties on the fluorescence signals was investigated. Using single value decomposition of the spectra, the sensitizer concentration was determined using the two different measurement geometries. An ex vivo analysis was also performed for tumor samples to determine the sensitizer concentration. Results: The two fluorescence signals obtained from the surface multi-fiber probe and the interstitial measurements were compared and were corresponding for both phantoms and mouse models. The values obtained were comparable to the ex vivo measurements as well. Despite the difference in geometry, the surface probe measurements can still be used as a metric for determining the presence of sensitizer in small volume tumors. Conclusion: The multi-fiber contact probe can be used as a tool to measure fluorescence at the surface of the treatment area for PDT and predict sensitizer concentration throughout the tumor. This is advantageous in that the measurement does not damage any tissue. Future work will include investigating the dependence of these results on intratumor sensitizer distribution.

60 APPLIED LIFE SCIENCES↗

Optical recognition of constructs using hyperspectral imaging and detection (ORCHID)

Abstract Challenges to deep sample imaging have necessitated the development of special techniques such as spatially offset optical spectroscopy to collect signals that have travelled through several layers of tissue. However, these techniques provide only spectral information in one dimension (i.e., depth). Here, we describe a general and practical method, referred to as Optical Recognition of Constructs Using Hyperspectral Imaging and Detection (ORCHID). The sensing strategy integrates (1) the spatial offset detection concept by computationally binning 2D optical data associated with digital offsets based on selected radial pixel distances from the excitation source; (2) hyperspectral imaging using tunable filter; and (3) digital image binding and collation. ORCHID is a versatile modality that is designed to collect optical signals deep inside samples across three spatial (X, Y, Z) as well as spectral dimensions. The ORCHID method is applicable to various optical techniques that exhibit narrow-band structures, from Raman scattering to quantum dot luminescence. Samples containing surface-enhanced Raman scattering (SERS)-active gold nanostar probes and quantum dots embedded in gel were used to show a proof of principle for the ORCHID concept. The resulting hyperspectral data cube is shown to spatially locate target emitting nanoparticle volumes and provide spectral information for in-depth 3D imaging.

47 OTHER INSTRUMENTATION↗

Electric force microscopy of semiconductors: Theory of cantilever frequency fluctuations and noncontact friction

An electric force microscope employs a charged atomic force microscope probe in vacuum to measure fluctuating electric forces above the sample surface generated by dynamics of molecules and charge carriers. We present a theoretical description of two observables in electric force microscopy of a semiconductor: the spectral density of cantilever frequency fluctuations (jitter), which are associated with low-frequency dynamics in the sample, and the coefficient of noncontact friction, induced by higher-frequency motions. The treatment is classical-mechanical, based on linear response theory and classical electrodynamics of diffusing charges in a dielectric continuum. Calculations of frequency jitter explain the absence of contributions from carrier dynamics to previous measurements of an organic field effect transistor. Calculations of noncontact friction predict decreasing friction with increasing carrier density through the suppression of carrier density fluctuations by intercarrier Coulomb interactions. The predicted carrier density dependence of the friction coefficient is consistent with measurements of the dopant density dependence of noncontact friction over Si. Our calculations predict that in contrast to the measurement of cantilever frequency jitter, a noncontact friction measurement over an organic semiconductor could show appreciable contributions from charge carriers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Studies of minute quantities of natural abundance molecules using 2D heteronuclear correlation spectroscopy under 100kHz MAS

Two-dimensional 1 H{ 13 C} heteronuclear correlation solid-state NMR spectra of naturally abundant solid materials are presented, acquired using the 0.75-mm magic angle spinning (MAS) probe at spinning rates up to 100 kHz. In spite of the miniscule sample volume (290 nL), high-quality HSQC-type spectra of bulk samples as well as surface-bound molecules can be obtained within hours of experimental time. The experiments are compared with those carried out at 40 kHz MAS using a 1.6-mm probe, which offered higher overall sensitivity due to a larger rotor volume. The benefits of ultrafast MAS in such experiments include superior resolution in 1 H dimension without resorting to 1 H– 1 H homonuclear RF decoupling, easy optimization, and applicability to mass-limited samples. As a result, the HMQC spectra of surface-bound species can be also acquired under 100 kHz MAS, although the dephasing of transverse magnetization has significant effect on the efficiency transfer under MAS alone.

