Conceptual Phase Neutronic and Thermal Analyses for the LEU Conversion of the Transient Reactor Test Facility (TREAT)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present a multi-channel, fast neutron/gamma ray detector array system that utilizes ZnS(Ag) scintillator detectors. The system employs field programmable gate arrays (FPGAs) to do real-time all digital neutron/gamma ray discrimination with pulse height and time histograms to allow count rates in excess of 1,000,000 pulses per second per channel. The system detector number is scalable in blocks of 16 channels.
This document provides an assessment of hazards as required by the National Environmental Policy Act for the alternative of restarting the reactor at the Transient Reactor Test (TREAT) facility by the Resumption of Transient Testing Program. Potential hazards have been identified and screening level calculations have been conducted to provide estimates of unmitigated dose consequences that could be incurred through this alternative. Consequences considered include those related to use of the TREAT Reactor, experiment assembly handling, and combined events involving both the reactor and experiments. In addition, potential safety structures, systems, and components for processes associated with operating TREAT and onsite handling of nuclear fuels and experiments are listed. If this alternative is selected, a safety basis will be prepared in accordance with 10 CFR 830, “Nuclear Safety Management,” Subpart B, “Safety Basis Requirements.”
The Transient Reactor Test Facility (TREAT) reactor is being restarted after over two decades of standby operation. TREAT is designed to test the time-dependent behavior of nuclear fuel during simulated reactor accidents. One of the principle data collection systems of TREAT is the fast neutron hodoscope which is used to observe the motion of the fuel test specimen as it is being damaged, deformed, or melted over the course of the power transient. The hodoscope is a grid of ex-core collimator channels paired with a bank of fast neutron sensitive radiation detectors. These detectors have historically been calibrated using empirical methods utilizing measurement data from smaller power pulses. Given modern computational capabilities this work sets out to establish a predictive computational capability of the fast neutron flux field exiting the hodoscope to support these calibrations.
The Transient REActor Test (TREAT) facility was restarted in 2017 to perform reactor fuels testing under transient conditions, following shutdown in 1994 and 23 years in non-operational standby. TREAT is a transient reactor that, like most pulsing reactors, can create natural shaped power pulses. However, TREAT provides the ability to shape the power pulse and control the energy deposition rate on the test specimens by automatically controlling the amount of reactivity insertion over time. The original automatic reactor control system (ARCS) was created in the 1980s using INTEL 8086 CPU boards and software written in assembly code. The need to maintain the system for the next 40+ years of TREAT life led to the decision to replace ARCS with modern hardware while maintaining the original functionality. After a prototyping effort, the replacement was successfully completed in the first quarter of 2020. The process and results of that effort are reported here.
The Transient Reactor Test (TREAT) Facility is an air-cooled reactor composed of graphite-urania fuel encapsulated in zirconium alloy canisters and surrounded by ~2 ft (~61 cm) of nuclear grade graphite. The primary role of TREAT is to provide in-pile nuclear-heated safety research via transient testing [1]. The following work represents further analyses building upon previously reported work to support larger volume test vehicles within TREAT [2]. The Broad Use Specimen Transient Experiment Rig (BUSTER) provides ample versatility for numerous transient test concepts. However, future testing and experiment needs will require testing environments of different in-core footprints. The versatility of TREAT allows for the development of variegated core layouts with key limitations emplaced as operational safety temperature restrictions and available core reactivity. The focus of this current effort is to gauge core arrangements for TREAT core loadings to support centralized experimental testing of varying dimensional capacity. The total core excess reactivity (ER) was computed for different arrangements to establish comparison tables that enable ready assessment of core ER available for future experiment concepts. Test vehicle worths would then be necessary to establish available ER to support transient testing requirements and to perform reactor performance and safety calculations [3,4].
