Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Analysis Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Time-domain Modulation of HD 189733 Activities by Its Planet

Star–planet interaction can be studied by analyzing exoplanetary orbit and stellar rotation modulations of the transit emissions from exoplanetary systems. Here we carry out a time-domain analysis of the multiband activities of the HD 189733 star–planet system observed in X-ray, atomic lines, and broadband spectra reported in the literature. We find that the number of activities occuring at beat angles (of the planetary orbit and the stellar rotation) concentrating on a sector with a width of 108° are significantly larger than expected from a uniform distribution of activities, which indicates the existence of a major stellar active magnetic field region. The concentration of activities in this active magnetic field region shows their possible origins from the magnetic field interaction between HD 189733 and its close planet HD 189733 b.

47 OTHER INSTRUMENTATION↗

Analysis of Alternative Core Designs for Fission Surface Power Capability Demonstration Mission (V.1.0)

NASA’s Space Technology Mission Directorate (STMD) intends to demonstrate a 10 kWe fission surface power (FSP) system on the surface of the Moon as part of a Capability Demonstration Mission. STMD tasked a joint NASA-DOE team to ‘outline an FSP reactor concept that can be readied for 2027 launch,’ and serves ‘as a pathfinder for future power modules for Mars.’ Tables 1 and 2 respectively list FSP performance requirements and design guidance provided for the study. DOE is the leading agency for the reactor module, reactor controls and radiation shielding, and shares joint responsibility for the overall FSP system. This report summarizes an analysis of alternative reactor classes and shielding configurations carried out by the DOE national laboratories. Representative reactor and shielding configurations were based on heritage and are in alignment with the industry initiatives. This report presents no recommendations on the appropriate choice of fuel or class of reactor that NASA should pursue. Instead the focus here is to provide a summary and findings of analyses carried out by DOE national laboratory personnel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FARM User Guidance and Instructions

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, the general workflow and the software requirements of FARM module are summarized, and the detailed instructions for installing FARM software, running built-in example cases, deriving Linear Parameter-Varying (LPV) state-space models, and using FARM for user-defined power dispatch problems are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comprehensive Efficiency Analysis of Current Source Inverter Based SPM Machine Drive System for Traction Applications

A current-source inverter (CSI) has the natural capability of boosting the output voltage which is a notable advantage over voltage source inverter (VSI) in traction drive applications. This paper investigates the voltage boosting feature of the CSI to improve the overall efficiency of the CSI-based surface permanent magnet (SPM) machine drive system in the constant power region. The effects of the boost function on the total system losses, including the machine copper loss, core loss, and magnet loss, as well as the device conduction and switching loss in the CSI and dc/dc converter, are described using analytical models. The operating characteristics of the machine and CSI are validated by 2-D finite-element analysis (FEA) and simulations. Based on the loss model, the effects of the modulation index on the overall drive system losses and power factor have been analyzed. A genetic algorithm has been used to optimize the CSI's boost ratio, demonstrating that the drive system efficiency can be increased by 1% to 2.5% along the constant-power regime envelope by using the boost function.

current source inverter, genetic algorithm, SPM ma↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

LPS-Induced Inflammation Prior to Injury Exacerbates the Development of Post-Traumatic Osteoarthritis in Mice

ABSTRACT Osteoarthritis (OA) is a debilitating and painful disease characterized by the progressive loss of articular cartilage. Post-traumatic osteoarthritis (PTOA) is an injury-induced type of OA that persists in an asymptomatic phase for years before it becomes diagnosed in ~50% of injured individuals. Although PTOA is not classified as an inflammatory disease, it has been suggested that inflammation could be a major driver of PTOA development. Here we examined whether a state of systemic inflammation induced by lipopolysaccharide (LPS) administration 5-days before injury would modulate PTOA outcomes. RNA-seq analysis at 1-day post-injury followed by micro-computed tomography (μCT) and histology characterization at 6 weeks post-injury revealed that LPS administration causes more severe PTOA phenotypes. These phenotypes included significantly higher loss of cartilage and subchondral bone volume. Gene expression analysis showed that LPS alone induced a large cohort of inflammatory genes previously shown to be elevated in synovial M1 macrophages of rheumatoid arthritis (RA) patients, suggesting that systemic LPS produces synovitis. This synovitis was sufficient to promote PTOA in MRL/MpJ mice, a strain previously shown to be resistant to PTOA. The synovium of LPS-treated injured joints displayed an increase in cellularity, and immunohistological examination confirmed that this increase was in part attributable to an elevation in type 1 macrophages. LPS induced the expression of Tlr7 and Tlr8 in both injured and uninjured joints, genes known to be elevated in RA. We conclude that inflammation before injury is an important risk factor for the development of PTOA and that correlating patient serum endotoxin levels or their state of systemic inflammation with PTOA progression may help develop new, effective treatments to lower the rate of PTOA in injured individuals. © 2020 The Authors. Journal of Bone and Mineral Research published by American Society for Bone and Mineral Research.

