Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchrotron Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Deformation Behavior of β Phase in a WE54 Magnesium Alloy

Second phases play a significant role in the development of high-performance magnesium alloys with rare earth elements. Here, in situ tensile tests combined with synchrotron radiation were carried out to investigate the deformation behavior of β phases in a WE (Mg–Y–Gd–Nd) alloy. By lattice strain analysis, it was found that micro load continuously transferred from the soft α-Mg matrix to the hard β phases during the whole plastic deformation, while this behavior was much more obvious at the beginning of deformation. Based on diffraction peak broadening, Williamson–Hall (W–H) plotting was used to study the microstrain of β phases. The results showed that the microstrain of β phases increased rapidly within 4% plastic strain and reached the maximum at plastic strain of ~6.5%. Since the β phases acted as hard phases, the microstrain was considered as a sign of the stress concentration near phase interfaces. It was also suggested that the effective release of local stress concentration at the β/α-Mg interface benefited the ductility of the WE alloy by the plastic deformation of β phases and phase interface sliding.

36 MATERIALS SCIENCE↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Transverse Beam Emittance Measurement by Undulator Radiation Power Noise

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.

43 PARTICLE ACCELERATORS↗

Subthreshold Erosion of an Organic Polymer Induced by Multiple Shots of an X-Ray Free-Electron Laser

We report solids irradiated by energetic photons can be eroded in two modes, depending on the radiation intensity. High average, low-peak power sources, e.g., synchrotron radiation and high-order harmonics, induce desorption of the material at a low etch rate. In contrast, high-peak-power radiation from extreme ultraviolet and x-ray lasers usually causes a massive removal of the material even by a single shot. In this contribution, an effective material erosion is reported in PMMA exposed to multiple accumulated pulses generated by the free-electron x-ray-laser Linac Coherent Light Source (LCLS, tuned at a photon energy of 830 eV in this study, operated in Menlo Park at Stanford, CA, USA) at a fluence below the single-pulse ablation threshold. The effect is caused by polymer-chain scissions initiated by single photons carrying enough energy to break the C—C bounds. High efficiency of the erosion is supposed to occur due to a correlation of the single-photon effects. The subthreshold damage exhibits a nonlinear dose dependence resulting from a competition between chain scissions and cross-linking processes. The cross-linking is proven by Raman spectroscopy of the irradiated polymer. Two theoretical models of the x-ray free-electron-laser-induced erosion are suggested, which provide an excellent agreement with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing extreme states of matter using ultra-intense x-ray radiation

Extreme states of matter, that is, matter at extremes of density (pressure) and temperature, can be created in the laboratory either statically or dynamically. In the former, the pressure–temperature state can be maintained for relatively long periods of time, but the sample volume is necessarily extremely small. When the extreme states are generated dynamically, the sample volumes can be larger, but the pressure–temperature conditions are maintained for only short periods of time (ps to μs). In either case, structural information can be obtained from the extreme states by the use of x-ray scattering techniques, but the x-ray beam must be extremely intense in order to obtain sufficient signal from the extremely-small or short-lived sample. In this article I describe the use of x-ray diffraction at synchrotrons and XFELs to investigate how crystal structures evolve as a function of density and temperature. After a brief historical introduction, I describe the developments made at the Synchrotron Radiation Source in the 1990s which enabled the almost routine determination of crystal structure at high pressures, while also revealing that the structural behaviour of materials was much more complex than previously believed. I will then describe how these techniques are used at the current generation of synchrotron and XFEL sources, and then discuss how they might develop further in the future at the next generation of x-ray lightsources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Properties of the Prompt Optical Counterpart Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work extends a contemporaneous effort to study the properties of the lower-energy counterpart synchrotron emission produced by the cooling of relativistic gamma-ray burst (GRB) electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses. We derive the major characteristics (pulse duration, lag time after burst, and brightness relative to the burst) of the prompt optical counterpart (POC) occurring during or after the GRB. Depending on the magnetic field lifetime, duration of electron injection, and electron transit time Δt o from hard X-ray (GRB) to optical-emitting energies, a POC may appear during the GRB pulse (of duration δt γ ) or after (delayed OC). The signature of counterparts arising from the cooling of GRB electrons is that POC pulses (Δto < δtγ) last as long as the corresponding GRB pulse (δt o ≃ δt γ ), while delayed OC pulses (Δt o > δt γ ) last as long as the transit time (δt o ≃ Δt o ). If OC variability can be measured, then another signature for this OC mechanism is that the GRB variability is passed on to POCs but not to delayed OCs. Within the GRB electron cooling model for counterparts, POCs should be on average dimmer than delayed ones (consistent with the data), and harder GRB low-energy slopes β LE should be associated more often with the dimmer POCs. The latter sets an observational bias against detecting POCs from (the cooling of electrons in) GRBs with a hard slope β LE , making it more likely that the detected POCs of such bursts arise from another mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Limits on Leptonic TeV Emission from the Cygnus Cocoon with Swift-XRT

