Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perception of linear horizontal self-motion induced by peripheral vision /linearvection/ - Basic characteristics and visual-vestibular interactions

The basic characteristics of the sensation of linear horizontal motion have been studied. Objective linear motion was induced by means of a moving cart. Visually induced linear motion perception (linearvection) was obtained by projection of moving images at the periphery of the visual field. Image velocity and luminance thresholds for the appearance of linearvection have been measured and are in the range of those for image motion detection (without sensation of self motion) by the visual system. Latencies of onset are around 1 sec and short term adaptation has been shown. The dynamic range of the visual analyzer as judged by frequency analysis is lower than the vestibular analyzer. Conflicting situations in which visual cues contradict vestibular and other proprioceptive cues show, in the case of linearvection a dominance of vision which supports the idea of an essential although not independent role of vision in self motion perception.

Berthoz, A.↗

Magnetic resonance visualization of conductive structures by sequence-triggered direct currents and spin-echo phase imaging

Purpose: Instrument visualization in interventional magnetic resonance imaging (MRI) is commonly performed via susceptibility artifacts. Unfortunately, this approach suffers from limited conspicuity in inhomogeneous tissue and disturbed spatial encoding. Also, susceptibility artifacts are controllable only by sequence parameters. This work presents the basics of a new visualization method overcoming such problems by applying sequence-triggered direct current (DC) pulses in spin-echo (SE) imaging. SE phase images allow for background free current path localization. Methods: Application of a sequence-triggered DC pulse in SE imaging, e.g., during a time period between radiofrequency excitation and refocusing, results in transient field inhomogeneities. Dependent on the additional z-magnetic field from the DC, a phase offset results despite the refocusing pulse. False spatial encoding is avoided by DC application during periods when read-out or slice-encoding gradients are inactive. A water phantom containing a brass conductor (water equivalent susceptibility) and a titanium needle (serving as susceptibility source) was used to demonstrate the feasibility. Artifact dependence on current strength and orientation was examined. Results: Without DC, the brass conductor was only visible due to its water displacement. The titanium needle showed typical susceptibility artifacts. Applying triggered DC pulses, the phase offset of spins near the conductor appeared. Because SE phase images are homogenous also in regions of persistent field inhomogeneities, the position of the conductor could be determined with high reliability. Artifact characteristic could be easily controlled by amperage leaving sequence parameters unchanged. For an angle of 30° between current and static field visualization was still possible. Conclusions: SE phase images display the position of a conductor carrying pulsed DC free from artifacts caused by persistent field inhomogeneities. Magnitude and phase images are acquired simultaneously under the same conditions without the use of extra measurement time. The presented technique offers many advantages for precise instrument localization in interventional MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A MATLAB-based finite-element visualization of quantum reactive scattering. I. Collinear atom-diatom reactions

We restate the application of the finite element method to collinear triatomic reactive scattering dynamics with a novel treatment of the scattering boundary conditions. The method provides directly the reactive scattering wave function and, subsequently, the probability current density field. Visualizing these quantities provides additional insight into the quantum dynamics of simple chemical reactions beyond simplistic one-dimensional models. Application is made here to a symmetric reaction (H+H{sub 2}), a heavy-light-light reaction (F+H{sub 2}), and a heavy-light-heavy reaction (F+HCl). To accompany this article, we have written a MATLAB code which is fast, simple enough to be accessible to a wide audience, as well as generally applicable to any problem that can be mapped onto a collinear atom-diatom reaction. The code and user's manual are available for download from http://www2.chem.umd.edu/groups/alexander/FEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractionated Conformal Radiotherapy for Management of Optic Nerve Sheath Meningiomas: Long-Term Outcomes of Tumor Control and Visual Function at a Single Institution

