Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Threat of Uncertainty: Why Using Traditional Approaches for Evaluating Spacecraft Reliability are Insufficient for Future Human Mars Missions

Through the Evolvable Mars Campaign (EMC) study, the National Aeronautics and Space Administration (NASA) continues to evaluate potential approaches for sending humans beyond low Earth orbit (LEO). A key aspect of these missions is the strategy that is employed to maintain and repair the spacecraft systems, ensuring that they continue to function and support the crew. Long duration missions beyond LEO present unique and severe maintainability challenges due to a variety of factors, including: limited to no opportunities for resupply, the distance from Earth, mass and volume constraints of spacecraft, high sensitivity of transportation element designs to variation in mass, the lack of abort opportunities to Earth, limited hardware heritage information, and the operation of human-rated systems in a radiation environment with little to no experience. The current approach to maintainability, as implemented on ISS, which includes a large number of spares pre-positioned on ISS, a larger supply sitting on Earth waiting to be flown to ISS, and an on demand delivery of logistics from Earth, is not feasible for future deep space human missions. For missions beyond LEO, significant modifications to the maintainability approach will be required.Through the EMC evaluations, several key findings related to the reliability and safety of the Mars spacecraft have been made. The nature of random and induced failures presents significant issues for deep space missions. Because spare parts cannot be flown as needed for Mars missions, all required spares must be flown with the mission or pre-positioned. These spares must cover all anticipated failure modes and provide a level of overall reliability and safety that is satisfactory for human missions. This will require a large amount of mass and volume be dedicated to storage and transport of spares for the mission. Further, there is, and will continue to be, a significant amount of uncertainty regarding failure rates for spacecraft components. This uncertainty makes it much more difficult to anticipate failures and will potentially require an even larger amount of spares to provide an acceptable level of safety. Ultimately, the approach to maintenance and repair applied to ISS, focusing on the supply of spare parts, may not be tenable for deep space missions. Other approaches, such as commonality of components, simplification of systems, and in-situ manufacturing will be required.

Stromgren, Chel↗

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-747: The Use of the EQD2 Formalism and Repair Estimates in the Re-Irradiation Setting and Correlation with Patient Follow-Up Data

Purpose: Medical advances have resulted in cancer patients living longer as evidenced by the number of patients seen for possible re-irradiation. Original normal tissue dose volume constraints remain in the re-irradiation setting to minimize normal tissue toxicity. This work correlates estimates of equivalent dose and repair with sequelae. Methods: CNS and GI tract re-irradiation patient follow-up records (including imaging studies) were reviewed with side effects correlated with the calculated EQD2 and repair estimates. Results: Follow-up records for 16 re-irradiation patients with potential overlap to the spinal cord were analyzed. The mean time interval between 1st and last courses was 76.6 months. Three patients underwent a 3rd course of radiotherapy with a mean time interval between 2nd and final courses of 19.7 months. The mean values for assumed repair were 18.8% and 8.3%, respectively. The calculated total EQD2 doses were 48.09Gy and 50.98Gy with and without repair. At a mean follow-up time of 5.0 months, 6 patients were deceased and no records indicate radiation related neurological deficits. The records for 11 patients with potential overlap to the bowel were also analyzed. The mean time interval between 1st and last courses was 105.9 months. The mean value for assumed repair was 15.9%. The calculated total EQD2 doses were 64.96Gy and 70.80Gy with and without repair. At a mean follow-up time of 4.9 months, 6 patients were deceased, one having a potential enteric fistulization of the bladder. Clinical review of the case determined that the fistula was caused by tumor progression and not a side effect of radiotherapy treatments. Conclusion: Application of the EQD2 method in the re-irradiation setting using conservative estimates of repair is presented. Adhering to accepted dose volume limits following this application is demonstrated to be safe through empirical records as limited by this small patient cohort and short follow-up.

60 APPLIED LIFE SCIENCES↗

Combined shape and topology optimization for minimization of maximal von Mises stress

Here, this work shows that a combined shape and topology optimization method can produce optimal 2D designs with minimal stress subject to a volume constraint. The method represents the surface explicitly and discretizes the domain into a simplicial complex which adapts both structural shape and topology. By performing repeated topology and shape optimizations and adaptive mesh updates, we can minimize the maximum von Mises stress using the p-norm stress measure with p-values as high as 30, provided that the stress is calculated with sufficient accuracy.

