Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRASONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ultrasonic Nondestructive Evaluation Techniques Applied to the Quantitative Characterization of Textile Composite Materials

An overall goal of this research has been to enhance our understanding of the scientific principles necessary to develop advanced ultrasonic nondestructive techniques for the quantitative characterization of advanced composite structures. To this end, we have investigated a thin woven composite (5-harness biaxial weave). We have studied the effects that variations of the physical parameters of the experimental setup can have on the ultrasonic determination of the material properties for this thin composite. In particular, we have considered the variation of the nominal center frequency and the f-number of the transmitting transducer which in turn address issues such as focusing and beam spread of ultrasonic fields. This study has employed a planar, two-dimensional, receiving pseudo-array that has permitted investigation of the diffraction patterns of ultrasonic fields. Distortion of the ultrasonic field due to the spatial anisotropy of the thin composite has prompted investigation of the phenomenon of phase cancellation at the face of a finite-aperture, piezoelectric receiver. We have performed phase-sensitive and phase-insensitive analyses to provide a measure of the amount of phase cancellation at the face of a finite-aperture, piezoelectric receiver. The pursuit of robust measurements of received energy (i.e., those not susceptible to phase cancellation at the face of a finite-aperture, piezoelectric receiver) supports the development of robust techniques to determine material properties from measure ultrasonic parameters.

Miller, James G.↗

An Ultrasonic Technique to Determine the Residual Strength of Adhesive Bonds

In this work, ultrasonic techniques to nondestructively evaluate adhesive bond degradation have been studied. The key to the present approach is the introduction of an external factor which pulls the adhesive bond in the nonlinear range, simultaneously with the application of an ultrasonic technique. With the aid of an external static tensile loading, a superimposed longitudinal wave has.been used to obtain the slopes of the stress-strain curve of an adhesive bond at a series of load levels. The critical load, at which a reduction of the slope is detected by the superimposed longitudinal wave, is an indication of the onset of nonlinear behavior of the adhesive bond, and therefore of bond degradation. This approach has been applied to the detection of adhesive bond degradation induced by cyclic fatigue loading. Analogously to the longitudinal wave case, a superimposed shear wave has been used to obtain the effective shear modulus of adhesive layers at different shear load levels. The onset of the nonlinear behavior of an adhesive bond under shear loading has been detected by the use of a superimposed shear wave. Experiments show that a longitudinal wave can also detect the nonlinear behavior when an adhesive bond is subjected to shear loading. An optimal combination of ultrasonic testing and mechanical loading methods for the detection of degradation related nonlinear behavior of adhesive bonds has been discussed. For the purpose of a practical application, an ultrasonic technique that uses a temperature increase as an alternative to static loading has also been investigated. A general strain-temperature correspondence principle that relates a mechanical strain to a temperature has been presented. Explicit strain-temperature correspondence relations for both the tension and shear cases have been derived. An important parameter which quantifies the relation between the wave velocity and temperature has been defined. This parameter, which is indicative of adhesive bond nonlinearity and which can be conveniently obtained by an ultrasonic measurement, has been used as an indication of adhesive bond degradation. Experimental results have shown that the temperature increase method is a convenient and productive alternative to static loading. A technique which uses the reflected waveform data to obtain the fundamental ultrasonic parameters (transit time, reflection coefficient and attenuation coefficient) of an adhesive bond has also been presented.

Achenbach, J. D.↗

Ultrasonic Imaging Technology Helps American Manufacturer of Nondestructive Evaluation Equipment Become More Competitive in the Global Market

Sonix, Inc., of Springfield, Virginia, has implemented ultrasonic imaging methods developed at the NASA Lewis Research Center. These methods have heretofore been unavailable on commercial ultrasonic imaging systems and provide significantly more sensitive material characterization than conventional high-resolution ultrasonic c-scanning. The technology transfer is being implemented under a cooperative agreement between NASA and Sonix, and several invention disclosures have been submitted by Dr. Roth to protect Lewis interests. Sonix has developed ultrasonic imaging systems used worldwide for microelectronics, materials research, and commercial nondestructive evaluation (NDE). In 1993, Sonix won the U.S. Department of Commerce "Excellence in Exporting" award. Lewis chose to work with Sonix for two main reasons: (1) Sonix is an innovative leader in ultrasonic imaging systems, and (2) Sonix was willing to apply the improvements we developed with our in-house Sonix equipment. This symbiotic joint effort has produced mutual benefits. Sonix recognized the market potential of our new and highly sensitive methods for ultrasonic assessment of material quality. We, in turn, see the cooperative effort as an effective means for transferring our technology while helping to improve the product of a domestic firm.

