Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Applying Space Technology to Enhance Control of an Artificial Arm

At the present time, myoelectric prostheses perform only one function of the hand: open and close with the thumb, index and middle finger coming together to grasp various shaped objects. To better understand the limitations of the current single-function prostheses and the needs of the individuals who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (August 1992 - November 1994), surveyed approximately 2500 individuals with upper limb loss. When asked to identify specific features of their current electric prosthesis that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement as well as poor control capability. Simply building a mechanism with individual finger and wrist motion is not enough. Individuals with upper limb loss tend to reject prostheses that require continuous visual monitoring and concentration to control. Robotics researchers at NASA's Johnson Space Center (JSC) and Rice University have made substantial progress in myoelectric teleoperation. A myoelectric teleoperation system translates signals generated by an able-bodied robot operator's muscles during hand motions into commands that drive a robot's hand through identical motions. Farry's early work in myoelectric teleoperation used variations over time in the myoelectric spectrum as inputs to neural networks to discriminate grasp types and thumb motions. The resulting schemes yielded up to 93% correct classification on thumb motions. More recently, Fernandez achieved 100% correct non-realtime classification of thumb abduction, extension, and flexion on the same myoelectric data. Fernandez used genetic programming to develop functions that discriminate between thumb motions using myoelectric signal parameters. Genetic programming (GP) is an evolutionary programming method where the computer can modify the discriminating functions' form to improve its performance, not just adjust numerical coefficients or weights. Although the function development may require much computational time and many training cases, the resulting discrimination functions can run in realtime on modest computers. These results suggest that myoelectric signals might be a feasible teleoperation medium, allowing an operator to use his or her own hand and arm as a master to intuitively control an anthropomorphic robot in a remote location such as outer space.

Atkins, Diane↗

A new measurement of the cosmic ray electron spectrum from 10 GeV to 300 GeV

The spectrum of cosmic-ray electrons has been measured with an instrument that combines a transition-radiation detector with a shower detector. The transition-radiation detector provides unique identification of individual electrons and good discrimination against protons. At the same time, it allows the construction of a large-area instrument (0.48 sq m ? ster) and consequently makes possible a measurement of improved statistical accuracy. The instrument has been calibrated with electron beams of 5-300 GeV at Fermilab, thus eliminating energy-dependent biases. A first balloon flight yielded 30 hours of data at an altitude of 5 g/sq cm. The design of the instrument is described, along with the accelerator calibrations and the analysis of the balloon flight data. The spectrum of electrons is found to be significantly steeper than that of protons over the whole energy range.

Hartmann, G.↗

Fast scintillation counter preamplifier for the observation of Linsley effect

A fast preamplifier circuit has been designed and thoroughly tested for the purpose of observing the air shower arrival directions including the Linsley effect. The circuit intends to eliminate the time jitter due to variation of scintillation counter signal amplitudes. It assumes that the output signals from one counter system have the same rise time. On this basis, error arising from time jitter is removed by voltage discrimination at about half signal amplitudes. Detailed description of the circuit is reported.

Ng, L. K.↗

Repetition blindness has a perceptual locus: evidence from online processing of targets in RSVP streams

Four experiments tested whether repetition blindness (RB; reduced accuracy reporting repetitions of briefly displayed items) is a perceptual or a memory-recall phenomenon. RB was measured in rapid serial visual presentation (RSVP) streams, with the task altered to reduce memory demands. In Experiment 1 only the number of targets (1 vs. 2) was reported, eliminating the need to remember target identities. Experiment 2 segregated repeated and nonrepeated targets into separate blocks to reduce bias against repeated targets. Experiments 3 and 4 required immediate "online" buttonpress responses to targets as they occurred. All 4 experiments showed very strong RB. Furthermore, the online response data showed clearly that the 2nd of the repeated targets is the one missed. The present results show that in the RSVP paradigm, RB occurs online during initial stimulus encoding and decision making. The authors argue that RB is indeed a perceptual phenomenon.

