Search NASA⌕ Search

SEARCH · Search NASA

Results for “Video Recording”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A framework to share courses among universities: the case of a course on power electronics for electric vehicles

The paper describes the organizational framework and contents of a newly developed course on power electronics for electric drive vehicles. The course is developed and taught synchronously among three universities, with each institution individually managing student registration and assessments, and course administration. The participation of instructors and students from different institutions increases the impact of the course. In addition to the regular classes, followed on campus and remote, the high quality material generated by the instructors is available for the students, including a repository of recorded video lecturers and conferences given by specialist in key topics. Interaction with instructors and among students is promoted using a collaborative on-line tool.

42 ENGINEERING↗

YOLO11 to SAM2 pipeline for feature extraction from nuclear test films

The response to the effects of nuclear detonations is supported by models that describe the evolution of the nuclear fireball and cloud and the associated transport of active debris. Validation of those descriptions relies on data from the nuclear test operations. Video records of those events offer a rich source of information that was exploited to a limited extent in historic analyses. Computer vision and machine learning techniques are powerful tools that can be used to increase the number of measurements that can be obtained from those films. In this work, we apply computer vision techniques to automatically track the temporal evolution of the nuclear fireball. In particular, we apply You Only Look Once 11 (YOLO11) and Segment Anything Model 2 (SAM2) in combination with minimal human intervention to digitized versions of the original nuclear test films. As part of the proposed workflow, the YOLO11 model is applied to films to determine bounding boxes for the fireball within each frame. These are then used as inputs to SAM2, which uses image segmentation to determine the fireball boundaries and their temporal evolution. We assess the accuracy of our approach by using it to determine the energy released during the Trinity nuclear test and comparing the results with previous analyses based on manual measurements.

Van Exel, Kimberly [ORNL] (ORCID:0009000877463894)↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP2-01: A Comparison of Noninvasive Techniques to Assess Radiation-Induced Lung Damage in Mice

Purpose: To evaluate the use of post-irradiation changes in respiratory rate and CBCT-based morphology as predictors of survival in mice. Methods: C57L/J mice underwent whole-thorax irradiation with a Co-60 beam to four different doses [0Gy (n=3), 9Gy (n=5), 11Gy (n=7), and 13Gy (n=5)] in order to induce varying levels of pneumonitis. Respiratory rate measurements, breath-hold CBCTs, and free-breathing CBCTs were acquired pre-irradiation and at six time points between two and seven months post-irradiation. For respiratory rate measurements, we developed a novel computer-vision-based technique. We recorded mice sleeping in standard laboratory cages with a 30 fps, 1080p webcam (Logitech C920). We calculated respiratory rate using corner detection and optical flow to track cyclical motion in the fur in the recorded video. Breath-hold and free-breathing CBCTs were acquired on the X-RAD225Cx system. For breathhold imaging, the mice were intubated and their breath was held at full-inhale for 20 seconds. Healthy lung tissue was delineated in the scans using auto-threshold contouring (0–0.7 g/cm{sup 3}). The volume of healthy lung was measured in each of the scans. Next, lung density was measured in a 6-mm{sup 2} ROI in a fixed anatomic location in each of the scans. Results: Day-to-day variability in respiratory rate with our technique was 13%. All metrics except for breath-hold lung volume were correlated with survival: lung density on free-breathing (r=−0.7482,p<0.01) and breath-hold images (r=−0.5864,p<0.01), free-breathing lung volume (r=0.7179,p<0.01), and respiratory rate (r= 0.6953,p<0.01). Lung density on free-breathing scans was correlated with respiratory rate (r=0.7142,p<0.01) and lung density on breath-hold scans (r=0.5543,p<0.01). One significant practical hurdle in the CBCT measurements was that at least one lobe of the lung was collapsed in 36% of free-breathing scans and 45% of breath-hold scans. Conclusion: Lung density and lung volume on free-breathing CBCTs and respiratory rate outperform breath-hold CBCT measurements as indicators for survival from radiation-induced pneumonitis. This work was partially funded by Elekta.