Purpose: To provide the long-term outcomes of patients treated with fractionated conformal radiotherapy (FCRT) for presumed optic nerve sheath meningiomas (ONSMs). Patients and Methods: Between 1995 and 2002, 9 patients with a presumed ONSM were treated with FCRT at our institution. The indications for FCRT were significant visual dysfunction at presentation, progression of visual dysfunction during a period of observation, tumor growth documented by sequential imaging, or a combination of these findings. In 2 patients, FCRT was performed as adjuvant therapy, and in 7, it was the initial and primary treatment. Results: Of the 9 patients, 6 were women and 3 were men, with a mean age of 47 years. All 9 patients had evidence of optic nerve dysfunction in the affected eye, characterized by reduced visual acuity, a visual field defect, and a relative afferent pupillary defect. In addition, 2 patients had proptosis and 1 had diplopia. The mean follow-up period was 98 {+-} 31.7 months (median, 90; range, 61-151). After FCRT, the visual function improved in the 7 patients who had undergone FCRT as the primary treatment. However, 2 patients who were blind in their affected eye at FCRT remained blind. In 4 of the 7 patients with improvement, the improvement was documented within 1-3 months after FCRT. The tumor control rate was 100%. Proptosis and diplopia also regressed in 100% of patients. At 2 years after FCRT, 1 patient had developed radiation retinopathy. Conclusion: The results of our study have shown that FCRT is a safe and effective treatment of ONSMs, affording satisfactory long-term tumor control, good functional outcome, and low treatment morbidity. FCRT should be considered the treatment of choice for patients with presumed ONSMs for whom the treatment has been deemed appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Introduction to Data Visualization

Data visualization can be used to present findings, explore data, and use the human eye to find patterns that a computer would struggle to locate. Borrowing tools from art, storytelling, data analytics and software development, data visualization is an indispensable part of the analysis process. While data visualization usage spans across multiple disciplines and sectors, most never receive formal training in the subject. As such, this tutorial will introduce key data visualization building blocks and how to best use those building blocks for different scenarios and audiences. We will also go over tips on accessibility, design and interactive elements. While this will by no means be a complete overview of the data visualization field, by building a foundation and introducing some rules of thumb, attendees will be better equipped for communicating their findings to their audience.

data visualization↗

Experimental testing of flight control head up displays

Experiments and tests with 4 generations of head up displays was reported. The CV 191, based on fighter aircraft gunsights was replaced by the CV 193, with several improvements. The CV 193 V incorporates the velocity vector reference mark, eliminates much other data, clusters the rest in a small area of the visual field and is seen together with the outside landscape. The CV 91 presents only velocity vector and total angle of descent data, used when runway and horizon are visible; TC 121 displays an outline of the runway and can be used in visual and instrument approaches.

Berjal, M.↗

Personal Experience with the PVHD and Opinion of Situations in Which a Wide Field of View (FOV) PVHD Might Be Helpful

Personal experience with the PVHD indicates that it should have great promise in easing cockpit workload, improving situational awareness, and reducing spatial disorientation. It should not be assumed that the PVHD will automatically cue the pilot to his attitude without some training or exposure. Some measure of attention needs to be devoted to attitude although this can easily be accomplished by the peripheral visual fields without tying up central vision. The PVHD would appear useful in any aircraft that flies in spatially disorienting/misorienting conditions, such as night, weather, or formation. It would appear to be particularly useful in aircraft, that by their design, are especially disorienting in such circumstances.

