Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Low-Cost, High Performance Catalyst Coated Membranes for PEM Water Electrolyzers (Final Technical Report)

In this project, the objective was to develop reduced-cost manufacturing techniques capable of producing proton exchange membrane water electrolyzer (PEMWE) catalyst coated membranes (CCMs) with further improved performance relative to then-current 3M CCM technology. Processes to be developed would enable 1) production of 0.5 m wide CCMs (approximately 2x wider than produced by the current laboratory/pilot-scale processes) and 2) 3x higher net-effective linear rates (lineal-meters of CCM produced per cumulative process time) than the baseline CCM process. In combination, the wider width CCM and increased net-effective linear rates would result in a 6-fold decrease in CCM manufacturing cost (defined as cumulative machine and labor time) per m 2 of CCM produced. PEMWE CCMs produced with these optimized processes were targeted to produce 1) 0.25 A/cm 2 or greater at 1.5 V, 2) 2.0 A/cm 2 or greater at 1.75 V and 3) 4 A/cm 2 or greater at 1.95V, 4) with total catalyst platinum-group metal (PGM) loadings of ≤ 0.50 mg/cm 2 , measured in a cell with 50 cm 2 active area (or larger) at 80°C cell temperature and ambient outlet pressures.

08 HYDROGEN↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Low-cost desalination of seawater and hypersaline brine using nanophotonics enhanced solar energy membrane distillation

A stand-alone small-scale nanophotonics enhanced solar membrane distillation (NESMD) testbed was designed, developed, and tested for desalinating seawater and high salinity feedwaters. This NESMD system can take almost any source water and turn it into clean water with sunlight as the only energy source. The NESMD technology applies nanophotonic coating materials on a commercial hydrophobic polypropylene support of a polytetrafluoroethylene (PTFE) membrane surface. The photothermal coating serves as a solar thermal collector, absorbs solar energy, and generates highly localized heat on the membrane, while the rest of the membrane performs membrane distillation functions. The presented NESMD system is equipped with an internal heat recovery system with no need for external electricity and no additional water for cooling. The NESMD testbed is installed and tested at Rice University campus (29.7174° N, 95.4018° W). In this study, real seawater from Galveston Bay, Texas, U.S. and high salinity simulated feedwaters (total dissolved solids (TDS) of 113 200–200 000 PPM) have been tested for long-term testing under the weather conditions of Houston, Texas. Here, the field testing results showed stable desalination performance in consecutive 5–8 hour operation cycles, with a TDS removal of ≥99.5% in all experiments. An average daily membrane flux of ≥0.75 L m –2 h –1 was achieved at a solar intensity close to 1 kW m –2 without an external heat exchanger. Further investigations and improvements are required to enhance the performance of the reactor since it is still a new promising technology.

14 SOLAR ENERGY↗

HydroGEN Consortium: Advancements in Hydrogen Production

HydroGEN Energy Materials Network (EMN) is an U.S. Department of Energy (DOE) EERE Hydrogen and Fuel Cell Technologies Office (HFTO)-funded consortium that aims to accelerate the discovery and development of advanced water splitting materials (AWSM) for clean, low-cost hydrogen production. Materials innovations are key to enhancing performance, durability, and cost of hydrogen generation technologies. HydroGEN is focused on low technology readiness level AWS technologies, including low- (alkaline exchanged membrane electrolysis) and high-temperature electrolysis (proton-conducting solid oxide electrolysis), photoelectrochecmical (PEC) and thermochemical (TCH) water splitting. The AWS technologies in this consortium study proton conduction in solid oxide electrolysis and hydroxide conduction in polymer electrolysis, and proton transport in photoelectrochemical water splitting. This presentation will provide an overview of the HydroGEN EMN and technical highlights of a few lab-led and DOE-awarded "seedling" R&D projects. HydroGEN continues to grow its community of industry, university, and national laboratories, forming a national innovation ecosystem focused on renewable hydrogen production.

