Search NASA⌕ Search

SEARCH · Search NASA

Results for “TECHNETIUM 99”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Prolonged dipyridamole administration reduces myocardial perfusion defects in experimental chronic Chagas cardiomyopathy

Background: Myocardial perfusion defects (MPD) due to coronary microvascular dysfunction is frequent in chronic Chagas cardiomyopathy (CCC) and may be involved with development of myocardial damage. We investigated whether MPD precedes left ventricular systolic dysfunction and tested the hypothesis that prolonged use of dipyridamole (DIPY) could reduce MPD in an experimental model of CCC in hamsters. Methods and results: We investigated female hamsters 6-months after T. cruzi infection (baseline condition) and control animals, divided into T. cruzi-infected animals treated with DIPY (CH + DIPY) or placebo (CH + PLB); and uninfected animals treated with DIPY (CO + DIPY) or placebo (CO + PLB). The animals were submitted to echocardiogram and rest SPECT-Sestamibi-Tc99m myocardial perfusion scintigraphy. Next, the animals were treated with DIPY (4 mg/kg bid, intraperitoneal) or saline for 30 days, and reevaluated with the same imaging methods. At baseline, the CH + PLB and CH + DIPY groups showed larger areas of perfusion defect (13.2 ± 13.2% and 17.3 ± 13.2%, respectively) compared with CO + PLB and CO + DIPY (3.8 ± 2.2% e 3.5 ± 2.7%, respectively), P < .05. After treatment, we observed: reduction of perfusion defects only in the CH + DIPY group (17.3 ± 13.2% to 6.8 ± 7.6%, P = .001) and reduction of LVEF in CH + DIPY and CH + PLB groups (from 65.3 ± 9.0% to 53.6 ± 6.9% and from 69.3 ± 5.0% to 54.4 ± 8.6%, respectively, P < .001). Quantitative histology revealed greater extents of inflammation and interstitial fibrosis in both Chagas groups, compared with control group (P < .001), but no difference between Chagas groups (P > .05). Conclusions: The prolonged use of DIPY in this experimental model of CCC has reduced the rest myocardial perfusion defects, supporting the notion that those areas correspond to viable hypoperfused myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction

Background: The benefits of attenuation correction (AC) in technetium-99m myocardial perfusion imaging (MPI) have been well established. However, the value of thallium (Tl-201) AC and routine computed tomography AC (CTAC) were less well established. The aims of this study were to evaluate the diagnostic performance of thallium (Tl-201) MPI with additional CTAC and to determine which participants would benefit most. Methods and Results: A total of 108 consecutive patients who underwent Tl-201 MPI and received coronary angiography within 3 months were enrolled. Diagnostic performance was determined by sensitivity, specificity, and receiver operating characteristic curve analysis. Subgroup analyses were performed using gender and obesity. CTAC improved the area under the curve (0.84 vs. 0.77, P = 0.037 at patient level), primarily due to a significant improvement in specificity (0.78 vs. 0.57, P = 0.013) and no significant difference in sensitivity (0.79 vs. 0.82, P = 0.75). In subgroup analysis, CTAC was most helpful in obese subjects, men, and especially right coronary artery lesions. Conclusions: CTAC significantly improved diagnostic performance primarily by increasing the specificity, and the improvements were significantly greater in obese patients and male patients. These findings suggest that CTAC should be applied to Tl-201 MPI as routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analogies and disparities among scintigraphic bone tracers in the diagnosis of cardiac and non-cardiac ATTR amyloidosis

In this issue of JNC, BW Spery and Coll report a retrospective analysis of 57 patients with transthyretin-related amyloidosis (ATTR) in an advanced phase of the disease who underwent 99mTechnetium-pyrophosphate (99mTcPYP) scintigraphy. Although relatively small and “negative,” the study is relevant since it broadens our knowledge on the uptake of “bone tracers” in ATTR and contributes to understand the limitations of the clinical use of scintigraphy in this disease. The paper raises, directly or indirectly, at least three questions: To what extent are the different bone tracers interchangeable for the diagnosis of ATTR cardiac amyloidosis? Are bone tracers able to image non-cardiac ATTR amyloidosis? What is the explanation for the variable performance of the different bone tracers in the diagnosis of cardiac and extracardiac ATTR amyloidosis?.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion

