Tutorial: Developmental highlights and present applications of cardiac ultrasound
Current applications of ultrasound for cardiac imaging are reviewed. Display methods and modes are discussed in detail. Instrumentation and limitations are summarized.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Current applications of ultrasound for cardiac imaging are reviewed. Display methods and modes are discussed in detail. Instrumentation and limitations are summarized.
A technique is introduced for the measurement of plantar soft tissue thickness during barefoot walking. Subjects stepped into an adjustable Plexiglas frame which ensured that the required bony landmarks were appropriately positioned relative to a linear ultrasound probe connected to a conventional 7.5 MHz ultrasound scanner. Clear images of the metatarsal condyles or other foot bones were obtained throughout ground contact. Subsequent analysis of the video taped images using a motion analysis system allowed the tissue displacement to be calculated as a function of time. The tissue underneath the second metatarsal head was shown to undergo an average maximum compression of 45.7% during the late stages of ground contact during first step gait in a group of five normal subjects with a mean unloaded tissue thickness of 15.2 mm. The technique has a number of applications, including use in the validation of deformation predicted by finite element models of the soft tissue of the foot, and the study of alterations in the cushioning properties of the heel by devices which constrain the displacement of the heel pad.
Successful performance of medical procedures during missions beyond low Earth orbit requires novel solutions to replace real-time support from the ground since the communication delay will be longer as the crew travels farther from Earth. The Autonomous Medical Officer Support software Technology Demonstration project (AMOS Tech Demo) on the International Space Station (ISS) evaluates a novel software tool that shifts the emphasis from preflight training and real-time guidance (current ISS paradigm) to in-flight just-in-time (JIT) instruction (a new paradigm for crew medical autonomy). The AMOS platform introduces a novel, streamlined, skill-management archetype for exploration missions; the current AMOS version features comprehensive training and guidance modules for urinary bladder and kidney ultrasound examinations. The primary goal of the AMOS Tech Demo was to confirm telemedical proof-of-concept through initial use of the platform for autonomous imaging activities in an operational setting. Success metrics encompassed 1) successful software deployment, 2) collection of click tracking data, and 3) recording of ultrasound images. Additional aims included collecting crew feedback on a) AMOS implementation, and b) integrated training and procedure support concepts, as well as c) evaluation of AMOS use in an operational setting.
The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.
The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.
An imaging system is described which can be used to either passively search for sources of ultrasonics or as an active phase imaging system. which can image fires. gas leaks, or air temperature gradients. This system uses an array of ultrasonic receivers coupled to an ultrasound collector or lens to provide an electronic image of the ultrasound intensity in a selected angular region of space. A system is described which includes a video camera to provide a visual reference to a region being examined for ultrasonic signals.
Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.
Intravenous microbubble oscillation in the presence of ultrasound has the potential to yield a wide range of therapeutic benefits. However, the likelihood of vessel damage caused by mechanical effects has not been quantified as a function of the numerous important parameters in therapeutic ultrasound procedures. In this study, we examined the effects of microbubbles injected into the vasculature of the earthworm. It was found that the elastic properties of earthworm blood vessels are similar to those of arteries in older humans, and that earthworms are well suited to the large number of experiments necessary to investigate safety of procedures involving microbubble oscillation in sonicated vessels. Microbubbles were infused into earthworm vessels, and the rupture time during sonication was recorded as a function of ultrasound frequency, pulse repetition frequency and acoustic pressure. A modified mechanical index (MMI) was defined that successfully captured the trends in rupture probability and rupture time for the different parameter values, creating a database of vessel rupture thresholds. In the absence of bubbles, the product of MMI squared and rupture time was approximately constant, indicating a possible radiation-force effect. Here, the MMI was an effective correlating parameter in the presence of bubbles, though the mathematical dependence is not yet apparent. The results of the study are expected to be valuable in designing more refined studies in vertebrate models, as well as informing computational models.
There are no nondestructive evaluation (NDE) tools capable of characterizing microscale damage throughout the thickness of concrete components, due to the multiphase, heterogeneous and multiscale nature of concrete. Ultrasound is only scattered by features at the same length scale, or smaller, than the wavelength of a wave’s dominant frequency. Successful imaging of microscale damage using ultrasound requires that the ultrasonic wavelength be on the order of a few millimeters (or smaller), yet the heterogeneous microstructure of concrete, with its fine and coarse aggregates, is on this same (and higher) micrometer/millimeter length scale, causing excessive ultrasonic wave scattering even in “good” concrete. The proposed solution applies non-collinear wave mixing to spatially image microscale damage, while still maintaining penetration through thick concrete components. This microscale imaging is possible by combining nonlinear wave mixing, with advanced phased array hardware and software to develop a breakthrough tool that will bring revolutionary changes in NDE of concrete infrastructure in terms of image resolution and depth of penetration. This work uses non-collinear wave mixing which exploits the physics that material nonlinearities such as microscale damage, cause interactions between two intersecting ultrasonic waves due to cross-mixing, which can lead to the generation of a third wave with a frequency and wave number of the sum or difference of the incident waves. The concrete material volume at this mixing point is characterized/imaged. This project delivered a single-sided nonlinear ultrasonic phased array imaging device, that can image microscale damage (microcracks of 100 micrometers) through a 0.5 m thick concrete component and assessed the commercial feasibility of such arrays for improved crack detection.
Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.