36 MATERIALS SCIENCE↗

Three-dimensional indium distribution in electron-beam irradiated multiple quantum wells of blue-emitting InGaN/GaN devices

The compositional distribution of In atoms in InGaN/GaN multiple quantum wells is considered as one of the candidates for carrier localization center, which enhances the efficiency of the light-emitting diodes. However, two challenging issues exist in this research area. First, an inhomogeneous In distribution is initially formed by spinodal decomposition during device fabrication as revealed by transmission electron microscopy. Second, electron-beam irradiation during microscopy causes the compositional inhomogeneity of In to appear as a damage contrast. Here, a systematic approach was proposed in this study: Electron-beam with current density ranging from 0 to 20.9 A/cm{sup 2} was initially exposed to the surface regions during microscopy. Then, the electron-beam irradiated regions at the tip surface were further removed, and finally, atom probe tomography was performed to run the samples without beam-induced damage and to evaluate the existence of local inhomegenity of In atoms. We proved that after eliminating the electron-beam induced damage regions, no evidence of In clustering was observed in the blue-emitting InGaN/GaN devices. In addition, it is concluded that the electron-beam induced localization of In atoms is a surface-related phenomenon, and hence spinodal decomposition, which is typically responsible for such In clustering, is negligible for biaxially strained blue-emitting InGaN/GaN devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of fuel type and deposition surface temperature on the growth and structure of an ash deposit collected during co-firing of coal with sewage sludge and sawdust

Blends of a South African bituminous 'Middleburg' coal, a municipal sewage sludge, and a sawdust have been fired in the slagging reactor to examine the effect of the added fuel on the slagging propensity of the mixtures. Uncooled ceramic probes and air-cooled metal probes were used to examine the influence of the deposition surface temperature on the growth and structureof the deposits. The initial stages of slagging were in a high-temperature range of 1100-1300{sup o}C and a low-temperature range of 550-700{sup o}C. Laboratory ash, ash sampled on the deposition probes, and ash collected in the cyclone have been analyzed using the X-ray fluorescence technique. The electron probe microanalysis (EPMA) of the embedded resin deposit probes have been performed to determine the thickness, structure, porosity, and chemical composition in different layers of the deposit. Distinct differences in structures of the deposits collected using the uncooled ceramic probes and air-cooled steal probes were observed. Glassy, easily molten deposits collected on uncooled ceramic deposition probes are characteristic for co-firing of municipal sewage sludge with coal. Porous, sintered, but easily removable deposits of the same fuel blend have been collected on the air-cooled metal deposition probes. The addition of sawdust does not negatively influence the deposition behavior. Loose, easy removable deposits have been sampled on air-cooled metal deposition probes during co-firing of coal-sawdust blends. The mass of the deposit sampled at lower deposition surface temperatures (550-700{sup o}C) was always larger than the mass sampled at higher surface temperatures (1100-1300{sup o}C). 12 refs., 6 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Laser interferometric method for determining the carrier diffusion length in semiconductors

A new laser interferometric method for measuring the carrier diffusion length in semiconductors is proposed. The method is based on the interference–absorption interaction of two laser radiations in a semiconductor. Injected radiation generates additional carriers in a semiconductor, which causes a change in the material’s optical constants and modulation of the probing radiation passed through the sample. When changing the distance between carrier generation and probing points, a decrease in the carrier concentration, which depends on the diffusion length, is recorded. The diffusion length is determined by comparing the experimental and theoretical dependences of the probe signal on the divergence of the injector and probe beams. The method is successfully tested on semiconductor samples with different thicknesses and surface states and can be used in scientific research and the electronics industry.

36 MATERIALS SCIENCE↗

Surface studies of plasma processed Nb samples

Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO 2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

36 MATERIALS SCIENCE↗

Observation of Strong Resonant Behavior in the Inverse Photoelectron Spectroscopy of Ce Oxide

