Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Minor surgery in microgravity

The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.

Billica, Roger↗

Telemedicine, virtual reality, and surgery

Two types of synthetic experience are covered: virtual reality (VR) and surgery, and telemedicine. The topics are presented in viewgraph form and include the following: geometric models; physiological sensors; surgical applications; virtual cadaver; VR surgical simulation; telesurgery; VR Surgical Trainer; abdominal surgery pilot study; advanced abdominal simulator; examples of telemedicine; and telemedicine spacebridge.

Mccormack, Percival D.↗

Simulation of arthroscopic surgery using MRI data

With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

Heller, Geoffrey↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Assessing quality in cardiac surgery: why this is necessary in the twenty-first century

The cost and high-profile nature of coronary surgery means that this is an area of close public scrutiny. As much pioneering work in data collection and risk analyses has been carried out by cardiac surgeons, substantial information exists and the correct interpretation of that data is identified as an important issue. This paper considers the background and history of risk-adjustment in cardiac surgery, the uses of quality data, examines the observed/expected mortality ratio and looks at issues such as cost and reactions to outliers. The conclusion of the study is that the continuation of accurate data collection by the whole operative team and a strong commitment to constantly improving quality is crucial to its meaningful application.

Review↗

A national center for biocomputation: in search of a patient-specific interactive virtual surgery workbench

This report describes the three-dimensional imaging and virtual environment technologies developed in NASA's Biocomputation Center for scientific purposes that have now led to applications in the field of medicine. A major goal is to develop a virtual environment surgery workbench for planning complex craniofacial and breast reconstructive surgery, and for training surgeons.

NASA Discipline Neuroscience↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Cataract Surgery Tool

The NASA-McGannon cataract surgery tool is a tiny cutter-pump which liquefies and pumps the cataract lens material from the eye. Inserted through a small incision in the cornea, the tool can be used on the hardest cataract lens. The cutter is driven by a turbine which operates at about 200,000 revolutions per minute. Incorporated in the mechanism are two passages for saline solutions, one to maintain constant pressure within the eye, the other for removal of the fragmented lens material and fluids. Three years of effort have produced a design, now being clinically evaluated, with excellent potential for improved cataract surgery. The use of this tool is expected to reduce the patient's hospital stay and recovery period significantly.

Source record↗

Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery

The term Multi-Angle and Rear Viewing Endoscopic tooL (MARVEL) denotes an auxiliary endoscope, now undergoing development, that a surgeon would use in conjunction with a conventional endoscope to obtain additional perspective. The role of the MARVEL in endoscopic brain surgery would be similar to the role of a mouth mirror in dentistry. Such a tool is potentially useful for in-situ planetary geology applications for the close-up imaging of unexposed rock surfaces in cracks or those not in the direct line of sight. A conventional endoscope provides mostly a frontal view that is, a view along its longitudinal axis and, hence, along a straight line extending from an opening through which it is inserted. The MARVEL could be inserted through the same opening as that of the conventional endoscope, but could be adjusted to provide a view from almost any desired angle. The MARVEL camera image would be displayed, on the same monitor as that of the conventional endoscopic image, as an inset within the conventional endoscopic image. For example, while viewing a tumor from the front in the conventional endoscopic image, the surgeon could simultaneously view the tumor from the side or the rear in the MARVEL image, and could thereby gain additional visual cues that would aid in precise three-dimensional positioning of surgical tools to excise the tumor. Indeed, a side or rear view through the MARVEL could be essential in a case in which the object of surgical interest was not visible from the front. The conceptual design of the MARVEL exploits the surgeon s familiarity with endoscopic surgical tools. The MARVEL would include a miniature electronic camera and miniature radio transmitter mounted on the tip of a surgical tool derived from an endo-scissor (see figure). The inclusion of the radio transmitter would eliminate the need for wires, which could interfere with manipulation of this and other surgical tools. The handgrip of the tool would be connected to a linkage similar to that of an endo-scissor, but the linkage would be configured to enable adjustment of the camera angle instead of actuation of a scissor blade. It is envisioned that thicknesses of the tool shaft and the camera would be less than 4 mm, so that the camera-tipped tool could be swiftly inserted and withdrawn through a dime-size opening. Electronic cameras having dimensions of the order of millimeters are already commercially available, but their designs are not optimized for use in endoscopic brain surgery. The variety of potential endoscopic, thoracoscopic, and laparoscopic applications can be expected to increase as further development of electronic cameras yields further miniaturization and improvements in imaging performance.

