Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

116 records · Page 7

A unique measurement technique to study laminar-separation bubble characteristics on an airfoil

A 'nonintrusive', multielement heat-transfer sensor was designed to study laminar-separation bubble characteristics on a NASA LRN (1)-1010 low-Reynolds number airfoil. The sensor consists of 30 individual nickel films, vacuum-deposited on a thin substrate (0.05 mm) that was bonded to the airfoil model with the sensor array placed streamwise on the airfoil upper surface. Experiments were conducted on a 15-cm chord model in the 50,000-300,000 chord Reynolds number range. Time history as well as spectral analysis of signals from surface film gauges were simultaneously obtained to determine the location of laminar separation and the subsequent behavior of the separated shear layer. In addition to the successful determination of laminar separation, a new phenomenon involving a large phase shift in dynamic shear stresses across the separation and reattachment points was observed.

Stack, J. P.↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Electrical Ground Support Equipment for the Sampling Caching System of the Mars 2020 Rover

In this work we describe in detail the architecture, design, testing and operation of the Electrical Ground Support Equipment (EGSE) “Blue Box” used to test and validate the Sampling Caching System (SCS) of the Mars 2020 Perseverance rover. The Blue Box architecture is centered around COTS motor controllers and COTS input-output modules communicating over an EtherCAT bus. A custom, low-level safety subsystem ensures no harm can be done to the flight articles. The modular architecture of the EGSE reduces cost and complexity while expediting assembly time. The Blue Box drives the 19 actuators of the SCS which span the main robotic arm, the corer system, the internal sample handling arm, the sample tube sealing system and the gas dust removal tool; mimicking the Rover Motor Control Assembly (RMCA). Due to the limited availability of RMCA’s, the EGSE enabled and performed the bulk of testing activities for SCS. The majority of the SCS actuators are composed of a 3-phase DC brushless motors, hall sensors for commutation, dual resolvers for output angular measurement, brakes, heaters and platinum thermistors. Additionally, the EGSE read 12 strain gauges forming part of a force torque sensor, and switches used for external positioning references. Over the 3-year span of the V&V campaign for the SCS, over 32 EGSE systems were built, tested and deployed to test venues at JPL and externally. The EGSE tested several families of the SCS subsystem, ranging from engineering units, life test units and two flight units. Test venues that this EGSE supported included lab benches, ultra-clean cleanrooms, ATLO facilities, and thermal vacuum chambers. Together with the test software systems, SSDEV and SSDEV-ECAT, the Blue Box EGSE enabled the team to efficiently test flight hardware and flight software together. We go over the safety features and fault management techniques employed to protect flight hardware. The effects of the long, 50-feet, EGSE harnesses on motor performance, EMI, electrical noise, and motor control performance are explained. Mitigations to these unwanted effects, including shielding strategy and inductance compensation, are summarized. We go over an excerpt of notable anomalies that this EGSE suffered through its operation, along with investigations and resolutions. Lessons learned, areas of improvement as part of future work, and recommendations for future implementations for similar EGSE’s, are shared.

Levine, Dan↗

Mass Flux of ZnSe by Physical Vapor Transport

Mass fluxes of ZnSe by physical vapor transport (PVT) were measured in the temperature range of 1050 to 1160 C using an in-situ dynamic technique. The starting materials were either baked out or distilled under vacuum to obtain near-congruently subliming compositions. Using an optical absorption technique Zn and Se, were found to be the dominant vapor species. Partial pressures of Zn and Se, over the starting materials at temperatures between 960 and 1140 C were obtained by measuring the optical densities of the vapor phase at the wavelengths of 2138, 3405, 3508, 3613, and 3792 A. The amount and composition of the residual gas inside the experimental ampoules were measured after the run using a total pressure gauge. For the first time, the experimentally determined partial pressures of Zn and Se, and the amount and composition of the residual gas were used in a one-dimensional diffusion limited analysis of the mass transport rates for a PVT system. Reasonable agreement between the experimental and theoretical results was observed.

Sha, Yi-Gao↗

Elevated Temperature, Notched Compression Performance of Out of Autoclave Processed Composites

Curved honeycomb sandwich panels composed of carbon fiber reinforced toughened-epoxy polymer facesheets are being evaluated for potential use as payload fairing components on the NASA heavy-lift space launch system (HL-SLS). These proposed composite sandwich panels provide the most efficient aerospace launch structures, and offer mass and thermal advantages when compared with existing metallic payload fairing structures. NASA and industry are investigating recently developed carbon fiber epoxy prepreg systems which can be fabricated using out-of autoclave (OOA) processes. Specifically, OOA processes using vacuum pressure in an oven and thereby significantly reducing the cost associated with manufacturing large (up to 10 m diameter) composite structures when compared with autoclave. One of these OOA composite material systems, CYCOM(R) 5320-1, was selected for manufacture of a 1/16th scale barrel portion of the payload fairing; such that, the system could be compared with the well-characterized prepreg system, CYCOM(R) 977-3, typically processed in an autoclave. Notched compression coupons for each material were obtained from the minimum-gauge flat laminate [60/-60/0]S witness panels produced in this manufacturing study. The coupons were also conditioned to an effective moisture equilibrium point and tested according to ASTM D6484M-09 at temperatures ranging from 25 C up to 177 C. The results of this elevated temperature mechanical characterization study demonstrate that, for thin coupons, the OHC strength of the OOA laminate was equivalent to the flight certified autoclave processed composite laminates; the limitations on the elevated temperature range are hot-wet conditions up to 163 C and are only within the margins of testing error. At 25 C, both the wet and dry OOA material coupons demonstrated greater OHC failure strengths than the autoclave processed material laminates. These results indicate a substantial improvement in OOA material development and processing since previous studies have consistently reported OOA material strengths on par or below those of autoclave processed composite laminates.

