Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Resonant Compton scattering and gamma-ray burst continuum spectra

The Thomson limit of resonant inverse Compton scattering in the strong magnetic fields of neutron stars is considered as a mechanism for producing gamma-ray burst continuum spectra. Photon production spectra and electron cooling rates are presented using the full magnetic Thomson cross-section. Model emission spectra are obtained as self-consistent solutions of a set of photon and electron kinetic equations, displaying spectral breaks and other structure at gamma-ray energies.

Baring, M. G.↗

Temporal and spectral properties of Comptonized radiation

Relationships are found between the temporal and spectral properties of radiation Compontonized in an extended atmosphere associated with compact accreting sources. It is demonstrated that the power spectrum density imposes constraints on the atmosphere's scale and profile. It is indicated that the slope and low frequency break of the power spectrum density are related to the Thomson depth of the atmosphere and the radius of its physical size, respectively. This relationship allows an independent estimate to be made of the accreting matter Thomson depth. The temporal properties of the high and low state of black hole sources are discussed.

Kazanas, Demos↗

Determination of the Peltier Coefficient of Germanium in a Vertical Bridgeman-Stockbarger Furnace

The Peltier effect is the fundamental mechanism that makes interface demarcation through current pulsing possible. If a method for calculating the necessary current density for effective demarcation is to be developed, it will be necessary to know the value of the Peltier coefficient. This study determined experimentally the value of the Peltier coefficient for gallium-doped germanium by comparing the change in average growth rates between current-on and current-off periods. Current-on and current-off layer thickness measurements were made using differential interference contrast microscopy and atomic force microscopy. It was found that the Joule and Thomson effects could not be neglected. Peltier coefficients calculated from the experimental data with an analysis that accounts for Joule, Thomson, and Peltier effects yielded an average value for the Peltier coefficient of 0.076 +/- 0.015 V.

Weigel, Michaela E. K.↗

Deep Asca Campaign to Probe one Typical Broad Absorption Line Qso

We present a deep ASCA observation of a broad absorption line quasar (BALQSO) PG 0946+301. The source was clearly detected in one of the gas imaging spectrometers, but not in any other detector. If BALQSOs have intrinsic X-ray spectra similar to normal radio-quiet quasars, our observations imply that there is Thomson thick X-ray absorption (NH(1024 per square centimeter) toward PG 0946+301. This is the largest column density estimated so far toward a BALQSO. The absorber must be at least partially ionized and may be responsible for attenuation in the optical and UV. If the Thomson optical depth toward BALQSOs is close to 1, as inferred here, then spectroscopy in hard X-rays with large telescopes like XMM would be feasible.

Green, P.↗

Instrumentation and Measurements for Electron Emission from Charged Insulators

The electron was first discovered in 1898 by Sir John Joseph Thomson and has since been the subject of detailed study by nearly every scientific discipline. At nearly the same time Heinrich Rudolf Hertz conducted a series of experiments using cathode tubes, high potentials and ultraviolet light. When applying a large potential to a cathode he found that an arching event across the metal plates would occur. In addition, when shining an ultraviolet light on the metal he found that less potential was required to induce the spark. This result, taken together with other electrical phenomena brought about by the shining of light upon metal and was eventually termed the photoelectric effect. The work of Thomson and Hertz represent the beginning of electron emission studies and a body of ideas that pervade nearly all aspects of physics. In particular these ideas tell us a great deal about the nature of physical interactions within solids. In this thesis we will focus on the emission of electrons induced by an incident electron source over a range of energies, in which one can observe changes in emitted electron flux and energy distribution. In particular, when energetic particles impinge on a solid they can impart their energy, exciting electrons within the material. If this energy is sufficient to overcome surface energy barriers such as the work function, electron affinity or surface charge potential, electrons can escape from the material. The extent of electron emission from the material can be quantified as the ratio of incident particle flux to emitted particle flux, and is termed the electron yield.

Sim, Alec M.↗

Testing the Effects of Helium Pressurant on Thermodynamic Vent System Performance with Liquid Hydrogen

In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1

Flachbart, R. H.↗

Compositional Pathways and Capillary Effects during Early-stage Isothermal Precipitation in a Nondilute Ni-Al-Cr Alloy

For a Ni-5.2 Al-14.2 Cr at.% alloy with moderate solute supersaturations, the compositional pathways, as measured with atom-probe tomography, during early to later stage y'(LI2)-precipitation (R = 0.45-10 nm), aged at 873 K, are discussed in light of a multi-component coarsening model. Employing nondilute thermodynamics, detailed model analyses during quasistationary coarsening of the experimental data establish that the y/y' interfacial free-energy is 22- 23+/-7 mJ/sq m. Additionally, solute diffusivities are significantly slower than model estimates. Strong quantitative evidence indicates that an observed y'-supersaturation of Al results from the Gibbs-Thomson effect, providing the first experimental verification of this phenomenon. The Gibbs-Thomson relationship, for a ternary system, as well as differences in measured phase equilibria with CALPHAD assessments, are considered in great detail.

