Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two-Phase Heat Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Role of f Electrons in the Optical and Photoelectrochemical Behavior of Ca(La 1– x Ce x ) 2 S 4 (0 ≤ x ≤ 1)

This study focuses on a solid solution series, Ca(La 1– x Ce x ) 2 S 4 (0 ≤ x ≤ 1), where the f electron density is absent in CaLa 2 S 4 and is progressively increased until it is maximized in CaCe 2 S 4 . Correspondingly, these samples, synthesized by a sealed ampule method, showed progressive variations in color ranging from gray for CaLa 2 S 4 to orange-red for CaCe 2 S 4 . The crystal structural nuances of both the end members and three solid solutions with $x$ = 0.25, 0.50, and 0.75 were established with the complementary use of synchrotron X-ray diffraction and neutron scattering. Interestingly, these data were consistent with a two-phase composition centered around each nominal solid solution stoichiometry. Optical characterization via diffuse reflectance spectroscopy and Tauc analyses showed a shrinking of the energy band gap (from the UV to vis range) when Ce was progressively introduced into the host CaLa 2 S 4 structure. Overall, these data were in concert with electronic band structure calculations, using density functional theory, which showed the progressive formation of an intermediate f band when Ce was introduced intro the structure. Photoelectrochemical measurements in an aqueous redox electrolyte, as well as surface photovoltage and Kelvin probe measurements, revealed all samples to be n-type semiconductors. The valence and conduction band edge positions of the end members and the three solid solutions could be mapped, on both the redox and vacuum reference energy scales, by combining these measurements with the optical data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

Integrated Simulation Framework for Additively Manufactured Ti-6Al-4V: Melt Pool Dynamics, Microstructure, Solid-State Phase Transformation, and Microelastic Response

In this work, to accelerate the establishment of fundamental understanding of the additive manufacturing (AM) process and its influence on microstructural evolution and related properties, we develop a multiphysics and multiscale modeling framework that integrates: (1) a high-fidelity powder-scale three-dimensional simulation of transient heat transfer and melt flow dynamics, (2) cellular automaton simulation of solidification grain structure and texture, (3) phase-field modeling of precipitation and dissolution of second-phase precipitate during repeated thermal cycles, and (4) microstructure-based micro- and mesoscopic elastic response calculation. Using Ti-6Al-4V as a model system, we demonstrate the application of the integrated framework to simulate complex microstructure evolution during a single-track laser powder bed fusion process and the associated mechanical response. Our modeling framework successfully captures the solidification β grain structure as a function of laser power and scanning speed, α precipitation upon subsequent cooling with different rates, and elastic response of the resulting (α + β) two-phase microstructure. The key features of solidification and second-phase precipitate microstructures, and their dependence on processing parameters, agree well with existing experimental observations. Finally, the established modeling framework is generally applicable to other metallic materials fabricated by AM.

36 MATERIALS SCIENCE↗

Similarity solution for a two-phase one-dimensional Stefan problem with a convective boundary condition and a mushy zone model

A two-phase solidification process for a one-dimensional semi-infinite material is considered. It is assumed that it is ensued from a constant bulk temperature present in the vicinity of the fixed boundary, which it is modelled through a convective condition (Robin condition). The interface between the two phases is idealized as a mushy region and it is represented following the model of Solomon, Wilson, and Alexiades. An exact similarity solution is obtained when a restriction on data is verified, and it is analysed the relation between the problem considered here and the problem with a temperature condition at the fixed boundary. Moreover, it is proved that the solution to the problem with the convective boundary condition converges to the solution to a problem with a temperature condition when the heat transfer coefficient at the fixed boundary goes to infinity, and it is given an estimation of the difference between these two solutions. Results in this article complete and improve the ones obtained in Tarzia (Comput Appl Math 9:201–211, 1990).

