Search NASA⌕ Search

SEARCH · Search NASA

Results for “UNDERGROUND STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Temporal Variability of Emissions Revealed by Continuous, Long-Term Monitoring of an Underground Natural Gas Storage Facility

Temporal variability contributes to uncertainty in inventories of methane emissions from the natural gas supply chain. Extrapolation of instantaneous, “snapshot-in-time” measurements, for example, can miss temporal intermittency and confound bottom-up/top-down comparisons. Importantly, no continuous long-term datasets record emission variability from underground natural gas storage facilities despite substantial contributions to sector-wide emissions. We present 11 months of continuous observations on a section of a storage site using dual-frequency comb spectroscopy (DCS observing system) and aircraft measurements. Here, we find high emission variability and a skewed distribution in which the 10% highest 3 h emission periods observed by the continuous DCS observing system comprise 41% of the total observed 3-hourly emissions. Monthly emission rates differ by >12×, and 3-hourly rates vary by 17× in 24 h. We find links to the operating phase of the facility—emission rates, including as a percentage of the total gas flow rate, are significantly higher during periods of injection compared to those of withdrawal. We find that if a high frequency of aircraft flights can occur, then the ground- and aircraft-based approaches show excellent agreement in emission distributions. A better understanding of emission variability at underground natural gas storage sites will improve inventories and models of methane emissions and clarify pathways toward mitigation.

54 ENVIRONMENTAL SCIENCES↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Hydrogen storage and geo-methanation in a depleted underground hydrocarbon reservoir

Coupling of power-to-gas processes with underground gas storage could effectively allow surplus electricity to be stored for later use. Depleted hydrocarbon reservoirs could be used as stores, but practical experience of hydrogen storage in such sites is limited. Here we present data from a field trial that stored 119,353 m 3 of hydrogen admixed to natural gas in a depleted hydrocarbon reservoir. After 285 days, hydrogen recovery was 84.3%, indicating the process’s technical feasibility. Additionally, we report that microbes mediated hydrogen conversion to methane. In laboratory experiments studying mesocosms that mimic real reservoirs, hydrogen and carbon dioxide were converted to methane (0.26 mmol l —1 h —1 evolution rate) reproducibly over 14 cycles in 357 days. This rate theoretically allows 114,648 m 3 of methane per year to be produced in the test reservoir (equivalent to ~1.08 GWh). Our research demonstrates the efficiency of hydrogen storage and the importance of geo-methanation in depleted hydrocarbon reservoirs.

08 HYDROGEN↗

Identifying Potential Geochemical and Microbial Impacts of Hydrogen Storage in a Deep Saline Aquifer

Hydrogen is valuable commodity and a promising energy carrier for variable energy production. Storage of hydrogen may occur through injection of hydrogen or a hydrogen/methane gas blend in subsurface reservoirs. However, the geochemical and biological reactions that may impact the stored hydrogen are not yet understood. Therefore, we collected samples from a deep storage aquifer located in the St. Peter Formation in southern Illinois. The reservoir material was primarily quartz with sulphur and iron deposits, while the major constituents of the fluid were chloride and sulphate. 16S rRNA gene amplicon sequencing revealed a low biomass microbial community that contained no obvious hydrogen-consuming bacteria. Next, we enriched a field sample to increase the biomass and completed a metagenomic analysis, finding a low number of genes present that are associated with hydrogen consumption. Then, we completed a series of reactor experiments under reservoir conditions with 15% H2/85% CH4 gas simulating a short-term hydrogen storage, high withdrawal scenario. We found minimal changes in the geochemistry or microbiology for the reactor experiments. This work suggests that short-term storage may be highly successful, although significant additional work needs to be completed in order to accurately evaluate the risks associated with long-term hydrogen storage scenarios. It is essential we continue to expand our understanding of the dynamics present in saline aquifers and provide new insights into how hydrogen storage may impact underground geological storage environments.

54 ENVIRONMENTAL SCIENCES↗

Roles of kaolinite-oil-gas molecular interactions in hydrogen storage within depleted reservoirs

Hydrogen is a clean alternative to fossil fuels, emitting only water vapor during combustion. In a future hydrogen economy, large-scale storage will be an important component of the supply chain. Due to its low volumetric density, conventional surface storage methods are inadequate. Underground hydrogen storage (UHS) offers a viable solution, enabling the storage of millions of cubic meters. Among potential geological sites, including salt caverns, aquifers, and depleted gas reservoirs, depleted oil reservoirs show promise. Studying hydrogen interactions with residual oil and reservoir minerals is vital for understanding the properties of hydrogen and the reservoir post-injection. In this work, we employed molecular dynamics simulations to gain molecular-level insights into these interactions. We investigated hydrogen dissolution in oil, adsorption at kaolinite/oil interfaces, the role of CO 2 as a cushion gas, and the influence of kaolinite’s hydrophobicity on H 2 behavior. The main findings include: (1) hydrogen dissolves more in oil than in water, (2) the introduction of CO 2 suppresses hydrogen dissolution in oil and reduces the interfacial tension (IFT) between oil and gas, (3) CO 2 decreases H 2 partitioning near kaolinite surfaces due to its strong affinity for the hydrophilic gibbsite surface of kaolinite, and (4) CO 2 is more effective than H 2 in reducing IFT between kaolinite and the oil–gas mixture. These findings emphasize the effectiveness of CO 2 as a cushion gas and the important role of clay hydrophobicity in UHS, providing insights that are challenging to obtain experimentally.

