Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multi-Timescale Three-Phase Unbalanced Distribution System Operation With Variable Renewable Generations

This paper proposes a multi-timescale operational approach for a three-phase unbalanced distribution system, which contains hourly scheduling at substation level and minutes power flow operation at feeder level. In the substation scheduling model, the objective is to minimize the system cost with variable renewable generations. The given error distribution model of renewable generation is formulated as a chance constraint, and derived into a deterministic form by Gaussian mixture model (GMM) with genetic algorithm-based expectation-maximization (GAEM). In the feeder scheduling model, the system cost is further reduced with the optimal power flow (OPF) at a timescale of minutes. Considering the nonconvexity of the three-phase unbalanced OPF problem in distribution systems, the semidefinite programming (SDP) is used to relax the problem into a convex problem, and a distributed computation approach is built based on alternating direction method of multiplier (ADMM). The IEEE 123-bus distribution system, DU (University of Denver) campus distribution system, and the IEEE 8500-bus distribution system are used as the test bench for the proposed approach. And the numerical results demonstrate the effectiveness and validity of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of the Need for and Design of a City Energy Operations System

There is growing interest in city and community scale energy efficiency goals across the US and around the world [1]. Forward thinking developers are expressing interest in developing methods to track the actual operations of new urban developments and campuses. Local governments and developers are exploring how to ensure that the built infrastructure, including buildings, transportation, energy generation and storage assets, is not only designed for energy efficiency, but operates efficiently as well. There is a need for city and district scale tools to support energy analysis from design through operations. Smart city data analytics is a growing area of interest in the smart city technology space. However, while there is enthusiasm for the concept of smart city energy analytics, there is a lack of common semantic data models, interoperable systems, and methods to collect data and support decision-making for operating multi-building city- and district-scale energy systems. Urban developers are asking broad questions about how such a system might be designed, built, valued, maintained, and optimized. This paper describes ongoing research to explore and define a City or District Energy Operations System (CityEOS).

Piette, Mary Ann↗

Transient Plume Model Testing Using LADEE Spacecraft Attitude Control System Operations

The Lunar Atmosphere Dust Environment Explorer (LADEE) spacecraft is being designed for a mission featuring low altitude orbits of the Moon to take relevant ambient measurements before that environment becomes altered by future exploration activities. Instruments include a neutral mass spectrometer capable of measuring ambient species density levels below 100 molecules/cm{sup 3}. Coincidentally, with a favorable combination of spacecraft orientations, it is also possible to measure plume gases from LADEE attitude control system thruster operations as they are reflected from the daytime lunar surface and subsequently intercepted by the spacecraft as it orbits overhead. Under such circumstances, it may be possible to test a variety of properties and assumptions associated with various transient plume models or to infer certain aspects regarding lunar surface properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the Impact of Interconnect Failures on System Operation

Hardware failures are inevitable on large high performance computing systems. Faults or performance degradations in the high-speed network can reduce the entire system s performance. Since the introduction of the Gemini interconnect, Cray systems have become resilient to many networking faults that were fatal in their previous generation systems. These new network reliability and resiliency features have enabled higher uptimes on Cray systems by allowing them to continue running with reduced network performance. Oak Ridge National Laboratory has developed a set of user-level diagnostics that stresses the high-speed network and searches for components that are not performing as expected. Nearest-neighbor bandwidth tests check every network chip and network link in the system. Additionally, performance counters stored on the network ASIC s memory mapped registers (MMRs) are used to better understand the state of the network. Applications have also been characterized under various suboptimal network conditions to better understand what impact network problems have on user codes.

Cray↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of Pumped Storage Hydro Resources in Electricity Markets and System Operation: Preprint

The most common form of utility- sized energy storage system is the pumped storage hydro system. Originally, these types of storage systems were economically viable simply because they displace more expensive generating units. However, over time, as those expensive units became more efficient and costs declined, pumped hydro storage units no longer have the operational edge. As a result, in the current electricity market environment, pumped storage hydro plants are struggling. To offset this phenomenon, certain market modifications should be addressed. This paper will introduce some of the challenges faced by pumped storage hydro plants in today's markets and purpose some solutions to those problems.

