Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMISTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Microelectronic components and metallic oxide studies and applications

The project involved work in two basic areas: (1) Evaluation of commercial screen printable thick film conductors, resistors, thermistors and dielectrics as well as alumina substrates used in hybird microelectronics industries. Results of tests made on materials produced by seven companies are presented. (2) Experimental studies on metallic oxides of copper and vanadium, in an effort to determine their electrochemical properties in crystalline, powder mixtures and as screen printable thick films constituted the second phase of the research effort. Oxide investigations were aimed at finding possible applications of these materials as switching devices memory elements and sensors.

Williams, L., Jr.↗

An evaluation of temperature profiles from falling sphere soundings

An evaluation of 30 pairs of high-altitude inflatable falling spheres and independent thermistor soundings with a mean rocket-launch-time separation of 27 min shows average temperature differences within 6 C at 32-70 km, except for an average difference of 10 C at 68 km near Mach 1 in the sphere descent curve. The mean difference is exhibited as a negative bias (sphere temperature colder) for which various explanations are considered. The rms temperature differences are greatest near 50 km (7 C) and 68 km (11 C). From 70 to approximately 87.5 km, confidence in the reliability of the sphere temperature soundings is based on the 'repeatability' of pairs of sphere soundings taken within 20 min, temperature differences generally being less than 10 C. Illustrations of large atmospheric variations measured by the sphere soundings are given along with verification from independent measurements.

Quiroz, R. S.↗

Discrete component bonding and thick film materials study

The bonding reliability of discrete capacitor chips bonded with solders and conductive epoxies was examined along with the thick film resistor materials consisting of iron oxide phosphate and vanadium oxide phosphates. It was concluded from the bonding reliability studies that none of the wide range of types of solders examined is capable of resisting failure during thermal cycling while the conductive epoxy gives substantially lower failure rates. The thick film resistor studies proved the feasibility of iron oxide phosphate resistor systems although some environmental sensitivity problems remain. One of these resistor compositions has inadvertently proven to be a candidate for thermistor applications because of the excellent control achieved upon the temperature coefficient of resistance. One new and potentially damaging phenomenon observed was the degradation of thick film conductors during the course of thermal cycling.

Kinser, D. L.↗

Thin film atomic hydrogen detectors

Thin film and bead thermistor atomic surface recombination hydrogen detectors were investigated both experimentally and theoretically. Devices were constructed on a thin Mylar film substrate. Using suitable Wheatstone bridge techniques sensitivities of 80 microvolts/2x10 to the 13th power atoms/sec are attainable with response time constants on the order of 5 seconds.

Gruber, C. L.↗

Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

Montgomery, L. D.↗

Hybrid temperature-monitoring circuit

Hybrid circuit developed for use in hand-held vital signs monitor converts resistance of thermistor probe to 3 1/2 digit BCD (binary-coded-decimal) temperature readout. If used alone circuit can form 'stand alone' temperature monitor or can transmit temperature data via telemetry to data acquisition systems.

Rinard, G. A.↗

Animal Exposure During Burn Tests

An animal exposure test system (AETS) was designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consisted of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram (ECG) and respiration. Cage temperature is measured by a thermistor located in the upper portion of the rat compartment. Animal activity is monitored by the ECG and the records indicate an increase in EMG (electromyograph) noise super-imposed by the increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases and specific events occurring during the test. The AETS was shown to be a useful tool in screening materials for the relative toxicity of their outgassing products during pyrolysis and combustion.

Gaume, J. G.↗

Summary of system state-of-health measurements STRATCOM 8: A balloon experiment

Various measurements were made to determine the temperature and attitude of the gondola and the status of primary power and control equipment. Bead thermistors were used to measure temperatures at selected points throughout the gondola. A two-axis magnetometer and a two-axis pendulum were used to measure gondola attitude. Voltage and current measurements indicated the status of the primary power sources and associated power converters.

Herrington, P. B.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

A procedure for determining the optical characteristics of a device for measuring illumination in the atmosphere of Venus

A procedure is described for obtaining the calibration, angular and spectral characteristics of a broad band photometer used on Venera 9 and 10 spacecraft to measure the illuminance regime in five spectral intervals with respect to three directions. The photometer has three identical groups of photoreceivers on which light falls through fiber light guides. Each group contains three cadmium sulfide photoresistors with light filters, a cadmium selenide photoresistor and a silicon photodiode. The temperature of the photoreceivers is measured by thermistors installed in series with the receivers.

Golovin, Y. M.↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

Sample stream distortion modeled in continuous-flow electrophoresis

Buoyancy-induced disturbances in an electrophoresis-type chamber were investigated. Five tracer streams (latex) were used to visualize the flows while a nine-thermistor array sensed the temperature field. The internal heating to the chamber was provided by a 400 Hz electrical field. Cooling to the chamber was provided on the front and back faces and, in addition, on both chamber side walls. Disturbances to the symmetric base flow in the chamber occurred in the broad plane of the chamber and resulted from the formation of lateral and axial temperature gradients. The effect of these gradients was to retard or increase local flow velocities at different positions in the chamber cross section, which resulted in lateral secondary flows being induced in the broad plane of the chamber. As the adverse temperature gradients increased in magnitude, the critical Rayleigh number was approached and reverse (separated) flow became apparent, which, subsequently, led to the onset of time variant secondary flows.