The Transient Reactor Test (TREAT) Facility is an air-cooled reactor composed of graphite-urania fuel encapsulated in zirconium alloy canisters and surrounded by ~2 ft (~61 cm) of nuclear grade graphite. The primary role of TREAT is to provide in-pile nuclear-heated safety research via transient testing [1]. Benchmark efforts have demonstrated sensitivity of TREAT neutronics models to graphite cross section data and key neutron poisons found in the fuel assemblies [2]. During fabrication of TREAT fuel assemblies, a small concentration of boron was inadvertently introduced with variable concentration into the aggregate of fuel blocks prepared for TREAT use. The concentration of boron, and its respective uncertainty, represent the most sensitive component in a neutronics study; unfortunately, nothing can be done to reduce or otherwise mitigate its impact. Hydrogen in the fuel blocks reduces the mean free path of the core and its true quantity and uncertainty is approximated. The hydrogen remains from pitch binder used in the fuel fabrication process and was not completely released due to incomplete fuel graphitization. Destructive fuel testing is necessary to quantify the actual hydrogen content and to improve benchmark model quality. A third neutron poison of some significance is the hafnium impurity in the Zircaloy-3 (Zry-3) assembly cladding. The quantity of hafnium is expected to be within nominal manufacturing limits for nuclear grade zircaloy. Recladding the fuel assemblies with material that is less neutron absorbing is expected to benefit reactor neutron economy. Moreover, TREAT’s total transient energy is restricted based on the rate of Zry-3 oxidation in TREAT’s air coolant environment. Hence, cladding with more benign air reaction kinetics could dramatically uprate the facility’s experimental capability. Silicon carbide (SiC) has been proposed as a candidate material for recladding TREAT assemblies, as SiC/SiC demonstrate favorable properties within nuclear environments [3]. The current operational limits of TREAT are restricted by the oxidation of Zry-3. Change of the cladding to SiC could feasibly double the current temperature limitation. Recladding opportunities allow for previously damaged fuel assemblies to be returned to service, as Zry-3 is not commercially available. The initial effort required to consider proceeding with any recladding effort is to neutronically characterize key reactor parameters while replacing Zry-3 with SiC. A characterization summary, with respective results, is provided herein.
The restart of the Transient Reactor Test (TREAT) facility has provided a much needed capability for integral transient testing of nuclear fuel. This testing is necessary to qualify new fuel concepts such as those developed under the Accident Tolerant Fuel (ATF) program, increasing the burnup limit of light water reactor (LWR) fuels, or a variety of other programs under the Advanced Fuels Campaign (AFC). The ATF campaign has been the main driver behind the development and implementation of a variety of capsules for TREAT experiments. The Separate-Effect Test Holder (SETH) was a dry capsule that enabled testing of ATF concepts under reactivity-initiated accident (RIA) heating conditions. Following SETH, the Static Environment Rodlet Transient Test Apparatus (SERTTA) was developed to enable RIA testing in a static water environment. In efforts to support the need for future Loss-of-Coolant Accident (LOCA) tests, the Transient Water Irradiation System for TREAT (TWIST) capsule has been developed that allows for water to drain from around the fuel rod and lower the pressure to simulate LOCA conditions. All these capsules that have been developed for LWR fuel testing all lack the capability for forced convective cooling which in some applications may limit their ability to test under prototypic conditions. A design and modeling effort has been started to modify the TWIST capsule by adding a flow tube and impeller that can create flowing coolant conditions for the fuel rod. RELAP5-3D and BISON models are being used to study the differences between RIA, LOCA, Anticipated Operational Occurrences (AOO), LWR power cycling, and other transient scenarios under flowing conditions capable in the flowing capsule and the current stagnant water capsules (SERTTA and TWIST). The scoping study will provide guidance on the needed capabilities for the flowing capsule and the limitations of the currently developed capsule for LWR testing in TREAT.
A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.