13 HYDRO ENERGY↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorporating Wind Generation Forecast Uncertainty into Power System Operation, Dispatch, and Unit Commitment Procedures

In this paper, an approach to evaluate the uncertainties of the balancing capacity, ramping capability, and ramp duration requirements is proposed. The approach includes three steps: forecast data acquisition, statistical analysis of retrospective information, and prediction of grid balancing requirements for a specified time horizon and a given confidence level. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on histogram analysis, incorporating sources of uncertainty of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the "flying-brick" technique is developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation process is used to validate the accuracy of the confidence intervals. To demonstrate the validity of the developed uncertainty assessment methods and its impact on grid operation, a framework for integrating the proposed methods with an EMS system is developed. Demonstration through integration with an EMS system illustrates the applicability of the proposed methodology and the developed tool for actual grid operation and paves the road for integration with EMS systems from other vendors.

17 WIND ENERGY↗

More Than 410,000 Hours of Real-World Fuel Cell System Operation Have Been Analyzed by NREL's Technology Validation Team (Fact Sheet)

This fact sheet discusses how researchers at the National Renewable Energy Laboratory (NREL) are working to validate hydrogen and fuel cell systems in real-world settings. NREL strives to provide an independent third-party technology assessment that focuses on fuel cell system and hydrogen infrastructure performance, operation, maintenance, and safety.

08 HYDROGEN↗

Operating Systems Support for Advanced Programming Languages

As machines grow in scale and complexity, techniques to make the most effective use of network, memory, and processor resources will also become increasingly important. Programming models that rely on one-sided communication or global address space support have demonstrated advantages for productivity and performance, but they are most effective when used with proper OS support. We propose to develop OS and runtime support for programming models like UPC, GA, Charm++, and HPCS languages, which rely on one-sided communication. Rather than a full OS model, we envision applications bundled with only the necessary OS functions linked in to the application in user space -- relying on the hypervisor for protaction, resource sharing, and mangagement of Quality of Service guarantees. Our services will include support for remote reads and writes to memory, along with remote active message handlers, which are essential for support of fast noncontiguous memory operations, atomic operations, and event-driven applications.

97 MATHEMATICS AND COMPUTING↗

Hardware enabled performance counters with support for operating system context switching

A device for supporting hardware enabled performance counters with support for context switching include a plurality of performance counters operable to collect information associated with one or more computer system related activities, a first register operable to store a memory address, a second register operable to store a mode indication, and a state machine operable to read the second register and cause the plurality of performance counters to copy the information to memory area indicated by the memory address based on the mode indication.

97 MATHEMATICS AND COMPUTING↗

Incorporating Uncertainty of Wind Power Generation Forecast into Power System Operation, Dispatch, and Unit Commitment Procedures

An approach to evaluate the uncertainties of the balancing capacity, ramping capability, and ramp duration requirements is proposed. The approach includes three steps: forecast data acquisition, statistical analysis of retrospective information, and prediction of grid balancing requirements for a specified time horizon and a given confidence level. An assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on histogram analysis, incorporating sources of uncertainty - both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures). A new method called the 'flying-brick' technique is developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation process is used to validate the accuracy of the confidence intervals. To demonstrate the validity of the developed uncertainty assessment methods and its impact on grid operation, a framework for integrating the proposed methods with an EMS system is developed. Demonstration through EMS integration illustrates the applicability of the proposed methodology and the developed tool for actual grid operation and paves the road for integration with EMS systems in control rooms.