97 MATHEMATICS AND COMPUTING↗

Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus

Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical derivation of a Nusselt number in a thermally stratified enclosure

A hydrophilic gelatin suspension possesses thermal properties that may affect the ratio of convective to conductive heat transfer across a boundary. This ratio, also known as Nusselt's number, can represent laminar or turbulent flow regimes. In this study, thermal transitioning empirical values were determined using a gelatin as a polymer gel surrogate. The crux of this study was to (a) quantify heat transfer properties of the gelatin as a suspended semi-solid and (b) understand thermal profiles with respect to particle size and loading. We can adduce the existence of a thermally induced: lower rise velocity, stratified Nusselt number, and a boundary layer.

42 ENGINEERING↗

Multi-fidelity electrochemical modeling of thermally activated battery cells

Thermally activated batteries undergo a series of coupled physical changes during activation that influence battery performance. These processes include energetic material burning, heat transfer, electrolyte phase change, capillary-driven two-phase porous flow, ion transport, electrochemical reactions, and electrical transport. Several of these processes are strongly coupled and have a significant effect on battery performance, but others have minimal impact or may be suitably represented by reduced-order models. Additionally, assessing the relative importance of these phenomena must be based on comparisons to a high-fidelity model including all known processes. In this work, we first present and demonstrate a high-fidelity, multi-physics model of electrochemical performance. This novel multi-physics model enables predictions of how competing physical processes affect battery performance and provides unique insights into the difficult-to-measure processes that happen during battery activation. We introduce four categories of model fidelity that include different physical simplifications, assumptions, and reduced-order models to decouple or remove costly elements of the simulation. Using this approach, we show an order-of-magnitude reduction in computational cost while preserving all design-relevant quantities of interest within 5 percent. The validity of this approach and these model reductions is demonstrated by comparison between results from the full fidelity model and the different reduced models.

25 ENERGY STORAGE↗

Benchmark of interfacial area concentration approaches for the two-fluid model in gas-dispersed condensing flow

Accurate predictions of interfacial area concentration (IAC) are required for closure of the condensation phase change term. The interfacial area transport equation (IATE) can dynamically predict interfacial area concentration and is increasingly being used in the benchmarking of phase change flows over static based correlations which require a flow regime map. For higher flow regimes, the two-group two-fluid IATE model can separately model the transport of spherical bubbles and cap/slug bubbles. Recently, a modified formulation of the one-group and two-group two-fluid model with interfacial area transport equation was proposed for gas-dispersed condensing flows. Three datasets have been used for validation consisting of condensing two-phase flow data in the unheated section of a vertical annulus with conditions spanning a range of pressures, inlet subcoolings and mass fluxes for benchmarking the various IAC approaches. For bubbly flows, the coupled void transport - IATE simulation results in good agreement in the predictions of the void fraction and the interfacial area concentration under nearly all sixty conditions. Considering the proposed two-group two-fluid IATE model formulation, the group-2 Nusselt number correlation is investigated to account for the appropriate heat transfer length scale for group-2 bubbles. Validation of the proposed two-group two-fluid model against the new dataset shows good agreement with experimental data with significant improvement over the one-group IATE model for conditions with substantial group-2 void fraction throughout the simulation domain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Simulation of Boiling Two-Phase Flow in a Helical Coil Steam Generator Using the Spectral Element Code Nek-2P

To enable the design of a light water small modular reactor, the boiling flow inside a helical coil steam generator has been simulated with the two-fluid model in Nek-2P. Nek-2P is the multiphase branch of the spectral element code Nek5000. Details of the implementation of the two-fluid model and the included closure models are discussed. The presented closure models include interactions for momentum, heat, and mass transfer between phases. Models for the drag, lift, and turbulent dispersion forces are included. The complete model is fully consistent in the limits of both phasic volume fractions approaching zero and is able to simulate flows of dispersed vapor, continuous liquid, dispersed liquid, continuous vapor, or any combination thereof. The closure models and their implementation in Nek-2P have been validated by comparing to experimental data for a boiling flow, demonstrating excellent agreement. Results from the simulation of the helical coil indicate strong phasic separation driven by the effects of buoyancy and inertia. Finally, significant differences were observed in the results compared to simulations performed using Star-CCM+, although these differences were somewhat expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Addressing Two-Phase Flow Maldistribution in Microchannel Heat and Mass Exchangers