Source record↗

Ultrasonic Data Display and Analysis System Developed (Including Fuzzy Logic Analysis) for the Windows-Based PC

Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact measurement data obtained at NASA Glenn Research Center's Ultrasonic Nondestructive Evaluation measurement facility. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary waveforms in the time and frequency domains along with the calculation of several frequency-dependent properties including phase velocity and attenuation coefficient and several frequency-independent properties, like the cross correlation velocity. The system allows image generation on all the frequency-dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency-independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of indepth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on an SQL data base. It is ideal for the classification of material properties or the location of microstructure variations in materials. Along with the ultrasonic contact measurement software that it is partnered with, this system is technology ready and can be transferred to users worldwide.

Lovelace, Jeffrey J.↗

New Approach to Ultrasonic Spectroscopy Applied to Flywheel Rotors

Flywheel energy storage devices comprising multilayered composite rotor systems are being studied extensively for use in the International Space Station. A flywheel system includes the components necessary to store and discharge energy in a rotating mass. The rotor is the complete rotating assembly portion of the flywheel, which is composed primarily of a metallic hub and a composite rim. The rim may contain several concentric composite rings. This article summarizes current ultrasonic spectroscopy research of such composite rings and rims and a flat coupon, which was manufactured to mimic the manufacturing of the rings. Ultrasonic spectroscopy is a nondestructive evaluation (NDE) method for material characterization and defect detection. In the past, a wide bandwidth frequency spectrum created from a narrow ultrasonic signal was analyzed for amplitude and frequency changes. Tucker developed and patented a new approach to ultrasonic spectroscopy. The ultrasonic system employs a continuous swept-sine waveform and performs a fast Fourier transform on the frequency spectrum to create the spectrum resonance spacing domain, or fundamental resonant frequency. Ultrasonic responses from composite flywheel components were analyzed at Glenn to assess this NDE technique for the quality assurance of flywheel applications.

Harmon, Laura M.↗

Ultrasonication of Bismuth Telluride Nanocrystals Fabricated by Solvothermal Method

The objective of this study is to evaluate the effect of ultrasonication on bismuth telluride nanocrystals prepared by solvothermal method. In this study, a low dimensional nanocrystal of bismuth telluride (Bi2Te3) was synthesized by a solvothermal process in an autoclave at 180 C and 200 psi. During the solvothermal reaction, organic surfactants effectively prevented unwanted aggregation of nanocrystals in a selected solvent while controlling the shape of the nanocrystal. The atomic ratio of bismuth and tellurium was determined by energy dispersive spectroscopy (EDS). The cavitational energy created by the ultrasonic probe was varied by the ultrasonication process time, while power amplitude remained constant. The nanocrystal size and its size distribution were measured by field emission scanning electron microscopy (FESEM) and a dynamic light scattering system. When the ultrasonication time increased, the average size of bismuth telluride nanocrystal gradually increased due to the direct collision of nanocrystals. The polydispersity of the nanocrystals showed a minimum when the ultrasonication was applied for 5 min. Keywords: bismuth telluride, nanocrystal, low-dimensional, ultrasonication, solvothermal

Chu, Sang-Hyon↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

An Analysis of Peak Wind Speed Data from Collocated Mechanical and Ultrasonic Anemometers