08 HYDROGEN↗

HydroGEN Consortium

HydroGEN Energy Materials Network (EMN) is an U.S. Department of Energy (DOE) EERE Hydrogen and Fuel Cell Technologies Office (HFTO)-funded consortium that aims to accelerate the discovery and development of advanced water splitting materials (AWSM) for clean, low-cost hydrogen production. Materials innovations are key to enhancing performance, durability, and cost of hydrogen generation technologies. HydroGEN is focused on low technology readiness level AWS technologies, including low- (alkaline exchanged membrane electrolysis) and high-temperature electrolysis (proton-conducting solid oxide electrolysis), photoelectrochecmical (PEC) and thermochemical (TCH) water splitting. The AWS technologies in this consortium study proton conduction in solid oxide electrolysis and hydroxide conduction in polymer electrolysis, and proton transport in photoelectrochemical water splitting. This presentation will provide an overview of the HydroGEN EMN and technical highlights of a few lab-led and DOE-awarded "seedling" R&D projects. HydroGEN continues to grow its community of industry, university, and national laboratories, forming a national innovation ecosystem focused on renewable hydrogen production.

08 HYDROGEN↗

HydroGEN Consortium: Advancements in Renewable Hydrogen Production

HydroGEN Energy Materials Network (EMN) is an U.S. Department of Energy (DOE) EERE Hydrogen and Fuel Cell Technologies Office (HFTO)-funded consortium that aims to accelerate the discovery and development of advanced water splitting materials (AWSM) for clean, low-cost hydrogen production. Materials innovations are key to enhancing performance, durability, and cost of hydrogen generation technologies. HydroGEN is focused on low technology readiness level AWS technologies, including low- (alkaline exchanged membrane electrolysis) and high-temperature electrolysis (proton-conducting solid oxide electrolysis), photoelectrochecmical (PEC) and solar thermochemical (STCH) water splitting. This presentation will provide an overview of the HydroGEN EMN and technical highlights of a few lab-led and FOA-awarded R&D projects. HydroGEN continues to grow its community of industry, university, and national laboratories, forming a national innovation ecosystem focused on renewable hydrogen production.

clean hydrogen↗

Absorption/Desorption based high efficiency Supercritical Carbon Dioxide Power Cycles - Final Scientific/Technical Report

The team of Southwest Research Institute® (SwRI®) and Thar Energy LLC (Thar) are advancing the state of the art in fossil-fired closed Brayton supercritical carbon dioxide (sCO 2 ) power cycles. This current effort is focused on evaluating the integration of a fossil-based thermal system with closed Brayton sCO 2 power blocks to understand the impact of thermal integration on plant performance and identification of current technology gaps. This effort is extending the current understanding of how fossil-based thermal systems may best be integrated with recuperated closed Brayton cycles based on the overall impact on the integrated plant efficiency, cost, and operating characteristics. System Engineering Design and Thermodynamic Analysis is being utilized to (1) identify technical challenges impacting the integration of fossil-based thermal sources with highly recuperated closed Brayton sCO 2 power cycles, (2) evaluate the impact of boiler design and sCO 2 cycle configuration on integrated plant performance, cost, and operability, and (3) evaluate technology readiness of the integrated system and identify specific technologies requiring development of advanced fossil-based sCO 2 cycles. Engineering evaluation is being applied to coal- and natural gas-fired thermal systems for sCO 2 power cycles to evaluate current boiler technologies and challenges associated with adapting those to a sCO 2 based configuration. This includes technical evaluation of the sCO 2 heat exchanger design and anticipated performance impacts on the thermal system. In addition to the general evaluation of indirect fossil fires closed Brayton sCO 2 cycles, this effort is also evaluating a novel indirect sCO 2 power cycle that utilizes an absorption/desorption circuit to minimize compression work by 40% to 65%. This translates to a thermodynamic cycle efficiency improvement of 3.2 points for a simple recuperated cycle using a binary CO 2 + Acetone working fluid.

20 FOSSIL-FUELED POWER PLANTS↗

Additive Manufacturing of Ceramic Heat Exchanger: Opportunities and Limits of the Lithography-Based Ceramic Manufacturing (LCM)

Additive manufacturing (AM) techniques allow the preparation of tailor-made structures for specific applications with a high flexibility in regard to shape and design. The lithography-based ceramic manufacturing (LCM) technology allows the AM of high-performance alumina and zirconia components. There are still some restrictions in regard to possible geometries. The opportunities and limits of the LCM technology are discussed in the following paper using the example of ceramic heat exchangers. Structures are presented which combine a large surface for heat exchange with a small component volume and low pressure drop. This paper concludes summarizing the essential remarks.