Bae, Youngsam↗

Real-Time Teleguidance of a Non-Surgeon Crew Medical Officer Performing Orthopedic Surgery at the Amundsen-Scott South Pole Station During Winter-Over

The Amundsen-Scott South Pole Research station located at the geographic South Pole, is the most isolated, permanently inhabited human outpost on Earth. Medical care is provided to station personnel by a non-surgeon crew medical officer (CMO). During the winter-over period from February to October, the station is isolated, with no incoming or outgoing flights due to severe weather conditions. In late June, four months after the station had closed for the austral winter, a 31 year old meteorologist suffered a complete rupture of his patellar tendon while sliding done an embankment. An evacuation was deemed to be too risky to aircrews due to the extreme cold and darkness. A panel of physicians from Massachusetts General Hospital, Johns Hopkins University and the University of Texas Medical Branch were able to assess the patient remotely via telemedicine and agreed that surgery was the only means to restore mobility and prevent long term disability. The lack of a surgical facility and a trained surgical team were overcome by conversion of the clinic treatment area, and intensive preparation of medical laypersons as surgical assistants. The non-surgeon CMO and CMO assistant at South Pole, were guided through the administration of spinal anesthetic, and the two-hour operative repair by medical consultants at Massachusetts General Hospital. Real-time video of the operative field, directions from the remote consultants and audio communication were provided by videoconferencing equipment, operative cameras, and high bandwidth satellite communications. In real-time, opening incision/exposure, tendon relocation, hemostatsis, and operative closure by the CMO was closely monitored and guided and by the remote consultants. The patient s subsequent physical rehabilitation over the ensuing months of isolation was also monitored remotely via telemedicine. This was the first time in South Pole s history that remote teleguidance had been used for surgery and represents a model for real-time guidance of CMO s working at remote duty stations.

Otto, Christian↗

A Rare Case of Left Ventricular Intramural Hemangioma Diagnosed Using 1.5-T Cardiac MRI with Histopathological Correlation and Successfully Treated by Surgery

Hemangiomas are vascular tumors composed of blood vessels, frequently localized in the skin and subcutaneous muscles; their localization in the heart is exceptional. The most common localizations are the lateral walls of the left ventricle, the anterior wall, and the septum. Mostly, these tumors grow intracavitarily, rarely intramurally. We describe a singular case of left ventricular intramural hemangioma, detected and diagnosed using newer magnetic resonance imaging (MRI) modalities, confirmed by histopathological results, and treated successfully by surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Results of Ultrasonography-Guided Percutaneous Radiofrequency Ablation in Hyperparathyroid Patients in Whom Surgery Is Not Feasible

BackgroundThe aim of the study was to evaluate the results of ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) in hyperparathyroid patients who refused surgery or had high surgical risks.Patients and MethodsFive patients with hyperparathyroidism (HPT) underwent US-guided RFA for a single hyperfunctioning parathyroid lesion. Post-ablation serum calcium and parathormone (PTH) assays were performed. All patients underwent imaging studies 6 months after the ablation to visualize the post-ablation change in the size of the treated parathyroid lesions.ResultsAll patients were normocalcemic on the post-ablation 1st day and 6th month. The post-ablation PTH levels were normal in three patients but remained elevated in two patients. The size of the parathyroid lesion was ≥30 mm in the two patients with elevated PTH, whereas the lesion was smaller than 30 mm in those with normal post-ablation PTH values.ConclusionAlthough this is a limited case series, it demonstrates the potential feasibility of RFA for HPT. Benefits were achieved particularly in patients with small parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Postoperative Bleeding Following Abdominal Surgery