Fuel pins with small defects could allow for the gradual ingress of water into the cladding during normal operation. If these 'waterlogged' fuel pins are subjected to a rapid power change, the internal pressurization could greatly exceed that of a normal fuel pin due to rapid conversion of the water to steam. This could induce either a premature or a more energetic failure during a design basis RIA than in non-defected fuel pins. Experimental studies on this type of fuel are very limited and do not appear to have been fully reported in the open literature. Results from a variety of tests conducted at the Transient Reactor Test Facility (TREAT), Special Power Excursion Reactor Test (SPERT) facility, Nuclear Safety Research Reactor (NSRR), and Power Burst Facility (PBF) are reviewed in this paper. These tests were intended to evaluate both the physical consequences of failure and the threshold and causes for waterlogged fuel failure during RIA. The available data suggests that although waterlogged fuel pins may burst at a lower energy deposition threshold, they do not pose a significant new hazard during design basis accidents. However, data is limited to tests conducted on fresh fuel samples only.
A reactivity-initiated accident (RIA) is one type of postulated design basis accident (DBA) that can cause a departure from nucleate boiling (DNB) event in pressurized-water reactors (PWRs). A DNB occurrence and its consequences depend on the thermophysical properties of the fuel components and coolant, characteristics of the transient energy insertion into the fuel rod, and the onset of the critical heat flux (CHF) phenomenon. To leverage the restart of the Transient Reactor Test (TREAT) Facility, an effort is currently underway to better understand the cladding-to-coolant heat transfer mechanisms and the CHF phenomenon under fast-transient irradiation conditions. This paper characterizes the impact of power transients on the thermal-hydraulic behavior of a TREAT Facility reactor heater rodlet CHF experiment to provide the priority of parameters that need to be investigated for an improved CHF model. Sobol sensitivity analysis methods and the Reactor Excursion and Leak Analysis Program (RELAP5-3D) code were used to identify key input parameters on the uncertainty in the prediction of peak outer- and inner-surface temperatures of the heater tube, as well as the time of the DNB event. A series of sensitivity analyses revealed the total energy deposition on the tube and the transient effects of power pulse had large impacts on the maximum temperatures. The CHF multiplier had the largest impact on the time occurrence of CHF. The overall results show the energy deposition rate in the tube is the most influencing factor to the manifestation of CHF and the resulting thermal-hydraulic behaviors of the tube. The multiplier for the CHF, which is interpreted as the predicted CHF value, has the largest Sobol indices for the time of the CHF in all cases, since it directly determines the occurrence of CHF. It is inferred that the uncertainties in the thermal-hydraulic behaviors of fuels increase with respect to the key parameters as the power pulse becomes broader, and an accurate estimation of the energy deposition rate is required to reduce the uncertainty in the evaluation of the integrity of fuel if the CHF is expected to occur near the peak power. Therefore, the outputs are expected to provide rigorous interpretation of ongoing in-pile CHF experiments in the TREAT Facility reactor regarding thermal-hydraulic behavior of the fuel system aiming for a new transient in-pile CHF model.
The Transient Reactor Test (TREAT) that resides at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL), first achieved criticality in 1959, and successfully performed many transient tests on nuclear fuel until 1994 when its operations were suspended. Resumption of operations at TREAT was approved in February 2014 to meet the U.S. Department of Energy (DOE) Office of Nuclear Energy’s objectives in transient testing of nuclear fuels. The National Nuclear Security Administration’s is converting TREAT from its existing highly enriched uranium (HEU) core to a new core containing low enriched uranium (LEU) (i.e., U-235< 20% by weight). The TREAT Conversion project is currently progressing with conceptual design phase activities. Dimensional stability of the fuel element assemblies, predictable fuel can oxidation and sufficient heat conductivity by the fuel blocks are some of the critical performance requirements of the new LEU fuel. Furthermore, to enable the design team to design fuel block and can specifications, it is amongst the objectives to evaluate TREAT LEU fuel and cladding material’s chemical interaction. This information is important to understand the viability of Zr-based alloys and fuel characteristics for the fabrication of the TREAT LEU fuel and cladding. Also, it is very important to make the right decision on what type of nuclear fuel will be used at TREAT. In particular, one has to consider different oxides of uranium, and most importantly, UO 2 vs U 3 O 8 . In this report, the results are documented pertaining to the choice mentioned above (UO 2 vs U 3 O 8 ). The conclusion in favor of using UO 2 was made based on the analysis of historical data, up-to-date literature, and self-consistent calculations of phase equilibria and thermodynamic properties in the U-O and U-O-C systems. The report is organized as follows. First, the criteria that were used to make the choice are analyzed. Secondly, existing historical data and current literature were reviewed. This analysis was supplemented by the construction and examination of the U-O and U-O-C phase diagrams at pressure close to negligent, thereby mimicking the conditions in which nuclear fuel is supposed to function inside the zirconium-based cladding in the reactor. Finally, our conclusion in favor of the UO 2 down selection was summarized and explained in the last Section of this document.