This study focuses on a comparison of peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. The legacy mechanical wind instruments on CCAFS/KSC and VAFB weather towers are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. The wind tower networks on KSC/CCAFS and VAFB have 41 and 27 towers, respectively. Launch Weather Officers, forecasters, and Range Safety analysts at both locations need to understand the performance of the new wind sensors for a myriad of reasons that include weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The Legacy sensors measure wind speed and direction mechanically. The ultrasonic RSA sensors have no moving parts. Ultrasonic sensors were originally developed to measure very light winds (Lewis and Dover 2004). The technology has evolved and now ultrasonic sensors provide reliable wind data over a broad range of wind speeds. However, because ultrasonic sensors respond more quickly than mechanical sensors to rapid fluctuations in speed, characteristic of gusty wind conditions, comparisons of data from the two sensor types have shown differences in the statistics of peak wind speeds (Lewis and Dover 2004). The 45th Weather Squadron (45 WS) and the 30 WS requested the Applied Meteorology Unit (AMU) to compare data from RSA and Legacy sensors to determine if there are significant differences in peak wind speed information from the two systems.

Short, David A.↗

Ultrasonic Measurement and Monitoring of Loads in Bolts used in Structural Joints

The paper is an overview of work by the author in measuring and monitoring loads in bolts using an ultrasonic extensometer. A number of cases of bolted joints are covered. These include, a clamped joint with clearance fit between the bolt and hole, a clamped joint with the bolt in an interference fit with the hole, a flanged joint which allows the flange and bolt to bend; and a shear joint in a clevis and tang configuration. These applications were initially developed for measuring and monitoring preload in the NASA Space Shuttle Orbiter critical joints but are also applicable for monitoring loads in other critical bolted joints of structures such as transportation bridges and other aerospace structures. The paper explains how to set‐up a model to estimate the load factor and accuracy for the ultrasonic preload application in a clamped joint with clearance fit. The ultrasonic preload application for clamped joint with bolt in an interference fit can also be used to measure diametrical interference between the bolt shank and hole; and interference pressure on the bolt shank. Model and experimental data are given to demonstrate use of ultrasonic measurements in a shear joint. A bolt in a flanged joint experiences both tensile and bending loads. This application involves measurement of bending and tensile preload in a bolt. The ultrasonic beam bends due to the bending load on the bolt. A numerical technique to compute the trace of ultrasonic ray is presented.

Koshti, Ajay↗

Assessment and Calibration of a Crimp Tool Equipped with Ultrasonic Analysis Features

A method is provided for calibrating ultrasonic signals passed through a crimp formed with respect to a deformable body via an ultrasonically-equipped crimp tool (UECT). The UECT verifies a crimp quality using the ultrasonic signals. The method includes forming the crimp, transmitting a first signal, e.g., a pulse, to a first transducer of the UECT, and converting the first signal, using the first transducer, into a second signal which defines an ultrasonic pulse. This pulse is transmitted through the UECT into the crimp. A second transducer converts the second signal into a third signal, which may be further conditioned, and the ultrasonic signals are calibrated using the third signal or its conditioned variant. An apparatus for calibrating the ultrasonic signals includes a pulse module (PM) electrically connected to the first and second transducers, and an oscilloscope or display electrically connected to the PM for analyzing an electrical output signal therefrom.

Yost, William T.↗

Ultrasonic Device for Assessing the Quality of a Wire Crimp

A system for determining the quality of an electrical wire crimp between a wire and ferrule includes an ultrasonically equipped crimp tool (UECT) configured to transmit an ultrasonic acoustic wave through a wire and ferrule, and a signal processor in communication with the UECT. The signal processor includes a signal transmitting module configured to transmit the ultrasonic acoustic wave via an ultrasonic transducer, signal receiving module configured to receive the ultrasonic acoustic wave after it passes through the wire and ferrule, and a signal analysis module configured to identify signal differences between the ultrasonic waves. The signal analysis module is then configured to compare the signal differences attributable to the wire crimp to a baseline, and to provide an output signal if the signal differences deviate from the baseline.