Form Perception↗

Anatomic patterning in the expression of vestibulosympathetic reflexes

To investigate the possibility that expression of vestibulosympathetic reflexes (VSR) is related to a nerve's anatomic location rather than its target organ, we compared VSR recorded from the same type of postganglionic fiber [muscle vasoconstrictor (MVC)] located at three different rostrocaudal levels: hindlimb, forelimb, and face. Experiments were performed on chloralose-anesthetized cats, and vestibular afferents were stimulated electrically. Single MVC unit activity was extracted by spike shape analysis of few-fiber recordings, and unit discrimination was confirmed by autocorrelation. Poststimulus time histogram analysis revealed that about half of the neurons were initially inhibited by vestibular stimulation (type 1 response), whereas the other MVC fibers were initially strongly excited (type 2 response). MVC units with types 1 and 2 responses were present in the same nerve fascicle. Barosensitivity was equivalent in the two groups, but fibers showing type 1 responses fired significantly faster than those giving type 2 responses (0.29 +/- 0.04 vs. 0.20 +/- 0.02 Hz). Nerve fibers with type 1 responses were most common in the hindlimb (21 of 29 units) and least common in the face (2 of 11 units), the difference in relative proportion being significant (P < 0.05, chi(2) test). These results support the hypothesis that VSR are anatomically patterned.

Non-NASA Center↗

Close binding of identity and location in visual feature perception

The binding of identity and location information in disjunctive feature search was studied. Ss searched a heterogeneous display for a color or a form target, and reported both target identity and location. To avoid better than chance guessing of target identity (by choosing the target less likely to have been seen), the difficulty of the two targets was equalized adaptively; a mathematical model was used to quantify residual effects. A spatial layout was used that minimized postperceptual errors in reporting location. Results showed strong binding of identity and location perception. After correction for guessing, no perception of identity without location was found. A weak trend was found for accurate perception of target location without identity. We propose that activated features generate attention-calling "interrupt" signals, specifying only location; attention then retrieves the properties at that location.

Orientation↗

THEMIS and Substorm Timing

The THEMIS mission represents the culmination of many years of planning directed towards understanding the processes that drive and trigger geomagnetic substorms. Following Akasofu's discovery of the substorm cycle, it became increasingly clear that timing questions provide the key to discriminating between proposed 'inside-out' and 'outside-in' models for substorms, triggered respectively by current disruption and magnetic reconnection. THEMIS observations provide a wealth of information that is currently being investigated to resolve this question. While observations in the magnetotail generally point towards reconnection. those on the ground point towards current disruption. This talk reviews the relevant observations and recent efforts at reconciliation.

Sibeck, D. G.↗

SoLAr: Solar Neutrinos in Liquid Argon

SoLAr is a new concept for a liquid-argon neutrino detector technology to extend the sensitivities of these devices to the MeV energy range - expanding the physics reach of these next-generation detectors to include solar neutrinos. We propose this novel concept to significantly improve the precision on solar neutrino mixing parameters and to observe the "hep branch" of the proton-proton fusion chain. The SoLAr detector will achieve flavour-tagging of solar neutrinos in liquid argon. The SoLAr technology will be based on the concept of monolithic light-charge pixel-based readout which addresses the main requirements for such a detector: a low energy threshold with excellent energy resolution (approximately 7%) and background rejection through pulse-shape discrimination. The SoLAr concept is also timely as a possible technology choice for the DUNE "Module of Opportunity", which could serve as a next-generation multi-purpose observatory for neutrinos from the MeV to the GeV range. The goal of SoLAr is to observe solar neutrinos in a 10 ton-scale detector and to demonstrate that the required background suppression and energy resolution can be achieved. SoLAr will pave the way for a precise measurement of the 8-B flux, an improved precision on solar neutrino mixing parameters, and ultimately lead to the first observation of hep neutrinos in the DUNE Module of Opportunity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

The evaluation of display symbology - A chronometric study of visual search

Three single-target visual search tasks were used to evaluate a set of CRT symbols for a helicopter traffic display. The search tasks were representative of the kinds of information extraction required in practice, and reaction time was used to measure the efficiency with which symbols could be located and identified. The results show that familiar numeric symbols were responded to more quickly than graphic symbols. The addition of modifier symbols such as a nearby flashing dot or surrounding square had a greater disruptive effect on the graphic symbols than the alphanumeric characters. The results suggest that a symbol set is like a list that must be learned. Factors that affect the time to respond to items in a list, such as familiarity and visual discriminability, and the division of list items into categories, also affect the time to identify symbols.