EXECUTIVE SUMMARY The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s and provided thousands of transient irradiations before being placed in standby mode in 1994. In 2017, it resumed operation in order to reclaim its crucial role in nuclear-heated safety research. TREAT is a transient reactor where inherently-safe core physics, a nimble transient rod drive system, and a philosophy of continual facility improvement work together to enable flexible power maneuvers for fuel safety research. While the facility’s flexible design and multi-mission nature saw historic experiments for numerous transient types, TREAT was not specifically adapted to optimize or demonstrate its full performance capability for Light Water Reactor (LWR) postulated accidents including Hot Zero Power Reactivity Initiated Accidents (HZP-RIA) and Loss of Coolant Accidents (LOCA). The physics of HZP-RIA drive very brief pulses with fairly large energy excursions. TREAT is currently capable of approaching HZP-RIA pulse widths through transients initiated on a large step insertion of reactivity and terminated shortly thereafter by rapid re-insertion of the transient rods (“clipping”). LOCAs are postulated to occur quite differently, starting from normal power operations followed by a long period of lower power decay heat. TREAT is able to simulate LOCA events with an initial flattop transient for tens of seconds, followed by a sizeable power reduction, to a longer segment where specimen fission heating represents internal decay heat generation. Two reactor physics testing campaigns were undertaken to address the HZP-RIA type transients, neither of which had been performed in any great measure historically to address data gaps in the timing, repeatability of clipping and effect of dynamic transient rod motions on core-to-specimen fission power coupling. The first campaign, referred to as the Accident Tolerant Fuel (ATF) transient prescription tests, employed dosimeters in the core to characterize the effect of rod motions on specimen power coupling for clipped, unclipped, and low-level steady state operations each with approximately the same moderate core energy release. This campaign was accompanied by efforts to measure dosimetry and compare results to analytic predictions. The other HZP-RIA campaign, referred to as Narrow Pulse Width (NPW) transient prescriptions, employed higher step insertions with increased core energy release to demonstrate TREAT’s capability in achieving the narrowest-possible pulse width. Additionally, a series of LOCA transient prescriptions were also performed to demonstrate how well TREAT could perform long-duration shaped transients. Both NPW and LOCA transient prescriptions did not include dosimeters but used existing plant power instrumentation to produce transient power data. All three transient prescription campaigns were successfully carried out in TREAT. The ATF-3 transient prescriptions showed that TREAT can perform clipped transients with remarkable repeatability. Measurement and modeling both showed that the power coupling in small, fissile dosimeters does not change by more than 8% between clipped, unclipped, and steady state runs while uncertainty sources in both the modeling and measurement methods were identified and found to be on the order of 20% in total. Overall, the ATF-3 transient prescription tests were successful in determining repeatability and consistency of dosimeter power coupling, developing processes for modeling and measuring this crucial parameter, and demonstrating the need for continued efforts in transient prescription work at TREAT in support of future experiment design and post test data interpretation. The NPW and LOCA transient prescriptions were also successfully performed to exhibit TREAT’s capability for these important LWR accident categories. The NPW transients showed pulse widths of ~90 ms, which were the narrowest ever achieved in TREAT to date and relevant for the upper end range of HZP-RIA simulation. This effort provided crucial data for calibrating kinetic models to be used in enhanced pulse-narrowing strategies in upcoming irradiations. Similarly, The LOCA transient prescriptions showed that TREAT can simulate the needed nuclear heating and event time scales for LOCA fuel safety research and provided essential data for future experiment design.
