Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Aircraft- and tower-based fluxes of carbon dioxide, latent, and sensible heat

Fluxes of carbon dioxide, water vapor, and sensible heat obtained over a grassland ecosystem, during the First International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE), using an aircraft- and two tower-based systems are compared for several days in 1987 and in 1989. The tower-based cospectral estimates of CO2, sensible heat, water vapor, and momentum, expressed as a function of wavenumber K times sampling height z, are relatively similar to the aircraft-based estimates for K x z greater than 0.1. A measurable contribution to the fluxes is observed by tower-based systems at K x z less than 0.01 but not by the aircraft-based system operating at an altitude of approximately 100 m over a 15 x 15 km area. Using all available simultaneous aircraft and tower data, flux estimates by both systems were shown to be highly correlated. As expected from the spatial variations of the greenness index, surface extrapolation of airborne flux estimates tended to lie between those of the two tower sites. The average fluxes obtained, on July 11, 1987, and August 4, 1989, by flying a grid pattern over the FIFE site agreed with the two tower data sets for CO2, but sensible and latent heat were smaller than those obtained by the tower-based systems. However, in general, except for a small underestimation due to the long wavelength contributions and due to flux divergence with height, the differences between the aircraft- and tower-based surface estimates of fluxes appear to be mainly attributable to differences in footprint, that is, differences in the area contributing to the surface flux estimates.

Desjardins, R. L.↗

Elemental Fractionation During Rapid Accretion of the Moon Triggered by a Giant Impact

Recently, Ida et al. made an N-body simulation of lunar accretion from a protolunar disk formed by a giant impact. One of their important conclusions is that the accretion time of the Moon is as short as one month. Such rapid accretion is a necessary consequence of the high surface density of a lunar mass disk accreting just beyond the Roche limit (about 3Re); the Safronov accretion time (a few days) is even shorter. The energy of accretion always exceeds the gravitational binding energy of newly arriving matter. Hence, without an energy sink, the accreting body is thermally unstable. For the Earth and other planets, radiation acts as the sink. However, in such a short accretion time, the Moon cannot radiate the accretional energy. Even radiating at a silicate cloudtop temperature of roughly 2000 K, it would take more than 100 yr to radiatively cool the Moon. The plausible alternative heat sinks are heat capacity, latent heat of vaporization, and thermal escape of the gas to space (i.e., hydrodynamic blowoff). The latter becomes plausible for the Moon because the scale height at 2000 K (about 300 km) is a significant fraction of the lunar radius. The early stages of lunar (or "lunatesimal") growth release relatively little energy and can occur simply by heating the material, especially if the accreting material is originally cold. However, the material is unlikely to be cold, because the disk itself is hot and cooling time is long, while the lunar accretion time iss very short. Therefore, the moon is likely to accrete condensed material just after it condenses. Accordingly, the newly accreted material will be on the verge of vaporization and will have very little heat capacity to spare. The immediate heat sink is the latent heat of vaporization. Most of the vapor will escape from the moon, because the thermal energy in the gas can be used to drive escape. However, vaporization is generally incomplete. the latent heat of vaporization exceeds the energy of accretion. Viewed globally, the accretional energy is about half the energy required to vaporize the entire Moon. Thus to first approximation, half of the Moon-forming material can be vaporized and lost during accretion. During this process, we would expect preferential loss of relatively volatile elements. Escape will retard the rate of accretion. To test these ideas, we computed detailed models of the thermal state of the Moon during accretion. We pay special attention to the structure of the silicate atmosphere and its loss rate by calculating the chemical species at equilibrium. We used the PHEQ program which includes 12 elements (H,O,C,Mg,Si,Fe,Ca, Al, Na,Ti, and N.) and 272 compounds (including ionic compounds). Because of the large heats of vaporization and ionization, the adiabatic atmosphere is nearly isothermal and massive escape is expected. The pressure of the atmosphere is determined by the balance between vaporization of a accreting material and escape. If the accretion time is one month, a 0.3 bar atmosphere is expected. Elemental fractionation depends strongly on the temperature of the accreting material. The initial temperature of the material can be estimated from the condition of gravitational instability in the protolunar disk. As shown by Ida et al, accretion starts when gravitational instability occurs when more than 99% of the material condenses. At this point, all of Ca, Al, Si, Mg, and Fe, and 95% of Na (probably K also), are in condensed phases. If the moon is formed from the accretion of such material, volatile elements such as Na, and K are retained by the moon only early in accretion. At later times, K and Na are lost and a fraction of the MG, Si and Fe is lost. However, refractory elements such as Ca and Al are retained and so achieve a mild degree (factor 2) of superabundance.

