Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of thermoelectric inhomogeneity of thermocouples

In a thermocouple probe that has significantly inhomogeneous legs, the relationship between emf and temperature is indefinite and depends on temperature distribution along the circuit. An inhomogeneous thermocouple cannot be calibrated to arbitrarily small uncertainty. Therefore, testing for inhomogeneities is a necessary preliminary to meaningful calibration. As most significant inhomogeneity that does occur is introduced during use (and sometimes during calibration) a post-test inhomogeneity measurement should also be employed to detect degradation that might have substantially affected the data. This paper presents a practical test method that is being developed for the observation, interpretation, and application of thermoelectric inhomogeneity as a routine quality assurance measurement that is an essential complement to traditional sheathed thermocouple calibration.

Reed, R. P.↗

Apparatus Tests Thermocouples For Seebeck Inhomogeneity

Automated apparatus reveals sources of error not revealed in calibration. Computer-controlled apparatus detects and measures Seebeck inhomogeneities in sheathed thermocouples. Measures thermocouple output voltage as function of position of probe along sharp gradient of temperature. Abnormal variations in voltage-versus-position data indicative of Seebeck inhomogeneities. Prototype for development of standard method and equipment for routine acceptance/rejection testing of sheathed thermocouples in industrial and research laboratories.

Burkett, Cecil G., Jr.↗

Application of Thin-Film Thermocouples to Localized Heat Transfer Measurements

The paper describes a proof-of-concept experiment on thin-film thermocouples used for localized heat transfer measurements applicable to experiments on hot parts of turbine engines. The paper has three main parts. The first part describes the thin-film sensors and manufacturing procedures. Attention is paid to connections between thin-film thermocouples and lead wires, which has been a source of problems in the past. The second part addresses the test arrangement and facility used for the heat transfer measurements modeling the conditions for upcoming warm turbine tests at NASA LeRC. The paper stresses the advantages of a modular approach to the test rig design. Finally, we present the results of bulk and local heat flow rate measurements, as well as overall heat transfer coefficients obtained from measurements in a narrow passage with an aspect ratio of 11.8. The comparison of bulk and local heat flow rates confirms applicability of thin-film thermocouples to upcoming warm turbine tests.

Lepicovsky, J.↗

Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

Lerch, B. A.↗

Comparisons of Gas-phase Temperature Measurements in a Flame Using Thin-Filament Pyrometry and Thermocouples

Less-intrusive, fast-responding, and full-field temperature measurements have long been a desired tool for the research community. Recently, the emission of a silicon-carbide (SiC) fiber placed in a flowing hot (or reacting) gas has been used to measure the temperature profile along the length of the fiber. The relationship between the gas and fiber temperature comes from an energy balance on the fiber. In the present work, we compared single point flame temperature measurements using thin-filament pyrometry (TFP) and thermocouples. The data was from vertically traversing a thermocouple and a SiC fiber through a methanol/air diffusion flame of a porous-metal wick burner. The results showed that the gas temperature using the TFP technique agreed with the thermocouple measurements (25.4 m diameter wire) within 3.5% for temperatures above 1200 K. Additionally, we imaged the entire SiC fiber (with a spatial resolution of 0.14 mm) while it was in the flame using a high resolution CCD camera. The intensity level along the fiber length is a function of the temperature. This results in a one-dimensional temperature profiles at various heights above the burner wick. This temperature measurement technique, while having a precision of less than 1 K, showed data scatter as high as 38 K. Finally, we discuss the major sources of uncertainty in gas temperature measurement using TFP.

Struk, Peter↗

Development of Thin Film Ceramic Thermocouples for High Temperature Environments

The maximum use temperature of noble metal thin film thermocouples of 1100 C (2000 F) may not be adequate for use on components in the increasingly harsh conditions of advanced aircraft and next generation launch technology. Ceramic-based thermocouples are known for their high stability and robustness at temperatures exceeding 1500 C, but are typically found in the form of rods or probes. NASA Glenn Research Center is investigating the feasibility of ceramics as thin film thermocouples for extremely high temperature applications to take advantage of the stability and robustness of ceramics and the non-intrusiveness of thin films. This paper will discuss the current state of development in this effort.

Wrbanek, John D.↗

Thin-Film Thermocouple Technology Demonstrated for Reliable Heat Transfer Measurements

Exploratory work is in progress to apply thin-film thermocouples to localized heat transfer measurements on turbine engine vanes and blades. The emerging thin-film thermocouple technology shows great potential to improve the accuracy of local heat transfer measurements. To verify and master the experimental methodology of thin-film thermocouples, the NASA Lewis Research Center conducted a proof-of-concept experiment in a controlled environment before applying the thin-film sensors to turbine tests.