The Transient Reactor Test Facility (TREAT) has historically provided the capability for transient fuel performance and safety testing in the United States. The operation of this facility was suspended in 1994. However, in recent years preparations for the restart of TREAT were initiated. TREAT is a graphite moderated and air cooled reactor. Its core is composed of a 19 x 19 array of fuel assemblies that contain UO{sub 2} (HEU) fuel particles dispersed in a graphite matrix, along with reflector assemblies filled with graphite only. Each fuel assembly is 8 feet tall with a fueled region that is 4 feet tall and upper and lower regions of graphite that are 2 feet tall. In addition, a 2 feet thick radial graphite reflector region is present. Finally, a 5 feet thick concrete biological shield surrounds the core. Previous work showed that the graphite thermal scattering cross sections can introduce variations exceeding 2000 pcm in the predicted eigenvalue of the TREAT core. Recognizing that the graphite in the assembly (and thereby the core) is a porous mixture of crystalline and amorphous carbon (with a lower density in comparison to ideal crystalline graphite), it becomes clear that TREAT specific thermal neutron scattering cross section libraries will be needed (at all temperatures of interest) for use within neutronic codes seeking to simulate TREAT. (authors)
The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory is an air-cooled, thermal, heterogeneous facility used to test reactor materials in simulated accident conditions by inducing fission heating with intense neutron pulses. TREAT operated from 1959 until 1994 with the primary goal of testing fast reactor fuels and was brought back online in 2017 to re-establish DOE's nuclear fuels transient testing capabilities. Beginning in the late 1970s, Idaho National Laboratory worked in conjunction with other organizations to increase TREAT's capability for in-pile testing. While these upgrades had not been implemented by the time the reactor was put into standby mode, new assemblies and graphite-urania fuel blocks with increased uranium concentrations had already been designed and fabricated. This project, as part of Idaho National Laboratory's Department of Reactor Physics, modeled the TREAT Upgrade (TU) fuel assemblies in MCNP and implemented them in an existing TREAT model. Calculations were performed using INL's high performance computer to find a critical combination of TU and standard fuel and this geometry's excess reactivity. Future work will include calculating a power coupling factor in the experiment, determining power peaking factors throughout the core, and assessing how much reactivity would be added by replacing the Inconel-625 cladding with silicon carbide.
The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) is currently preparing for resumption of operation after more than 20 years in a long-term standby state. In parallel with preparation for operations and a new transient testing program, the DOENE Advanced Modeling and Simulation program (NEAMS) has been supporting the development of three-dimensional transient multi-physics modeling capabilities within the reactor physics application MAMMOTH. Recently, the MAMMOTH reactor physics team has begun development of uncertainty and sensitivity analysis for the TREAT core. This research will be used to support the analysis of reactor operation and experiment planning. Traditional approaches, i.e., Monte Carlo simulations, for such tasks require a large number of model evaluations under both steady state and transient conditions. However, exhaustive sets of sampling runs are simply not practical for TREAT since evaluations of each model can take a substantial amount of time. A solution to this problem is to build a surrogate model employing a smaller number of model evaluations. The surrogate model is designed to provide an accurate and fast approximation to the detailed TREAT model. In this manner, the surrogate model can be used in place of the TREAT transient model for uncertainty and sensitivity analysis at a fraction of the computational cost. The high dimensional model representation (HDMR) method is employed here for approximating the responses of interest in terms of functions of lower dimensions. This method has been implemented in RAVEN and all TREAT transient calculations are performed using the multiphysics code MAMMOTH. In addition, a code interface has also been developed in order to couple RAVEN with MAMMOTH. The surrogate model is then tested and compared for TREAT startup testing program Transient Test no. 15 core, and its accuracy is measured by its ability to estimate the mean, coefficient of variance, skewness, excess kurtosis and probability density function of the outputs of Transient Test no. 15 model, as well as root mean square error metric.