Multiphase flow phenomena in single micro and minichannels have been widely studied. Characteristics of two-phase flow through a large array of microchannels are investigated here. An air–water mixture is used to represent the two phases flowing through a microchannel array representative of those employed in practical applications. Flow distribution of the air and water flow across 52 parallel microchannels of 0.4 mm hydraulic diameter is visually investigated using high-speed photography. Two microchannel configurations are studied and compared, with mixing features incorporated into the second configuration. Slug and annular flow regimes are observed in the channels. Void fractions and interfacial areas are calculated for each channel from these observations. The flow distribution is tracked at various lengths along the microchannel array sheets. Statistical distributions of void fraction and interfacial area along the microchannel array are measured. The design with mixing features yields improved flow distribution. Void fraction and interfacial area change along the length of the second configuration, indicating a change in fluid distribution among the channels. The void fraction and interfacial area results are used to predict the performance of different microchannel array configurations for heat and mass transfer applications. Results from this study can help inform the design of compact thermal-fluid energy systems.

Engineering↗

Pronghorn

Pronghorn is designed as a multi-dimensional coarse-mesh conjugate heat transfer simulator (tightly coupled fluid and solid phase heat transfer) for nuclear reactor core applications. Pronghorn’s design philosophy of is that: 1. The tool will be agnostic of reactor concept, including VHTRs, SFRs, FHRs, and LWRs. 2. Must be higher fidelity than traditional nuclear systems/safety analysis (0D-1D). 3. Avoid lower-length scale phenomena, such as boundary layer theory, i.e., rely on closure relations. 4. Apply mixture theory (homogenization) wherever possible. 5. Conserve mass and energy (solve all physics on single mesh). 6. Must be easily coupled to both MOOSE-based and external physics applications. 7. Does not require a super computer. Thus, Pronghorn’s algorithmic philosophy is to resolve large scale flow features and model lower-length scale phenomena, such as boundary layers. The coarse mesh approach for lower-length scale modeling is to develop a multi-component multi-phase homogenization of solid and liquid phases into a mixture formulation inside a finite element. For example, a pebble bed core is represented as a two-phase mixture of coolant and fuel pebbles, where the fuel phase is stationary. Thus, the solid phase exerts a drag force on the fluid phase, composed of form and viscous drag, and both phases exchange internal energy through conduction and convective heat transfer. For Pronghorn, the volume fraction of fluid can vary in space, but not in time. Pronghorn has been validated against the VHTR PBMR400 benchmark problems, used for rod ejection simulations have been conducted for thermal-fluids/neutronics for both pebble-bed and prismatic gas-cooled reactors and simple thermal-neutronics coupled LWR benchmark problems. Pronghorn flow models cover a wide range of transient and steady flow conditions, including, porous fluid flow, compressible flow, and nearly incompressible, thermally expansive flow. The physics can be solved in three-dimensional Cartesian coordinates and two-dimensional cylindrical (r-z) coordinates.

Martineau, RichardC.↗

High Performance Computing to Enable Next-Generation Low-Temperature Waste Heat Recovery