42 ENGINEERING↗

Response tailoring of elasto-plastic trusses

Abstract In this work we tailor the response of trusses loaded beyond their yield limit. The truss structures are modeled using finite strain theory and rate-independent elasto-plasticity. We design trusses with a tailored mechanical response that is between “elastic” and “elastic-ideal-plastic” subject to the volume constraint. The design updates are generated by the gradient-based Method of Moving Asymptotes (MMA) solver and the sensitivities of the response functions are computed using a path-dependent adjoint sensitivity analysis. The computations are performed in Matlab.

42 ENGINEERING↗

Comparison of box-wing and conventional aircraft mission performance using multidisciplinary analysis and optimization

Box-wing aircraft designs have the potential to achieve significant reductions in fuel consumption. Closed non-planar wing designs have been shown to reduce induced drag and the statically indeterminate wing structure can lead to reduced wing weight. In addition, the streamwise separation of the two main wings can provide the moments necessary for static stability and control, eliminating the weight and aerodynamic drag of a horizontal tail. Proper assessment of the disciplinary interactions in box-wing designs is essential to determine any realistic performance benefits arising from the use of such a configuration. This study analyzes both box-wing and conventional aircraft designed for representative regional-jet missions. A preliminary parametric investigation shows a lift-to-drag ratio advantage for box-wing designs, while a more detailed multidisciplinary study indicates that the requirement to carry the mission fuel in the wings leads to an increase of between 5% and 1% in total fuel burn compared to conventional designs. Furthermore, the multidisciplinary study identified operating conditions where the box-wing can have superior performance to conventional aircraft despite the fuel volume constraint.

42 ENGINEERING↗

An extended three-field principle to scale-bridge the granular micromechanics of polymer-bonded particulate materials

Observed phenomena of damage, viscoelasticity, and viscoplasticity in polymer-bonded particulate materials (PBPM), like polymer-bonded explosive (PBX), are accommodated in a scale-bridging constitutive model based on granular micromechanics. An extended three-field variational principle with min - max optimization problem is introduced to homogenize the bonded aggregates’ grain-scale contact mechanics. Similarly to prior applications of a three-field principle, volume constraints are invoked to embed microscale-to-macroscale correspondences for kinematic and static volumetric measures, like mean strain and its energy-conjugate stress invariant. Unlike prior applications, our three-field principle realizes a strain-driven model for effective constitutive behavior due to bonded intergranular contact. In conclusion, the resultant micro-sphere integration-based homogenization is demonstrated in comparison to existing publicly-available measurements to capture the extreme tension/compression constitutive asymmetry exhibited by PBPMs (specifically PBX-9501) during material softening.

42 ENGINEERING↗

Correlation Between Dosimetric Parameters and Late Rectal and Urinary Toxicities in Patients Treated With High-Dose-Rate Brachytherapy Used as Monotherapy for Prostate Cancer

Purpose: To evaluate the correlation between dosimetric parameters and late rectal and urinary toxicities in high-dose-rate brachytherapy (HDR-BT) used as monotherapy for prostate cancer. Methods and Materials: The data of 83 patients treated with HDR-BT alone for prostate cancer from 2001 through 2005 at Osaka University Hospital were analyzed. Median follow-up time was 36 months (range, 18-70). The total prescribed dose was 54 Gy in nine fractions over 5 days. Correlation between dosimetric parameters and late toxicities was examined. Results: The means of V30, V40, V50, V60, V70, D1cc, D2cc, D5cc, and D10cc of the rectum were significantly higher in 18 patients who presented with late rectal toxicity (Grades 1-3 rectal bleeding) than in the other 65 patients who did not. A significant difference was observed for D1cc-10cc but not for D5-90. The statistically most significant difference was observed for V40 and D5cc. Late rectal toxicity rate was significantly higher for patients with rectal V40 >= 8 cc than those with the rectal V40 < 8 cc (42% vs. 8%; p < 0.001), as well as for patients with rectal D5cc >= 27 Gy compared with those with rectal D5cc < 27 Gy (50% vs. 11%; p < 0.001). Dosimetric parameters of the urethra of 15 patients with late urinary toxicity were not significantly different from the 68 patients without toxicity. Conclusion: Rectal V40 < 8 cc and D5cc < 27 Gy may be dose-volume constraints in HDR-BT used as monotherapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Constant vs. Variable Relative Biological Effectiveness in Treatment Planning of Intensity-Modulated Proton Therapy

