At least 127 records · Page 7

An electrochemical study of the corrosion behavior of primer coated 2219-T87 aluminum

The corrosion behavior for 2219-T87 aluminum coated with various primers, including those used for the external tank and solid rocket boosters of the Space Shuttle Transportation System, were investigated using electrochemical techniques. Corrosion potential time, polarization resistance time, electrical resistance time, and corrosion rate time measurements were all investigated. It was found that electrical resistance time and corrosion rate time measurement were most useful for studying the corrosion behavior of painted aluminum. Electrical resistance time determination give useful information concerning the porosity of paint films, while corrosion rate time curves give important information concerning overall corrosion rates and corrosion mechanisms. In general, the corrosion rate time curves all exhibited at least one peak during the 30 day test period, which was attributed, according to the proposed mechanisms, to the onset of the hydrogen evolution reaction and the beginning of destruction of the protective properties of the paint film.

Danford, M. D.↗

Airborne time-series measurement of soil moisture using terrestrial gamma radiation

Terrestrial gamma radiation data and independent ground-based core soil moisture data are analyzed. They reveal the possibility of using natural terrestrial gamma radiation collected from a low-flying aircraft to make reliable real-time soil moisture measurements for the upper 20 cm of soil. The airborne data were compared to the crude ground-based soil moisture data set collected at the core sites.

Carroll, Thomas R.↗

Dynamics of CMEs in the LASCO Field of View

A large set (16000) of coronal mass ejections (CMEs) observed during 1996-2011 was selected to study their dynamics in the LASCO field of view (LFOV). These events were selected based on the criterion that at least three height-time measurements were available for each CME. The height-time measurements included in the SOHO/LASCO catalog were used to determine velocities and accelerations of the respective CMEs at successive distances from the Sun. Next, these parameters were sorted into 30 subsamples depending on the distance from the Sun at which they were determined. The mean velocities and accelerations calculated for the successive distance-dependent subsamples of CMEs were used to study their dynamics. We demonstrate that CMEs in the LFOV manifest three distinct phases of propagation: (i) The propelling Lorentz force dominates the dynamics of CMEs in the inner (C2 LASCO) FOV, (ii) a stable propagation occurs as a result of the balance between the propelling and drag forces, (iii) the drag force dominates at the outer edge of the LFOV. When we considered different categories of CME separately, we found different acceleration distance profiles for different categories.

Michalek, G.↗

Time-Average Molecular Rayleigh Scattering Technique for Measurement of Velocity, Denisty, Temperature, and Turbulence Intensity in High Speed Nozzle Flows

A molecular Rayleigh scattering based flow diagnostic is developed to measure time average velocity, density, temperature, and turbulence intensity in a 25.4-mm diameter nozzle free jet facility. The spectrum of the Rayleigh scattered light is analyzed using a Fabry-Perot interferometer operated in the static imaging mode. The resulting fringe pattern containing spectral information of the scattered light is recorded using a low noise CCD camera. Nonlinear least squares analysis of the fringe pattern using a kinetic theory model of the Rayleigh scattered light provides estimates of density, velocity, temperature, and turbulence intensity of the gas flow. Resulting flow parameter estimates are presented for an axial scan of subsonic flow at Mach 0.95 for comparison with previously acquired pitot tube data, and axial scans of supersonic flow in an underexpanded screeching jet. The issues related to obtaining accurate turbulence intensity measurements using this technique are discussed.

Mielke, Amy F.↗

Evidence for Dark Energy from the Cosmic Microwave Background Alone Using the Atacama Cosmology Telescope Lensing Measurements

For the first time, measurements of the cosmic microwave background radiation (CMB) alone favor cosmologies with w = -1 dark energy over models without dark energy at a 3.2-sigma level. We demonstrate this by combining the CMB lensing deflection power spectrum from the Atacama Cosmology Telescope with temperature and polarization power spectra from the "Wilkinson Microwave Anisotropy Probe. The lensing data break the geometric degeneracy of different cosmological models with similar CMB temperature power spectra. Our CMB-only measurement of the dark energy density Omega(delta) confirms other measurements from supernovae, galaxy clusters and baryon acoustic oscillations, and demonstrates the power of CMB lensing as a new cosmological tool.