Mcnaughton, G. B.↗

Evaluation of Visualization Heuristics

Heuristics have been used since the early 1990's in the Human Computer Interaction (HCI) domain, for evaluating user interfaces. Most notably, heuristics developed by Nielsen and Molich (1990) have been used by the HCI community. Forsell and Johansson (2010) used the same methodology as Nielsen and Molich and developed a set of 10 heuristics for information visualization. Currently, neither the information visualization or the visual analytics community has adopted these heuristics. However, several studies have been conducted using heuristics. Hearst et al. (2015) found that using the heuristics for visualizations along with asking questions about the data resulted in complementary results as the questions about the data could compensate for heuristics that were difficult to understand and apply. Heli Väätäjä et al. (2016) found that heuristics related to interaction, veracity, and aesthetics needed to be added to the Forsell and Johansson (2010) set. They also noted that a lack of domain knowledge caused the evaluators issues in conducting a heuristic evaluation. We conducted a controlled experiment to determine what factors might impact the expert evaluators' capability to conduct a heuristic evaluation of a static information visualization. In particular, we wanted to understand how their familiarity with the visualizations and their experience in conducting heuristic evaluations impacted their evaluations of visualizations. We recruited 10 participants who were domain experts in the visualization field each having experience with one of more of the following: user experience design or research, user interface development, and human computer interaction research. We used a heuristic set proposed by Forsell and Johansson. Participants were also asked to complete a demographic survey in which they rated their experience with each visualization type generally, their experience conducting heuristic evaluations, their experience using each visualization type to extract information, and their experience developing and creating each visualization type. The participants were shown a series of 5 common visualizations (Scatterplots, Sunbursts, Tree Maps, Parallel Sets, and Area Graphs) all displaying the VAST 2008 Mini Challenge Two- Migrant Boats data . Participants were given a suggested analytical question related to each visualization to keep in mind as they applied the 10 heuristics to each visualization. They were asked if they could find any usability problems in the visualizations and which heuristic(s) helped them to identify these problems. The participants were asked to rate how relevant each heuristic was for evaluating each visualization along with rating how confident they felt in their ability to apply the heuristic to evaluate each visualization. At the conclusion of the study, participants provided qualitative feedback on the usability issues of each visualization. Additionally, we collected eye tracking data on 6 of the 10 participants. We will be using this data to determine how long participants looked at the various visualizations and what parts of the visualizations they focused on. We had two hypotheses for this empirical evaluation: 1.The Forsell and Johansson heuristics of Orientation and help, Data set reduction, and Prompting are less useful for static visualizations because they require some interaction in order to test completely. 2.Participants that do not have experience with heuristic evaluation will provide lower evaluation scores for the heuristics compared to those that have experience. Related to hypothesis 1, as our study used only static visualizations, interaction-related usability challenges should be harder to identify. This should result in lower usefulness ratings for those heuristics. Preliminary results indicate that participants found it more difficult to apply heuristics to unfamiliar visualizations.

Williams, Ryan G.↗

Fractionated Stereotactic Radiotherapy in Patients With Optic Nerve Sheath Meningioma

Purpose: To evaluate the effectiveness of fractionated stereotactic radiotherapy (SFRT) in the treatment of optic nerve sheath meningioma (ONSM). Methods and Materials: Between 1993 and 2005, 109 patients (113 eyes) with primary (n = 37) or secondary (n = 76) ONSM were treated according to a prospective protocol with SFRT to a median dose of 54 Gy. All patients underwent radiographic, ophthalmologic, and endocrine analysis before and after SFRT. Radiographic response, visual control, and late side effects were endpoints of the analysis. Results: Median time to last clinical, radiographic, and ophthalmologic follow up was 30.2 months (n = 113), 42.7 months (n = 108), and 53.7 months (n = 91), respectively. Regression of the tumor was observed in 5 eyes and progression in 4 eyes, whereas 104 remained stable. Visual acuity improved in 12, deteriorated in 11, and remained stable in 68 eyes. Mean visual field defects reduced from 33.6% (n = 90) to 17.8% (n = 56) in ipsilateral and from 10% (n = 94) to 6.7% (n = 62) in contralateral eyes. Ocular motility improved in 23, remained stable in 65, and deteriorated in 3 eyes. Radiographic tumor control was 100% at 3 years and 98% at 5 years. Visual acuity was preserved in 94.8% after 3 years and in 90.9% after 5 years. Endocrine function was normal in 90.8% after 3 years and in 81.3% after 5 years. Conclusions: SFRT represents a highly effective treatment for ONSM. Interdisciplinary counseling of the patients is recommended. Because of the high rate of preservation of visual acuity we consider SFRT the standard approach for the treatment of ONSM. Prolonged observation is warranted to more accurately assess late visual impairment. Moderate de-escalation of the radiation dose might improve the preservation of visual acuity and pituitary gland function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Visual motion integration for perception and pursuit

To examine the relationship between visual motion processing for perception and pursuit, we measured the pursuit eye-movement and perceptual responses to the same complex-motion stimuli. We show that humans can both perceive and pursue the motion of line-figure objects, even when partial occlusion makes the resulting image motion vastly different from the underlying object motion. Our results show that both perception and pursuit can perform largely accurate motion integration, i.e. the selective combination of local motion signals across the visual field to derive global object motion. Furthermore, because we manipulated perceived motion while keeping image motion identical, the observed parallel changes in perception and pursuit show that the motion signals driving steady-state pursuit and perception are linked. These findings disprove current pursuit models whose control strategy is to minimize retinal image motion, and suggest a new framework for the interplay between visual cortex and cerebellum in visuomotor control.