Purpose: To investigate in a simulation study whether using a variable relative biological effectiveness (RBE) in calculation and optimization of intensity-modulated proton therapy (IMPT) instead of using an RBE of 1.1 would result in significant changes in the RBE-weighted dose (RWD) distributions. Methods and Materials: For 4 patients with head-and-neck tumors, three IMPT plans were prepared respectively. The first plan was physically optimized (IMPT-PO plan), and the RWD was calculated with a constant RBE of 1.1. Then the plan's RWD was recalculated (IMPT-R plan) using a variable RBE model taking into account the linear energy transfer (LET) and tissue-specific radiobiological parameters. The third IMPT plan was optimized using a biological optimization routine (IMPT-BO plan). Results: Comparing the IMPT-PO and IMPT-R plans, we observed that the RWD in radioresistant tissues was more sensitive to the LET than in radiosensitive tissues. The IMPT-R plans were in general more inhomogeneous than the IMPT-PO plans. The differences of RWD distributions for all volumes between IMPT-PO and IMPT-BO plans complied with predefined dose-volume constraints. The average LET was significantly lower in IMPT-BO plans than in IMPT-R plans. Conclusion: In radioresistant normal tissues caution has to be used regarding the LET distribution because these are most sensitive to changes in the LET. Biological optimization of IMPT plans based on the organ-specific biological parameters and LET distributions is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast Cancer

Purpose: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance. Methods and Materials: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricular branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test. Results: The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses. Conclusions: This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spinal Cord Tolerance in the Age of Spinal Radiosurgery: Lessons From Preclinical Studies

Clinical implementation of spinal radiosurgery has increased rapidly in recent years, but little is known regarding human spinal cord tolerance to single-fraction irradiation. In contrast, preclinical studies in single-fraction spinal cord tolerance have been ongoing since the 1970s. The influences of field length, dose rate, inhomogeneous dose distributions, and reirradiation have all been investigated. This review summarizes literature regarding single-fraction spinal cord tolerance in preclinical models with an emphasis on practical clinical significance. The outcomes of studies that incorporate uniform irradiation are surprisingly consistent among multiple small- and large-animal models. Extensive investigation of inhomogeneous dose distributions in the rat has demonstrated a significant dose-volume effect while preliminary results from one pig study are contradictory. Preclinical spinal cord dose-volume studies indicate that dose distribution is more critical than the volume irradiated suggesting that neither dose-volume histogram analysis nor absolute volume constraints are effective in predicting complications. Reirradiation data are sparse, but results from guinea pig, rat, and pig studies are consistent with the hypothesis that the spinal cord possesses a large capacity for repair. The mechanisms behind the phenomena observed in spinal cord studies are not readily explained and the ability of dose response models to predict outcomes is variable underscoring the need for further investigation. Animal studies provide insight into the phenomena and mechanisms of radiosensitivity but the true significance of animal studies can only be discovered through clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decreased Risk of Radiation Pneumonitis With Incidental Concurrent Use of Angiotensin-Converting Enzyme Inhibitors and Thoracic Radiation Therapy

Purpose: Angiotensin-converting enzyme (ACE) inhibitors have been shown to mitigate radiation-induced lung injury in preclinical models. The aim of this study was to evaluate whether ACE inhibitors decrease the risk of radiation pneumonitis in lung cancer patients receiving thoracic irradiation. Methods and Materials: Patients with Stage I through III small-cell and non-small-cell lung cancer treated definitively with radiation from 2004-2009 at the Clement J. Zablocki Veterans Affairs Medical Center were retrospectively reviewed. Acute pulmonary toxicity was quantified within 6 months of completion of treatment according to the Common Terminology Criteria for Adverse Events version 4. The use of ACE inhibitors, nonsteroidal anti-inflammatory drugs, inhaled glucocorticosteroids, statins, and angiotensin receptor blockers; dose-volume histogram parameters; and patient factors were assessed for association with Grade 2 or higher pneumonitis. Results: A total of 162 patients met the criteria for inclusion. The majority of patients had Stage III disease (64%) and received concurrent chemotherapy (61%). Sixty-two patients were identified as ACE inhibitor users (38%). All patients had acceptable radiation plans based on dose-volume histogram constraints (V20 [volume of lung receiving at least 20 Gy] {<=}37% and mean lung dose {<=}20 Gy) with the exception of 2 patients who did not meet both criteria. Grade 2 or higher pulmonary toxicity occurred in 12 patients (7.4%). The rate of Grade 2 or higher pneumonitis was lower in ACE inhibitor users vs. nonusers (2% vs. 11%, p = 0.032). Rates of Grade 2 or higher pneumonitis were significantly increased in patients aged greater than 70 years (16% vs. 2%, p = 0.005) or in whom V5 (volume of lung receiving at least 5 Gy) was 50% or greater (13% vs. 4%, p = 0.04). V10 (volume of lung receiving at least 10 Gy), V20, V30 (volume of lung receiving at least 30 Gy), and mean lung dose were not independently associated with Grade 2 or higher pneumonitis. Conclusion: ACE inhibitors may decrease the incidence of radiation pneumonitis in patients receiving thoracic radiation for lung cancer. These findings are consistent with preclinical evidence and should be prospectively evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid, coupled approach for modeling charged fluids from the nano to the mesoscale