X-ray Emission Spectroscopy (XES) and Resonant Inverse Photoelectron Spectroscopy (RIPES) have been used to investigate the photon emission associated with the Ce3d5/2 and Ce3d3/2 thresholds. Strong resonant behavior has been observed in the RIPES of Ce Oxide near the 5/2 and 3/2 edges. Inverse Photoelectron Spectroscopy (IPES) and its high energy variant, Bremstrahlung Isochromat Spectroscopy (BIS), are powerful techniques that permit a direct interrogation of the low-lying unoccupied electronic structure of a variety of materials. Despite being handicapped by counting rates that are approximately four orders of magnitude less that the corresponding electron spectroscopies (Photoelectron Spectroscopy, PES, and X-ray Photoelectron Spectroscopy, XPS) both IPES and BIS have a long history of important contributions. Over time, an additional variant of this technique has appeared, where the kinetic energy (KE) of the incoming electron and photon energy (hv) of the emitted electron are roughly the same magnitude as the binding energy of a core level of the material in question. Under these circumstances and in analogy to Resonant Photoelectron Spectroscopy, a cross section resonance can occur, giving rise to Resonant Inverse Photoelectron Spectroscopy or RIPES. Here, we report the observation of RIPES in an f electron system, specifically the at the 3d{sub 5/2} and 3d{sub 3/2} thresholds of Ce Oxide. The resonant behavior of the Ce4f structure at the 3d thresholds has been addressed before, including studies of the utilization of the technique as a probe of electron correlation in a variety of Ce compounds. Interestingly, the first RIPES work on rare earths dates back to 1974, although under conditions which left the state of the surface and near surface regions undefined. Although they did not use the more modern terminology of 'RIPES,' it is clear that RIPES was actually first performed in 1974 by Liefeld, Burr and Chamberlain on both La and Ce based materials. In these experiments, the La and Ce metallic samples were attached to the anode of an x-ray tube and the x-ray emission characteristics were measured using a two crystal monochromator. The pressure in the x-ray tube was quoted as being below 2 x 10{sup -8} Torr. They did indeed observed resonant behavior at the M{alpha} (3d{sub 5/2}) and M{beta} (3d{sub 3/2}) thresholds. In fact, our results here will confirm the measurements made upon the Ce based sample used in by Liefeld et al. However, the state of the Ce sample surface and near surface regions are quite undefined in the study in Ref 9. For example, the authors suggest that they are probing Ce metal, since they cannot see any evidence of an OK{alpha} (1s) XES line. However, they do report the observation of FK{alpha} (1s) line, possibly due to the utilization of cerium fluoride in the sample preparation. Later, they tried to address these issues in a new ultrahigh vacuum system. Based upon our results, it is clear that their original sample surface was oxidized, using the word here in its more general context as in having lost electrons to the oxidizing agent, although whether the structure is an oxide or fluoride remains unclear. In any case, the primacy of Liefeld and coworkers in these measurements should be noted. Cerium and cerium oxide have been studied with a variety of spectroscopic techniques under UHV conditions. This includes Bremstrahlung Isochromat Spectroscopy or BIS, Photoelectron Spectroscopy, X-ray Absorption Spectroscopy, Electron Energy Loss Spectroscopy and Resonant XES, to name just a few. We will compare our results to those of other spectroscopies.

36 MATERIALS SCIENCE↗

In situ X-ray and IR probes relevant to Earth science at the Advanced Light Source at Lawrence Berkeley Laboratory

Access to synchrotron X-ray facilities has become an important aspect for many disciplines in experimental Earth science. This is especially important for studies that rely on probing samples in situ under natural conditions different from the ones found at the surface of the Earth. The non-ambient condition Earth science program at the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory, offers a variety of tools utilizing the infra-red and hard X-ray spectrum that allow Earth scientists to probe Earth and environmental materials at variable conditions of pressure, stress, temperature, atmospheric composition, and humidity. These facilities are important tools for the user community in that they offer not only considerable capacity (non-ambient condition diffraction) but also complementary (IR spectroscopy, microtomography), and in some cases unique (Laue microdiffraction) instruments. The availability of the ALS’ in situ probes to the Earth science community grows especially critical during the ongoing dark time of the Advanced Photon Source in Chicago, which massively reduces available in situ synchrotron user time in North America.