PurposeWe aimed to estimate the usefulness of transcatheter arterial embolization (TAE) in patients with postoperative abdominal hemorrhage and to evaluate the effects of pancreatic fistula on clinical outcomes and angiographic findings.Materials and MethodsWe enrolled 22 patients (20 males and 2 females; mean age 63 years; range 25–86 years), who underwent transarterial angiography for postoperative hemorrhage after abdominal surgery. This group corresponded to 28 procedures. Technical and clinical success rates were calculated, and clinical findings and outcomes were compared between patients with and without a pancreatic fistula.ResultsPre-interventional CT was performed in all patients before first angiography, and the location of the bleeding was identified in all but one patient. Active arterial bleeding, identified by extravasation of contrast agent (n = 12), pseudoaneurysm formation (n = 12), and arterial wall irregularity (n = 2) were detected in 28 angiographic procedures, and embolization was performed in 26 instances. Various embolization techniques such as isolation, packing, embolization, and stentgraft implantation were performed. The technical and clinical success rates were 96% (25/26 procedures) and 82% (18/22 patients), respectively. In hemodynamically unstable patients (shock index: heart rate/systolic blood pressure > 1), a 92% (12/13 cases) technical success rate was achieved. There were no significant differences in any evaluated parameters between patients with and without pancreatic fistula.ConclusionTAE is a safe and effective for treating postoperative hemorrhage even in patients with hemodynamic instability and pancreatic fistula. Additionally, pre-interventional CT is useful for effective, consecutive interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Dose-Volume Relation Model for Gamma Knife Surgery of Non-Skull Base Intracranial Meningiomas

Purpose: To provide a dose-volume relationship for gamma knife surgery (GKS) of non-skull base intracranial meningiomas. Methods and Materials: The radiologic outcomes of GKS of 82 imaging-defined benign meningiomas located at non-skull base areas were analyzed. A total of 80 patients were included and all underwent treatment with GKS as the first and the only treatment modality. The mean patient age was 55.0 years (range, 26-78) and the mean tumor volume was 5.6 cm{sup 3} (range, 0.5-16.8). On average, 14.6 Gy (range, 10-20) was applied to the 50% isodose surface. The binary logistic regression method was applied to find prognostic factors of signal change (SC) on T{sub 2}-weighted magnetic resonance imaging after GKS. Results: The actuarial tumor control rate was 91.6% at 5 years. A total of 29 lesions (35.4%) showed newly developed or aggravated SCs. The volume irradiated {>=}14 Gy was the only statistically significant (p < .01) prognostic factor of SC. A dose-volume relation model obtained from the cases without SC estimated a 12.2% SC probability. Conclusion: This model can be used in GKS to treat small- to medium-size (<9.2 cm{sup 3}) non-skull base meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated and Accelerated Radiotherapy With Subcutaneous Amifostine Cytoprotection as Short Adjuvant Regimen After Breast-Conserving Surgery: Interim Report

Purpose: Short radiotherapy schedules might be more convenient for patients and overloaded radiotherapy departments, provided late toxicity is not increased. We evaluated the efficacy and toxicity of a hypofractionated and highly accelerated radiotherapy regimen supported with cytoprotection provided by amifostine in breast cancer patients treated with breast-conserving surgery. Methods and Materials: A total of 92 patients received 12 consecutive fractions of radiotherapy (3.5 Gy/fraction for 10 fractions) to the breast and/or axillary/supraclavicular area and 4 Gy/fraction for 2 fractions to the tumor bed). Amifostine at a dose of 1,000 mg/d was administered subcutaneously. The follow-up of patients was 30-60 months (median, 39). Results: Using a dose individualization algorithm, 77.1% of patients received 1,000 mg and 16.3% received 750 mg of amifostine daily. Of the 92 patients, 13% interrupted amifostine because of fever/rash symptoms. Acute Grade 2 breast toxicity developed in 6.5% of patients receiving 1,000 mg of amifostine compared with 46.6% of the rest of the patients (p < .0001). The incidence of Grade 2 late sequelae was less frequent in the high amifostine dose group (3.2% vs. 6.6%; p = NS). Grade 1 lung fibrosis was infrequent (3.3%). The in-field relapse rate was 3.3%, and an additional 2.2% of patients developed a relapse in the nonirradiated supraclavicular area. c-erbB-2 overexpression was linked to local control failure (p = .01). Distant metastasis appeared in 13% of patients, and this was marginally related to more advanced T/N stage (p = .06). Conclusion: Within a minimal follow-up of 2.5 years after therapy, hypofractionated and accelerated radiotherapy with subcutaneous amifostine cytoprotection has proved a well-tolerated and effective regimen. Longer follow-up is required to assess the long-term late sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neoadjuvant Treatment Does Not Influence Perioperative Outcome in Rectal Cancer Surgery