36 MATERIALS SCIENCE↗

Systematic Studies of the Gas Humidification Effects on Spatial PEMFC Performance Distributions

The overall current density that is measured in a proton exchange membrane fuel cell (PEMFC) represents the average of the local reaction rates. The overall and local PEMFC performances are determined by several primary loss mechanisms, namely activation, ohmic, and mass transfer. Spatial performance and loss variabilities are significant and depend on the cell design and operating conditions. A segmented cell system was used to quantify different loss distributions along the gas channel to understand the effects of gas humidification. A reduction in the reactant stream humidification decreased cell performance and resulted in non-uniform distributions of overpotentials and performance along the flow field. Activation and ohmic overpotentials increased with a relative humidity decrease due to insufficient membrane and catalyst layer hydration. The relative humidity of the cathode had a strong impact on the mass transfer overpotential due to a lower oxygen permeability through the dry Nafion film covering the catalyst surface. The mass transfer loss distribution was non-uniform, and the mass transfer overpotential increased for the outlet segments due to the oxygen consumption at the inlet segments, which reduced the oxygen concentration downstream, and a progressive water accumulation from upstream segments. Electrochemical impedance spectroscopy (EIS) and an equivalent electric circuit (EEC) facilitated the analysis and interpretation of the segmented cell data.

08 HYDROGEN↗

RAMI Analysis for Designing and Optimizing Tokamak Cooling Water System (TCWS) for the ITER's Fusion Reactor

U.S.-ITER is responsible for the design, engineering, and procurement of the Tokamak Cooling Water System (TCWS). TCWS is designed to provide cooling and baking for client systems that include the first wall/blanket, vacuum vessel, divertor, and neutral beam injector. Additional operations that support these primary functions include chemical control of water provided to client systems, draining and drying for maintenance, and leak detection/localization. TCWS interfaces with 27 systems including the secondary cooling system, which rejects this heat to the environment. TCWS transfers heat generated in the Tokamak during nominal pulsed operation - 850 MW at up to 150 C and 4.2 MPa water pressure. Impurities are diffused from in-vessel components and the vacuum vessel by water baking at 200-240 C at up to 4.4 MPa. TCWS is complex because it serves vital functions for four primary clients whose performance is critical to ITER's success and interfaces with more than 20 additional ITER systems. Conceptual design of this one-of-a-kind cooling system has been completed; however, several issues remain that must be resolved before moving to the next stage of the design process. The 2004 baseline design indicated cooling loops that have no fault tolerance for component failures. During plasma operation, each cooling loop relies on a single pump, a single pressurizer, and one heat exchanger. Consequently, failure of any of these would render TCWS inoperable, resulting in plasma shutdown. The application of reliability, availability, maintainability, and inspectability (RAMI) tools during the different stages of TCWS design is crucial for optimization purposes and for maintaining compliance with project requirements. RAMI analysis will indicate appropriate equipment redundancy that provides graceful degradation in the event of an equipment failure. This analysis helps demonstrate that using proven, commercially available equipment is better than using custom-designed equipment with no field experience and lowers specific costs while providing higher reliability. This paper presents a brief description of the TCWS conceptual design and the application of RAMI tools to optimize the design at different stages during the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perovskite Catalysts for Pure-Water-Fed Anion-Exchange-Membrane Electrolyzer Anodes: Co-design of Electrically Conductive Nanoparticle Cores and Active Surfaces

Anion-exchange-membrane water electrolyzers (AEMWEs) are a possible low-capital-expense, efficient, and scalable hydrogen-production technology with inexpensive hardware, earth-abundant catalysts, and pure water. However, pure-water-fed AEMWEs remain at an early stage of development and suffer from inferior performance compared with proton-exchange-membrane water electrolyzers (PEMWEs). One challenge is to develop effective non-platinum-group-metal (non-PGM) anode catalysts and electrodes in pure-water-fed AEMWEs. We show how LaNiO3-based perovskite oxides can be tuned by cosubstitution on both A- and B-sites to simultaneously maintain high metallic electrical conductivity along with a degree of surface reconstruction to expose a stable Co-based active catalyst. The optimized perovskite, Sr0.1La0.9Co0.5Ni0.5O3, yielded pure-water AEMWEs operating at 1.97 V at 2.0 A cm-2 at 70 °C with a pure-water feed, thus illustrating the utility of the catalyst design principles.