60 APPLIED LIFE SCIENCES↗

Mechanism of low-frequency discrete acoustic emission during intermittent creep of aluminum alloy

A correlation between the dynamics of deformation bands and the discrete acoustic emission during the intermittent creep of the AlMg{sub 6} alloy using a high-speed video recording with a time resolution to 50 μs has been studied. A trigger of a macroscopic deformation step in the creep curve is the nucleation and the broadening of the primary deformation band that generates a characteristic acoustic emission signal with duration of several milliseconds. The results confirm the mechanism of generating an acoustic emission signal related to the cooperative dislocations outcrop on the specimen external surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of a Lüders Band and Destruction of an Aluminum-Magnesium Alloy, Initiated by a Stress Concentrator

Spatio-temporal localization of deformation and the rupture of the aluminum-magnesium AlMg6 alloy, initiated by a geometrical stress concentrator, are studied in situ by video recording at a speed of 500 to 20000 frames/s. It is established that a stress concentrator in the form of a small notch with a depth about 1% of the width of a flat specimen is an attractor of bands of macrolocalized plastic deformation, starting from a Lüders band and ending with the start of the main crack. The key role of intersecting deformation macrobands in the development of the main crack is revealed. Possible micromechanisms of viscous destruction associated with the dynamics of the intersection of deformation bands are discussed.

36 MATERIALS SCIENCE↗

Effect of Pulsed IR Laser Radiation on the Dynamics and Morphology of Deformation Bands in an Aluminum–Magnesium Alloy

The dynamics and morphology of deformation bands under the simultaneous effect of mechanical loading and pulsed IR laser radiation on the surface of in aluminum–magnesium alloy AlMg6 were studied by high-speed video recording. The conditions, under which a laser pulse pierces a through hole with a diameter of an order of magnitude smaller than the thickness of a plane specimen, thus inducing the development of a complicated spatiotemporal structure of deformation bands and a macroscopic jump in the tension diagram, were determined. The morphological transitions associated with the transformation of the type, shape, and spatiostatistical distribution of bands with a change in the laser pulse energy density were revealed. The probable mechanism of this phenomenon was discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Destruction of the Aluminum–Magnesium Alloy under the Influence of Pulsed Laser Radiation against Creep Conditions

Abstract—Using high-speed video recording, the stages of predestruction and development of a main crack initiated by pulsed infrared laser radiation on the surface of the AlMg6 aluminum–magnesium alloy deformed by the uniaxial tensile testing under creep conditions are studied. The role of macroscopic bands of plastic strain in the development of the last deformation jump with an amplitude of about 10%, and the generation and propagation of the main crack is revealed. A possible mechanism of fracture is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Videos of Chemically Activated Frontal Polymerization of Thermosets

Video recordings of the frontal ring-opening metathesis polymerization (FROMP) of thermoset polymer specimens in 10mm glass test tubes were collected in order to measure the front speed resulting from varied front initiation methods. Maximum front temperature was also measured. Polymerization resins comprised of dicyclopentadiene (DCPD) with 5 wt% 5-ethylidene-2-norbornene (ENB) added, grubbs’ second generation catalyst, and tributyl phosphite (TBP) inhibitor (8000:1:1 monomer:initiator:inhibitor ratio). Polymerization fronts were triggered using concentrated solutions of grubbs’ third generation catalyst in various solvents.

Cramblitt, Anna C.↗

Particles and Nuclei International Conference (PANIC11) at MIT in July 2011 (Final Scientific/Technical Report)

The first Particles and Nuclei International Conference (PANIC11) in the LHC era brought 539 participants to the Massachusetts Institute of Technology from 24-29 July 2011. PANIC11 is the latest conference in a triennial series, which showcases recent progress worldwide in particle and nuclear physics. PANIC11 was held in the year celebrating the 150th anniversary of the founding of MIT as well as the centennial of Rutherford’s May 1911 seminal paper, which explained the discovery of the atomic nucleus. Further, 2011 was the 65th anniversary of MIT’s Laboratory for Nuclear Science, which hosted PANIC11. With strong support by the US Department of Energy, many national laboratories from around the world, industrial sponsors, and by MIT, the conference supported the extensive participation of young scientists, students and postdocs, who were the majority of participants, making for a very lively conference. Broad international participation was enhanced by IUPAP support for scientists from developing countries. The NSF supported video recording and broadcasting via an MIT public website of the plenary sessions, the public lectures, and the pre-conference pedagogical lectures, as well as outreach and participation of students from local high schools.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particles and Nuclei International Conference PANIC11 at MIT Young Scientist Support (Final Scientific/Technical Report)

