Estimating Snow Sublimation in Complex Terrain: A Season of Intensive Field Measurements and the Role of Vertical Water Vapor Flux Divergence
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Meso-porous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed or optimized for this purpose. This project will use molecular dynamic simulations to determine optimal membrane properties for these air conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Optimal membrane designs will enable smaller, more durable, and less expensive designs of these membrane air conditioning systems.
Explore the source record for details and available documents.
The purpose of this study was to look at the thermodynamic and microphysical evolution the atmosphere during fog events at Summit. These cases were selected due to the presence of fog during a period when additional aerosol sensors where deployed on the colocated tower.
Explore the source record for details and available documents.
Operating temperatures above 700°C are desired to improve the efficiency of power generation systems such as microturbines. Therefore, the use of creep-resistant Ni-based or Fe-based alloys, which can form protective Cr2O3 and Al2O3 scales, is required. In this paper, Fe- and Ni-based alloy foils were oxidized in air + 10 % H2O for up to 3,000 h at 850°C to identify the most promising alloys. The thickness and chemical composition of the spinel oxide formed on top of the Cr2O3 scale varied between S3100, N08120 and N06230 alloy foils. In addition, the rate of Cr and Mn loss (spinel and Cr2O3 oxidation and volatilization) or Al loss (oxidation) and the dissolution of strengthening precipitates, were found to be a function of the nature of the formed oxide (Fe or Ni-rich spinel, Cr2O3, Al2O3). Alloys N06230 and alumina-forming austenitic (AFA) steels were found to be well-suited for the applications as microturbine recuperator foil materials up to 850°C.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This is Ojuolape Oghenetega's PhD thesis that she worked on under a SUPN at Georgia Tech affiliated with my LDRD.
This project undertook an effort to experimentally demonstrate the ability to change the water content of an air volume through electrostatic, non-condensing means. Humid air is primarily a mixture of nitrogen, oxygen, argon, carbon dioxide and water vapor. Water is unique in this mixture because it possesses a relatively strong natural dipole moment. The physics of electrophoresis offers promise that electrostatic forces could be used to compel movement of water molecules, while leaving the other air components un-affected, which could be exploited to cause a concentration gradient of water within an air-stream.
Renewable organic precursors, including olefinic compounds such as isoprene, have attracted interest from the polymer and pharmaceutical industries. Biologically-derived processes can generate these target compounds; however, their gaseous product streams are complex mixtures of condensable organic vapors (COVs), water vapor, carbon dioxide (CO 2 ), and/or nitrogen (N 2 ). Because COVs, CO 2 and water vapor are known to alter polymer membranes, mixed gas separations data at ambient and elevated temperatures are limited. Here, this study focused on two classes of polymer membranes, glassy [polyetherimide (Ultem®)] and a rubbery [polydimethylsiloxane (PDMS)] with results indicating that isoprene separation is possible in humidified gas environment (2–4 vol% water). Gas permeabilities of these membranes did not noticeably change in the presence of humidity; however, the selectivity of these membranes was significantly lower compared to their performance under dry conditions. The role of water vapor in gas transport was derived from the energy of activation of permeation (E p ) for PDMS and Ultem® from 30–80°C in humidified mixed gas streams. For both polymers, E p data shows a slight decrease in selectivity with the other gases (hydrogen, N 2 , CO 2 , and methane) at elevated temperatures in the presence of water vapor. Thus, these COVs separations are feasible with polymer membranes in the presence of humidified gas streams, even in the case of glassy and rubbery membranes in series.