Source record↗

Thermal Conductivity Estimation from Transient Test Data with Embedded Thermocouples using Genetic Algorithm Optimization

Inverse heat transfer methodology previously developed to estimate thermal properties of high temperature fibrous insulation from embedded thermocouples was applied to the thermoplastic polymer, polyether-ether-ketone (PEEK). A small experimental setup was utilized to test the PEEK sample between temperatures of 300 K and 525 K at atmospheric pressure. Cylindrical plugs of PEEK with three thermocouples embedded at various depths were incorporated in the test sample. The experimental PEEK thermocouple data were used as the boundary and initial conditions of a one-dimensional numerical thermal model to predict the internal temperatures of the material. The thermal conductivity of PEEK was estimated with the Continuous Genetic Algorithm optimization technique by searching for the coefficients of a functional form of thermal conductivity that minimized the difference between the experimentally measured and model predicted internal temperature values. The thermal testing, one-dimensional numerical thermal model, optimization algorithm, analysis, and results are presented.

Thermal Properties↗

High-temperature thermocouples and related methods

A high-temperature thermocouple and methods for fabricating a thermocouple capable of long-term operation in high-temperature, hostile environments without significant signal degradation or shortened thermocouple lifetime due to heat induced brittleness.

42 ENGINEERING↗

Multi-core high-temperature, irradiation-resistant thermocouple, and related methods

A multi-core thermocouple includes a plurality of wires, an insulation core surrounding the plurality of wires, a sheath surrounding the insulation core, and a plurality of electrical junctions. The plurality of electrical junctions may include a first electrical junction formed between a first wire of the plurality of wires and the sheath at a first axial mid-section of the multi-core thermocouple, the first electrical junction including a first swaged axial mid-section of the sheath and a second electrical junction formed between a second wire of the plurality of wires and the sheath at a second, different axial mid-section of the multi-core thermocouple, the second electrical junction including a second swaged axial mid-section of the sheath.

Skifton, Richard S.↗

Anodic vacuum arc developed nanocrystalline Cu-Ni and Fe-Ni thin film thermocouples

This paper deals with the development of nanocrystalline Cu-Ni and Fe-Ni thin film thermocouples (TFTCs) by using ion-assisted anodic vacuum arc deposition technique. The crystallographic structure and surface morphology of individual layer films have been studied by x-ray diffraction and scanning electron microscopy, respectively. The resistivity, temperature coefficient of resistance, and thermoelectric power of as deposited and annealed films have been measured. The observed departure of these transport parameters from their respective bulk values can be understood in terms of intrinsic scattering due to enhanced crystallite boundaries. From the measured values of thermoelectric power and the corresponding temperature coefficient of resistance of annealed Cu, Ni, and Fe films, the calculated values of log derivative of the mean free path of conduction electrons at the Fermi surface with respect to energy (U) are found to be -0.51, 3.22, and -8.39, respectively. The thermoelectric response of annealed Cu-Ni and Fe-Ni TFTCs has been studied up to a maximum temperature difference of 300 deg. C. Reproducibility of TFTCs has been examined in terms of the standard deviation in thermoelectric response of 16 test samples for each pair. Cu-Ni and Fe-Ni TFTCs agree well with their wire thermocouple equivalents. The thermoelectric power values of Cu-Ni and Fe-Ni TFTCs at 300 deg. C are found to be 0.0178 and 0.0279 mV/ deg. C, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak

A novel set of thermocouple sensors has been developed to measure heat fluxes arriving at divertor surfaces in the Alcator C-Mod tokamak, a magnetic confinement fusion experiment. These sensors operate in direct contact with the divertor plasma, which deposits heat fluxes in excess of {approx}10 MW/m{sup 2} over an {approx}1 s pulse. Thermoelectric EMF signals are produced across a non-standard bimetallic junction: a 50 {mu}m thick 74% tungsten-26% rhenium ribbon embedded in a 6.35 mm diameter molybdenum cylinder. The unique coaxial geometry of the sensor combined with its single-point electrical ground contact minimizes interference from the plasma/magnetic environment. Incident heat fluxes are inferred from surface temperature evolution via a 1D thermal heat transport model. For an incident heat flux of 10 MW/m{sup 2}, surface temperatures rise {approx}1000 deg. C/s, corresponding to a heat flux flowing along the local magnetic field of {approx}200 MW/m{sup 2}. Separate calorimeter sensors are used to independently confirm the derived heat fluxes by comparing total energies deposited during a plasma pulse. Langmuir probes in close proximity to the surface thermocouples are used to test plasma-sheath heat transmission theory and to identify potential sources of discrepancies among physical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature blackbody BB2000/40 for calibration of radiation thermometers and thermocouple

