Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchrophasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Discovery of Signatures, Anomalies, and Precursors in Synchrophasor Data with Matrix Profile and Deep Recurrent Neural Networks (Final Project Report)

The widespread deployment of phasor measurement unit (PMU) across the U.S. together with the burgeoning machine learning technology made it possible to develop data-driven PMU data analytics to improve grid security and reliability in a more insightful and effective manner. Although PMU applications have been explored for over a decade, the representative PMU usage is limited to the bulk power system monitoring mainly due to the data integrity issues associated with PMUs (typically missing, fragmented, and wrongly amplified data). To forge a breakthrough on this stalemate and embrace PMUs for power system control and protection as well, we applied various advanced machine learning and big data analysis technology to the power system event detection and classification as the first step toward the power system control and protection pertaining to grid security enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor-Based Zonal Current Differential Protection for Secondary Low Voltage Networks

This report describes an approach to utilizing phasor measurement unit (PMU) data from multiple Intelligent Electronics Devices (IEDs) in a low-voltage network to produce a differential scheme for protecting the medium-voltage feeder and low-voltage network transformers. The proposed protection scheme is designed and prototyped on a real-time automation controller. Its performance is evaluated using real-time controller hardware-in-the-loop simulation. Lab testing results indicate that the proposed protection scheme allows significant distributed energy resources (DER) backfeed and enables selective and fast protection of medium voltage feeders.

42 ENGINEERING↗

A Persistence Meter for Nimble Alarming Using Ambient Synchrophasor Data

Persistent oscillations in the power grid are often indicative of fragility, and may be harbingers of systemic or cascading failures. Modernization of the grid, including increased penetration of intermittent renewables and integration of new power electronics, is making the oscillatory swing dynamics of the network both more complex and variable. In this project researchers from the University of Wisconsin-Madison (Bernard Lesieutre, lead), Washington State University (Sandip Roy, lead), and the Electric Power Group (Neeraj Nayak, lead) have developed technologies that monitor persistent oscillations in the grid and provide operators with alarms and analytics when concerning oscillations are detected. Some of the algorithms have already been implemented in EPG’s PGDA software and integrated into their RTDMS system for use in control rooms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Phasor Communication Protocols

In this paper, we compare three approaches used for continuous transfer of real-time synchrophasor data: IEEE C37.118.2-2011, IEC TR 61850-90-5 and a new protocol being developed under the Department of Energy (DOE) project DOE-OE-859 called the Streaming Telemetry Transport Protocol (STTP). STTP is currently being advanced as a potential third standard protocol via the IEEE Power Engineering Society STTP P10 Work Group (P2664). Each of these three synchrophasor protocols is described in detail in this paper along with the basis for their operating characteristics using Internet Protocol (IP) transport. The dominant protocol for the exchange of synchrophasor data is IEEE C37.118, both in the U.S. and internationally. The most recent IEEE C37.118 standard is broken into two parts where IEEE C37.118.1-2011 (Part 1) defines the normative synchrophasor measurement requirements and IEEE C37.118.2-2011 (Part 2) defines the protocol’s data transmission format. Both the IEC TR 61850-90-5 and the emergent STTP specifications only address synchrophasor data transmission; therefore, this paper focuses on comparing the data transmission protocol elements of these standards. The primary dimensions of comparison of these three protocols explored in this paper are: structure, efficiency, susceptibility to data loss, scalability, security, and other operability functionality. Additionally, though not specifically relevant to synchrophasor data telemetry, the three protocols are evaluated with respect to flexibility for transporting non-synchrophasor precise-time data streams.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pre-Commercial Demonstration of Direct Non-Iterative State Estimator (DNSE+)

The objective of this DOE co-funded project is to demonstrate functionality and performance of a production-grade Direct Non-iterative State Estimator (DNSE) through its integration with NYPA’s Energy Management System (EMS) and an enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). A production-grade DNSE aims to overcome a major obstacle to the operational use of synchrophasor data in Synchro-Phasor Management Systems (SPMS) by providing SPMS applications with a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, the DNSE uses synchrophasor measurements and Supervisory Control and Data Acquisition (SCADA) measurements, together with the complete power system model, to simultaneously obtain the complete state of the entire utility’s operating model at rates that are close to the synchrophasor data rates. The full system coverage property is what distinguishes the DNSE from the linear synchrophasor SEs (which cover only parts of the operating model that are visible through synchrophasor measurements), and DNSE differs from traditional EMS SE in that the solution is obtained without iterations, without initial values (hence the “direct” in the name), and at a much higher execution rate. This presentation provides an overview of the project objectives, a brief description of the main tasks including the development work to productize and optimize DNSE from its current MATLAB code base, RTDMS enhancement for interfacing with the DNSE, factory acceptance testing, field installation, testing and demonstration, as well as the current status of the project execution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Clarke Transformation-Based DFT Phasor and Frequency Algorithm for Wide Frequency Range