$\gamma$-ray observations of the Cygnus Cocoon, an extended source surrounding the Cygnus X star-forming region, suggest the presence of a cosmic ray accelerator reaching energies up to a few PeV. The very-high-energy (VHE; 0.1-100~TeV) $\gamma$-ray emission may be explained by the interaction of cosmic-ray hadrons with matter inside the Cocoon, but an origin of inverse Compton radiation by relativistic electrons cannot be ruled out. Inverse Compton $\gamma$-rays at VHE are accompanied by synchrotron radiation peaked in X-rays. Hence, X-ray observations may probe the electron population and magnetic field of the source. We observed eleven fields in or near the Cygnus Cocoon with the Neil Gehrels Swift Observatory's X-Ray Telescope (Swift-XRT) totaling 110 ksec. We fit the fields to a Galactic and extra-galactic background model and performed a log-likelihood ratio test for an additional diffuse component. We found no significant additional emission and established upper limits in each field. By assuming that the X-ray intensity traces the TeV intensity and follows an dN/dE ∝ E -2.5 spectrum, we obtained a 90% upper limit of F X < 8.7 x 10 -11 erg cm -2 s -1 or 5.2 x10 -11 erg cm -2 s -1 on the X-ray flux of the entire Cygnus Cocoon between 2 and 10 keV depending on the choice of hydrogen column density model. This suggests that no more than one quarter of the $\gamma$-ray flux at 1 TeV is produced by inverse Compton scattering, when assuming an equipartition magnetic field of ~20 μG.

79 ASTRONOMY AND ASTROPHYSICS↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Optical Diagnostics with Undulator Radiation for EIC Hadron Ring

Optical diagnostics is widely used for measurement of the electron beam parameters such as bunch length, beam size, and emittance. Using undulator radiation extends these measurements to the beam energy and energy spread. In this paper, we will study the applicability of synchrotron radiation for protons.

43 PARTICLE ACCELERATORS↗

The Synchrotron Low-energy Spectrum Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work is a continuation of a previous effort (Panaitescu) to study the cooling of relativistic electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses, with application to the spectra and light curves of the synchrotron gamma-ray burst (GRB) produced by such cooling electrons. Here, we derive the low-energy slope β LE of a GRB pulse-integrated spectrum and quantify the implications of the measured distribution of β LE . Radiative processes that produce soft integrated spectra can accommodate the harder slopes measured by CGRO/BATSE and Fermi/GBM only if the magnetic field lifetime t B is shorter than the time during which the typical GRB electrons cool to radiate below 1–10 keV, which is less than (at most) 10 radiative cooling timescales t rad of the typical GRB electron. In this case, there is a one-to-one correspondence between t B and β LE . To account for low-energy slopes β LE > -3/4, the adiabatic electron-cooling requires a similar restriction on t B . In this case, the diversity of slopes arises mostly from how the electron-injection rate varies with time (temporal power-law injection rates yield power-law low-energy GRB spectra) and not from the magnetic field timescale.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

