Shock-tube water time-histories and ignition delay time measurements for H2S near atmospheric pressure
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not Available
Abstract not provided
Explore the source record for details and available documents.
Abstract not provided.
Principles of connector testing, design evaluation of commercial connectors, and assessment of design rules for threaded connectors
Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.
This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.
Abstract Not Provided
Abstract not provided.
Coolant channel assembly of PHWRs consisting mainly of pressure tube and calandria tube undergoes sag due to irradiation enhanced creep during its life time. Typical service life of the pressure tube is limited to about 15 full power years due to such ageing related degradation. On account of the degradation the pressure tube needs replacement more than twice during the licensed period of reactor operation. As the sag in the calandria tube is also excessive, it has to be replaced to facilitate installation of new and straight pressure tube during retubing and to avoid interference of sagged calandria tube with horizontal reactivity devices. The calandria tube and the tube sheet are joined by sandwich type rolled joints. For detaching the joint an improved technique has been developed that helps to detach the joint without affecting the groove geometry and integrity of the tube sheet. The system works on the principle of fast thermal cycle of heating and cooling of the insert and calandria tube in the rolled joint region while applying axial load to the calandria tube. Though rolled joint detachment by induction heating technique has been in use in CANDU reactors for removal of pressure tubes and calandria tubes, the present design incorporates a liquid nitrogen for faster cooling and simultaneous application of load with a gripping module for detachment and removal of calandria tube and the insert from the tube sheet of end shield in shorter time. This paper describes the methodology of rolled joint detachment, challenges involved in the design, features of the detachment system, findings of experimental trials and observations.
Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.
Magnetic flux in the solar photosphere forms concentrations from small scales, such as flux elements, to large scales, such as sunspots. This paper presents a study of the decay process of large magnetic flux tubes, such as sunspots, on a supergranular scale. Three-dimensional nonlinear resistive magnetohydrodynamic numerical simulations are performed in a cylindrical domain, initialized with axisymmetric solutions that consist of a well-defined central flux tube and an annular convection cell surrounding it. As the nonlinear convection evolves, the annular cell breaks up into many cells in the azimuthal direction, allowing magnetic flux to slip between cells away from the central flux tube (turbulent erosion). This lowers magnetic pressure in the central tube, and convection grows inside the tube, possibly becoming strong enough to push the tube apart. A remnant of the central flux tube persists with nonsymmetric perturbations caused by the convection surrounding it. Secondary flux concentrations form between convection cells away from the central tube. Tube decay is dependent on the convection around the tube. Convection cells forming inside the tube as time-dependent outflows will remove magnetic flux. (This is most pronounced for small tubes.) Flux is added to the tube when flux caught in the surrounding convection is pushed toward it. The tube persists when convection inside the tube is sufficiently suppressed by the remaining magnetic field. All examples of persistent tubes have the same effective magnetic field strength, consistent with the observation that pores and sunspot umbrae all have roughly the same magnetic field strength.
A modification of the design of the pulse tube in a pulse-tube cryocooler reduces axial thermal conductance while preserving radial thermal conductance. It is desirable to minimize axial thermal conductance in the pulse-tube wall to minimize leakage of heat between the warm and cold ends of the pulse tube. At the same time, it is desirable to maximize radial thermal conductance at the cold end of the pulse tube to ensure adequate thermal contact between (1) a heat exchanger in the form of a stack of copper screens inside the pulse tube at the cold end and (2) the remainder of the cold tip, which is the object to which the heat load is applied and from which heat must be removed. The modified design yields a low-heat-leak pulse tube that can be easily integrated with a cold tip. A typical pulse tube of prior design is either a thin-walled metal tube or a metal tube with a nonmetallic lining. It is desirable that the outer surface of a pulse tube be cylindrical (in contradistinction to tapered) to simplify the design of a regenerator that is also part of the cryocooler. Under some conditions, it is desirable to taper the inner surface of the pulse tube to reduce acoustic streaming. The combination of a cylindrical outer surface and a tapered inner surface can lead to unacceptably large axial conduction if the pulse tube is made entirely of metal. Making the pulse-tube wall of a nonmetallic, lowthermal- conductivity material would not solve the problem because the wall would not afford the needed thermal contact for the stack of screens in the cold end. The modified design calls for fabricating the pulse tube in two parts: a longer, nonmetallic part that is tapered on the inside and cylindrical on the outside and a shorter, metallic part that is cylindrical on both the inside and the outside. The nonmetallic part can be made from G-10 fiberglass-reinforced epoxy or other low-thermal-conductivity, cryogenically compatible material. The metallic part must have high thermal conductivity in the cryogenic temperature range and would typically be made of pure copper to satisfy this requirement. The metallic part is bonded to the nonmetallic part with epoxy. Copper screens are inserted in the metallic part to form the cold-end heat exchanger, then the assembled pulse tube is inserted in the cold tip.