NASA Center ARC↗

Image Processor

Texas Instruments Programmable Remapper is a research tool used to determine how to best utilize the part of a patient's visual field still usable by mapping onto his field of vision with manipulated imagery. It is an offshoot of a NASA program for speeding up, improving the accuracy of pattern recognition in video imagery. The Remapper enables an image to be "pushed around" so more of it falls into the functional portions in the retina of a low vision person. It works at video rates, and researchers hope to significantly reduce its size and cost, creating a wearable prosthesis for visually impaired people.

Source record↗

Increased Intracranial Pressure and Visual Impairment Associated with Long-Duration Spaceflight

Although humans have been flying in space since the 1960s, more recent missions have revealed a new suite of physiological adaptations and consequences of space flight. Notably, 60% of long-duration crewmembers (ISS/MIR) and >25% of short-duration (Shuttle) crewmembers have reported subjective degradation in vision (based on debrief comments) (Gibson 2011). Decreased near-visual acuity was demonstrated in 46% of ISS/Mir and 21% of Shuttle crewmembers, resulting in a shift of up to 1-2 diopters in their refractive correction. It is likely that the recently revealed ophthalmic changes have been present since the first days of human space flight, but have been overlooked or attributed to other causations. The reported changes in vision have occurred at various time points throughout missions, with ranging degrees of visual degradation. Although some cases resolved upon return to Earth, several astronauts have not regained preflight visual acuity, indicating that the damage may be permanent. While observing these changes over the years, without other overt symptomology and with the given age range of the flying population, this has largely been attributed to an expected hyperopic shift due to aging. However, the availability of onboard analysis techniques, including visual acuity assessments, retinal imagery, and ultrasounds of the eye and optic nerve tracts, along with more detailed post-flight techniques, has led to the recent recognition of a wider syndrome. Along with vision changes, findings include flattening of the globe, swelling of the optic disc (papilledema), choroidal folds in the retina, swelling of the optic nerve sheath, and visual field defects. It is widely hypothesized that this constellation of findings may be explained by an elevation of intracranial pressure (ICP). Out of the 60% of long-duration astronauts that have reported a subjective degradation in vision, a subset (currently 10 astronauts) have developed this syndrome. The National Aeronautics and Space Administration (NASA) has made it a high priority to understand this syndrome and provide mitigation techniques to protect crewmembers from visual impairment. While there are many possible factors that could contribute to intracranial hypertension associated with spaceflight, the relative contribution of these, as well as the processes by which eye damage occurs as a result of intracranial hypertension, are not fully understood. The observed pathophysiological phenomena are extremely complex and it is likely that multiple factors contribute to their incidence, rather than one simple mechanism. This paper will define and examine the findings in detail, and expound upon the potential contributing factors and their relative contribution to this syndrome.

Marshall-Bowman, Karina↗

Conspicuity of target lights: The influence of flash rate and brightness

The stimulus characteristics of lights that might aid a pilot to see and avoid, by alerting him to a potential threat were studied. The relative conspicuity of foveally equated, point-source, steady and flashing lights of several brightnesses, seen against a star background was examined. From the subject's viewpoint, these target lights could appear anywhere within a large (40 deg horizontal by 35 deg vertical) field of view. The lights appeared at random time intervals while the subject was periodically distracted by a simulated cockpit task. The results indicate that correct target detection increases and reaction time decreases with increased target intensity. Steady lights are missed more frequently and acquired more slowly than flashing lights, but no significant differences are found among the wide range of flash rates employed. The intensity of the light has a greater effect on both detection and reaction time to steady lights than to flashing lights. These results are compared with results of other researchers who used targets which appeared at fixed locations. The longest reaction times were recorded to lights which appeared either at the extremes or at the very center of the visual field.