Characterizing sample degradation from synchrotron based X-ray measurements of ultra-thin exfoliated flakes

It is undeniable that novel 2D devices and heterostructures will have a lasting impact on the advancement of future technologies. However, the inherent instability of many exfoliated van der Waals (vdW) materials is a well-known hurdle yet to be overcome. Thus, the sustained interest in exfoliated vdW materials underscores the importance of understanding the mechanisms of sample degradation to establish proactive protective measures. Here, the impact of prolonged synchrotron-based X-ray beam exposure on exfoliated flakes of two contemporary vdW materials, NiPS 3 and α-RuCl 3 , is explored using resonant inelastic X-ray scattering (RIXS) and total fluorescence yield X-ray absorption spectroscopy (XAS). In NiPS 3 , the resulting RIXS and XAS spectra show a suppression, then vanishing, of NiS 6 multiplet excitations coupled with an upward shift of the peak energy of the XAS as a function of X-ray dose. In α-RuCl 3 , the signs of beam damage from the RIXS spectra are less evident. However, the post-experiment characterization of both materials using Raman spectroscopy exhibits signals of an amorphous and disordered system compared to pristine flakes; in addition, energy-dispersive X-ray spectroscopy of NiPS 3 shows evidence of ligand vacancies. As synchrotron radiation is fast becoming a required probe to study 2D vdW materials, these findings lay the groundwork for the development of future protective measures for synchrotron-based prolonged X-ray beam exposure, as well as for X-ray free electron laser.

2D magnetism↗

Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion

An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗

Characterization and Speciation of Marine Materials Using Synchrotron Probes: Guidelines for New Users

Synchrotron instruments are useful for marine studies because they make nondestructive measurements of chemical composition and speciation on small sample volumes and at low concentrations. Synchrotron beamtime is available without cost using a peer-reviewed proposal system. New users do not have to be synchrotron radiation experts to design a good experiment, but some guidance is needed to design and propose appropriate experiments. Here we present some of that guidance to encourage and increase access to synchrotron facilities for marine science. We provide advice and examples from experts on how to access these instruments, choose the optimal sample preparation, and avoid common pitfalls. We then present some examples of successful marine studies that use these techniques.

36 MATERIALS SCIENCE↗

Looking in the axion mirror: An all-sky analysis of stimulated decay

Axion dark matter (DM) produces echo images of bright radio sources via stimulated decay. These images appear as a faint radio line centered at half the axion mass, with the line width set by the DM velocity dispersion. Due to the kinematics of the decay, the echo can be emitted in the direction nearly opposite to the incoming source of stimulating radiation, meaning that axions effectively behave as imperfect monochromatic mirrors. We present an all-sky analysis of axion DM-induced echo images using extragalactic radio point sources, Galactic supernova remnants (SNRs), and Galactic synchrotron radiation (GSR) as sources of stimulating radiation. The aggregate signal strength is not significantly affected by unknown properties of individual sources of stimulating radiation, which we sample from an empirical distribution to generate an ensemble of realizations for the all-sky signal template. We perform forecasts for CHIME, HERA, CHORD, HIRAX, and BURSTT, finding that they can run as competitive axion experiments simultaneously with other objectives, requiring no new hardware.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental 4D Tracking of a Single Electron in IOTA

We present the results of the first experiments on 4-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. During the next few months, full 6D tracking will be implemented. This technology makes it possible to characterize the motion of a single particle, i.e. simultaneously tracking of amplitudes and phases for slow synchrotron oscillations and fast betatron oscillations. Complete tracking of a single particle enables the first direct measurements of dynamical properties, including invariants, amplitude-dependent tunes, and chaotic behavior.

43 PARTICLE ACCELERATORS↗