17 WIND ENERGY↗

ASNF Engineering Scale Drying Experiment System Operability Functional Requirements

This checklist specifies the functional requirements for the drying system installed at Holtec International under the scope of INL Contract # 215725, in collaboration with University of South Carolina under INL Contract Number 207046, consistent with the parameters described in INL/EXT-19-56017, Aluminum-clad Spent Nuclear Fuel Engineering Scale Drying Experiment Design. Completion of the ASNF Engineering Scale Drying Experiment Acceptance Criteria for Fabricated Items, INL/MIS-20-58551, is a prerequisite.

36 MATERIALS SCIENCE↗

Effects of adaptive automation on operator-system performance - 103

Adaptive automation (AA) is the dynamic, real-time change in the degree of automation in response to situational changes. AA systems are being developed in many industries, including for nuclear power plant applications. AA is a promising means of mitigating human performance issues that often arise in highly automated systems. The purpose of this Nuclear Regulatory Commission study was to characterize important AA design features, define the effects of AA on performance, examine the human factors engineering (HFE) guidance available to design and evaluate AA systems, and identify research and development needs. In general, we found that AA improves task performance and situation awareness (SA) while managing workload. Although the research is limited, AA also supports operator recognition of automation failure and recovery. Research on human-system interfaces has identified principles showing promise for supporting SA, including failure detection, and limiting workload. Research further suggests that AA systems are both more effective, and less disruptive and distracting, when they follow rules of interaction similar to those used by human crewmembers. Our general conclusion about the HFE guidance available to designers and reviewers is that it is limited and has not kept pace with automation technology. We discuss several research and development needs that will help support a better understanding of where and how AA should be used and support the development of more comprehensive guidance for AA safety reviews. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Best-Practices Guide for Photovoltaic System Operations and Maintenance

Fact sheet summarizing technical report TP-7A40-67553. As solar photovoltaic (PV) systems have continued their transition from niche applications into large, mature markets in the United States, their potential as financial investments has risen accordingly. Mainstream investors, however, need to feel confident about the risk and return of solar photovoltaic (PV) systems before committing funds. A major influence on risk and return for PV is operations and maintenance (O&M) - but O&M practices and costs vary widely across the United States, making these variables difficult for investors to predict. To address this barrier to continued PV investment, the PV O&M Working Group has developed a new best-practices guide for PV O&M.

14 SOLAR ENERGY↗

Performance of a superconducting magnet system operated in the Super Omega Muon beam line at J-PARC

A superconducting magnet system, which is composed of an 8 m long solenoid for transportation and 12 short solenoids for focusing, has been developed for Muon Science Establishment facility of J-PARC. The transport solenoid is composed of a 6 m straight section connected to a 45 degree curved section at each end. Muons of various momenta and of both electric charges are transported through the solenoid inner bore with an effective diameter of 0.3 m, where 2 T magnetic field is induced. There are 12 focusing solenoids with an effective bore diameter of 0.6 m and a length of 0.35 m arranged on a straight line at suitable intervals. The maximum central field of each focusing solenoid is 0.66 T. All solenoid coils are cooled by GM cryocoolers through their own conductions. The magnet system has been installed into the beam line in the summer of 2012, and its performance has been checked. Beam commissioning has been carried out since October 2012. During beam operation, temperature rise over 6 K in the transport solenoid due to a nuclear heating from the muon production target is observed at beam intensity of about 300 kW.

43 PARTICLE ACCELERATORS↗

Room temperature, nanosecond, 60 mJ/pulse Fe:ZnSe master oscillator power amplifier system operating at 3.8-5.0 µm

We report on a RT gain-switched Fe:ZnSe master oscillator power amplifier (MOPA) system tunable over 3.8–5.0 µm pumped by radiation of Er:YAG laser operating at 2.94 µm. The mechanically Q-switched Er:YAG laser with output energy up to 220 mJ was used as a pump source for a master oscillator and three-stage power amplifier. The maximum output energies in 200 ns pulses exceeded 60, 56, and 48 mJ at 4.4, 4.3, and 4.1 µm, respectively, under 220 mJ of pump energy. The extraction energy efficiencies were measured to be 25, 30, and 40% at the first, second, and third stages, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