Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fundamental study on mitigation of rocking motion of a cask system by a gyro system

In Japan, ensuring the structural integrity of cask systems during seismic events is becoming increasingly important. Cask systems, which are free-standing cylindrical structures that contain spent fuel assemblies, are believed to exhibit rocking motions under strong seismic excitations. Thus far, analytical studies conducted by the authors have indicated that cask systems subjected to strong seismic motions, undergo large rocking motions, and, in the worst case, may overturn and collapse. Therefore, reducing the rocking motions of casks to avoid overturning and consequent contamination of radioactive substances is critical. To suppress rocking motions for heavy free-standing structures such as cask systems, we propose a rocking motion suppression system that employs a gyro system. This system is installed in the free-standing structure. A previous analytical study showed that this system largely mitigates rocking motion. In the present study, we fabricated a fundamental cask system model and a gyro system. By using the cask system model without a gyro system, free vibration tests and shaking table tests were conducted to understand the basic characteristics of rocking motion and responses under base excitations. Analyses were also conducted to confirm the validity of the analytical model for rocking motion comparing with the experimental data. Moreover, analyses for the cask system with the gyro system were conducted. From these results, we evaluated the ability of the gyro system to mitigate rocking motion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain

Modern electro-optical instruments are typically designed with assemblies of optomechanical members that support optics such that alignment is maintained in service environments that include random vibration loads. This paper presents a nonlinear numerical analysis that calculates statistics for the peak lateral response of optics in an optomechanical sub-assembly subject to random excitation of the housing. The work is unique in that the prior art does not address peak response probability distribution for stationary random vibration in the time domain for a common lens-retainer-housing system with Coulomb damping. Analytical results are validated by using displacement response data from random vibration testing of representative prototype sub-assemblies. A comparison of predictions to experimental results yields reasonable agreement. The Type I Asymptotic form provides the cumulative distribution function for peak response probabilities. Probabilities are calculated for actual lens centration tolerances. The probability that peak response will not exceed the centration tolerance is greater than 80% for prototype configurations where the tolerance is high (on the order of 30 micrometers). Conversely, the probability is low for those where the tolerance is less than 20 micrometers. The analysis suggests a design paradigm based on the influence of lateral stiffness on the magnitude of the response.

Palmer, Jeremy A.↗

Creating a Vibration Data Visualization and Analysis Graphical User Interface in Matlab [Poster]

Vibration testing in W-14 results in large amounts of data that need to be preprocessed before being used in reports or for model verification. It can take a large amount of time to accomplish simple, repetitive tasks on many channels of data. A Graphical User Interface (GUI) streamlines visualization and simple processing of the data to make the process faster as well as more intuitive. Simple editing methods, such as data segmentation and axis conversion, put the data in a form that can be easily moved into a more advanced modal analysis or data plotting package.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Source identification in acoustics and structural mechanics using Sierra/SD.

In this report we derive both time and frequency-domain methods for inverse identification of sources in elastodynamics and acoustics. The inverse/design problem is cast in a PDE-constrained optimization framework with efficient computation of gradients using the adjoint method. The implementation of source inversion in Sierra/SD is described, and results from both time and frequency domain source inversion are compared to actual experimental data for a weapon store used in captive carry on a military aircraft. The inverse methodology is advantageous in that it provides a method for creating ground based acoustic and vibration tests that can reduce the actual number of flight tests, and thus, saving costs and time for the program.

Walsh, Timothy Francis↗

Removal of Stationary Sinusoidal Noise from Random Vibration Signals

In random vibration environments, sinusoidal line noise may appear in the vibration signal and can affect analysis of the resulting data. We studied two methods which remove stationary sine tones from random noise: a matrix inversion algorithm and a chirp-z transform algorithm. In addition, we developed new methods to determine the frequency of the tonal noise. The results show that both of the removal methods can eliminate sine tones in prefabricated random vibration data when the sine-to-random ratio is at least 0.25. For smaller ratios down to 0.02 only the matrix inversion technique can remove the tones, but the metrics to evaluate its effectiveness also degrade. We also found that using fast Fourier transforms best identified the tonal noise, and determined that band-pass-filtering the signals prior to the process improved sine removal. When applied to actual vibration test data, the methods were not as effective at removing harmonic tones, which we believe to be a result of mixed-phase sinusoidal noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simcenter TestLab Error in uploading reference profiles

Our team exports data from Matlab to a Simcenter TestLab formatted .mat file. The .mat file is then uploaded as a reference profile for Environmental Random Control vibration testing. Operations are applied to the data before export that introduce floating point errors. We are experiencing errors uploading the generated reference profiles if the frequency values have a certain level of floating point error (1 Hz vs 1.000000000000001 Hz). I generated some test cases of reference profiles that were giving us trouble, and outlined the errors we were seeing. Two different errors, depending on how the control frequency range is defined. Error is fixed by copy/pasting the frequency column in the Profile Editor.