Rhodes, P. H.↗

A 94/183 GHz aircraft radiometer system for Project Storm Fury

A radiometer design suitable for use in NASA's WB-57F aircraft to collect data from severe storm regions was developed. The design recommended was a 94/183 GHz scanning radiometer with 3 IF channels on either side of the 183.3 GHz water vapor line and a single IF channel for a low loss atmospheric window channel at 94 GHz. The development and construction of the 94/183 GHz scanning radiometer known as the Advanced Microwave Moisture Sounder (AMMS) is presented. The radiometer scans the scene below the aircraft over an angle of + or - 45 degrees with the beamwidth of the scene viewed of approximately 2 degrees at 94 GHz and 1 degree at 183 GHz. The AMMS data collection system consists of a microcomputer used to store the radiometer data on the flight cartridge recorder, operate the stepper motor driven scanner, and collect housekeeping data such as thermistor temperature readings and aircraft time code.

Gagliano, J. A.↗

Effect of rawinsonde errors on rocketsonde density and pressure profiles: An error analysis of the Rawinsonde System

An initial value of pressure is required to derive the density and pressure profiles of the rocketborne rocketsonde sensor. This tie-on pressure value is obtained from the nearest rawinsonde launch at an altitude where overlapping rawinsonde and rocketsonde measurements occur. An error analysis was performed of the error sources in these sensors that contribute to the error in the tie-on pressure. It was determined that significant tie-on pressure errors result from radiation errors in the rawinsonde rod thermistor, and temperature calibration bias errors. To minimize the effect of these errors radiation corrections should be made to the rawinsonde temperature and the tie-on altitude should be chosen at the lowest altitude of overlapping data. Under these conditions the tie-on error, and consequently the resulting error in the Datasonde pressure and density profiles is less tha 1%. The effect of rawinsonde pressure and temperature errors on the wind and temperature versus height profiles of the rawinsonde was also determined.

Luers, J. K.↗

Solar Heating System installed at Belz Investment Company, Memphis, Tennessee

A hot air solar system which utilizes flat plate air collectors is discussed. Collector areas for each of four buildings cover 780 sq ft, with storage capacity of 390 cu ft per building. The air system has a special air handling unit to move air through the collectors and into and out of the rock storage, with connection to the air duct distribution system. The heat of the motor is added to the heat delivered to the system. The solar system also includes four motorized special low leakage dampers and two gravity fabric dampers. The system is automatically controlled by a solid state controller with three thermistors: one located in the collectors, one in the rock box to plenum, one in the return air duct from the heated space. A three stage heating thermostat, located in the conditioned space, controls the operation.

Source record↗

Effects of gravitational profiles on the rat's thermoregulatory response to cold

Unrestrained rats were subjected to a 1-h period of cold exposure during centrifugation to characterize their ability to regulate core temperature T(c) and to determine if this regulation was dependent on the amplitude of the hypergravic field before the cold exposure. T(c) was measured in unrestrained rats by the use of a thermistor implanted adjacent to the carotid artery. One hour of cold exposure applied over the last hour of either a 1-, 4-, 7-, 13-, 19-, 25-, or 37-h period at 3 G evoked a decrease in T(c) of about 3 C. This fall in T(c) was significantly greater than changes in T(c) in cold-exposed rats at 1 G. No significant differences were found between the measured decreases in T(c) observed for the 1-h cold exposures during the first 37 h at 3 G. However, when rats were subjected concurrently to cold and acceleration after eight days at 3 G, they exhibited a smaller fall in T(c) suggesting a partial recovery of the acceleration-induced impairment of temperature regulation. In another series of experiments, the gravitational field profile was changed in amplitude in three different ways during the 3-h period preceding the 1-h cold exposure at 3 G. Despite the different gravitational field profiles before cold, the magnitude of the fall in T(c) over the 1-h period of cold exposure was the same in all cases. These results suggest that the thermoregulatory impairment has a rapid onset, is a manifestation of an ongoing effect of hypergravity, and is not dependent on the prior G profile. The inability of rats to maintain T(c) when cold exposed may be transient as indicated by the partial recovery of regulation by the eighth day.

Schertel, E. R.↗

Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

Lund, G. F.↗

Atmospheric density, temperature and wind measurement techniques during the 1980 Energy Budget Campaign

Super Loki rocketsonde systems are described. The datasonde telemeters data to a ground station where ambient temperatures are calculated between 20 and 70 km. The sphere is a passive, radar tracked system which allows density to be calculated between 30 and 90 km. When flown simultaneously the systems give redundant data in the altitudes between 30 and 70 km. The datasonde has a balloon parachute that descends more slowly than a conventional parachute and is more stable. Because of launch constraints the datasondes reached very high apogees, leading to very fast descent velocities. Aerodynamic heating reduced thermistor sensitivity. Anomalous parachute behavior influenced wind sensing until a denser layer was reached. The spheres collapsed above 60 km altitude, but their data, combined with dropsonde data give significant results for 21 flights. These show that the stratosphere is colder than Cospar 72 model predictions and the mesosphere is warmer.

Schmidlin, F. J.↗