Abstract The transport of water through nanoscale capillaries/pores plays a prominent role in biology, ionic/molecular separations, water treatment and protective applications. However, the mechanisms of water and vapor transport through nanoscale confinements remain to be fully understood. Angstrom-scale pores (~2.8–6.6 Å) introduced into the atomically thin graphene lattice represent ideal model systems to probe water transport at the molecular-length scale with short pores (aspect ratio ~1–1.9) i.e., pore diameters approach the pore length (~3.4 Å) at the theoretical limit of material thickness. Here, we report on orders of magnitude differences (~80×) between transport of water vapor (~44.2–52.4 g m −2 day −1 Pa −1 ) and liquid water (0.6–2 g m −2 day −1 Pa −1 ) through nanopores (~2.8–6.6 Å in diameter) in monolayer graphene and rationalize this difference via a flow resistance model in which liquid water permeation occurs near the continuum regime whereas water vapor transport occurs in the free molecular flow regime. We demonstrate centimeter-scale atomically thin graphene membranes with up to an order of magnitude higher water vapor transport rate (~5.4–6.1 × 10 4 g m −2 day −1 ) than most commercially available ultra-breathable protective materials while effectively blocking even sub-nanometer (>0.66 nm) model ions/molecules.
Cloud liquid water path and precipitable water vapor (PWV) [also know as column water vapor or water vapor path] derived based on passive microwave radiometer measurements and a physical-iterative retrieval approach.
The afternoon-to-evening transition is the period when the atmospheric boundary layer transitions from convective to stable conditions. One noticeable feature during this transition period is the rapid increase in water vapor concentration near the surface. However, the mechanism behind the increase in water vapor remains poorly understood. This study investigated the processes contributing to the water vapor increase and the impacts of the land cover and horizontal advection on the water vapor increase using a single-column model for the clear-sky condition. Numerical experiments were conducted on three cases at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site. Evapotranspiration was found to be the main moisture source to the water vapor increase, and that change of the near-surface vertical temperature gradient from negative to positive is the trigger for this increase during the afternoon-to-evening transition. This is because the near-surface turbulence divergence term decreases due to the change in the buoyancy profile caused by vertical temperature gradient change. The impact of horizontal advection on water vapor varies, and it can either lead to an increase or a decrease in water vapor, depending on the spatial horizontal water vapor gradient. This study also found that land cover can influence the timing of the water vapor increase since different land covers may have different Bowen ratios. Water vapor increases earlier under conditions with smaller Bowen ratios compared to those with larger values.
The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.
Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.
Dropwise condensation is well known to result in better heat transfer performance owing to efficient condensate/droplet removal, which can be harnessed in various industrial heat/mass transfer applications such as power generation and conversion, water harvesting/desalination, and electronics thermal management. The key to enhancing condensation via the dropwise mode is thin low surface energy coatings (<100 nm) with low contact angle hysteresis. Ultrathin (<5 nm) silane self-assembled monolayers (or SAMs) have been widely studied to promote dropwise condensation due to their minimal thermal resistance and scalable integration processes. Such thin coatings typically degrade within an hour during condensation of water vapor. After coating failure, water vapor condensation transitions to the inefficient filmwise mode with poor heat transfer performance. We enhance silane SAM quality and durability during water vapor condensation on copper compared to state-of-the-art silane coatings on metal surfaces. We achieve this via (i) surface polishing to sub-10 nm levels, (ii) pure oxygen plasma surface treatment, and (iii) silane coating integration with the copper substrate in an anhydrous/moisture-free environment. The resulting silane SAM has low contact angle hysteresis (≈20°) and promotes efficient dropwise condensation of water for >360 hours without any visible sign of coating failure/degradation in the absence of non-condensable gases. We further demonstrate enhanced heat transfer performance (≈5-7× increase over filmwise condensation) over an extended period of time. Surface characterization data post-condensation leads us to propose that in the absence of non-condensable gases in the vapor environment, the silane SAM degrades due to reduction and subsequent dissolution of copper oxide at the oligomer-substrate interface. The experiments also indicate that the magnitude of surface subcooling (or condensation rate) affects the rate of coating degradation. Finally, this work identifies a pathway to durable dropwise promoter coatings that will enable efficient heat transfer in industrial applications.