The first Particles and Nuclei International Conference (PANIC11) in the LHC era brought 539 participants to the Massachusetts Institute of Technology from 24-29 July 2011. PANIC11 is the latest conference in a triennial series, which showcases recent progress worldwide in particle and nuclear physics. PANIC11 was held in the year celebrating the 150th anniversary of the founding of MIT as well as the centennial of Rutherford’s May 1911 seminal paper, which explained the discovery of the atomic nucleus. Further, 2011 was the 65th anniversary of MIT’s Laboratory for Nuclear Science, which hosted PANIC11. With strong support by the US Department of Energy, many national laboratories from around the world, industrial sponsors, and by MIT, the conference supported the extensive participation of young scientists, students and postdocs, who were the majority of participants, making for a very lively conference. Broad international participation was enhanced by IUPAP support for scientists from developing countries. The NSF supported video recording and broadcasting via an MIT public website of the plenary sessions, the public lectures, and the pre-conference pedagogical lectures, as well as outreach and participation of students from local high schools.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PBX-9501 High Explosive Infrared Thermography Test Report

High explosive safety requirements put in place by the Department of Defense necessitate that Los Alamos National Laboratory verify that high melting explosive-based plastic bonded explosive 9501 will not present a health or safety risk to personnel when exposed to various accident scenarios. The JT5R-14C test is being developed to validate this requirement in a scenario where PBX-9501 is exposed to a hydrocarbon fuel fire. Preliminary testing is required to establish benchmark data on the burning characteristics of PBX-9501. The PBX-9501 High Explosive Infrared Thermography test was designed to provide the benchmark burning characteristics of PBX-9501 in a simulated fuel fire environment using propane burners as a fuel source. The PBX-9501-HEIT was successfully completed using a 20.32 cm tall cylindrical sample of PBX-9501 with a radius of 10.16 cm, a volume of 6,589.63 cm 3 , a density of 1.83 g/cm 3 , and a mass of 1.2 kg. The PBX-9501-HEIT test was captured and recorded video sequence using a Telops Inc., Multispectral Infrared camera. The infrared sequence was reviewed to identify key events throughout the test and serves as a visual tool to cross reference against future testing to aid in the identification of PBX-9501 high explosive ignition and deflagration characteristics. The data obtained in the thermographic sequence confirmed that the temperatures emitted by the PBX-9501 were higher than the temperatures of the propane burner ignition source. The propane burner flames had a temperature range of 700-850 °C. The cylindrical sample of PBX-9501 burned at an average temperature of 1000-1200 °C on the surface with off-gassing temperatures averaging 1100-1250 °C. The heat map of the PBX-9501 obtained through the test was between 250-550 °C higher than the propane gas temperatures. The temperature differential between the PBX-9501 and the propane flame allowed for the identification of key burning features.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Plate Impact and Penetration at the Ballistic Launch Tube: Experiments

This report details the data collected from plate impact experiments performed at the Ballistics Launch Tube (BLT) in May 2019. The experiments consisted of 62 shots of copper projectiles (cylindrical and ogive) impacting 1/4", 1/2", and 3/4" aluminum plates at varying velocities. An additional 14 shots of copper cylinders on a 1" steel plate were fired at varying velocities as a Taylor anvil test. We recorded videos of the impact events and resulting fragmentation using a multi-view system of three high speed cameras. The purpose of these tests was to collect high quality data from the multi-view camera system and create digital representations of the deformed target, projectile and fragments. This data is intended to be used as validation data set for high fidelity simulation codes. This report covers the experimental setup, diagnostics, and collected data. Data processing and analysis are underway and will be discussed in a separate report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Visual Examination of Aluminum Containers for Extended Wet Storage of Non-Aluminum-Clad Spent Nuclear Fuel (FY 2021)