Zhai, Tingting↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Thin Film Morphological Characteristics of a Perfluorinated Anion Exchange Membrane

Anion exchange membranes (AEMs) are a promising technology for fuel cell applications. Most of the research done to date was focused on membrane development, electrode fabrication, or cell performance. Studies of the polymer catalyst interface are needed in order to advance the science of these devices and achieve further improvements. In this work we have studied these interfacial properties using grazing-incidence small-angle x-ray scattering (GISAXS). Thin films of a perfluorinated anion exchange polymer were spin cast onto bare, or silver or platinum coated flat silicon substrates. From the GISAXS data, we can conclude that the polymer chains align parallel to the plain silicon or silver coated substrate at higher thicknesses, >17 nm and, >13 nm respectively. However, on the coated platinum substrate the alignment is somewhere between parallel and perpendicular. The in-plane alignment of ionomer on the surface constrains the swelling of water channels which affects the transport of reactants and products.

30 DIRECT ENERGY CONVERSION↗

Complex software dedicated for design and simulation of LPCE process for heavy water detritiation

The main purpose of this paper is to present a comprehensive software, SICA, designed to be used in water-hydrogen liquid phase catalytic exchange process (LPCE). The software calculates the water-gas catalytic isotopic exchange process, following the transfer of any H, D or T isotope from water to gas and vice versa. This software is useful for both design and laboratory-based research; the type of the catalytic filling (ordered or random) can be defined for any of these 2 cases, the isotopic calculation being specific to the package type. For the laboratory-based research, the performance of a catalytic packing can be determined by knowing the type and by using experimental results. Performance of the mixed catalytic packing is defined by mass transfer constants for each catalytic and hydrophilic package in that specific arrangement, and also for the isotope whose transfer is studied from one phase to another. Also, it has been established a link between these constants and commonly used parameters for the fillings performance defined by HETP (Height Equivalent of Theoretical Plate). To demonstrate the performance of the software, we present a comparative analysis of water-gas catalytic isotopic exchange on a column equipped with 3 types of filling: successive layers, random and structured (ordered package filled with catalyst). The program can be used for the LPCE process calculation, process used at detritiation facilities for CANDU reactors or fusion reactors. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the importance of the heat and mass transfer resistances in internally-cooled liquid desiccant dehumidifiers and regenerators

Liquid desiccant heat and mass exchangers are a promising technology for efficient humidity control in buildings. Many researchers have investigated these exchangers, often using numerical models to predict their performance. However, there is a lack of information in the literature on the magnitude of the heat and mass transfer resistances, both for the dehumidifier (which absorbs moisture from the air) and the regenerator (which heats the liquid desiccant to re-concentrate it). This article focuses on internally-cooled, 3-fluid exchangers in a parallel plate geometry. Water heats or cools a desiccant across a plate, and the desiccant absorbs or releases water into an airstream through a membrane. A sensitivity analysis was used to estimate the importance of each of the heat and mass transfer resistances (air, membrane, desiccant, plate, water), and how it changes with different design geometries. The results show that, for most designs, the latent and sensible heat transfer of the dehumidifier is dominated by the air mass transfer resistance and air heat transfer resistance, respectively. The air mass transfer resistance is also important for the regenerator, but much less so; the change in the desiccant equilibrium humidity ratio due to a change in either temperature or desiccant mass fraction is much higher at the regenerator's higher temperatures. This increases the importance of (1) getting heat from the water to the desiccant/membrane interface, and (2) diffusing salt ions quickly away from the desiccant/membrane interface. The membrane heat transfer and water heat transfer resistances were found to be the least important. These results can help inform decisions about what simplifying assumptions to make in numerical models, and can also help in designing these exchangers by understanding which resistances are most important.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Non-PGM Catalysts for High-Temperature PEMFCs

The objective of this project was to revolutionize high-temperature proton exchange membrane fuel cell (PEMFC) technology based on polymer membranes imbibed with phosphoric acid through development of stable, high-performance non-precious cathode catalysts. High-temperature PEMFCs operate in a range of 150-220 degrees centigrade, making them ideal candidates for combined heat and power (CHP) applications. Successful catalyst development showed potential to be translated to other solid acid systems such as those based on the Cs2HPO4 (CDP) electrolyte. This incubator effort was however exclusively focused on catalyst development for H3PO4-imbibed PEMFCs.

08 HYDROGEN↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