Sherwin, Blake D.↗

Long Duration Exposure Facility (LDEF) attitude measurements of the interplanetary dust experiment

The Long Duration Exposure Facility (LDEF) Interplanetary Dust Experiment (IDE) was unique in providing a time history of impacts of micron-sized particles on six orthogonal faces of LDEF during the first year in orbit. The value of this time resolved data depended on and was enhanced by the proper operation of some basic LDEF systems. Thus, the value of the data is greatly enhanced when the location and orientation of LDEF is known for each time of impact. The location and velocity of LDEF as a function of time can be calculated from the 'two-line elements' published by GSFC during the first year of the LDEF mission. The attitude of LDEF was passively stabilized in a gravity-gradient mode and a magnetically anchored viscous damper was used to dissipate roll, pitch, and yaw motions. Finally, the IDE used a standard LDEF Experiment Power and Data System (EPDS) to collect and store data and also to provide a crystal derived clock pulse (1 count every 13.1072 seconds) for all IDE time measurements. All that remained for the IDE was to provide a system to calibrate the clock, eliminating accumulative errors, and also verify the attitude of LDEF. The IDE used solar cells on six orthogonal faces to observe the LDEF sunrise and provide data about the LDEF attitude. The data was recorded by the EPDS about 10 times per day for the first 345 days of the LDEF mission. This data consist of the number of IDE counts since the last LDEF sunrise and the status of the six solar cells (light or dark) at the time of the last IDE count. The EPDS determined the time that data was recorded and includes, with each record, the master EPDS clock counter (1 count every 1.6384 seconds) that provided the range and resolution for time measurements. The IDE solar cells provided data for an excellent clock calibration, meeting their primary purpose, and the time resolved LDEF attitude measurements that can be gleaned from this data are presented.

Kassel, Philip C., Jr.↗

A coated-wire ion-selective electrode for ionic calcium measurements

A coated-wire ion-selective electrode for measuring ionic calcium was developed, in collaboration with Teknektron Sensor Development Corporation (TSDC). This coated wire electrode sensor makes use of advanced, ion-responsive polyvinyl chloride (PVC) membrane technology, whereby the electroactive agent is incorporated into a polymeric film. The technology greatly simplifies conventional ion-selective electrode measurement technology, and is envisioned to be used for real-time measurement of physiological and environment ionic constituents, initially calcium. A primary target biomedical application is the real-time measurement of urinary and blood calcium changes during extended exposure to microgravity, during prolonged hospital or fracture immobilization, and for osteoporosis research. Potential advanced life support applications include monitoring of calcium and other ions, heavy metals, and related parameters in closed-loop water processing and management systems. This technology provides a much simplified ionic calcium measurement capability, suitable for both automated in-vitro, in-vivo, and in-situ measurement applications, which should be of great interest to the medical, scientific, chemical, and space life sciences communities.

Hines, John W.↗

Time-Resolved Measurements Of Laser Far-Field Patterns

Computer-controlled scanning photometric instrumentation system measures intensity pattern in far field of pulsed laser as function of time during each pulse (provided that pulse is at least 1 ns long). Such measurements important in studying dynamics of laser operation: they reveal such previously unobservable phenomena as oscillations of undesired spatial modes of radiation pattern during pulse, steering of beam during pulse, and instability of intensity of laser beam. Principal advantages of system are its relatively low cost and its ability to function under normal lighting conditions without incurring damage.

Forrest, Kathrine↗

U-238-U-234-Th-230-Th-232 systematics and the precise measurement of time over the past 500,000 years

A method is presented for the high-precision measurement of the Th-230 abundance in corals by isotope-dilution mass spectrometry using techniques developed by Chen and Wasserburg (1980, 1981) and Chen et al. (1986). It is shown that 6 x 10 to the 8th atoms of Th-230 can be measured to + or - 30 percent (2 sigma) and 2 x 10 to the 10th atoms of Th-230 to + or - 2 percent. The time over which useful age data on corals can be obtained ranges from a few years to about 500 ky, with the uncertainty in age ranging from 5 y for a 180-y-old coral, to 44 y for a 8294-y-old coral, to 1.1 ky for a 123.1-ky-old coral. Ages were determined with high analytical precision for several corals that grew during high sea-level stands about 120 ky ago, supporting the view that the dominant cause of Pleistocene climate change was Milankovitch forcing.