The cavity-type high temperature blackbody (HTBB) models of BB3200/3500 series are the most spread among metrological institutes worldwide as sources for radiometry and radiation thermometry, due to their ultra high working temperatures, high emissivity and stability. The materials of radiating cavities are graphite, pyrolytic graphite (PG) and their combination. The paper describes BB2000/40 blackbody with graphite-tube cavity that was developed for calibration of radiation thermometers at SCEI (Singapore). The peculiarity of BB2000/40 is a possibility to use it, besides calibration of pyrometers, as an instrument for thermocouples calibration. Operating within the temperature range from 900 °C to 2000 °C, the blackbody has a wide cavity opening of 40 mm. Emissivity of the cavity, with PG heater rings replaced partly by graphite elements, was estimated as 0.998 ± 0.0015 in the spectral range from 350 nm to 2000 nm. The uniformity along the cavity axis, accounting for 10 °C, was measured using a B-type thermocouple at 1500 °C. The BB2000/40, if necessary, can be easily modified, by replacing the graphite radiator with a set of PG rings, to be able to reach temperatures as high as 3200 °C. The HTBB utilizes an optical feedback system which allows temperature stabilization within 0.1 °C. This rear-view feedback allows the whole HTBB aperture to be used for measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the fissile bead's and thermocouple wires’ sizes on the response time of a fission couple

The fission couple is proposed as a fast response miniature neutron detector in the measurement of time dependent energy depositions within the fissile material based on theoretical analysis, but the response time of a fission couple is relatively slow in practice. The time lag originated from heat transfer process was demonstrated to be the dominating factor by theoretical simulations and experimental verification in this paper. The response of a fission couple as a function of the bead size and the thermocouple wires’ sizes are simulated using ANSYS workbench. The decrease of wires’ diameter results in the decrease of response time, and the increase of bead's diameter leads to a slight increase of response time. During a pulse heating transient in the fuel of Chinese Fast Burst Reactor II with a FWHM of 181μs, the time lag originated from heat transfer process is about tens of microseconds for the peaks of the change rate of temperature, and is of the order of milliseconds to achieve 85% of the temperature rise for a typical fission couple with a Φ 1 mm fissile bead and two Φ 0.05 mm thermocouple wires. The results obtained provide foundation for the optimization of fission couples.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extension Wire for High Temperature Irradiation Resistant Thermocouples

In an effort to reduce production costs for the doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs) recently developed by the Idaho National Laboratory (INL), a series of evaluations were completed to identify an optimum compensating extension cable. Results indicate that of those combinations tested, two inexpensive, commercially-available copper nickel alloy wires approximate the low temperature (0 to 500oC) thermoelectric output of KW-Mo versus Nb-1%Zr in HTIR-TCs. For lower temperatures (0 to 150oC), which is the region where soft extension cable is most often used, results indicate that the thermocouple emf is best replicated by the Cu-3.5%Ni versus Cu-5%Ni combination (measured emfs were within 4% at 100 and 150oC). At higher temperatures (300 to 500oC), data suggest that the Cu-5%Ni versus Cu-10%Ni combination may yield data closer to that obtained with KW-Mo versus Nb-1%Zr wires (measured emfs were within 8%). Further, interpolation of test results suggest that a combination containing a negative thermoelement with slightly lower nickel content, such as Cu-5%Ni versus Cu-9%Ni, may yield more representative data if extension cable is needed for these higher temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mounting a thermocouple of type E onto a Cu single crystal for use in a magnetically sensitive environment below 77 K

Type E thermocouples show magnetic effects at liquid nitrogen temperature and below. This may cause trouble in experiments that are sensitive to magnetic stray fields like nuclear magnetic resonance, photoemission or high resolution electron energy loss spectroscopy. Here, a solution for the temperature measurement of a single crystal is presented. The authors weld a copper rod onto the back side of the single crystal, thereby relocating the sensitive sample from the thermocouple attachment position. They show that it is possible to measure the crystal temperature at the end of the rod while significantly reducing the ferromagnetic influence due to the increased distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AGR-1 Thermocouple Data Analysis

This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of simulation results (Chapter 3). The statistics-based simulation-aided experimental control procedure described for the future AGR tests is developed and demonstrated in Chapter 4. The procedure for controlling the target fuel temperature (capsule peak or average) is based on regression functions of thermocouple readings and other relevant parameters and accounting for possible changes in both physical and thermal conditions and in instrument performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Out-of-pile performance of High Temperature Irradiation Resistant and Cladding Thermocouples

The High Temperature Irradiation Resistant thermocouple (HTIR-TCs) has proven to be the nuclear temperature sensor. It outlast and outperforms all other commercially available thermocouples above 1100 °C inside reactor pressure vessels; also, recent calibration methods have pushed the HTIR-TC to accurately read temperatures through thermal transients during reactor shutdowns and restarts. The new temperature range of HTIR-TCs is from 0 °C to 1650 °C. The main objective of this study is to address manufacturing a more robust TC for handling and inserting into reactor experiments; to also apply the TC to a wider application. The TC has shown to be mainly susceptible to oxygen levels inside the heat treatment and calibration process and it is recommended that O2 levels be brought to as low as possible. However, through modeling efforts the O2 has been found to intercalate only within the first few layers of niobium on the outer sheath. Lastly, multiple materials were used for the sheath and insulators; all with similar outcomes when testing occurred over a long period of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