Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Ray Tracing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Influence of Ti doping on the incommensurate charge density wave in 1 T –TaS 2

Here, we report temperature-dependent transport and x-ray diffraction measurements of the influence of Ti hole doping on the charge density wave (CDW) in 1T–Ta 1–x Ti x S 2 . Confirming past studies, we find that even trace impurities eliminate the low-temperature commensurate (C) phase in this system. Surprisingly, the magnitude of the in-plane component of the CDW wave vector in the nearly commensurate (NC) phase does not change significantly with Ti concentration, as might be expected from a changing Fermi surface volume. Instead, the angle of the CDW in the basal plane rotates, from 11.9° at x=0 to 16.4° at x=0.12. Ti substitution also leads to an extended region of coexistence between incommensurate (IC) and NC phases, indicating heterogeneous nucleation near the transition. Finally, we explain a resistive anomaly originally observed by Di Salvo [F. J. Di Salvo et al., Phys. Rev. B 12, 2220 (1975)] as arising from pinning of the CDW on the crystal lattice. Our study highlights the importance of commensuration effects in the NC phase, particularly at x ~ 0.08.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolution of the Electrode–Electrolyte Interface of LiNi 0.8 Co 0.15 Al 0.05 O 2 Electrodes Due to Electrochemical and Thermal Stress

For layered oxide cathodes, impedance growth and capacity fade related to reactions at the cathode–electrolyte interface (CEI) are particularly prevalent at high voltage and high temperatures. At a minimum, the CEI layer consists of Li 2 CO 3 , LiF, reduced (relative to the bulk) metal-ion species, and salt decomposition species, but conflicting reports exist regarding their progression during (dis)charging. Utilizing transport measurements in combination with X-ray and nuclear magnetic resonance spectroscopy techniques in our work, we study the evolution of these CEI species as a function of electrochemical and thermal stress for LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA) particle electrodes using a LiPF 6 ethylene carbonate:dimethyl carbonate (1:1 volume ratio) electrolyte. Although initial surface metal reduction does correlate with surface Li 2 CO 3 and LiF, these species are found to decompose upon charging and are absent above 4.25 V. While there is trace LiPF 6 breakdown at room temperature above 4.25 V, thermal aggravation is found to strongly promote salt breakdown and contributes to surface degradation even at lower voltages (4.1 V). An interesting finding of our work was the partial reformation of LiF upon discharge, which warrants further consideration for understanding CEI stability during cycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achieving and documenting closure in plant growth facilities

As NASA proceeds with its effort to develop a Controlled Ecological Life Support System (CELSS) that will provide life support to crews during long duration space missions, it must address the question of facility and system closure. The concept of closure as it pertains to CELSS and engineering specifications, construction problems and monitoring procedures used in the development and operation of a closed plant growth facility for the CELSS program are described. A plant growth facility is one of several modules required for a CELSS. A prototype of this module at Kennedy Space Center is the large (7m tall x 3.5m diameter) Biomass Production Chamber (BPC), the central facility of the CELSS Breadboard Project. The BPC is atmospherically sealed to a leak rate of approximately 5 percent of its total volume per 24 hours. This paper will discuss the requirements for atmospheric closure in the facility, present CO2 and trace gas data from initial tests of the BPC with and without plants, and describe how the chamber was sealed atmospherically. Implications that research conducted in this type of facility will have for the CELSS program are discussed.

Knott, W. M.↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Bidirectional reflection of semitransparent polytetrafluoroethylene (PTFE) sheets on a silver film

In our recent work, record-high solar reflectance (exceeding 99%) has been demonstrated by placing a layer of highly scattering, semitransparent polytetrafluoroethylene (PTFE) sheet on top of a silver film. This can significantly improve the performance of daytime radiative cooling system. Although a PTFE slab of 10-mm thick acts as an excellent diffuse reflector, it is unclear how this dual-layer structure made of a thin PTFE on a mirror-like reflector will alter the bidirectional reflection. Here, we report measurements of the bidirectional reflectance distribution function (BRDF) of the dual-layer structure using a laser scatterometer at the wavelength of 635 nm. Measurements of the BRDF and the bidirectional transmittance distribution function (BTDF) of free-standing PTFE sheets are also performed. The measured BRDF for a PTFE sheet as thin as 236 μm on Ag is essentially diffuse except at large incidence angles. A Monte Carlo ray-tracing method incorporating both surface scattering and volumetric scattering is developed to theoretically model the BRDF in order to elucidate the underlying mechanisms. Finally, the numerical model captures the main features and can be used to study the bidirectional properties for PTFE sheets thinner than what is experimentally available.