Background: The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Methods and Results: Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of {sup 18}F-fluorodeoxyglucose (FDG) abnormalities were assessed using {sup 99m}Tc-sestamibi and {sup 18}F–FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of {sup 18}F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Conclusions: Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How variable are the volumetric measurements from gated perfusion SPECT when a one-day stress-rest protocol is used?

Background: Using myocardial perfusion scintigraphy (MPS), an increase in left ventricular (LV) volumes or a decrease in ejection fraction (EF) from rest to stress may be clinically important. The variation in these measures between the low-dose stress acquisition and high-dose rest acquisition in a one-day stress-rest protocol has not been established. We assessed the reproducibility of gated volumetric indices between stress and rest and the normal variation in ungated TID ratio for a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol. Methods: Two thousand and one hundred and fifty eight (2158) {sup 99m}Tc-tetrofosmin MPS patient studies were analyzed retrospectively. Studies were excluded for incomplete data, significant technical difficulties, or (for gated analysis but not for analysis of TID ratio) if the LV EF was > 75%. An analysis of gated data was undertaken to establish the reproducibility of ventricular volumes and EF between stress and rest scans. Ungated volume data were analyzed to determine the confidence limits of TID ratio according to ventricular volume. Results: Gated data were analyzed for 621 patients without inducible hypoperfusion. Mean EF at rest was slightly higher than after stress (62.4% ± 10.3% vs 61.2% ± 10.4%, P < 0.001), and the standard deviation of the difference was 5.2% (95% CI 4.9% to 5.5%). Ungated volumes were available for 992 non-ischaemic patients. The upper 95% CI for TID ratio was 1.23. This increased from 1.20 to 1.37 between the highest and lowest deciles of rest ungated volume. Conclusion: Using a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol, a fall in LV EF between rest and stress of > 11.6% or a TID ratio of > 1.23 is likely to be clinically reliable. The upper limit of normal for TID ratio needs to be increased for patients with small LV chamber volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal monitoring adipose-derived stem cell survival by PET imaging hexadecyl-4-{sup 124}I-iodobenzoate in rat myocardial infarction model

Highlights: • We developed a safe, simple and appropriate stem cell labeling method with {sup 124}I-HIB. • ADSC survival can be monitored with PET in MI model via direct labeling. • Tracking of ADSC labeled with {sup 124}I-HIB was possible for 3 days in MI model using PET. • ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. • Survival of ADSC in living bodies can be longitudinally tracked with PET imaging. - Abstract: This study aims to monitor how the change of cell survival of transplanted adipose-derived stem cells (ADSCs) responds to myocardial infarction (MI) via the hexadecyl-4-{sup 124}I-iodobenzoate ({sup 124}I-HIB) mediated direct labeling method in vivo. Stem cells have shown the potential to improve cardiac function after MI. However, monitoring of the fate of transplanted stem cells at target sites is still unclear. Rat ADSCs were labeled with {sup 124}I-HIB, and radiolabeled ADSCs were transplanted into the myocardium of normal and MI model. In the group of {sup 124}I-HIB-labeled ADSC transplantation, in vivo imaging was performed using small-animal positron emission tomography (PET)/computed tomography (CT) for 9 days. Twenty-one days post-transplantation, histopathological analysis and apoptosis assay were performed. ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. In vivo tracking of the {sup 124}I-HIB-labeled ADSCs was possible for 9 and 3 days in normal and MI model, respectively. Apoptosis of transplanted cells increased in the MI model compared than that in normal model. We developed a direct labeling agent, {sup 124}I-HIB, and first tried to longitudinally monitor transplanted stem cell to MI. This approach may provide new insights on the roles of stem cell monitoring in living bodies for stem cell therapy from pre-clinical studies to clinical trials.