The goal of the Augmented Monitoring and Condition Assessment Program (AMCAP) program is to provide a condition assessment of the storage containers for non-aluminum-clad spent nuclear fuel (NASNF) in L Basin and demonstrate continued safe storage of all NASNF pending retrieval for ultimate disposition. The storage configuration of NASNF is vulnerable to inside-out corrosion attack. The approach being used in AMCAP is to develop and deploy examination methods for remote, in-situ inspection of the bundle storage in VTS and for OSC storage in the OSC racks. A method for Visual Examination (VE) using video-recording cameras was readied as part of the full-scale mockup development, and was deployed in L Basin for the initial condition assessment work. This report describes the development and the deployment of the VE for inspection of selected bundles in L Basin. The first deployment of the VE system was for visually examining five spent fuel bundles. Bundles were chosen based on their vulnerability in terms of inner fuel contents, history, storage duration, storage configuration, and possibility of inside out corrosion due to galvanic coupling of fuel cladding with the aluminum bundle wall.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRIB Lithium Stripper Thickness and Stability Measurements

This report documents the results of a number of tests of the prototype liquid lithium thin film stripper for FRIB, in which 1) the thickness of a flowing film of liquid lithium was measured in real time, 2) the thickness distribution of the film was measured in real time, and 3) the stability of the films was determined based on both digital video recordings and digital signal recordings of Faraday cup current. The high-pressure liquid lithium system, capable of driving liquid lithium at up to 13.9 MPa (2000 psia) through a nozzle opening as large as 1 mm (40 mil) in diameter, is described. As part of the work reported here, the system was modified to facilitate convenient and efficient testing of design variations in nozzle and deflector geometry so that their effect on film thickness and film stability improvement could be determined. A previously developed electron beam based thickness measuring system was recalibrated for this specific geometry and used to measure the film thickness under a number of different flow conditions and deflector designs. A thin film ~9 mm in width flowing at a velocity of ~60 m/s was formed under several flow conditions and with several deflector designs. A deflector design was found that practically eliminates the puddle issue. The film stability is judged to be excellent; based upon a ~25 minute stable flow run during which time only a single breakup of the film occurred. That breakup event, which lasted only about 0.6 second, was most likely caused by an Ar gas bubble that became trapped in the high-pressure lithium line, during lithium transfer operations. The trapped gas issue will not be a problem for the FRIB stripper system because a pumped, closed loop system will be used, eliminating the need for lithium transfer operations. Based on thickness distribution measurements from the electron beam system, the expected central thickness (at halfway between center spot and bottom spot) is 632 ± 35 μg/cm2 (± 5.5% for 1 mm spot diameter). This corresponds to a physical thickness of the flowing lithium film of 12.3 ± 0.7 μm.

36 MATERIALS SCIENCE↗

Orientation to NPHR: Scripts for Training

The IAEA is training staff to train member states to use the Nuclear Power Human Resources (NPHR) model, developed at LANL, to examine their human resource plans. Part of the NPHR training involves orienting users to the files used by NPHR, namely the data file and the model files. To assist the IAEA trainers, the scripts in this document were developed for conducting the orientation sections. The scripts are intended to be used as resources for the trainers to develop their ability to deliver the orientation and not as scripts to be read to a training workshop. The scripts are accompanied by video recordings to illustrate what the trainers will show participants during the orientation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Swept-Lookback Deflectometry for High Performance Concentrating Solar Power Optical Metrology

This report describes an initial investigation into a proposed solution to the important problem of performing a detailed evaluation of heliostat optical performance, in situ in a heliostat field. Our approach is to place digital cameras in a position near the receiver where they look back toward the heliostat mirrors. The pixels of each camera sensor identify a set of small cells on the mirror surface, each corresponding to a “mixel.” By either passing reflected sunbeam over the camera or passing the camera through the reflected sunbeam, the cameras intercept sunlight reflected from each mixel. We then analyze the recorded video data to determine times when each mixel transitions from dark to light, and then back to dark. We then use these transitions to construct vectors from the camera to the mixel, and then from the mixel to the edge of the Sun at that moment. We then compute the surface normal at the mixel, which bisects the angle between these vectors. Performing this analysis for all mixels in the mirror yields a high-resolution map of slope across the mirror surface. We have implemented most of this process, successfully collecting data for an example heliostat facet and computing a preliminary estimated slope map. However, more work remains to complete this calculation, since certain factors and transformations are not yet included. Our observations so far support our hypothesis that such a system is possible, but we have not yet completed our quantitative evaluation of the concept.

14 SOLAR ENERGY↗