Remington, R.↗

An automated land-use mapping comparison of the Bayesian maximum likelihood and linear discriminant analysis algorithms

The Bayesian maximum likelihood parametric classifier has been tested against the data-based formulation designated 'linear discrimination analysis', using the 'GLIKE' decision and "CLASSIFY' classification algorithms in the Landsat Mapping System. Identical supervised training sets, USGS land use/land cover classes, and various combinations of Landsat image and ancilliary geodata variables, were used to compare the algorithms' thematic mapping accuracy on a single-date summer subscene, with a cellularized USGS land use map of the same time frame furnishing the ground truth reference. CLASSIFY, which accepts a priori class probabilities, is found to be more accurate than GLIKE, which assumes equal class occurrences, for all three mapping variable sets and both levels of detail. These results may be generalized to direct accuracy, time, cost, and flexibility advantages of linear discriminant analysis over Bayesian methods.

Tom, C. H.↗

Methods for segment wheat area estimation

The major research conducted during the three years of LACIE to solve problems associated with segment wheat area estimation is reviewed. Topics covered include proportion estimation, clustering, feature extraction, and signature extension. It would appear that LANDSAT-1 and LANDSAT-2 data do not contain enough information to discriminate between crop types perfectly all the time and, therefore, a basic problem arises when no ground truth data on crop types in the area are available. New approaches are needed to reduce labeling error. Perhaps better use of multiyear LANDSAT data, a more detailed understanding of the cropping practices in the area, better crop calendar prediction, and a better understanding of the limiting sources of error in LANDSAT data related to crop discrimination may provide the insight required to develop improved designs.

Heydorn, R. P.↗

Microbiome response in an urban river system is dominated by seasonality over wastewater treatment upgrades

Background: Microorganisms such as coliform-forming bacteria are commonly used to assess freshwater quality for drinking and recreational use. However, such organisms do not exist in isolation; they exist within the context of dynamic, interactive microbial communities which vary through space and time. Elucidating spatiotemporal microbial dynamics is imperative for discriminating robust community changes from ephemeral ecological trends, and for improving our overall understanding of the relationship between microbial communities and ecosystem health. We conducted a seven-year (2013–2019) microbial time-series investigation in the Chicago Area Waterways (CAWS): an urban river system which, in 2016, experienced substantial upgrades to disinfection processes at two wastewater reclamation plants (WRPs) that discharge into the CAWS and improved stormwater capture, to improve river water quality and reduce flooding. Using culture-independent and culture-dependent approaches, we compared CAWS microbial ecology before and after the intervention. Results: Examinations of time-resolved beta distances between WRP-adjacent sites showed that community similarity measures were often consistent with the spatial orientation of site locations to one another and to the WRP outfalls. Fecal coliform results suggested that upgrades reduced coliform-associated bacteria in the effluent and the downstream river community. However, examinations of whole community changes through time suggest that the upgrades did little to affect overall riverine community dynamics, which instead were overwhelmingly driven by yearly patterns consistent with seasonality. Conclusions: This study presents a systematic effort to combine 16S rRNA gene amplicon sequencing with traditional culture-based methods to evaluate the influence of treatment innovations and systems upgrades on the microbiome of the Chicago Area Waterway System, representing the longest and most comprehensive characterization of the microbiome of an urban waterway yet attempted. We found that the systems upgrades were successful in improving specific water quality measures immediately downstream of wastewater outflows. Additionally, we found that the implementation of the water quality improvement measures to the river system did not disrupt the overall dynamics of the downstream microbial community, which remained heavily influenced by seasonal trends. Such results emphasize the dynamic nature of microbiomes in open environmental systems such as the CAWS, but also suggest that the seasonal oscillations remain consistent even when perturbed.

16S rRNA gene sequencing↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