60 APPLIED LIFE SCIENCES↗

Lung Dose Calculation With SPECT/CT for {sup 90}Yittrium Radioembolization of Liver Cancer

Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ({sup 99m}Tc-MAA) single photon emission CT (SPECT)/CT for {sup 90}Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of {sup 99m}Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on {sup 99m}Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Models for Regional Hepatic Function Based on 99mTc-IDA SPECT and Local Radiation Dose for Physiologic Adaptive Radiation Therapy

Purpose: High-dose radiation therapy (RT) for intrahepatic cancer is limited by the development of liver injury. This study investigated whether regional hepatic function assessed before and during the course of RT using 99mTc-labeled iminodiacetic acid (IDA) single photon emission computed tomography (SPECT) could predict regional liver function reserve after RT. Methods and Materials: Fourteen patients treated with RT for intrahepatic cancers underwent dynamic 99mTc-IDA SPECT scans before RT, during, and 1 month after completion of RT. Indocyanine green (ICG) tests, a measure of overall liver function, were performed within 1 day of each scan. Three-dimensional volumetric hepatic extraction fraction (HEF) images of the liver were estimated by deconvolution analysis. After coregistration of the CT/SPECT and the treatment planning CT, HEF dose–response functions during and after RT were generated. The volumetric mean of the HEFs in the whole liver was correlated with ICG clearance time. Three models, dose, priori, and adaptive models, were developed using multivariate linear regression to assess whether the regional HEFs measured before and during RT helped predict regional hepatic function after RT. Results: The mean of the volumetric liver HEFs was significantly correlated with ICG clearance half-life time (r=−0.80, P<.0001), for all time points. Linear correlations between local doses and regional HEFs 1 month after RT were significant in 12 patients. In the priori model, regional HEF after RT was predicted by the planned dose and regional HEF assessed before RT (R=0.71, P<.0001). In the adaptive model, regional HEF after RT was predicted by regional HEF reassessed during RT and the remaining planned local dose (R=0.83, P<.0001). Conclusions: 99mTc-IDA SPECT obtained during RT could be used to assess regional hepatic function and helped predict post-RT regional liver function reserve. This could support individualized adaptive radiation treatment strategies to maximize tumor control and minimize the risk of liver damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 4-Dimensional Computed Tomography Ventilation With Nuclear Medicine Ventilation-Perfusion Imaging: A Clinical Validation Study

Purpose: Four-dimensional computed tomography (4DCT) ventilation imaging provides lung function information for lung cancer patients undergoing radiation therapy. Before 4DCT-ventilation can be implemented clinically it needs to be validated against an established imaging modality. The purpose of this work was to compare 4DCT-ventilation to nuclear medicine ventilation, using clinically relevant global metrics and radiologist observations. Methods and Materials: Fifteen lung cancer patients with 16 sets of 4DCT and nuclear medicine ventilation-perfusion (VQ) images were used for the study. The VQ-ventilation images were acquired in planar mode using Tc-99m-labeled diethylenetriamine-pentaacetic acid aerosol inhalation. 4DCT data, spatial registration, and a density-change-based model were used to compute a 4DCT-based ventilation map for each patient. The percent ventilation was calculated in each lung and each lung third for both the 4DCT and VQ-ventilation scans. A nuclear medicine radiologist assessed the VQ and 4DCT scans for the presence of ventilation defects. The VQ and 4DCT-based images were compared using regional percent ventilation and radiologist clinical observations. Results: Individual patient examples demonstrate good qualitative agreement between the 4DCT and VQ-ventilation scans. The correlation coefficients were 0.68 and 0.45, using the percent ventilation in each individual lung and lung third, respectively. Using radiologist-noted presence of ventilation defects and receiver operating characteristic analysis, the sensitivity, specificity, and accuracy of the 4DCT-ventilation were 90%, 64%, and 81%, respectively. Conclusions: The current work compared 4DCT with VQ-based ventilation using clinically relevant global metrics and radiologist observations. We found good agreement between the radiologist's assessment of the 4DCT and VQ-ventilation images as well as the percent ventilation in each lung. The agreement lessened when the data were analyzed on a regional level. Our study presents an important step for the integration of 4DCT-ventilation into thoracic clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Topical Anesthetic Cream on Pain During Periareolar Injection of Technetium Tc99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer: A Randomized Control Trial

