Search NASA⌕ Search

SEARCH · Search NASA

Results for “TAPE RECORDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A high data rate recorder for astronomy

A magnetic tape recorder developed for the special requirements of radio astronomy and geodesy is described. These requirements include a high bit packing density and long record times. The current version of this longitudinal recorder used by the Very Long Baseline Array (VLBA) records 5.5 Terabits on a 14-in diameter reel of inch-wide tape. A maximum record rate of 256 Mb/s is achieved in the VLBA configuration with one recorder operating at 4 ms and utilizing 32 of the heads in a single stack. The VLBA recorders have been tested using a longitudinal density of 2.25 fr/micron; 448 data + 56 system tracks are recorded in 14 passes, each lasting 50 min, for a total record time (at 128 Mb/s) of 12 h on 14-in diameter reel of inch-wide 13-microns-thick D1-equivalent tape.

Hinteregger, H. F.↗

LANDSAT-2 and LANDSAT-3 Flight evaluation report

Flight performance analysis of LANDSAT 2 and LANDSAT 3 are presented for the period July 1978 to October 1978. Spacecraft operations and orbital parameters are summarized for each spacecraft. Data are provided on the performance and operation of the following subsystems onboard the spacecraft: power; attitude control; command/clock; telemetry; orbit adjust; magnetic moment compensating assembly; unified S band/premodulation processor; electrical interface; thermal narrowband tape recorders; wideband telemetry; attitude measurement sensor; wideband video tape recorders; return beam vidicon; multispectral scanner subsystem; and data collections.

Winchester, T. W.↗

Mark 3 wideband digital recorder in perspective

The tape recorder used for the Mark 3 data acquisition and processing system is compared with earlier very long baseline interferometry recorders. Wideband 33-1/3 kbpi digital channel characteristics of instrumentation recorders and of a modern video cassette recorder are illustrated. Factors which influenced selection of the three major commercial components (transport, heads, and tape) are discussed. A brief functional description and the reasons for development of efficient signal electronics and necessary auxiliary control electronics are given. The design and operation of a digital bit synchronizer is illustrated as an example of the high degree of simplicity achieved.

Hinteregger, H. F.↗

ERTS 1 flight evaluation report, 23 July 1974 to 23 October 1974

Analyses of ERTS-1 performance during the ninth quarter of its operation are presented. Topics discussed include orbital parameters, power subsystem, attitude control subsystem, command/clock subsystem, telemetry subsystem, orbit adjust subsystem, magnetic moment compensating assembly, unified S band/premodulation processor, electrical interface subsystem, thermal subsystem, narrowband tape recorders, wideband telemetry subsystem, attitude measurement sensor, wideband video tape recorders, return beam vidicon subsystem, multispectral scanner subsystem, and data collection system.

Source record↗

Landsat-1 and Landsat-2 evaluation report, 23 January 1975 to 23 April 1975

A description of the work accomplished with the Landsat-1 and Landsat-2 satellites during the period 23 Jan. - 23 Apr. 1975 was presented. The following information was given for each satellite: operational summary, orbital parameters, power subsystem, attitude control subsystem, command/clock subsystem, telemetry subsystem, orbit adjust subsystem, magnetic moment compensating assembly, unified S-band/premodulation processor, electrical interface subsystem, thermal subsystem, narrowband tape recorders, wideband telemetry subsystem, attitude measurement sensor, wideband video tape recorders, return beam vidicon, multispectral scanner subsystem, and data collection subsystem.

Source record↗

Landsat-1 and Landsat-2 flight evaluation

The flight performance of Landsat 1 and Landsat 2 is analyzed. Flight operations of the satellites are briefly summarized. Other topics discussed include: orbital parameters; power subsystem; attitude control subsystem; command/clock subsystem; telemetry subsystem; orbit adjust subsystem; magnetic moment compensating assembly; unified s-band/premodulation processor; electrical interface subsystem; thermal subsystem; narrowband tape recorders; wideband telemetry subsystem; attitude measurement sensor; wideband video tape recorders; return beam vidicon; multispectral scanner subsystem; and data collection subsystem.