Grimsley, Brian W.↗

Technical Capability Upgrades to the NASA Langley Research Center 6 ft. by 6 ft. Thermal Vacuum Chamber

The 6 ft. by 6 ft. thermal vacuum chamber (TVAC), housed in Building 1250 at the NASA Langley Research Center (LaRC), and managed by the Systems Integration and Test Branch within the Engineering Directorate, has undergone several significant modifications to increase testing capability, safety, and quality of measurements of articles under environmental test. Significant modifications include: a new nitrogen thermal conditioning unit for controlling shroud temperatures from -150degC to +150degC; two horizontal auxiliary cold plates for independent temperature control from -150degC to +200degC; a suite of contamination monitoring sensors for outgassing measurements and species identification; signal and power feed-throughs; new pressure gauges; and a new data acquisition and control commanding system including safety interlocks. This presentation will provide a general overview of the LaRC 6 ft. by 6 ft. TVAC chamber, an overview of the new technical capabilities, and illustrate each upgrade in detail, in terms of mechanical design and predicted performance. Additionally, an overview of the scope of tests currently being performed in the chamber will be documented, and sensor plots from tests will be provided to show chamber temperature and pressure performance with actual flight hardware under test.

Thornblom, Mark N.↗

Spin Testing for Durability Began on a Self-Tuning Impact Damper for Turbomachinery Blades

NASA and Pratt & Whitney will collaborate under a Space Act Agreement to perform spin testing of the impact damper to verify damping effectiveness and durability. Pratt & Whitney will provide the turbine blade and damper hardware for the tests. NASA will provide the facility and perform the tests. Effectiveness and durability will be investigated during and after sustained sweeps of rotor speed through resonance. Tests of a platform wedge damper are also planned to compare its effectiveness with that of the impact damper. Results from baseline tests without dampers will be used to measure damping effectiveness. The self-tuning impact damper combines two damping methods-the tuned mass damper and the impact damper. It consists of a ball located within a cavity in the blade. This ball rolls back and forth on a spherical trough under centrifugal load (tuned mass damper) and can strike the walls of the cavity (impact damper). The ball s rolling natural frequency is proportional to the rotor speed and can be designed to follow an engine-order line (integer multiple of rotor speed). Aerodynamic forcing frequencies typically follow these engineorder lines, and a damper tuned to the engine order will most effectively reduce blade vibrations when the resonant frequency equals the engine-order forcing frequency. This damper has been tested in flat plates and turbine blades in the Dynamic Spin Facility. During testing, a pair of plates or blades rotates in vacuum. Excitation is provided by one of three methods--eddy-current engine-order excitation (ECE), electromechanical shakers, and magnetic bearing excitation. The eddy-current system consists of magnets located circumferentially around the rotor. As a blade passes a magnet, a force is imparted on the blade. The number of magnets used can be varied to change the desired engine order of the excitation. The magnets are remotely raised or lowered to change the magnitude of the force on the blades. The other two methods apply force to the rotating shaft itself at frequencies independent of the rotor speed. During testing, blade vibration is monitored with strain gauges and laser displacement probes.

Duffy, Kirsten↗

Ammonia Leak Locator Study

The thermal control system of International Space Station Alpha will use liquid ammonia as the heat exchange fluid. It is expected that small leaks (of the order perhaps of one pound of ammonia per day) may develop in the lines transporting the ammonia to the various facilities as well as in the heat exchange equipment. Such leaks must be detected and located before the supply of ammonia becomes critically low. For that reason, NASA-JSC has a program underway to evaluate instruments that can detect and locate ultra-small concentrations of ammonia in a high vacuum environment. To be useful, the instrument must be portable and small enough that an astronaut can easily handle it during extravehicular activity. An additional complication in the design of the instrument is that the environment immediately surrounding ISSA will contain small concentrations of many other gases from venting of onboard experiments as well as from other kinds of leaks. These other vapors include water, cabin air, CO2, CO, argon, N2, and ethylene glycol. Altogether, this local environment might have a pressure of the order of 10(exp -7) to 10(exp -6) torr. Southwest Research Institute (SwRI) was contracted by NASA-JSC to provide support to NASA-JSC and its prime contractors in evaluating ammonia-location instruments and to make a preliminary trade study of the advantages and limitations of potential instruments. The present effort builds upon an earlier SwRI study to evaluate ammonia leak detection instruments [Jolly and Deffenbaugh]. The objectives of the present effort include: (1) Estimate the characteristics of representative ammonia leaks; (2) Evaluate the baseline instrument in the light of the estimated ammonia leak characteristics; (3) Propose alternative instrument concepts; and (4) Conduct a trade study of the proposed alternative concepts and recommend promising instruments. The baseline leak-location instrument selected by NASA-JSC was an ion gauge.

Dodge, Franklin T.↗