Injection of Tc99m to localize nodes for sentinel lymph node biopsy is reported by patients as very painful. The purpose of this study was to determine if anesthetic cream reduces pain associated with periareolar injection of Tc99m and to help elucidate conflicting literature regarding the efficacy of anesthetic cream for this procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Acceptance of Half-dose Vs. Half-time Molecular Breast Imaging

A number of strategies have been implemented at our institution to allow reductions in the administered dose or imaging time for molecular breast imaging (MBI). In this work, we examine patient opinions of whether dose reduction or time reduction is preferred.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A technique using {sup 99m}Tc-mebrofenin SPECT for radiotherapy treatment planning for liver cancers or metastases

Radiotherapy or stereotactic body radiosurgery (SBRT) requires a sufficient functional liver volume to tolerate the treatment. The current study extended the work of de Graaf et al. (2010) [3] on the use of {sup 99m}Tc-mebrofenin imaging for presurgery planning to radiotherapy planning for liver cancer or metastases. Patient was immobilized and imaged in an identical position on a single-photon emission computed tomography/computed tomography (SPECT-CT) system and a radiotherapy simulation CT system. {sup 99m}Tc-mebrofenin SPECT was registered to the planning CT through image registration of noncontrast CT from SPECT-CT system to the radiotherapy planning CT. The voxels with higher uptake of {sup 99m}Tc-mebrofenin were transferred to the planning CT as an avoidance structure in optimizing a 2-arc RapidArc plan for SBRT delivery. Excellent dose coverage to the target and sparing of the healthy remnant liver volume was achieved. This report illustrated a procedure for the use of {sup 99m}Tc-mebrofenin SPECT for optimizing radiotherapy for liver cancers and metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pre-clinical studies of toxin-specific Nanobodies: Evidence of in vivo efficacy to prevent fatal disturbances provoked by scorpion envenoming

Scorpions represent a significant threat to humans and animals in various countries throughout the world. Recently, we introduced Nanobodies (Nbs) to combat more efficiently scorpion envenoming and demonstrated the performance of NbAahIF12 and NbAahII10 to neutralize scorpion toxins of Androctonus australis hector venom. A bispecific Nb construct (NbF12-10) comprising these two Nbs is far more protective than the classic Fab′{sub 2} based therapy and is the most efficient antivenom therapy against scorpion sting in preclinical studies. Now we investigate the biodistribution and pharmacokinetics of {sup 99m}Tc labeled Nbs by in vivo imaging in rodents and compared these data with those of the Fab′{sub 2} product (PAS). The pharmacodynamics of the Nbs was investigated in rats by in vivo echocardiography and it is shown that NbF12-10 prevents effectively the hemodynamic disturbances induced by a lethal dose of venom. Moreover, even a late injection of NbF12-10 restores the heart rate and brings the blood pressure to baseline values. Histology confirms that NbF12-10 prevents lung and heart lesions of treated mice after envenoming. In conjunction, in this preclinical study, we provide proof of concept that NbF12-10 prevents effectively the fatal disturbances induced by Androctonus venom, and that the Nanobody based therapeutic has a potential to substitute the classic Fab′{sub 2} based product as immunotherapeutic in scorpion envenoming. Further clinical study using larger cohorts of animals should be considered to confirm the full protecting potential of our NbF12-10. -- Highlights: ► Nanobody therapy prevents the hemodynamic disturbances induced by a lethal dose. ► Late injection of Nanobody restores hemodynamic parameters to baseline values. ► Nanobody therapy prevents lung and heart lesions of treated mice after envenoming. ► Labeled Nanobody and Fab’2 pharmacokinetics curves reach plateau in favour of Nanobody.

60 APPLIED LIFE SCIENCES↗