42 ENGINEERING↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

SPATIALLY RESOLVED [Fe II] 1.64 {mu}m EMISSION IN NGC 5135: CLUES FOR UNDERSTANDING THE ORIGIN OF THE HARD X-RAYS IN LUMINOUS INFRARED GALAXIES

Spatially resolved near-IR and X-ray imaging of the central region of the luminous infrared galaxy (LIRG) NGC 5135 is presented. The kinematical signatures of strong outflows are detected in the [Fe II] 1.64 {mu}m emission line in a compact region at 0.9 kpc from the nucleus. The derived mechanical energy release is consistent with a supernova rate of 0.05-0.1 yr{sup -1}. The apex of the outflowing gas spatially coincides with the strongest [Fe II] emission peak and with the dominant component of the extranuclear hard X-ray emission. All these features provide evidence for a plausible direct physical link between supernova-driven outflows and the hard X-ray emitting gas in an LIRG. This result is consistent with model predictions of starbursts concentrated in small volumes and with high thermalization efficiencies. A single high-mass X-ray binary (HMXB) as the major source of the hard X-ray emission, although not favored, cannot be ruled out. Outside the active galactic nucleus, the hard X-ray emission in NGC 5135 appears to be dominated by the hot interstellar medium produced by supernova explosions in a compact star-forming region, and not by the emission due to HMXBs. If this scenario is common to (ultra)luminous infrared galaxies, the hard X-rays would only trace the most compact ({<=}100 pc) regions with high supernova and star formation densities, therefore a lower limit to their integrated star formation. The star formation rate derived in NGC 5135 based on its hard X-ray luminosity is a factor of two and four lower than the values obtained from the 24 {mu}m and soft X-ray luminosities, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Workshop on Analysis of Returned Comet Nucleus Samples

This volume contains abstracts that were accepted by the Program Committee for presentation at the workshop on the analysis of returned comet nucleus samples held in Milpitas, California, January 16 to 18, 1989. The abstracts deal with the nature of cometary ices, cryogenic handling and sampling equipment, origin and composition of samples, and spectroscopic, thermal and chemical processing methods of cometary nuclei. Laboratory simulation experimental results on dust samples are reported. Some results obtained from Halley's comet are also included. Microanalytic techniques for examining trace elements of cometary particles, synchrotron x ray fluorescence and instrument neutron activation analysis (INAA), are presented.

Source record↗

EFFECT OF FUEL IMPURITY ON STRUCTURAL INTEGRITY OF Ni-YSZ ANODE OF SOFCS

Electricity production through the integration of coal gasification with solid oxide fuel cells (SOFCs) may potentially be an efficient technique for clean energy generation. However, multiple minor and trace components are naturally present in coals. These impurities in coal gas not only degrade the electrochemical performance of Ni-YSZ anode used in SOFCs, but also severely endanger the structural integrity of the Ni-YSZ anode. In this paper, effect of the trace impurity of the coal syngases on the mechanical degradation of Ni-YSZ anode was studied by using an integrated experimental/modeling approach. Phosphorus is taken as an example of impurity. Anode-support button cell was used to experimentally explore the migration of phosphorous impurity in the Ni-YSZ anode of SOFCs. X-ray mapping was used to show elemental distributions and new phase formation. The subsequent finite element stress analyses were conducted using the actual microstructure of the anode to illustrate the degradation mechanism. It was found that volume expansion induced by the Ni phase change produces high stress level such that local failure of the Ni-YSZ anode is possible under the operating conditions

experimental and modeling↗

EFFECT OF FUEL IMPURITY ON STRUCTURAL INTEGRITY OF Ni-YSZ ANODE OF SOFCs

Electricity production through the integration of coal gasification with solid oxide fuel cells (SOFCs) may potentially be an efficient technique for clean energy generation. However, multiple minor and trace components are naturally present in coals. These impurities in coal gas not only degrade the electrochemical performance of Ni-YSZ anode used in SOFCs, but also severely endanger the structural integrity of the Ni-YSZ anode. In this paper, effect of the trace impurity of the coal syngases on the mechanical degradation of Ni-YSZ anode was studied by using an integrated experimental/modeling approach. Phosphorus is taken as an example of impurity. Anode-support button cell was used to experimentally explore the migration of phosphorous impurity in the Ni-YSZ anode of SOFCs. X-ray mapping was used to show elemental distributions and new phase formation. The subsequent finite element stress analyses were conducted using the actual microstructure of the anode to illustrate the degradation mechanism. It was found that volume expansion induced by the Ni phase change produces high stress level such that local failure of the Ni-YSZ anode is possible under the operating conditions