Purpose: To identify the risk factors for perioperative morbidity in patients undergoing resection of primary rectal cancer, with a specific focus on the effect of neoadjuvant therapy. Methods and Materials: This exploratory analysis of prospectively collected data included all patients who underwent anterior resection/low anterior resection or abdominoperineal resection for primary rectal cancer between October 2001 and October 2006. The study endpoints were perioperative surgical and medical morbidity. Univariate and multivariate analyses of potential risk factors were performed. Results: A total of 485 patients were included in this study; 425 patients (88%) underwent a sphincter-saving anterior resection/low anterior resection, 47 (10%) abdominoperineal resection, and 13 (2%) multivisceral resection. Neoadjuvant chemoradiotherapy was performed in 100 patients (21%), and 168 (35%) underwent neoadjuvant short-term radiotherapy (5 x 5 Gy). Patient age and operative time were independently associated with perioperative morbidity, and operative time, body mass index >27 kg/m{sup 2} (overweight), and resection type were associated with surgical morbidity. Age and a history of smoking were confirmed as independent prognostic risk factors for medical complications. Neoadjuvant therapy was not associated with a worse outcome. Conclusion: The results of this prospective study have identified several risk factors associated with an adverse perioperative outcome after rectal cancer surgery. In addition, neoadjuvant therapy was not associated with increased perioperative complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Dual-Time Combined 18-Fluorideoxyglucose Positron Emission Tomography and Computed Tomography in the Staging and Restaging Workup of Locally Advanced Rectal Cancer, Treated With Preoperative Chemoradiation Therapy and Radical Surgery

Purpose: In patients with locally advanced rectal cancer (LARC) staging and, after preoperative chemo-radiation therapy (CRT), restaging workup could be useful to tailor therapeutic approaches. Fluorine-18-fluorodeoxyglucose positron emission tomography ([{sup 18}F]FDG-PET) is a promising tool for monitoring the effect of antitumor therapy. This study was aimed to evaluate the possible role of dual time sequential FDG-PET scans in the staging and restaging workup of LARC. Methods and Materials: Eighty-seven consecutive patients with LARC were enrolled. CRT consisted of external-beam intensified radiotherapy (concurrent boost), with concomitant chemotherapy PVI 5-FU (300mg/m{sup 2}/day) followed 8-10 weeks later by surgery. All patients underwent [{sup 18}F]FDG-PET/CT before and 5-6 weeks later after the completion of CRT. Measurements of FDG uptake (SUV{sub max}), and percentage of SUV{sub max} difference (Response Index = RI) between pre- and post-CRT [{sup 18}F]FDG-PET scans were evaluated. Results: Six of 87 patients were excluded due to protocol deviation. Following CRT, 40/81 patients (49%) were classified as responders according to Mandard's criteria (TRG1-2). The mean pre-CRT SUV{sub max} was significantly higher than post-CRT (15.8, vs 5.9; p < 0.001). The mean RI was significantly higher in responders than in nonresponder patients (71.3% vs 38%; p = 0.0038). Using a RI cut-off of 65% for defining response to therapy, the following parameters have been obtained: 84.5% sensitivity, 80% specificity, 81.4% positive predictive value, 84.2% negative predictive value, and 81% overall accuracy. Conclusion: These results suggest the potential role of [{sup 18}F]FDG-PET in the restaging workup after preoperative CRT in LARC. RI seems the best predictor to identify CRT response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bone Fractures Following External Beam Radiotherapy and Limb-Preservation Surgery for Lower Extremity Soft Tissue Sarcoma: Relationship to Irradiated Bone Length, Volume, Tumor Location and Dose

Purpose: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Methods and Materials: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. Results: For fracture patients, mean dose to bone was 45 +- 8 Gy (mean dose at fracture site 59 +- 7 Gy), mean FS was 37 +- 8 cm, maximum dose was 64 +- 7 Gy, and V40 was 76 +- 17%, compared with 37 +- 11 Gy, 32 +- 9 cm, 59 +- 8 Gy, and 64 +- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. Conclusions: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