Yost, William T.↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Sources of Uncertainty in Ultrasonic Phase-Based Assessment of Interfacial Stiffness in Adhesive Joints

Quantitative nondestructive evaluation (NDE) of adhesive joint strength is critical for certifying fastener-free bonded aerospace structures. Unfortunately, available adhesive NDE approaches are only suitable for detecting gross defects and delamination and cannot reliably detect variations in strength in intact bonds. Intact (i.e., nominally defect free) bonds are challenging to inspect because they, by definition, contain no macroscopic defects that would produce a strong NDE signature. Even in the absence of obvious defects, however, bond strength can vary substantially due to factors such as contamination, variations in the adhesive cure processes, and environmental exposure. For ultrasonic bond inspections, the effect of interactions from an imperfect adhesive interface are subtle and may include changes in the frequency content or phase of the ultrasonic signal. The bond condition can be deduced from these subtle changes in the acoustic response using an accompanying physics-based model of adhesive joint interaction. For example, researchers have used the spring network adhesion model of Baik and Thompson [1] to determine the interfacial stiffness of the joint from its ultrasonic response (e.g., [2]). This interfacial stiffness metric describes the bonds resistance to separation between the adhesive and adherent and has shown a strong correlation with joint strength. In this study, interfacial stiffness is assessed using the ultrasonic phase change associated with bond interaction in varying bond conditions. The phase change is measured precisely using a phase-locked-loop instrument over a swept range of frequencies. The phase transition at resonance, where the bond thickness is half the acoustic wavelength, produces a unique signature with which to fit a physics-based model. Interfacial stiffness is determined by minimizing the difference between the theoretical and experimental phase response. Experimental results are presented for glass specimens bonded with aerospace adhesives and a sensitivity analysis is performed to examine the effects of parameters that may be uncertain in the industrial inspection environment – namely bond thickness, adhesive and adherent properties, and porosity. The results are a first step toward an uncertainty quantified version of the measurement technique, show correlation between interfacial stiffness and bond strength, and are another key step toward maturing this approach for use in complex materials and joint geometries. [1] Baik, J.M. and Thompson, R.B., 1984. “Ultrasonic scattering from imperfect interfaces: a quasi-static model”. Journal of Nondestructive Evaluation, 4. [2] Haldren, H.A., Perey, D.F., Yost, W.T., Cramer, K.E., and Gupta, M.C., 2019. “Swept-frequency ultrasonic phase evaluation of adhesive bonding in tri-layer structures”. Journal of the Acoustical Society of America, 145.

Matt Webster↗

The effect of non-uniform temperature and velocity fields on long range ultrasonic measurement systems in MYRRHA

SCK.CEN, the Belgian Nuclear Research Center, is developing MYRRHA, a generation IV liquid metal cooled nuclear research reactor. As the liquid metal coolant is opaque to light, normal visual feedback during fuel manipulations is not available and must therefore be replaced by a system that is not hindered by the opacity of the coolant. In this respect ultrasonic based instrumentation is under development at SCK.CEN to provide feedback during operations under liquid metal. One of the tasks that will be tackled using ultrasound is the detection and localization of a potentially lost fuel assembly. In this application, the distance between ultrasonic sensor and target may be as large as 2.5 m. At these distances, non uniform velocity and temperature fields in the liquid metal potentially influence the propagation of the ultrasonic signals, affecting the performance of the ultrasonic systems. In this paper, we investigate how relevant temperature and velocity gradients inside the liquid metal influence the propagation of ultrasonic waves. The effect of temperature and velocity gradients are simulated by means of a newly developed numerical ray-tracing model. The performance of the model is validated by dedicated water experiments. The setup is capable of creating velocity and temperature gradients representative for MYRRHA conditions. Once validated in water, the same model is used to make predictions for the effect of gradients in the MYRRHA liquid metal environment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of Laser Ultrasonics for Detection of Surface-Connected Rail Defects

Laser ultrasonic produces frequencies in the MHz range, enabling high accuracy and a strong ability to detect rail surface defects. This paper mainly studied on the simulation of detecting surface-connected rail defects on 60 kg rails with laser ultrasonic, established the finite element model of laser-excited ultrasonic Rayleigh wave, carried out the simulation, and verified the effectiveness of the technology through experiments. To solve the problem that laser ultrasonic is insensitive to the width of defects in actual detection, and unable to make quantitative detection of defects, this paper established a new model on the basis of improving the original model that has been verified, exciting ultrasonic at the two sides at the same time of a rail with two staggered beams of laser separately to detect irregular scratch defects on rail surface, and two groups of signal data were received through two probes. Each group of data can present the half-profile information of defects, and further form two detection images of the defect. At last, the two detection images were combined into a complete image through image processing. The results of the experiment indicate that the technology studied offers a new method for the effective quantitative detection of surface-connected defects on rail.