Source record↗

Specification for wide channel bandwidth one-inch video tape

Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

Perry, Jimmy L.↗

Airoscope telemetry system

The AIROscope (Ames Infrared Observatory telescope) telemetry system is described from signal conditioning on the gondola to display and storage at the ground station. All analog and digital data from the systems and experiments on the gondola go to a PCM encoder which formats the data into 10-bit words. Therefore, 0.1-percent resolution is inherently available for experimental data. The coded bit stream directly modulates the carrier of the FM transmitter. To insure reliable transmission over a 650-km range an 11-watt FM transmitter operating at 1483.5 MHz is used on the gondola. Modulation is narrow band FM with a maximum deviation of plus or minus 500 kHz. The maximum modulation frequency is determined by the data bit rate which could be as high as 500 kbps. Presently, a rate of 20.48 kbps is used. The ground station receiving system includes a steerable antenna (19-db gain), preamplifier (21-db gain) and receiver. All data are recorded on a tape recorder. The recorded signal then can be played back through the PCM decommutator unit at a later time for detailed data analysis by the experimenter.

Pitts, K. J.↗

The use of airborne imaging spectrometer data to determine experimentally induced variation in coniferous canopy chemistry

It was experimentally determined whether induced differences in forest canopy chemical composition can be detected using data from the Airborne Imaging Spectrometer (AIS). Treatments were applied to an even-aged forest of Douglas fir trees. Work to date has stressed wet chemical analysis of foilage samples and correction of AIS data. Plot treatments were successful in providing a range of foliar N2 concentrations. Much time was spent investigating and correcting problems with the raw AIS data. Initial problems with groups of drop out lines in the AIS data were traced to the tape recorder and the tape drive. Custom adjustment of the tape drive led to recovery of most missing lines. Remaining individual drop out lines were replaced using average of adjacent lines. Application of a notch filter to the Fourier transform of the image in each band satisfactorily removed vertical striping. The aspect ratio was corrected by resampling the image in the line direction using nearest neighbor interpolation.

Swanberg, Nancy A.↗

First Galileo image of asteroid 243 Ida

The second spacecraft encounter with an asteroid has yielded an unprecedentedly high resolution portrait of 243 Ida. On 28 Aug. 1993, Galileo obtained an extensive data set on this small member of the Koronis family. Most of the data recorded on the tape recorder will be returned to Earth in spring 1994. A five-frame mosaic of Ida was acquired with good illumination geometry a few minutes before closest approach; it has a resolution of 31 to 38 m/pixel amd was played back during Sept. 1993. Preliminary analyses of this single view of Ida are summarized.

Chapman, C. R.↗

Fluid Dynamic Verification Experiments on STS-70

Fluid dynamic experiments were flown on STS-70 as phase two of the engineering evaluation of the first bioreactor Engineering Development Unit (EDU#1). The phase one experiments were comparative cell cultures in identical units on earth and onboard STS-70. In phase two, two types of fluid dynamic experiments were performed. Qualitative comparisons of the basic flow patterns were evaluated with the use of 'dye' streaklines formed from alternate injections of either a mild acid or base solution into the external flow loop that was then perfused into the vessel. The presence of Bromothymol Blue in the fluid then caused color changes from yellow to blue or vice versa, indicating the basic fluid motions. This reversible change could be repeated as desired. In the absence of significant density differences in the fluid, the flow patterns in space should be the same as on earth. Video tape records of the flow patterns for a wide range of operating conditions were obtained. The second type of fluid dynamic experiment was the quantitative evaluation of the trajectories of solid beads of various densities and sizes. The beads were introduced into the vessel and the paths recorded on video tape, with the vessel operated at various rotation rates and flow perfusion rates. Because of space limitations, the video camera was placed as close as possible to the vessel, resulting in significant optical distortion. This report describes the analysis methods to obtain comparisons between the in-flight fluid dynamics and numerical models of the flow field. The methods include optical corrections to the video images and calculation of the bead trajectories for given operating conditions and initial bead locations.

Kleis, Stanley J.↗

Description of the ISEE satellite-to-satellite kilometric wavelength interferometer system

The International Sun-Earth Explorer (ISEE) spacecraft 1 and 2 carry receivers for detecting electromagnetic waves with kilometric wavelengths. For selected receiver frequencies from 30 kHz to 2 MHz, a 10-kHz bandwidth channel is single-sideband mixed down to baseband. These analog data and a reference frequency, which is a submultiple of the local oscillator frequency, are transmitted to ground stations and tape recorded along with the precise time and frequency information. Cross correlation of these tape recorded signals constitutes a satellite-to-satellite interferometer with a fringe spacing of 0.4 to 41 arcmin (at a range of 10,000 to 100 km spacing between spacecraft for 250 kHz in frequency) and with a time-delay resolution of 32 microsec for a 10-kHz bandwidth, which gives an angular resolution of 3 min to 6 deg of arc. For kilometric radiation at earth, sources in the size range of 25 to 2500 km can be identified (from 20 earth radii) and located in relative position ranging from 0.02 to 2 earth radii, depending on spacecraft spacing. Reception and analysis of solar and Jovian bursts may also be possible.