Thermally induced steam generator tube rupture (TI-SGTR) can occur in pressurized water reactors (PWRs) with U-tube steam generators (SGs) during high pressure severe accident sequences resulting in containment bypass. Robust natural circulation patterns including in-vessel natural circulation and countercurrent flow to and from the SGs of superheated steam and other hot gases heats cooler structures in the reactor coolant system (RCS). The buoyancy driven flows return cooler and denser gases back to the core slowing the progression of some core degradation phenomena and failure of the lower head. As much as 50 percent of the decay energy and energy produced from core degradation oxidation reactions can be transported from the core to SGs resulting in the heat up and thermal creep of RCS pressure boundary components including hot leg nozzles, pressurizer surge line, and the SG tubes, many of which contain flaws. The creep failure of an individual tube is dependent on the transitory heating of the tube, a function of the mass flow rate through the tube and local temperature history of steam entering the tube. Buoyancy driven natural circulation flow rates are determined by changes in gravitational head, a combination of changes in fluid density due to heat transfer and change in elevation, and irreversible pressure drops resulting primarily from friction loss in the flow paths and other form losses. The nonuniform flow distribution in U-tubes of varying lengths and heights during single-phase liquid and two-phase natural circulation has been extensively studied in scaled test facilities and verified numerically in previous works. We hypothesize the countercurrent natural circulation of single-phase superheated steam in U-tube SGs is governed by the same characteristic pressure drop-flow rates curves of single-phase liquid and two-phase natural circulations in U-tubes connected to common plena derived in. Secondly, we propose flow distribution is a function of U-tube geometry - height, length, hydraulic diameter, etc., and the larger SGs of Combustion Engineering (CE) style 2 x 4 PWRs, which are the focus of this study, will show greater nonuniformity in tube by tube flow rates and ratio of forward flowing tubes to reverse flowing tubes. This work derives characteristic pressure drop-flow rate curves for single-phase superheated steam in CE-type SGs during a high pressure station blackout (SBO) sequence with failed auxiliary feedwater (AFW) and dry secondary side which is closely related to the TI-SGTR event. (authors)
Formation of the neural tube is the morphological hallmark for development of the embryonic central nervous system (CNS). Therefore, neural tube development is a crucial step in the neurulation process. Slit/Robo signaling was initially identified as a chemo-repellent that regulated axon growth cone elongation, but its role in controlling neural tube development is currently unknown. To address this issue, we investigated Slit/Robo1 signaling in the development of chick neCollege of Life Sciences Biocentre, University of Dundee, Dundee DD1 5EH, UKural tube and transgenic mice over-expressing Slit2. We disrupted Slit/Robo1 signaling by injecting R5 monoclonal antibodies into HH10 neural tubes to block the Robo1 receptor. This inhibited the normal development of the ventral body curvature and caused the spinal cord to curl up into a S-shape. Next, Slit/Robo1 signaling on one half-side of the chick embryo neural tube was disturbed by electroporation in ovo. We found that the morphology of the neural tube was dramatically abnormal after we interfered with Slit/Robo1 signaling. Furthermore, we established that silencing Robo1 inhibited cell proliferation while over-expressing Robo1 enhanced cell proliferation. We also investigated the effects of altering Slit/Robo1 expression on Sonic Hedgehog (Shh) and Pax7 expression in the developing neural tube. We demonstrated that over-expressing Robo1 down-regulated Shh expression in the ventral neural tube and resulted in the production of fewer HNK-1{sup +} migrating neural crest cells (NCCs). In addition, Robo1 over-expression enhanced Pax7 expression in the dorsal neural tube and increased the number of Slug{sup +} pre-migratory NCCs. Conversely, silencing Robo1 expression resulted in an enhanced Shh expression and more HNK-1{sup +} migrating NCCs but reduced Pax7 expression and fewer Slug{sup +} pre-migratory NCCs were observed. In conclusion, we propose that Slit/Robo1 signaling is involved in regulating neural tube development by tightly coordinating cell proliferation and differentiation during neurulation. - Highlights: ► The role of Slit/Robo1 signaling was investigated with chick and mouse models. ► Disturbance of Slit/Robo1 signaling resulted in neural tube defects. ► Slit/Robo1 signaling regulated the proliferation of neural tube cells. ► Slit/Robo1 signaling modulated the differentiation of neural tube cells. ► Slit/Robo1 signaling balanced the proliferation and differentiation of neural tube.