42 ENGINEERING↗

Simulation of Bubble Behavior in a Water Physical Model of an Aluminum Degassing Ladle Unit Employing Compound Technique of Rotary Blowing and Ultrasonic

A two-dimensional volume of fluid (VOF) model was developed to simulate the behavior of bubbles in a physical model of the aluminum degassing unit employing the compound technique of rotary blowing and ultrasonic. The effect of rotation speed on bubble behavior under rotating flow field, and the effects of ultrasonic parameters including the amplitude, length, and position of ultrasonic end-face on bubble behavior under compound field were analyzed according to the simulation results, respectively. The experiment shows the simulation results for the bubble shape and trajectory agree well with the experimental observations. Under single rotating flow field, the rotation speed has a strong impact upon bubble trajectory and the optimal speed is 450 rpm. Under compound field, ultrasonic can increase the number of broken bubbles, and push bubbles to further area, which is beneficial to strengthen the bubble distribution and improve the degassing effect. The appropriate amplitude, length, and position of ultrasonic end-face are 23 μm, 50 mm, and 185 mm.

36 MATERIALS SCIENCE↗

New insights into the mechanism of ultrasonic atomization for the production of metal powders in additive manufacturing

Ultrasonic atomization is one of the promising technologies for producing metal powders for additive manufacturing, where precise control of particle size and morphology is essential. In this study, we coupled an ultrasonic transducer with a carbon fiber plate and atomized liquid droplets and films under different vibration amplitudes. Water, glycerol, and pure aluminum melt were used to study the atomization mechanism and the resulting droplet/powder characteristics, respectively. High-speed optical and ultrafast synchrotron X-ray imaging were used to study in situ the ultrasonic atomization dynamics, including pulsation and clustering of cavities inside the liquid layer/films, development of capillary waves, and formation of liquid droplets. For the first time, we observed and captured the occurrence of cavitation during the atomization of resting drops, films and impact droplets. The inertial cavitation events interfered with the capillary waves across the interphase boundary, puncturing and breaking the boundary to produce atomized mist. The in situ observation revealed the intricate dynamics of ultrasonic atomization and underscored the pivotal role of cavitation events throughout the entire atomization process. We also conducted experiments on ultrasonic atomization of liquid aluminum, producing particles of perfectly spherical shape. The particle size tended to decrease with reduced vibration amplitude Our work has demonstrated the important processing strategies on how to tailor the particle size while ensuring consistent particle shape and morphology, which is the key processing capability for producing high quality powders for additive manufacturing applications.

36 MATERIALS SCIENCE↗

Effects of ultrasonic processing on phase transition of flame-synthesized anatase TiO{sub 2} nanoparticles

The effect of ultrasonic processing on the phase transformation of flame-synthesized anatase TiO{sub 2} nanoparticles heated to the rutile phase was investigated. TiO{sub 2} nanoparticles of various sizes were prepared using a coflow hydrogen diffusion flame and an ultrasonic processor. Smaller nanoparticles having a similar portion of anatase phase using the ultrasonic processor were produced. On the basis of scanning electron microscopy images and specific surface areas, we observed that smaller nanoparticles tended to be sintered more easily than larger nanoparticles. From X-ray diffraction analysis, we demonstrated that when heated, TiO{sub 2} nanoparticles synthesized using the ultrasonic processor at 60% of its maximum amplitude were transformed from the anatase phase to the rutile phase more easily than those formed without or with the ultrasonic processor operated at 20% of its maximum amplitude.

36 MATERIALS SCIENCE↗