Despite its wide applications in power grid monitoring, the classic discrete Fourier transform (DFT)-based synchrophasor estimation algorithms suffer from significant errors when the power system operates under off-nominal frequency conditions. This phenomenon is caused by spectral leakage of DFT and becomes even more severe for single-phase synchrophasor estimation. To address this issue, a theory to eliminate the spectral leakage-caused errors is proposed and a Clarke transformation-based DFT synchrophasor estimation algorithm is proposed to implement the theory in this paper. The Clarke transformation constructs a second signal that has exactly 90° phase angle difference from the original single-phase input signal and helps eliminate the estimation errors for a wide frequency range. The proposed algorithm is tested under the conditions required in the phasor measurement unit standard C37.118.1-2011 and C37.118.1a-2014, as well as the harmonic and noise conditions not required in the standard to verify its performance. More importantly, the idea of using Clarke transformation can be used for other DFT-based synchrophasor algorithms in order to achieve higher synchrophasor measurement accuracy under dynamic conditions. An example is presented at last to demonstrate the expandability of the proposed idea.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phasor-Measurement-Unit-Based Data Analytics Using Digital Twin and PhasorAnalytics Software

A major objective of this project was to apply GE’s commercial machine learning and data analytics toolsets to large-scale, real-world, anonymized Phasor Measurement Unit (PMU) datasets in order to extract signatures, correlated and/or causal factors, and precursor patterns associated with significant power system phenomena. The project had a particular emphasis on extraction of insights relevant to asset health monitoring, real-time load modeling and cybersecurity monitoring. Additionally, the team was directed to undertake a comprehensive data quality analysis for the provided datasets and encouraged to estimate the ‘machine-learning readiness’ of the datasets by documenting any major obstacles to the application of commercial machine learning algorithms. To accomplish the aforementioned objectives, the project team’s work centered around the identification of key event signatures and application of the identified event signatures for event detection and event classification. The industry-validated, semi-supervised machine learning strategy employed for event signature identification involved several major tasks, including data-preprocessing, generation of an overabundance of features, normal data identification, normality modeling, and event signature identification through a methodical, quantitative ranking of features in order of relevance to each studied event type. Throughout the project, data quality issues and mitigation techniques were investigated. In this report, insights are provided regarding the readiness of the provided synchrophasor datasets for application of machine learning and data analytics. The methodologies employed for this technical strategy are summarized in this report. With regards to data preprocessing and feature generation, the provided Training and Test Datasets were ingested into GE’s big data environment. Subsequently, the team applied bad data cleansing and data imputation scripts, event detection scripts, and application programming interfaces (APIs) to the datasets for convenient data access. The project team completed development and validation of dozens of physics-based, statistics-based and transformation-based feature functions used for the extraction of over 60 synchrophasor features. Using a new parallel feature generation technology developed on this project, over 60 features have been rapidly generated for the full two years’ worth of Training and Test Dataset data associated with both the Eastern and Western interconnects. Even accommodating for temporal down-sampling inherent to the feature extraction procedure, this parallel feature generation activity resulted in a massive feature set with a storage requirement approximately equal to that of the raw training dataset itself. With regards to normal data identification and normality modeling, a normality model was built using the feature data extracted from the Training Dataset and iteratively refined subsequent to incremental adjustments and expansions of the Training Dataset feature data. With respect to event characterization and signature identification, an event signature identification pipeline was developed and used in conjunction with the normality model to identify over 15 event signatures for key event categories within the Training Dataset. The identified event signatures were used to characterize hundreds of key events in terms of relative severity, duration, and location of the event. An investigation was undertaken to identify correlated and causal factors involved in transformer events. A separate investigation into temporal trends in ring-down analysis results was undertaken to determine possible associations between system dynamics and various other factors such as loading, season or year. To validate the identified event signatures, additional work was undertaken to develop signature-based anomaly detection and classification tools suitable for convenient application to the synchrophasor datasets. The anomaly detection and classification tools, suitable for online application, were then applied to the entirety of the Eastern Interconnect Training and Test Datasets. Performance of the event detection and classification tools was evaluated upon receipt of the Test Dataset event logs (i.e., the labels for events contained in the Test Dataset), and promising results were obtained despite several challenges (documented herein) associated with application of supervised or semi-supervised machine learning methods to large-scale, anonymized datasets. Finally, the detection and classification tools were used to detect, classify, and characterize thousands of new events not included in the original event logs provided by the DOE within both the Training and Test Datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