Here, we develop and demonstrate a new, hybrid simulation approach for charged fluids, which combines the accuracy of the nonlocal, classical density functional theory (cDFT) with the efficiency of the Poisson–Nernst–Planck (PNP) equations. The approach is motivated by the fact that the more accurate description of the physics in the cDFT model is required only near the charged surfaces, while away from these regions the PNP equations provide an acceptable representation of the ionic system. We formulate the hybrid approach in two stages. The first stage defines a coupled hybrid model in which the PNP and cDFT equations act independently on two overlapping domains, subject to suitable interface coupling conditions. At the second stage we apply the principles of the alternating Schwarz method to the hybrid model by using the interface conditions to define the appropriate boundary conditions and volume constraints exchanged between the PNP and the cDFT subdomains. Numerical examples with two representative examples of ionic systems demonstrate the numerical properties of the method and its potential to reduce the computational cost of a full cDFT calculation, while retaining the accuracy of the latter near the charged surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of stereotactic dosimetric end points on overall survival for Stage I non–small cell lung cancer: A critical review

Stereotactic body radiation therapy (SBRT) delivers a high biologically effective dose while minimizing toxicities to surrounding tissues. Within the scope of clinical trials and local practice, there are inconsistencies in dosimetrics used to evaluate plan quality. The purpose of this critical review was to determine if dosimetric parameters used in SBRT plans have an effect on local control (LC), overall survival (OS), and toxicities. A database of relevant trials investigating SBRT for patients with early-stage non–small cell lung cancer was compiled, and a table of dosimetric variables used was created. These parameters were compared and contrasted for LC, OS, and toxicities. Dosimetric end points appear to have no effect on OS or LC. Incidences of rib fractures correlate with a lack of dose-volume constraints (DVCs) reported. This review highlights the great disparity present in clinical trials reporting dosimetrics, DVCs, and toxicities for lung SBRT. Further evidence is required before standard DVCs guidelines can be introduced. Dosimetric end points specific to stereotactic treatment planning have been proposed but require further investigation before clinical implementation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Joining technique for in-oven/autoclave molds manufactured by large scale polymer additive manufacturing

Large scale additive manufacturing (AM) of fiber-reinforced polymer composites has gained traction in the mold and die community over the last decade, largely due to reduced material cost and lead time. However, limitations in mold size remain present due to printer volume constraints and costs associated with large format machines. Here, this paper describes a method for producing additively manufactured polymer molds in segments with an O-ring joint design, which can be machined and subsequently assembled for autoclave applications. The developed joining mechanism allows for maintaining the vacuum integrity during the cure cycle while accounting for the anisotropic nature of the additively manufactured polymer molds. Over a range of tested temperatures, 20–200 °C, the multi-part mold joining design was able to achieve full vacuum of ∼73.7 cmHg (29 inchHg) and maintain a vacuum integrity with vacuum losses less than 1.5 cmHg/5min (0.6 inchHg).

Joining↗

Rate Enhancement of Acid-Catalyzed Alcohol Dehydration by Supramolecular Organic Capsules

The presence of a (sub)nanometric environment has been demonstrated to enhance the rate of homogeneous acid-catalyzed reactions. Conventionally, such catalysts are constructed by directly embedding a catalytically active acid site into the structure of a porous material, linking the acid properties with the properties of the embedding solid. Here, a holoenzyme mimicking approach was used, in which a self-assembled hexameric resorcinarene capsule (1.4 nm 3 cavity) acts like an apoenzyme that transforms into a catalytically active site by hosting hydrated HCl as a cofactor. This capsule binds the hydronium ion together with cyclohexanol (CyOH) and catalyzes the dehydration to cyclohexene with enhanced rates that are 2 orders of magnitude higher than those in the unconstrained environment. Kinetic analysis shows that cyclohexanol dehydration proceeds via an E2 mechanism on hydrated HCl in the unconstrained environment, while the constrained environment of the active capsule induces the stabilization of an ionic intermediate, allowing an E1 mechanism to dominate. By comparison with the reaction in zeolite environments, we show that the direct chemical environment of the capsule or a zeolite wall exerts only a minor direct influence. The volume constraint increases the reaction rate by inducing a larger activation entropy, indicating the stabilization of a later transition state in the E1 mechanism, as well as a higher reaction space of the carbenium ion constituting the transition state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