08 HYDROGEN↗

Integrated Hydrogen Energy Storage System (IHESS) for Power Generation (Final Report)

GTI Energy partnered with Praxair Inc., a subsidiary of Linde PLC (Praxair), the Center for Electromechanics at the University of Texas at Austin (CEM), Entergy Corporation (Entergy), Quanta Services (Quanta) and Mitsubishi Heavy Industries (MHI) to perform a feasibility study that determines the economic and technical feasibility of low-carbon hydrogen energy storage integrated with a site-specific fossil fuel asset to decarbonize electricity production using the Integrated Hydrogen Energy Storage System (IHESS). The proposed IHESS concept is novel, as it sought to leverage the existing natural gas infrastructure, hydrogen production and pipelines, existing underground hydrogen storage system and power plants in the Gulf Coast region to reduce carbon emissions and generate lowcarbon electricity. This study has shown that IHESS has a promising commercial outlook as the concept leverages existing natural gas infrastructure assets and hydrogen production and storage that are unique to the Texas gulf coast region. A key hurdle with hydrogen supply and transportation has been capital investment. By storing hydrogen in underground storage and delivering it as a fuel source during peak demand using the existing infrastructure minimizes the capital investment. Regional petrochemical producers who are actively seeking opportunities to reduce costs and lower emissions should find the IHESS concept very appealing.

03 NATURAL GAS↗

Bulk Storage of Hydrogen

The technical aspects and economics of bulk hydrogen storage in underground pipes, lined rock caverns (LRC) and salt caverns are analyzed. Hydrogen storage in underground pipes is more economical than in geological caverns for useable amounts <20-t-H2. However, because the pipe material is a major cost factor, the capital and operating costs for this storage method do not decrease appreciably with an increase in the amount of stored H2. Unlike underground pipes, the installed capital cost of salt caverns decreases appreciably from ~$95/kg-H2 at 100 t-H2 stored to <$19/kg-H2 at 3000 t-H2 stored. Over the same scale, the annual storage cost decreases from ~$17/kg-H2 to ~$3/kg-H2. Like salt caverns, the installed capital cost of lined rock caverns decreases from ~$160/kg-H2 at 100 t-H2 stored to <$44/kg-H2 at 3000 t-H2 stored. Storing >750-t useable H2 requires multiple caverns. The cost of salt caverns scales more favorably with size because the salt caverns are larger than lined rock caverns and need to be added at a slower rate as the storage capacity is increased.

Bulk storage of hydrogen↗

Local-Scale Framework for Techno-Economic Analysis of Subsurface Hydrogen Storage

The energy sector is evolving toward increased reliance on renewable energy technologies to meet state, national, and organization decarbonization goals. This trend is creating challenges and opportunities with meeting current and future energy demand under the variable supply conditions that most renewables provide. Hydrogen (H 2 ) is a promising energy carrier that may meet the need for both on-demand and long-duration storage to maintain energy security and resilience. Underground hydrogen storage (UHS) is a method of storing H 2 in subsurface geological systems, such as depleted hydrocarbon reservoirs, salt caverns, saline aquifers, hard rock, and other engineered systems. UHS has the potential to store large quantities of H 2 over time, providing a reliable source of energy while minimizing surface footprints at a lower investment cost compared to surface storage. Earlier work estimated that, if converted and retrofitted, existing underground natural gas storage (UGS) facilities in the U.S. can store approximately 327 TWh, or 9.8 million metric tons, of pure H 2 . However, a shift to pure H 2 would decrease the collective working-gas energy of the UGS facilities by approximately 75% due to physical and chemical differences between natural gas and hydrogen. The same work also suggests that almost 75% of the existing UGS facilities in the U.S. could maintain current energy demand buffering using a blend of only 20% H 2 to 80% natural gas, by volume at surface conditions. If we can take advantage of the suite of mature technologies of existing UGS facilities and natural gas utility systems to accelerate the transition to a hydrogen economy in the U.S., a 20% H 2 blend could lead to a 6-7% reduction of greenhouse gas emissions for energy delivered through natural gas utility systems.

03 NATURAL GAS↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsurface Hydrogen and Natural Gas Storage (State of Knowledge and Research Recommendations Report)

Global efforts to decrease carbon dioxide (CO 2 ) emissions will result in increased reliance on renewable energy sources. One of the most significant obstacles to implementing this transition is the need for energy storage to compensate for varying, and sometimes intermittent, production rates and ever-increasing demand. An attractive solution is to use surplus energy to produce hydrogen gas (H 2 ), which can then be used to produce energy on demand without emitting CO 2 . This approach would require a vast H 2 network linking generators with consumers via transmission systems. Additionally, H 2 storage would be needed to support immediate needs, but larger storage reserves also will be required to ensure energy reliability and mitigate the impact of the mismatch between variable production rates and demand. Large-scale storage of H 2 may be achieved by using underground resources similar to how natural gas (NG) has been stored for the past century. While there is much experience in underground NG storage (UGS), significant technical challenges must be addressed to economically and safely store H 2 at the commercial scale. The purpose of this report is to assess the current state of knowledge and to identify technical research needs to facilitate deployment of large-scale underground hydrogen storage (UHS).

03 NATURAL GAS↗

H2 Sensing with an Optical Fiber Sensor in the Subsurface H2 Storage Conditions

The concentration of hydrogen is subject to change due to biological reactions in the underground hydrogen storage reservoirs. Thus, monitoring hydrogen concentration in the subsurface gas deposits is vital to ensure the integrity and safety of the storage facilities. In this study, the optical fiber hydrogen sensor was developed and validated in relevant subsurface storage environments. Specifically, the sensor has demonstrated successful sensing performance at high temperatures (~80 °C) and high pressures (~1,000 psi) under very humid conditions (~100% RH). In addition, the sensor was exposed to real subsurface microbial samples to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity. The biotic subsurface sample with hydrogen gas resulted in higher transmission intensity change than the abiotic sample due to the possible hydrogen consumption with microbes.

Kim, Daejin↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