US manufacturing industry fails to recover an estimated 900 trillion BTUs of low-temperature waste heat from its processes each year. A grand research challenge has been to develop waste heat recovery technology that can be applied to industrial manufacturing processes and vehicle operations. The Oak Ridge National Laboratory (ORNL)/Eaton research team performed computational research and development to design an innovative direct-contact heat exchanger (DCHE) technology to deliver low-cost, compact, longer-lifetime, high-efficiency waste heat recovery that is optimized for a low-temperature organic Rankine cycle. ORNL resources and expertise in high performance computing (HPC) and multiphase flows were utilized to realize this goal while advancing the fundamental understanding of two-phase, two-immiscible-fluid turbulent flow heat transfer for heat exchangers. In the first stage of the project, a computational fluid dynamics (CFD) model of a DCHE was developed. Verification and limited validation of the numerical solution were performed using experimental data from published literature. To support efforts in verification and validation, two-dimensional CFD models were also developed with the objective of investigating different boundary conditions to reach converged, steady-state solutions.Based on benchmarking efforts, a baseline industry-grade design of a DCHE was developed, which consists of two horizontal pipes of different cross-sectional areas – joined by a converging-diverging nozzle in the middle and relies on a three-phase system with co-current flows for operation. Evaporation of the cold liquid (n-pentane or methanol) by the hot liquid water occurs in the first pipe. The first pipe contains two inlets for liquid water and liquid pentane (or liquid methanol). The second pipe with the larger cross-sectional area serves as a gravity-driven phase-separator. It contains two outlets that are staggered to avoid entrainment of the liquid water phase by the gas phase. This baseline design resulted from several trial-and-error evaluations using two-dimensional CFD models. Confirmatory three-dimensional CFD models were also run for different mass flow rates and inlet temperatures (inlet water temperature ranging from 50°C to 90°C), and efficiency plots were produced to fully characterize the proposed industrial-grade design of the DCHE.

97 MATHEMATICS AND COMPUTING↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Steam-Electric Power Cycle for Advanced Reactor Concepts

This report presents improvements made to RELAP-7 for modeling Rankine power cycles, which are used on the secondary side of some advanced reactor concepts. For example, for a High-Temperature gas-cooled Reactor Pebble bed Module (HTR-PM), in the primary loop, helium transfers heat from the fuel to a steam generator, and on the secondary side, dry steam from the steam generator applies work to a turbine, which is converted into electrical power by a generator. After passing through the turbine, the steam passes through a condenser and pumped to the steam generator inlet, completing a Rankine cycle on the secondary side. This HTR-PM concept is used as an example to demonstrate a steam-electric power cycle capability in RELAP-7. This power cycle requires a number of different physical components, including a pump, compressor, turbine, steam generator, and condenser. The steam generator is modeled using a heat exchange between primary and secondary loops, and the condenser is modeled using a cooling source term. Recent efforts demonstrated preliminary models for the turbomachinery components (pump/compressor and turbine), but more physical models were required. Furthermore, several improvements were made for the robustness of mixed single-phase/two-phase flow present in a Rankine cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Deflagration to Detonation Transition Update: XDDT Code Modularization

A legacy FORTRAN 77 implementation of the Baer–Nunziato two-phase mixture theory for deflagration-to-detonation transition (DDT) in reactive granular materials—hereafter the XDDT (eXplosive DDT) code—has been modularized to Fortran 90 with modular structure, external input files, and adaptive mesh capability. During validation, two code defects were identified and corrected: an inconsistency in the nodal solid pressure evaluation and a nonphysical burn-front tracking criterion. The ignition criterion was also corrected to use the granular surface temperature from the interface heat transfer model, matching the original Baer implementation. An initial attempt to validate against Figure 3 of the original Baer and Nunziato (1986) paper revealed that the code’s detonation velocity on a 201-node mesh (5.5 km/s) was approximately 21% below the expected Chapman–Jouguet value for 70% TMD HMX (∼7 km/s). Validation was redirected to the piston-driven DDT experiments of McAfee et al. (1989), Shot B-9036, for which well-characterized ionization-pin data are available. With the compaction-burn coefficient calibrated to 𝐶 𝛼 = 75, the XDDT code reproduces the DDT transition time to within 0.4% and produces a steady-state detonation velocity within 4% of the McAfee experimental value of 6.36 km/s. The burn model was generalized to support pressure-dependent exponents, enabling application to nitrocellulose-based ball propellants (TS3659) with a cube-root pressure dependence. Validation against the Sandusky/Baer PDC82 piston-impact experiment yielded a reactive wave velocity of 2.3–2.8 km/s, in good agreement with the experimental value of ∼2.2 km/s, and wave coalescence within 5% of the experimental timing. The mathematical model, input parameter requirements, and a roadmap for extending XDDT to PETN with an autocatalytic burn model are presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