WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Water-soluble drug partitioning and adsorption in HEMA/MAA hydrogels

Two-photon confocal microscopy and back extraction with UV/Vis-absorption spectrophotometry quantify equilibrium partition coefficients, k, for six prototypical drugs in five soft-contact-lens-material hydrogels over a range of water contents from 40 to 92%. Partition coefficients were obtained for acetazolamide, caffeine, hydrocortisone, Oregon Green 488, sodium fluorescein, and theophylline in 2-hydroxyethyl methacrylate/methacrylic acid (HEMA/MAA, pK a ≈ 5.2) copolymer hydrogels as functions of composition, aqueous pH (2 and 7.4), and salinity. At pH 2, the hydrogels are nonionic, whereas at pH 7.4, hydrogels are anionic due to MAA ionization. Solute adsorption on and nonspecific electrostatic interaction with the polymer matrix are pronounced. To express deviation from ideal partitioning, we define an enhancement or exclusion factor, E≡k/φ 1 , where φ 1 is hydrogel water volume fraction. All solutes exhibit E>1 in 100wt % HEMA hydrogels owing to strong specific adsorption to HEMA strands. For all solutes, E significantly decreases upon incorporation of anionic MAA into the hydrogel due to lack of adsorption onto charged MAA moieties. For dianionic sodium fluorescein and Oregon Green 488, and partially ionized monoanionic acetazolamide at pH 7.4, however, the decrease in E is more severe than that for similar-sized nonionic solutes. Conversely, at pH 2, E generally increases with addition of the nonionic MAA copolymer due to strong preferential adsorption to the uncharged carboxylic-acid group of MAA. For all cases, we quantitatively predict enhancement factors for the six drugs using only independently obtained parameters. In dilute solution for solute i , E i is conveniently expressed as a product of individual enhancement factors for size exclusion (E$_i^{ex}$), electrostatic interaction (E$_i^{el}$), and specific adsorption (E$_i^{ad}$):E$_i$≡E$_i^{ex}$E$_i^{el}$E$_i^{ad}$. Finally, to obtain the individual enhancement factors, we employ an extended Ogston mesh-size distribution for Eiex; Donnan equilibrium for E$_i^{el}$; and Henry's law characterizing specific adsorption to the polymer chains for E$_i^{ad}$. Predicted enhancement factors are in excellent agreement with experiment.

back extraction↗

Fast molecular shocks. I - Reformation of molecules behind a dissociative shock

The physical and chemical processes that operate in the cooling gas behind a fast, dissociative, single-fluid shock propagating in a dense interstellar cloud are discussed. The treatment extends previous theoretical work on fast molecular shocks by including the effects of the conversion of Ly-alpha photons into radiation of the two-photon continuum and into H2 Lyman band emission lines, the effects of CO photodissociation following line absorption, and the formation and destruction of molecules containing the elements nitrogen, silicon, and sulphur, and of the complex hydrocarbons. Abundance profiles for the molecular species of interest are presented. After molecular hydrogen begins to reform, by means of gas phase and grain surface processes, the neutral species OH, H2O, O2, CO, CN, HCN, N2, NO, SO, and SiO reach substantial abundances. The molecular ions HeH(+), OH(+), SO(+), CH(+), H2(+), and H3(+), are produced while the gas is still hot and partially ionized. Emissions from them provide a possible diagnostic probe of fast molecular shocks.

Neufeld, David A.↗

Trapping Rydberg Atoms in an Optical Lattice

Rubidium Rydberg atoms are laser excited and subsequently trapped in a one-dimensional optical lattice (wavelength 1064 nm). Efficient trapping is achieved by a lattice inversion immediately after laser excitation using an electro-optic technique. The trapping efficiency is probed via analysis of the trap-induced shift of the two-photon microwave transition 50S{yields}51S. The inversion technique allows us to reach a trapping efficiency of 90%. The dependence of the efficiency on the timing of the lattice inversion and on the trap laser power is studied. The dwell time of 50D{sub 5/2} Rydberg atoms in the lattice is analyzed using lattice-induced photoionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of a π-Type Dipole-Bound State in Molecular Anions

We report the observation of a π-type dipole-bound state (π-DBS) in cryogenically cooled deprotonated 9-anthrol molecular anions (9AT – ) by resonant two-photon photoelectron imaging. A DBS is observed 191 cm –1 (0.0237 eV) below the detachment threshold, and the existence of the π-DBS is revealed by a distinct (s + d)-wave photoelectron angular distribution. The π-DBS is stabilized by the large anisotropic in-plane polarizability of 9AT. Here, the population of the dipole-forbidden π-DBS is proposed to be via a nonadiabatic coupling with the dipole-allowed σ-type DBS mediated by molecular rotations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural dynamics of laser-ionized cis-stilbene studied by ultrafast electron diffraction

Stilbene has been a model system for studying photoisomerization upon absorption of a UV photon. Although the dynamics of the first excited state have been investigated in great detail, the structural dynamics of cationic states remains largely experimentally unexplored. In this study, the dynamics following ionization via absorption of two UV photons was captured using ultrafast electron diffraction. cis-stilbene (CS) was optically pumped with 267 nm ultraviolet light with two different pump fluences and probed with 3.7 MeV electrons. We compare our experimental results to ab-initio multiple spawning simulations for single-photon excitation and molecular dynamics simulations for ionization in order to separate the contributions from the two channels. We found that with a fluence of 170 mJ cm −2 both the single and two-photon channels are present, while with higher fluence of 280 mJ cm −2 the two-photon channel dominates. We did not observe isomerization of the CS cation and found the main structural motion a to be a vibration of the phenyl rings about the central C–C bond.