Abe, Y.↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

Free-spray characteristics and spray-wall interactions of methanol on a gasoline direct injector under flash-boiling and non-flash-boiling conditions

Methanol is considered a promising alternative fuel for internal combustion engines (ICEs) due to its high-octane number, fast laminar flame speed, and elevated latent heat of vaporization, all of which support higher compression ratios and improved thermal efficiency. However, its substantial latent heat of vaporization also poses cold-start challenges, such as misfire and fuel film deposition. This study aims to investigate methanol spray morphology and spray-wall interaction using the Spray M injector from the Engine Combustion Network within a constant-pressure flow vessel. A recently developed unified numerical framework capable of modeling both flash and non-flash boiling sprays is validated against experimental liquid volume fraction data acquired via 3-D computed tomography. Here, the results reveal that flash boiling significantly alters the spray morphology, leading to smaller droplets and spray collapse due to enhanced air-entrainment-induced turbulence. Quantitative agreement between experiments and simulations confirms this behavior. Coupled 0-D equilibrium and 3-D computational fluid dynamics analyses show that flash boiling accelerates evaporation and reduces fuel residence time, while non-flash conditions maintain a persistent liquid core more susceptible to wall wetting. Wall temperature diagnostics reveal that spray collapse alters heat transfer patterns by shifting cooling effects. Mixture fraction analysis indicates that evaporation is primarily governed by shear-layer turbulence, though deviations from adiabatic equilibrium mixing emerge under low-turbulence conditions. Finally, increasing fuel, ambient, and wall temperatures reduces wall wetting and film thickness, mitigating cold-start risks. These findings enhance the understanding of methanol sprays’ behavior and support its adoption as a viable, alternative fuel for ICEs.

Engine Combustion Network↗

Sensitivity of magnetohydrodynamic simulations of Joule-heated conductors to the vaporization curve in equations of state

Magnetohydrodynamic (MHD) simulations of electrically exploded aluminum and copper rods demonstrate a technique to validate equations of state (EOS) for rapidly Joule-heated conductors. The balance of internal and magnetic forces at the conductor-insulator interface drives the metal there along the vaporization phase boundary. Variations between critical points and vaporization curves in existing models predict differing densities and temperatures in MHD simulations for these models. Here, the inclusion of Maxwell constructs in the liquid-vapor biphase region of the EOS caused the rod surface to vaporize earlier in time than unmodified tables with van der Waals loops. Velocimetry of recent experiments is used to validate the location of the vaporization curve in existing EOS models and differentiate between the vapor dome treatments. Dielectric coatings applied to the metal surface restricted the conductor’s expansion and diverted the metal into the warm dense matter regime.

36 MATERIALS SCIENCE↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill process to develop an analytical model of No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing stage, but then becomes less significant.

Chato, David J.↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing state, but then becomes less significant.

Chato, David J.↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Thermal study of interface between the Orbiter cold plate and typical Shuttle spacecraft payload flight electronics

Spacelab provides a set of Freon line plumbing and cold plates for experiment equipments which are located in the Shuttle pallet and which need active thermal control. The reported study deals with the thermal problem of attaching a Command and Data Handling module with various electronic boxes whose combined footprints on the baseplate are much larger than the cold plate. A description of two modules and the cold plate assembly in the pallet is presented and a thermal model description is provided. The method employed in modeling heat pipes-honey-comb matrix is based upon an effective conductance between the heat pipe vapor and the walls of the heat pipe. The considered thermal models and a computer program are used to perform steady-state thermal analyses. The temperature gradients in the large module baseplate attached to the small cold plate are predicted as a function of the interface plate thickness.

Hwangbo, H.↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83% by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/sq m). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 C, respectively. The boiling process during the entire heating period, as well as the jet-induced mixing process for the first 2 min of the mixing period, was also recorded on video. The unique features of the experimental results are the sustainability of high liquid superheats for long periods and the occurrence of explosive boiling at low heat fluxes (0.86 to 1.1 kW/sq m). For a heat flux of 0.97 kW/sq m, a wall superheat of 17.9 C was attained in 10 min of heating. This superheat was followed by an explosive boiling accompanied by a pressure spike of about 38% of the tank pressure at the inception of boiling. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Steady nucleate boiling continued after the explosive boiling. The jet-induced fluid mixing results were obtained for jet Reynolds numbers of 1900 to 8000 and Weber numbers of 0.2 to 6.5. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number.

Hasan, Mohammad M.↗

Thermal Technology Development Activities at the Goddard Space Flight Center: 2001

Activities include the development of two phase systems which are composed of 1) heat pipes and variable conductance heat pipes, 2)capillary pumped loops, 3) loop heat pipes, 4) vapor compression systems (heat pumps), 5) phase change materials. Also in the development phase are variable emittance surfaces, advanced coatings, high conductivity materials, and electrohydrodynamic (EHD) thermal control systems.