58 GEOSCIENCES↗

Three-dimensional broadband nonlinear phased array imaging

System include an ultrasonic transducer configured to couple to a nondestructive testing (NDT) sample and configured to produce and direct an ultrasonic probe wave at a selected frequency into a subsurface region of the NDT sample, a 3D laser scanning vibrometer configured to direct a detection beam in a scan area on a surface of the NDT sample and to receive a return beam from the scan area, and to detect, based on the return beam, a 3D motion of the surface across a wideband frequency range, and a processor, and a memory configured with instructions that, when executed by the processor, cause the processor to produce sub-surface image data of the NDT sample at multiple harmonics of the selected frequency in the wideband frequency range based on the detected 3D surface motion, wherein the sub-surface image data describes a nonlinear defect response produced in the NDT sample by interaction of the ultrasonic probe wave with the subsurface region.

Remillieux, Marcel↗

Stabilizing the Meniscus for Operando Characterization of Platinum During the Electrolyte-Consuming Alkaline Oxygen Evolution Reaction

Achieving a molecular-level understanding of interfacial (photo)electrochemical processes is essential in order to tailor novel and highly-performing catalytic systems. The corresponding recent development of in situ and operando tools has posed new challenges on experimental architectures. In this study, we use ambient pressure X-ray photoelectron spectroscopy (AP-XPS) to probe the solid/liquid electrified interface of a polycrystalline Pt sample in contact with an alkaline electrolyte during hydrogen and oxygen evolution reactions. Using the “dip-and-pull” technique to probe the interface through a thin liquid layer generated on the sample surface, we observe that the electrolyte meniscus becomes unstable under sustained driving of an electrolyte-consuming reaction (such as water oxidation). The addition of an electrochemically inert supporting electrolyte mitigates this issue, maintaining a stable meniscus layer for prolonged reaction times. In contrast, for processes in which the electrolyte is replenished in the reaction pathway (i.e. water reduction in alkaline conditions), we find that the solid/liquid interface remains stable without addition of a secondary supporting electrolyte. The approach described in this work allows the extension of operando AP-XPS capabilities using the “dip-and-pull” method to a broader class of reactions consuming ionic species during complex interfacial faradaic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deuterium Retention in NSTX with Lithium Conditioning

High (approximate to 90%) deuterium retention was observed in NSTX gas balance measurements both with- and without lithiumization of the carbon plasma-facing components. The gas retained in ohmic discharges was measured by comparing the vessel pressure rise after a discharge to that of a gas-only pulse with the pumping valves closed. For neutral beam heated discharges the gas input and gas pumped by the NB cryopanels were tracked. The discharges were followed by outgassing of deuterium that reduced the retention. The relationship between retention and surface chemistry was explored with a new plasma-material interface probe connected to an in vacuo surface science station that exposed four material samples to the plasma. XPS and TDS analysis demonstrated that binding of D atoms in graphite is fundamentally changed by lithium - in particular atoms are weakly bonded in regions near lithium atoms bound to either oxygen or the carbon matrix. This is in contrast to the strong ionic bonding that occurs between D and pure Li. (C) 2010 Elsevier B.V. All rights reserved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-Surface Imaging of the Multicomponent Gas Phase above a Silver Catalyst during Partial Oxidation of Methanol

Fundamental chemistry in heterogeneous catalysis is increasingly explored using operando techniques in order to address the pressure gap between ultrahigh vacuum studies and practical operating pressures. Because most operando experiments focus on the surface and surface-bound species, there is a knowledge gap of the near-surface gas phase and the fundamental information the properties of this region convey about catalytic mechanisms. In this work, we demonstrate in situ visualization and measurement of gas-phase species and temperature distributions in operando catalysis experiments using complementary near-surface optical and mass spectrometry techniques. The partial oxidation of methanol over a silver catalyst demonstrates the value of these diagnostic techniques at 600 Torr (800 mbar) pressure and temperatures from 150 to 410 °C. Planar laser-induced fluorescence provides two-dimensional images of the formaldehyde product distribution that show the development of the boundary layer above the catalyst under different flow conditions. Raman scattering imaging provides measurements of a wide range of major species, such as methanol, oxygen, nitrogen, formaldehyde, and water vapor. Near-surface molecular beam mass spectrometry enables simultaneous detection of all species using a gas sampling probe. Detection of gas-phase free radicals, such as CH 3 and CH 3 O, and of minor products, such as acetaldehyde, dimethyl ether, and methyl formate, provides insights into catalytic mechanisms of the partial oxidation of methanol. The combination of these techniques provides a detailed picture of the coupling between the gas phase and surface in heterogeneous catalysis and enables parametric studies under different operating conditions, which will enhance our ability to constrain microkinetic models of heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