74 ATOMIC AND MOLECULAR PHYSICS↗

O{sub 2} rotational temperature measurements in an atmospheric air microdischarge by radar resonance-enhanced multiphoton ionization

Nonintrusive spatially resolved rotational temperature measurements in an atmospheric air microdischarge are presented. The measurements were based on coherent microwave Rayleigh scattering (Radar) from resonance-enhanced multiphoton ionization of molecular oxygen. The open air DC microdischarge source operated in a stable 'normal-glow' mode and pin-to-pin electrodes spaced 1.3 mm apart. The second harmonic of a tunable dye laser beam was focused between the two electrodes and scanned between 286 and 288 nm. Coherent microwave Rayleigh scattering was used to collect the two-photon rotational spectra of O{sub 2} at C{sup 3}{Pi}(v = 2) Leftwards-Arrow X{sup 3}{Sigma}(v Prime = 0) transitions. The Boltzmann plots from analyses of the O{sub 2} rotational lines determined local rotational temperatures at various axial locations between the electrodes. The molecular oxygen rotational temperature varied from {approx}1150 K to {approx}1350 K within the discharge area. The measurements had an accuracy of {approx}{+-}50 K.

74 ATOMIC AND MOLECULAR PHYSICS↗

Predissociation of high-lying Rydberg states of molecular iodine via ion-pair states

Velocity map imaging of the photofragments arising from two-photon photoexcitation of molecular iodine in the energy range 73 500–74 500 cm{sup −1} covering the bands of high-lying gerade Rydberg states [{sup 2}Π{sub 1/2}]{sub c}6d;0{sub g}{sup +} and [{sup 2}Π{sub 1/2}]{sub c}6d;2{sub g} has been applied. The ion signal was dominated by the atomic fragment ion I{sup +}. Up to 5 dissociation channels yielding I{sup +} ions with different kinetic energies were observed when the I{sub 2} molecule was excited within discrete peaks of Rydberg states and their satellites in this region. One of these channels gives rise to images of I{sup +} and I{sup −} ions with equal kinetic energy indicating predissociation of I{sub 2} via ion-pair states. The contribution of this channel was up to about 50% of the total I{sup +} signal. The four other channels correspond to predissociation via lower lying Rydberg states giving rise to excited iodine atoms providing I{sup +} ions by subsequent one-photon ionization by the same laser pulse. The ratio of these channels varied from peak to peak in the spectrum but their total ionic signal was always much higher than the signal of (2 + 1) resonance enhanced multi-photon ionization of I{sub 2}, which was previously considered to be the origin of ionic signal in this spectral range. The first-tier E0{sub g}{sup +} and D{sup ′}2{sub g} ion-pair states are concluded to be responsible for predissociation of Rydberg states [{sup 2}Π{sub 1/2}]{sub c}6d;0{sub g}{sup +} and [{sup 2}Π{sub 1/2}]{sub c}6d;2{sub g}, respectively. Further predissociation of these ion-pair states via lower lying Rydberg states gives rise to excited I(5s{sup 2}5p{sup 4}6s{sup 1}) atoms responsible for major part of ion signal. The isotropic angular distribution of the photofragment recoil directions observed for all channels indicates that the studied Rydberg states are long-lived compared with the rotational period of the I{sub 2} molecule.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-precision laser spectroscopy of the CO A{sup 1}Π - X{sup 1}Σ{sup +} (2,0), (3,0), and (4,0) bands

High-precision two-photon Doppler-free frequency measurements have been performed on the CO A{sup 1}Π - X{sup 1}Σ{sup +} fourth-positive system (2,0), (3,0), and (4,0) bands. Absolute frequencies of forty-three transitions, for rotational quantum numbers up to J = 5, have been determined at an accuracy of 1.6 × 10{sup −3} cm{sup −1}, using advanced techniques of two-color 2 + 1’ resonance-enhanced multi-photon ionization, Sagnac interferometry, frequency-chirp analysis on the laser pulses, and correction for AC-Stark shifts. The accurate transition frequencies of the CO A{sup 1}Π - X{sup 1}Σ{sup +} system are of relevance for comparison with astronomical data in the search for possible drifts of fundamental constants in the early universe. The present accuracies in laboratory wavelengths of Δλ/λ = 2 × 10{sup −8} may be considered exact for the purpose of such comparisons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissociation energies of Ag–RG (RG = Ar, Kr, Xe) and AgO molecules from velocity map imaging studies