Shawhan, S. D.↗

Linear modulator

A study of frequency division multiplexing (FDM) systems was made for the purpose of determining the system performance that can be obtained with available state of the art components. System performance was evaluated on the basis of past experience, system analysis, and component evaluation. The system study was specifically directed to the area of FDM systems using subcarrier channel frequencies from 4 kHz to 200 kHz and channel information bandwidths of dc to 1, 2, 4, 8, and 16 kHz. The evaluation also assumes that the demodulation will be from a tape recorder which produces frequency modulation of + or - 1% on the signal due to the tape recorder wow and flutter. For the modulation system it is assumed that the pilot and carrier channel frequencies are stable to within + or - .005% and that the FM on the channel carriers is negligible. The modulator system was evaluated for the temperature range of -20 degree to +85 degree while the demodulator system was evaluated for operation at room temperature.

Source record↗

Use of the Long Duration Exposure Facility's thermal measurement system for the verification of thermal models

Results are presented of the comparison between the Long Duration Exposure Facility (LDEF) Thermal Measurements Systems (THERM) recorded temperature data and the predicted values as calculated prior to the LDEF deployment. The postflight thermal model was verified and calculated temperature uncertainties were reduced to under + or - 18 F from the preflight uncertainties of + or - 40 F. The THERM consisted of 8 temperature sensors, a shared tape recorder, a standard LDEF flight battery, and an electronics control box. The temperatures were measured at selected locations on the LDEF structure interior during the first 490 days of flight and recorded for postflight analysis. After the recorder was recovered from space, the tape recorder was recovered and the data reduced for comparison to the LDEF predicted temperatures. By comparing the calculated values to the measured data, a verified thermal model that presents the best agreement with the THERM data was obtained. The THERM experiment provided an economical way of performing a postflight verification of the LDEF Thermal Model by recording a limited number of flight temperatures on typical locations of the LDEF structure.

Berrios, William M.↗

Data acquisition and analysis in the DOE/NASA Wind Energy Program

Four categories of data systems, each responding to a distinct information need are presented. The categories are: control, technology, engineering and performance. The focus is on the technology data system which consists of the following elements: sensors which measure critical parameters such as wind speed and direction, output power, blade loads and strains, and tower vibrations; remote multiplexing units (RMU) mounted on each wind turbine which frequency modulate, multiplex and transmit sensor outputs; the instrumentation available to record, process and display these signals; and centralized computer analysis of data. The RMU characteristics and multiplexing techniques are presented. Data processing is illustrated by following a typical signal through instruments such as the analog tape recorder, analog to digital converter, data compressor, digital tape recorder, video (CRT) display, and strip chart recorder.

Neustadter, H. E.↗

Long duration exposure facility post-flight thermal analysis, part 1

Results of the post-flight thermal analysis of the Long Duration Exposure Facility (LDEF) mission are presented. The LDEF mission thermal analysis was verified by comparing the thermal model results to flight data from the LDEF Thermal Measurements System (THERM). Post-flight calculated temperature uncertainties have been reduced to under +/- 18 F from the pre-flight uncertainties of +/- 40 F. The THERM consisted of eight temperature sensors, a shared tape recorder, a standard LDEF flight battery, and an electronics control box. The temperatures were measured at selected locations on the LDEF structure interior during the first 390 days of flight and recorded for post-flight analysis. After the LDEF retrieval from Space on 12 Jan. 1990, the tape recorder was recovered from the spacecraft and the data reduced for comparison to the LDEF predicted temperatures. The LDEF mission temperatures were calculated prior to the LDEF deployment on 7 Apr. 1980, and updated after the LDEF retrieval with the following actual flight parameter data: including thermal fluxes, spacecraft attitudes, thermal coatings degradation, and contamination effects. All updated data used for the calculation of post-flight temperatures is also presented in this document.

Berrios, William M.↗