97 MATHEMATICS AND COMPUTING↗

Validation of the IMCE RFDA System for Dynamic Elastic Moduli Measurements

The focus of this report is to describe the new system that has been acquired for the Low Activation Material Development and Analysis Laboratory (LAMDA) to perform the measurement of the dynamic Young’s and shear moduli, and to show that the results of the new system are more easily analyzed and more accurate than the current systems. The current system is the GrindoSonic MK5 Impulse Excitation and Vibration Test System from J.W. Lemmens, Inc., and the new system is the Resonant Frequency and Damping Analyser (RFDA) from Integrated Material Control Engineering (IMCE). A comparison between the results from both systems was performed with nine specimen shapes and five graphite grades. All of the results showed agreement of the moduli values within 1-2%. The only outliers were a 20% disagreement for one specimen shape and a 5-10% disagreement for a second specimen shape, but it was shown that this occurred because the GrindoSonic system was reporting the frequency for the flexural harmonic peak rather than the fundamental torsional peak.

36 MATERIALS SCIENCE↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

Oxygenate Onboard Separation for Octane-on-Demand

This project further examines the use of Self-Assembled Monolayers on Mesoporous Supports ® SAMMS ® -based sorbent materials as a sorbent for alcohols from alcohol-gasoline blends in the context of an onboard separation approach for use in an octane-on-demand strategy. Several questions were posed by potential industry collaborators seeking to better understand how the SAMMS®-based materials would perform in a more realistic environment. Several conclusions can be made from the work conducted here, with the caveat that these experiments do not represent the results that would be obtained from continuous or long-term use of the sorbent, because of the short duration of the project. Vigorous extractions into warm gasoline did not reveal the presence of additional species in gas chromatographic analysis. Vibration testing for up to eight hours under aggressive conditions did not show particle attrition. Thermal desorption experiments showed that the SAMMS ® have a higher capacity for methanol, approximately 50 weight-percent of the sorbent, than for ethanol, approximately 20 weight-percent of the sorbent, and that the methanol is easier to extract. Testing of the A20 fuel blends was insufficient and requires a slightly more sophisticated approach than was attempted here. Additionally, further work would be needed to assess the rate at which the alcohol is absorbed into the sorbent. The testing conducted here suggests that equilibrium is reached in well under an hour. While this study provides additional insights into the use of SAMMS®-based sorbent materials for onboard alcohol separation, there is room for further work employing a benchtop testing apparatus similar to that described herein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of Shock, Vibration, and Other Tests for Type IV Hydrogen Composite Pressure Vessels for Rail Use

Requirements specific to hydrogen rail transportation and its unique components are currently not well represented in safety codes and standards. Notably, one of the most important components of the system, the hydrogen storage vessel, may be subject to entirely different shock and vibration conditions compared to hydrogen tanks on road vehicles. This report focuses on how composite hydrogen tanks are tested for performance and how this may relate to these tanks being used on rail systems. The shock and vibration testing procedures that are relevant for hydrogen composite tanks used for rail applications have been identified, as well as some general testing requirements for hydrogen tanks and composite tanks.

42 ENGINEERING↗

Lessons learned from CIRFT testing on SNF vibration integrity study

A cyclic integrated reversible-bending fatigue tester (CIRFT) was developed to support U.S. NRC and DOE Used Fuel Disposition Campaign studies on high burn-up (HBU) spent nuclear fuel (SNF) transportation during normal conditions of transport (NCT). Two devices were developed; the first CIRFT was successfully installed and operated in the ORNL hot-cells in September 2013. Since hot cell testing commenced several HBU SNF samples from both Zr-4 and M5 clads were investigated. The second CIRFT device was developed in February 2014, and has been used to test clad/fuel surrogate rods (stainless steel with alumina pellet inserts). The second CIRFT machine has also been used for sensor development and test sensitivity analyses, as well as loading boundary condition parameter studies. The lessons learned from CIRFT testing will be presented in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress Letter Report on Bending Fatigue Test System Development for Spent Nuclear Fuel Vibration Integrity Study (Out-of-cell fatigue testing development - Task 2.4)

Vibration integrity of high burn-up spent nuclear fuel in transportation remains to be a critical component of US nuclear waste management system. The structural evaluation of package for spent fuel transportation eventually will need to see if the content or spent fuel is in a subcritical condition. However, a system for testing and characterizing such spent fuel is still lacking mainly due to the complication involved with dealing radioactive specimens in a hot cell environment. Apparently, the current state-of-the-art in spent fuel research and development is quite far away from the delivery of reliable mechanical property data for the assessment of spent fuels in the transport package evaluation.

Spent Nuclear Fuel Vibration Integrity↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Vibration Analysis of Advanced Test Reactor Mini-Plate Hydraulic Test in the OSU HMFTF

Currently, flow testing is being performed at Oregon State University (OSU) on the Hydro-Mechanical Fuel Test Facility (HMFTF) to aid in the qualification of low enriched plate-type Uranium fuels for use in high performance research reactors (HPRR) in the US, under the Global Threat Reduction Initiative (GTRI). Under this project, varying fuel geometries proposed for irradiation testing in the Advanced Test Reactor (ATR) are being hydraulically tested in the HMFTF prior to being placed in the ATR; these tests included the use of high-resolution tri-axis accelerometers affixed to the experiment in multiple locations. The premise of this study was to conduct a vibration analysis on the test designated as miniplate1 (MP-1) Large B experiment which is planned for irradiation testing in the ATR's Large B experiment location. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