Edwards, R. Lawrence↗

Growth and characterization of high-performance photorefractive BaTiO3 crystals

Barium titanate has been used for many nonlinear optical applications primarily because it has high grain and high self-pumped phase conjugate reflectivities. However, barium titanate has had a relatively slow response time, and thus low sensitivity. Therefore, it has not been suited to real-time operations. In this report we will describe the modifications in crystal growth, doping, reduction, and poling that have produced barium titanate crystals with the fastest photorefractive response time reported to date, approximately 21 microseconds with a beam-coupling gain coefficient of 38.7 cm(exp -1) and the highest sensitivity reported to date of 3.44 cm(exp 3)/kJ. The sensitivity of these barium titanate crystals is comparable to or greater than other photorefractive oxides. We will show, for the first time, beam-coupling in barium titanate at video frame rates. We infer from response time measurements that barium titanate has a phonon limited mobility. Also, photorefractive response time measurements as a function of the crystallographic orientation and grating wave vector for our cobalt-doped oxygen reduced crystals indicate that their faster response time arise because of an increase in the free carrier lifetime.

Warde, C.↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Time domain measurement of frequency stability: A tutorial introduction

The theoretical basis behind the definition of frequency stability in the time domain is outlined. Various types of variances were examined. Their differences and interrelation are pointed out. Systems that are generally used in the measurement of these variances are described.

Vanier, J.↗

On the measurement of time for the quantum harmonic oscillator

A generalization of previous treatments of quantum phase is presented. Restrictions on the class of realizable phase statistics are thereby removed; thus, permitting 'phase wavefunction collapse' (and other advantages). This is accomplished by exciting the auxiliary mode of the measurement apparatus in a time-reversed fashion. The mathematical properties of this auxiliary mode are studied in the hope that they will lead to an identification of a physical apparatus which can realize the quantum phase measurement.

Shepard, Scott R.↗

Reexamination of data from the asteroid/meteoroid detector

The discovery of the existence of cosmoids, a class of meteoroid in near hyperbolic orbits, was made in a reevaluation of the Sisyphus Experiment on Pioneer 10 and 11. This experiment measured the spontaneous jetting of cosmoids and showed that the dispersion and increase in brightness occurs in microseconds and lasts only briefly. Cosmoid jetting caused multiple telescope thresholds to be exceeded simultaneously which explains the earlier inabilty to compute trajectories from the measured times in the fields of view. A new calculation correlated the Sisyphus individual event measurements with the zodiacal light. That the meteoroid population is dominated by cosmoids is demonstrated. Reported telescopic small comets, measured by a similar optical technique, appear consistent with the Sisyphus results. Characteristic jetting times measured by Sisyphus also show that the volatile cosmoids could not survive in short period orbits.

Soberman, Robert K.↗

Manometer Measures Gas Flow

Simple apparatus measures time required for gas to displace known volume of water. Apparatus determines amount of gas generated in lead/acid cell during charging by measuring time required for gas to displace measured volume of water between markes in slanted manometer.

Rowlette, J. J.↗

Time recovery measurements using operational GOES and transit satellites

Results of regular monitoring of both the GOES and TRANSIT timing signals over a number of months at the National Bureau of Standards (NBS), Boulder, Colorado are presented. The TRANSIT results include an analysis of how received timing accuracy and stability are affected by: (1) averaging over varying numbers of satellite passes; (2) averaging over different combinations of the five available satellites; (3) using several independent receivers of the same type; and (4) application of published corrections to the received data. Based on monitoring experience to date at NBS, some pros and cons of using each of the available operational systems are discussed. Updated information on recent improvements incorporated into the GOES time code generation and monitoring system at Wallops Island, Virginia is also included.

Beehler, R. E.↗