59 BASIC BIOLOGICAL SCIENCES↗

Database Management Module Framework for Dynamic Contingency Analysis and Visualization

The Dynamic Contingency Analysis Tool (DCAT) is being developed to mimic the response of generation dynamics, protection, and load components to extreme contingencies in power systems. Currently, DCAT generates a huge data set, with the analysis results stored in multiple subfolders using a great many files in different formats (power flow cases, time series, figures, spreadsheets). To help power system engineers thoroughly understand and analyze system behavior under many scenarios and contingencies, we developed a database management module (DBM) that enables future integration of DCAT with industry-grade Big Data analytical and interactive visualization platforms. In this paper, we demonstrate the DBM framework with interactive analytics and visualization for DCAT on the synthetic South Carolina 500-bus power system model using hurricane contingencies that capture possibilities for an extreme contingency. DCAT’s advanced data management and interactive visualization can help planning engineers to visually explore and analyze system behavior, all in one view.

Cascading, dynamic simulations, database managemen↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Latest developments in the MOOSE fluid properties module

The fluid properties module in MOOSE serves a variety of fluid simulation applications based on MOOSE, including the MOOSE Navier Stokes module~\cite{moose_ns}, Pronghorn~\cite{pgh}, SAM~\cite{sam}, the MOOSE thermal hydraulics module, RELAP-7~\cite{relap7} and subchannel~\cite{subchannel}. It is used for coarse mesh multi-dimensional thermal-hydraulics~\cite{pgh}, 1D systems analysis~\cite{sam,relap7} in nuclear reactor analysis, and porous flow simulations~\cite{porous} for underground gas storage and water seepage. The use of consistent fluid properties across fluid flow applications facilitates coupled simulations~\cite{anl_sam_pgh}. The module offers a consistent set of interfaces to implement to create a new fluid property. There are numerous fluid properties of interest in the entirety of all fields of fluid flow simulations, and this is exacerbated by the use of different variable sets depending on the compressibility of the fluid. For single-phase fluids, the following variable sets may be used to compute fluid properties: (pressure, temperature) and (specific volume, specific internal energy). Some properties may also be computed using the (pressure, density) or the (specific volume, specific enthalpy) variable sets. In order to reduce the challenge of adding a new fluid property, properties may be implemented partially.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

PVcircuit [SWR-22-26]

The software contains objects that are building blocks for PV modeling and interactive data fitting based on: Optoelectronic models for tandem/multijunction solar cells including resistive and luminescent coupling; simulation of modules composed of 2T, 3T, and 4T tandem solar cells; and energy yield analysis of PV systems composed of tandem solar cells.

Geisz, John↗

PVcircuit v0.0.6 [SWR-22-26]

The software contains objects that are building blocks for PV modeling and interactive data fitting based on: Optoelectronic models for tandem/multijunction solar cells including resistive and luminescent coupling; simulation of modules composed of 2T, 3T, and 4T tandem solar cells; and energy yield analysis of PV systems composed of tandem solar cells.

Geisz, John↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influences of Alkali Metal Cation Interactions on N2 Coordination to Iron(I) Beta-Diketiminate Complexes in Electrolyte Solutions

N2 functionalization reactions often use stable, isolable N2-bound complexes and low temperatures or highly activated reagents. However, little work has focused on systems where N2 binds weakly, and the N2 binding equilibrium can be modulated. Here, we describe analysis of surprising trends in alkali metal cation solvation on the formation of an anionic iron(I) beta-diketiminate complex and the subsequent N2 binding equilibrium. Variable temperature UV-vis spectroscopy shows that increased ionic strength in the coordinating solvent tetrahydrofuran promotes N2 coordination. Additionally, less solvated alkali metal cations in noncoordinating 2-methyltetrahydrofuran (MeTHF) stabilize N2 coordination, likely through the formation of contact ion pairs in solution that have enhanced N2 binding. Ionic strength has little effect on the energetics of N2 coordination to these proposed contact ion pairs in MeTHF. When the electrochemical analysis is done at –78 °C, there is an irreversible reduction of iron(II) and an anodically shifted oxidation, which is attributed to the formation of the spectroscopically observed N2 complex. Finally, bulk electrolysis is used to verify the electrochemical formation of the N2-bound anionic iron(I) complex. These studies demonstrate a new strategy for promoting N2 coordination by changing solution properties, which is relevant to homogeneous electrochemical N2 reduction methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