The near ultraviolet photodissociation dynamics of silver atom—rare gas dimers have been studied by velocity map imaging. Ag–RG (RG = Ar, Kr, Xe) species generated by laser ablation are excited in the region of the C ({sup 2}Σ{sup +})←X ({sup 2}Σ{sup +}) continuum leading to direct, near-threshold dissociation generating Ag* ({sup 2}P{sub 3/2}) + RG ({sup 1}S{sub 0}) products. Images recorded at excitation wavelengths throughout the C ({sup 2}Σ{sup +})←X ({sup 2}Σ{sup +}) continuum, coupled with known atomic energy levels, permit determination of the ground X ({sup 2}Σ{sup +}) state dissociation energies of 85.9 ± 23.4 cm{sup −1} (Ag–Ar), 149.3 ± 22.4 cm{sup −1} (Ag–Kr), and 256.3 ± 16.0 cm{sup −1} (Ag–Xe). Three additional photolysis processes, each yielding Ag atom photoproducts, are observed in the same spectral region. Two of these are markedly enhanced in intensity upon seeding the molecular beam with nitrous oxide, and are assigned to photodissociation of AgO at the two-photon level. These features yield an improved ground state dissociation energy for AgO of 15 965 ± 81 cm{sup −1}, which is in good agreement with high level calculations. The third process results in Ag atom fragments whose kinetic energy shows anomalously weak photon energy dependence and is assigned tentatively to dissociative ionization of the silver dimer Ag{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging ring-current wave packets in the helium atom

We study the reconstruction of a wave packet and the corresponding electron dynamics in an atom via photoelectron angular distributions (PADs) in a pump-probe scheme as a function of time delay. The method is applied to the superposition of ground and one or two excited states in helium atom representing field-free charge migrations on the attosecond timescale in form of ring currents around the core. It is based on the interference between one- and two-photon transitions from ground and excited states into the continuum. In the reconstruction predictions of first- and second-order perturbation theory are used to determine the unknown phases and amplitudes from the PADs, which we simulate via solutions of the time-dependent Schrödinger equation in single-active-electron approximation. Results of calculations show that the reconstruction technique works well for peak laser intensities less than 10 13 W/cm 2 . Knowledge of the electric field of the probe pulse is required with shot-to-shot variations of carrier-to-envelope phase and peak intensity of up to 10% and 20%, respectively. The relevance of different one- and two-photon pathways for the reconstruction as a function of peak intensity and pulse duration is analyzed—specifically their role for ultrashort probe pulses with broad bandwidths.

74 ATOMIC AND MOLECULAR PHYSICS↗

Resonant control of photoelectron directionality by interfering one- and two-photon pathways

Coherent control of interfering one- and two-photon processes has for decades been the subject of research to achieve the redirection of photocurrent. The present study develops two-pathway coherent control of ground-state helium atom above-threshold photoionization for energies up to the N = 2 threshold, based on a multichannel quantum defect and R-matrix calculation. Three parameters are controlled in our treatment: the optical interference phase ΔΦ, the reduced electric field strength χ = $\mathscr{E}^2_ω$$\mathscr{E}_{2ω}$, and the final state energy ε. A small energy change near a resonance is shown to flip the emission direction of photoelectrons with high efficiency, through an example where 90% of photoelectrons whose energy is near the 2p 2 1 S e resonance flip their emission direction. However, the large fraction of photoelectrons ionized at the intermediate state energy, which are not influenced by the optical control, make this control scheme challenging to realize experimentally.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Importance of one- and two-photon transitions in the strong-field dissociation of NO 2+

Employing a coincidence three-dimensional momentum imaging technique, we investigate the ultrafast, intense laser-induced dissociation of a metastable NO 2+ ion beam into N + + O + . Based on the kinetic energy release and angular distributions, measured using both 774-nm and second-order-harmonic 387-nm pulses, we show that the main processes driving dissociation in pulses of about 10 14 W/cm 2 peak intensity are one- and two-photon transitions from the X 2 Σ + ground state to the A 2 Π first-excited state. First-order perturbation theory calculations also corroborate these findings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multipolariton control in attosecond transient absorption of autoionizing states

Tunable attosecond transient absorption spectroscopy is an ideal tool for studying and manipulating autoionization dynamics in the continuum. We investigate near-resonant two-photon couplings between the bright 3s –1 4p and dark 3s –1 4f autoionizing states of argon that lead to Autler-Townes-like interactions, forming entangled light-matter states or polaritons. We observe that one-photon couplings with intermediate dark states play an important role in this interaction, leading to the formation of multiple polaritonic branches whose energies exhibit avoided crossings as a function of the dressing-laser frequency. Our experimental measurements and theoretical essential-state simulations show good agreement and reveal how the delay, frequency, and intensity of the dressing pulse govern the properties of autoionizing polariton multiplets. Furthermore, these results demonstrate new pathways for quantum control of autoionizing states with optical fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