The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti‐lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post‐flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio‐ each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured
Hemorrhage is the leading cause of preventable death in both civilian and military medicine. Junctional hemorrhages are especially difficult to manage since traditional tourniquet placement is often not possible. Ultrasound can be used to visualize and guide the caretaker to apply pressure at physiological pressure points to stop hemorrhage. However, this process is technically challenging, requiring the vessel to be properly positioned over rigid boney surfaces and applying sufficient pressure to maintain proper occlusion. As a first step toward automating this life-saving intervention, we demonstrate an artificial intelligence algorithm that classifies a vessel as patent or occluded, which can guide a user to apply the appropriate pressure required to stop flow. Neural network models were trained using images captured from a custom tissue-mimicking phantom and an ex vivo swine model of the inguinal region, as pressure was applied using an ultrasound probe with and without color Doppler overlays. Using these images, we developed an image classification algorithm suitable for the determination of patency or occlusion in an ultrasound image containing color Doppler overlay. Separate AI models for both test platforms were able to accurately detect occlusion status in test-image sets to more than 93% accuracy. In conclusion, this methodology can be utilized for guiding and monitoring proper vessel occlusion, which, when combined with automated actuation and other AI models, can allow for automated junctional tourniquet application.
Recent advances in remotely guided imaging techniques on ISS allow the acquisition of high quality ultrasound data using crewmember operators with no medical background and minimal training. However, ongoing efforts are required to develop and validate methodology for complex imaging protocols to ensure their repeatability, efficiency, and suitability for use aboard the ISS. This Station Developmental Test Objective (SDTO) tests a cardiovascular evaluation methodology that takes advantage of the ISS Ultrasound capability, the Braslet-M device, and modified respiratory maneuvers (Valsalva and Mueller), to broaden the spectrum of anatomical and functional information on human cardiovascular system during long-duration space missions. The proposed methodology optimizes and combines new and previously demonstrated methods, and is expected to benefit medically indicated assessments, operational research protocols, and data collections for science. Braslet-M is a current Russian operational countermeasure that compresses the upper thigh to impede the venous return from lower extremities. The goal of the SDTO is to establish and validate a repeatable ultrasound-based methodology for the assessment of a number of cardiovascular criteria in microgravity. Braslet-M device is used as a means to acutely alter volume distribution while focused ultrasound measurements are performed. Modified respiratory maneuvers are done upon volume manipulations to record commensurate changes in anatomical and functional parameters. The overall cardiovascular effects of the Braslet-M device are not completely understood, and although not a primary objective of this SDTO, this effort will provide pilot data regarding the suitability of Braslet-M for its intended purpose, effects, and the indications for its use.
Most medical equipment on the International Space Station (ISS) is manifested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical situations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-operator during an exam to facilitate the diagnosis in a timely fashion. In this document, we strove to verify that the HRF ultrasound video output is compatible with the ISS video system, identify ISS video system field rates and resolutions that are acceptable for varying clinical scenaiios, and evaluate the HRF ultrasound video with a commercial, off-the-shelf video converter, and compare it with the ISS video system.
Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.
A method for plane-wave or fan-beam ultrasound tomography includes: controlling, by a processor, a multi-channel ultrasound array controller to control a linear ultrasound transducer array to emit plane-wave or fan-beam ultrasound into a biological tissue, the linear ultrasound transducer array including a plurality of transducers; receiving, by the processor, plane-wave or fan-beam ultrasound waveform data from the transducers, the plane-wave or fan-beam ultrasound waveform data including reflections of the plane-wave or fan-beam ultrasound from the biological tissue; computing, by the processor, a synthetic ultrasound-waveform inversion from the received plane-wave or fan-beam ultrasound waveform data; and computing, by the processor, an image of the biological tissue from the synthetic ultrasound-waveform inversion.
Thoracic ultrasound can provide information leading to rapid diagnosis of pneumothorax with improved accuracy over the standard physical examination and with higher sensitivity than anteroposterior chest radiography. However, the clinical We have Furthermore, remote environments, such as the battlefield or deep-space exploration, may lack expertise for diagnosing developed an automated image interpretation pipeline for the analysis of thoracic ultrasound data and the classification of pneumothorax events to provide decision support in such situations. Our pipeline consists of image preprocessing, data augmentation, and deep learning architectures for medical diagnosis. In this work, we demonstrate that robust, accurate interpretation of chest images and video can be achieved using deep neural networks. A number of novel image processing techniques were employed to achieve this result. Affine transformations were applied for data augmentation. Hyperparameters were optimized for learning rate, dropout regularization, batch size, and epoch iteration by a sequential model-based Bayesian approach. In addition, we utilized pretrained architecturesinterpretation of a patient medical image is highly operator dependent. certain pathologies., applying transfer learning and fine-tuning techniques to fully connected layers. Our pipeline yielded binary classification validation accuracies of 98.3% for M-mode images and 99.8% with B-mode video frames.
Ultrasound (US) capabilities have been part of the Human Research Facility (HRF) on board the International Space Station (ISS) since 2001. The US equipment on board the ISS includes a first-generation Tissue Harmonic Imaging (THI) option. Harmonic imaging (HI) is the second harmonic response of the tissue to the ultrasound beam and produces robust tissue detail and signal. Since this is a first-generation THI, there are inherent limitations in tissue penetration. As a breakthrough technology, HI extensively advanced the field of ultrasound. In cardiac applications, it drastically improves endocardial border detection and has become a common imaging modality. U.S. images were captured and stored as JPEG stills from the ISS video downlink. US images with and without harmonic imaging option were randomized and provided to volunteers without medical education or US skills for identification of endocardial border. The results were processed and analyzed using applicable statistical calculations. The measurements in US images using HI improved measurement consistency and reproducibility among observers when compared to fundamental imaging. HI has been embraced by the imaging community at large as it improves the quality and data validity of US studies, especially in difficult-to-image cases. Even with the limitations of the first generation THI, HI improved the quality and measurability of many of the downlinked images from the ISS and should be an option utilized with cardiac imaging on board the ISS in all future space missions.