Connors, M. M.↗

Retinal, attentional, and causal aspects of illusory-motion directionality

Extended objects presented instantaneously appeared to propagate or grow into their final shape. A strong bias was found toward perceiving straight lines to grow away from the observer's point of fixation. If attention and fixation were not directed to the same point of the visual field, both influenced illusory motion directionality, and if another small object was present on the screen at a location that was neither fixated nor attended to, the object that was instantaneously presented seemed to grow away from this point. Thus, three factors are involved in illusory-motion directionality: biases toward perceiving objects spreading away from the fixation point, away from an attended area, and away from preexisting objects. The experiments indicate that a satisfactory explanation of the illusion has to include bottom-up and top-down processes. They also challenge existing theories of motion detection.

Pattern Recognition, Visual/physiology↗

Orientation of human optokinetic nystagmus to gravity: a model-based approach

Optokinetic nystagmus (OKN) was induced by having subjects watch a moving display in a binocular, head-fixed apparatus. The display was composed of 3.3 degrees stripes moving at 35 degrees/s for 45 s. It subtended 88 degrees horizontally by 72 degrees vertically of the central visual field and could be oriented to rotate about axes that were upright or tilted 45 degrees or 90 degrees. The head was held upright or was tilted 45 degrees left or right on the body during stimulation. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined and compared with the axis of stimulation and the spatial vertical (gravity axis). With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted, a significant vertical component of eye velocity appeared during yaw axis stimulation. As a result the axis of eye rotation shifted from the stimulus axis toward the spatial vertical. Vertical components developed within 1-2 s of stimulus onset and persisted until the end of stimulation. In the six subjects there was a mean shift of the axis of eye rotation during yaw axis stimulation of approximately 18 degrees with the head tilted 45 degrees on the body. Oblique optokinetic stimulation with the head upright was associated with a mean shift of the axis of eye rotation toward the spatial vertical of 9.2 degrees. When the head was tilted and the same oblique stimulation was given, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 degrees. This counterrotation of the axis of eye rotation is similar to the "Muller (E) effect," in which the perception of the upright is counterrotated to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN with a "direct" and "indirect" pathway. It was assumed that the direct visual pathway is oriented in a body, not a spatial frame of reference. Despite the short optokinetic after-nystagmus time constants, strong horizontal to vertical cross-coupling could be produced if the horizontal and vertical time constants were in proper ratio and there were no suppression of nystagmus in directions orthogonal to the stimulus direction. The model demonstrates that the spatial orientation of OKN can be achieved by restructuring the system matrix of velocity storage. We conclude that an important function of velocity storage is to orient slow-phase velocity toward the spatial vertical during movement in a terrestrial environment.

Non-NASA Center↗

Preliminary Results of Fractionated Stereotactic Radiotherapy After Cyst Drainage for Craniopharyngioma in Adults

Purpose: To retrospectively evaluate the effectiveness of fractionated stereotactic radiotherapy (FSRT) for craniopharyngioma. Methods and Materials: Between 1999 and 2005, 16 patients with craniopharyngioma were referred to Tokyo Medical University Hospital. They received FSRT alone after histologic confirmation by needle biopsy and underwent cyst drainage via endoscopy. The median prescription dose fraction was 30 Gy in six fractions. All patients except 1 were followed up until December 2009 or death. Results: The median follow-up period was 52 months (range, 4-117 months). Of the 17 patients, 3 experienced recurrence 4 to 71 months after FSRT. The 3-year local control rate was 82.4%. One patient died of thyroid cancer, and the 3-year survival rate was 94.1%. Eight patients had improved visual fields at a median of 2.5 months after FSRT, but hormonal functions did not improve in any patient. Conclusions: FSRT after cyst drainage seems to be safe and effective for patients with craniopharyngiomas, and it may be a safe alternative to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