SHARP-Net: Platform for Self-Healing and Attack Resilient PMU Networks

Synchrophasor technology plays a pivotal role in developing the next generation of wide-area monitoring, protection, and control in the smart grid environment. As technology and communications infrastructures evolve, however, so do the attack surfaces in the synchrophasor network that can be exploited by advanced persistent threat (APT) actors to affect power system stability and reliability. In this paper, we propose a novel platform for developing a self-healing and attack-resilient PMU network (SHARP-Net) by instituting a state-of-the-art intrusion detection system (IDS) with an intrusion mitigation system (IMS) and an alert management system (AMS). In particular, the proposed platform detects anomalies during cyberattacks on phasor data concentrators (PDCs) based on the rules defined in the IDS, then the generated alerts are published to the IMS through the AMS. The proposed IMS proceeds to take automated corrective responses to mitigate cyberattacks by reconfiguring the synchrophasor network to isolate the compromised PDCs, and it orchestrates new PDCs to prevent the future propagation of attacks. Further, the IMS restores the system's observability by reconnecting the new PDCs to make the grid attack-resilient. In this work, the SHARP-Net platform is developed by using Python-based libraries, minimega's software-defined network, and virtual machine orchestration. We implement and validate the proposed SHARP-Net architecture by testing a PMU network in the smart grid environment. SHARP-Net showed promising performance in detecting cyberattacks and mitigating them through the network reconfiguration.

computer architecture↗

Application of Advanced Wide Area Early Warning Systems with Adaptive Protection

Recent blackouts of power systems in North America and throughout the world have shown how critical a reliable power system is to modern societies, and the enormous economic and societal damage a blackout can cause. It has been noted that unanticipated operation of protection systems can contribute to cascading phenomena and, ultimately, blackouts. This project developed and field-tested two methods of Adaptive Protection systems utilizing synchrophasor data. One method detects conditions of system stress that can lead to unintended relay operation, and initiates a supervisory signal to modify relay response in real time to avoid false trips. The second method detects the possibility of false trips of impedance relays as stable system swings “encroach” on the relays’ impedance zones, and produces an early warning so that relay engineers can re-evaluate relay settings. In addition, real-time synchrophasor data produced by this project was used to develop advanced visualization techniques for display of synchrophasor data to utility operators and engineers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Big-Data Analytics for Electric Grid and Demand-Side Management

This report describes research to characterize the status of, and trends in, big-data analytics for the electricity grid. The research focused on 1) identifying power-grid big-data sources, types, and characteristics; and 2) characterizing big-data architecture, analytic methods, technology applications, and challenges. The first part of this report describes the main sources and characteristics of big data for the smart grid and comprehensively reviews big-data architecture, technologies, and applications in the power sector. The second part of this report presents case studies of big data applications in the power industry: (1) a smart-meter data and predictive analytics method for demand response (DR), (2) synchrophasor data analytics for the distribution grid, and (3) utility data for peak-demand management. For the predictive analytics case study, smart-meter-data-driven and physical models were developed to predict the potential kilowatt (kW) capacity reduction from DR. The DR estimation framework that was developed works for both small and large-scale customers. The synchrophasor case study demonstrates use of an algorithm applied to time-series data to detect events that appear as significant changes, known as “edges,” in voltage magnitude measurements. The synchrophasor case study also introduces an approach for clustering sets of events to reveal unique features that distinguish them (e.g., distinguishing capacitor bank switching from transformer tap changes). The peak-demand management case study describes the use of the data analytics to enable DR programs to limit forecasted peak demand, resulting in cost savings to the utility. The findings from the research described in this report support identification of opportunities and technologies for big-data and analytics applications for demand-side management in the power sector as well as other approaches to modernizing the electricity grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