Butler, Dan↗

Cloud-Radiative Driving of the Madden-Julian Oscillation as Seen by the A-Train

Cloud and water vapor radiative heating anomalies associated with convection may be an effective source of moist static energy driving the Madden-Julian Oscillation (MJO). In this paper five years of radiative heating profiles derived from CloudSat radar and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation data are analyzed to document radiative heating anomalies during the MJO. Atmospheric shortwave absorption and surface longwave radiation anomalies are of opposite sign and 10-20% as large as top-of-atmosphere outgoing longwave radiation (OLR) anomalies, confirming that OLR provides a useful estimate of the total column radiative heating anomaly. Positive anomalies generally peak about one week before the MJO peak and are smallest over the Indian Ocean. Anomalies over the Maritime Continent are strongest, and coincident with the MJO peak. Shortwave heating profile anomalies are about half as large as longwave anomalies in the active region of the MJO but generally of opposite sign; thus shortwave heating damps the longwave destabilization of the lower troposphere. The exception is the onset phase of the MJO, where shortwave and longwave heating anomalies due to thin cirrus are both positive in the upper troposphere and exert a stabilizing influence. Specific humidity anomalies in the middle troposphere reach 0.5 g kg(exp. -1), but the associated clear sky heating anomaly is very small. Radiative enhancement of column moist static energy becomes significant about 10 days before the MJO peak, when precipitation anomalies are still increasing, and then remains high after the MJO peak after precipitation has begun to decline.

symbols↗

Experimental determination of ablation vapor species from carbon phenolic heat-shield materials

The relative concentrations of vapors produced from carbon phenolic composites under thermal loadings approximating those expected at peak heating during vehicle entry into the atmospheres of the outer planets have been determined. The technique of vaporizing the surface of bulk samples by laser irradiation while measuring in situ the vapor species by mass spectrometry is described. Results show that vapor composition varies with irradiance level and with depth of heating (or extent of pyrolysis). Attempts are made to compare these experimental results with the theoretical predictions from computer codes.

Lincoln, K. A.↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multistation refrigeration system

A closed cycle refrigeration (CCR) system is disclosed for providing cooling at different parts of a maser. The CCR includes a first station for cooling the maser's parts, except the amplifier portion, to 4.5 K. The CCR further includes means with a 3.0 K station for cooling the maser's amplifier to 3.0 K and, thereby, increases the maser's gain and/or bandwith by a significant factor. The means which provide the 3.0 K cooling include a pressure regulator, heat exchangers, an expansion valve, and a vacuum pump, which coact to cause helium, provided from a compressor, to liquefy and thereafter expand so as to vaporize. The heat of vaporization for the helium is provided by the maser amplifier, which is thereby cooled to 3.0 K.

Wiebe, E. R.↗

Simulation of the early startup period of high-temperature heat pipes from the frozen state by a rarefied vapor self-diffusion model

The heat pipe startup process is described physically and is divided into five periods for convenience of analysis. The literature survey revealed that none of the previous attempts to simulate the heat pipe startup process numerically were successful, since the rarefied vapor flow in the heat pipe was not considered. Therefore, a rarefied vapor self-diffusion model is proposed, and the early startup periods, in which the rarefied vapor flow is dominant within the heat pipe, are first simulated numerically. The numerical results show that large vapor density gradients existed along the heat pipe length, and the vapor flow reaches supersonic velocities when the density is extremely low. The numerical results are compared with the experimental data of the early startup period with good agreement.

Cao, Y.↗

Gas-evaporation in low-gravity field (cogelation mechanism of metal vapors) (M-14)

When metal and alloy compounds are heated and vaporized in a rare gas such as helium, argon, or xenon, the vaporized substances diffused in the rare gas are supersaturated resulting in a smoke of fine particles of the material congealing as snow or fog. The gas vaporizing method is a fine particle generation method. Though the method has a variety of applications, the material vapor flow is disturbed by gravitational convection on Earth. The inability to elucidate the fine particle generation mechanism results in an obstruction to improving the method to mass production levels. As no convection occurs in microgravity in space, the fine particle generation mechanism influenced only by diffusion can be investigated. Investigators expect that excellent particles with homogeneous diameter distribution can be obtained. Experiment data and facts will assist in improving efficiency, quality, and scale or production processes including element processes such as vaporization, diffusion, and condensation. The objective of this experiment is to obtain important information related to the mechanism of particle formation in the gas atmosphere (smoke particles) and the production of submicron powders of extremely uniform size.

Wada, N.↗