Sudbrack, Chantal K.↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Simulating Thermoelectric Devices Using the MOOSE Framework

Thermoelectric generators (TEG) are devices that generate energy by converting heat into electricity or provide cooling via the Peltier effect. This feature of thermoelectric devices originates from the Seebeck, Peltier, Thomson, and Joule heating effects. TEGs can be applied in energy and thermal management systems such as waste heat recovery and refrigeration, respectively. Thermoelectric device design is influenced by the material selection and the device's geometry operating conditions. Therefore, predicting, verifying, and validating thermoelectric device performance using simulations tools is essential to deploying thermoelectric devices in industry. The Multiphysics Object-Oriented Simulation Environment (MOOSE) Framework is an open-source simulation tool capable of modeling simple to complex systems. In this work, we demonstrate MOOSE's thermoelectric device modeling capabilities by simulating a unicouple, module, and exhaust gas recovery system. The Seebeck, Peltier, Thomson, and Joule heating physics are implemented into MOOSE. The MOOSE thermoelectric physics were thoroughly verified and validated using published COMSOL® results and experimental data. In addition, thermoelectric modules were integrated into an exhaust gas recovery system using the MOOSE MultiApp function as a demonstration of the model's ability. The verification and validation results and exhaust gas heat recovery system showcases MOOSE's capability to model thermoelectric devices and integrate these devices into practical energy systems.

42 - ENGINEERING↗

Reconciling calculations and measurements of inverse bremsstrahlung absorption

It was recently shown that the use of Coulomb logarithms appropriate for bremsstrahlung radiation (rather than transport processes) along with corrections for the Langdon effect and ion screening reproduced measurements of collisional absorption in well-characterized underdense plasmas [D. Turnbull et al., Phys. Rev. Lett. 130, 145103 (2023)]. However, it was recognized at the time that the use of the standard absorption-reduction factor from Langdon's seminal paper was inconsistent with the use of Coulomb logarithms that are thermally averaged over a Maxwellian electron-velocity distribution function. A more accurate approach would be to average over the expected super-Gaussian distribution function while accounting for the Gaunt factor's velocity dependence, which somewhat mitigates the Langdon effect; however, at that time, this theory matched the data less well. This conflict is now eliminated with the additional insight that the ionization state of our mid-Z ion species (when present) was lower than had been assumed, as evidenced by the Thomson-scattering data and time-dependent Cretin simulations. We are now able to show that an improved treatment of the Langdon effect provides the best match to data. Otherwise, the prior conclusions remain unchanged. We also show an example of the substantial expected impact to the absorption rate in calculations of indirect-drive hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial confinement of wire array Z-pinch precursor plasmas by a pulsed magnetic mirror field

A novel wire-array Z-pinch platform has been developed to study the effect of a pulsed magnetic mirror field on a collisional high energy density plasma. The mirror is driven in series with the Z-pinch target and, therefore, scales with driver current. Axial confinement is observed based on visible imaging and axial flow velocity measurements. The presence of axial compressing J xB force is determined indirectly based on Thomson scattering and interferometry measurements and corroborated by three-dimensional extended-MHD simulations. Compared to non-magnetized wire array Z-pinch, a modified pulsed mirror configuration is observed to increase precursor plasma thermal energy density by about 30%. If optimized, such a configuration could potentially improve magnetized liner inertial fusion performance by reducing axial plasma end loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma pressure profiles in a sheared-flow-stabilized Z-pinch

We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of magnetic reconnection at low- β using laser-powered capacitor coils

Magnetic reconnection is a ubiquitous fundamental process in space and astrophysical plasmas that rapidly converts magnetic energy into some combination of flow energy, thermal energy, and non-thermal energetic particles. Over the past decade, a new experimental platform has been developed to study magnetic reconnection using strong coil currents powered by high-power lasers at low plasma beta, typical conditions under which reconnection is energetically important in space and astrophysics. KJ-class lasers were used to drive parallel currents to reconnect MG-level magnetic fields in a quasi-axisymmetric geometry, similar to the magnetic reconnection experiment or MRX, and thus this platform is named micro-MRX. This presentation summarizes two major findings from micro-MRX: direct measurement of accelerated electrons and observation of ion acoustic waves during anti-parallel reconnection. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that direct acceleration by the out-of-plane reconnection electric field is at work. Furthermore, a sudden onset of ion acoustic bursts has been measured by collective Thomson scattering in the exhaust of magnetic reconnection, followed by electron acoustic bursts with electron heating and bulk acceleration. These results demonstrate that the micro-MRX platform offers a novel and unique approach to study magnetic reconnection in the laboratory in addition to the capabilities provided by traditional magnetized plasma experiments such as MRX and the upcoming Facility for Laboratory Reconnection experiments (FLARE). Future prospects to study other particle acceleration mechanisms and ion acoustic waves from magnetic reconnection are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

Evaluating nonlocal heat transport in directly driven chromium spheres using x-ray spectroscopy

We report on experiments investigating heat transport in laser-generated plasmas using directly driven chromium spheres. The spheres are fielded at the OMEGA laser facility and are driven with laser intensities of 5×10 14 Wcm −2 . Plasma conditions in the corona and scattered light are measured experimentally and compared against predictions from two-dimensional (2D) radiation-hydrodynamic simulations using different heat transport models. Spectroscopic analysis of x-ray self-emission is used as an additional diagnostic. X-ray emission is integrated over a large region of the plasma, probing regions that are not observed by localized optical Thomson scattering. In particular, x-ray emission peaks near the plasma critical density, so emission from optically thin lines provides information on plasma conditions where nonlocal transport is most likely to be significant. Three common heat transport models are considered: local transport with flux limiters f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. Consistent with previous work, both the high-flux (f = 0.15) and SNB models show good agreement with experimentally measured plasma conditions in the corona despite overpredicting laser absorption, whereas the low-flux (f = 0.03) model fails to match any experimental data. Conditions inferred from x-ray self-emission line ratios support this conclusion during the period of laser peak power, although synthetic spectra for all models fail to match the experiment during the transient portions of the pulse. For these reasons, the low-flux model is again rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