01 COAL, LIGNITE, AND PEAT↗

Proceedings of Lunar and Planetary Science, Volume 22; Conference, Houston, TX, Mar. 18-22, 1991

Various papers on lunar and planetary science are presented. Individual topics addressed include: analysis of Phobos Mission Gamma ray spectra from Mars, comparison of volcanic and modified landforms from Tharsis Montes on Mars, polygenetic origin of Hrad Vallis region of Mars, new evidence of lacustrine basins on Mars, flood surge through the Lunae Planum Outflow Complex on Mars, interpretation of canyon materials and flood sources on Kasei Valles on Mars, geochemistry of Manson Impact structure rocks, micrometer-sized glass spheres in Apollo 16 soil 61181, isotopic abundances in Pesyanoe of solar-type xenon, mineralogy of 12 large 'chondritic' interplanetary dust particles. Also discussed are: trace elements in chondritic stratospheric particles, evolution of isotopic signatures in lunar regolith nitrogen, pyroclastic deposits on the western limb of the moon, origin of picritic green glass magmas by polybaric fractional fusion, origin of yellow glasses associated with Apollo 15 KREEP basalt fragments, trace elements in 59 mostly highland moon rocks, mineralization on the moon, relation between diogenite cumulates and eucrite magmas.

Ryder, Graham↗

Guided wave radiation from a point source in the proximity of a pipe bend

Throughout the oil and gas industry corrosion and erosion damage monitoring play a central role in managing asset integrity. Recently, the use of guided wave technology in conjunction with tomography techniques has provided the possibility of obtaining point-by-point maps of wall thickness loss over the entire volume of a pipeline section between two ring arrays of ultrasonic transducers. However, current research has focused on straight pipes while little work has been done on pipe bends which are also the most susceptible to developing damage. Tomography of the bend is challenging due to the complexity and computational cost of the 3-D elastic model required to accurately describe guided wave propagation. To overcome this limitation, we introduce a 2-D anisotropic inhomogeneous acoustic model which represents a generalization of the conventional unwrapping used for straight pipes. The shortest-path ray-tracing method is then applied to the 2-D model to compute ray paths and predict the arrival times of the fundamental flexural mode, A0, excited by a point source on the straight section of pipe entering the bend and detected on the opposite side. Good agreement is found between predictions and experiments performed on an 8” diameter (D) pipe with 1.5 D bend radius. The 2-D model also reveals the existence of an acoustic lensing effect which leads to a focusing phenomenon also confirmed by the experiments. The computational efficiency of the 2-D model makes it ideally suited for tomography algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comet Shoemaker-Levy 9 Fragment Size Estimates: How Big was the Parent Body?

The impact of Comet Shoemaker-Levy 9 on Jupiter in July, 1994 was the largest, most energetic impact event on a planet ever witnessed. Because it broke up during a close encounter with Jupiter in 1992, it was bright enough to be discovered more than a year prior to impact, allowing the scientific community an unprecedented opportunity to assess the effects such an event would have. Many excellent observations were made from Earth-based telescopes, the Hubble Space Telescope (HST), and the Galileo spacecraft en route to Jupiter. In this paper, these observations are used in conjunction with computational simulations performed with the CTH shock-physics hydrocode to determine the sizes of the fifteen fragments that made discernible impact features on the planet. To do this, CTH was equipped with a radiative ablation model and a postprocessing radiative ray-trace capability that enabled light-flux predictions (often called the impact flash) for the viewing geometries of Galileo and ground-based observers. The five events recorded by Galileo were calibrated to give fragment size estimates. Compared against ground-based and HST observations, these estimates were extended using a least-squares analysis to assess the impacts of the remaining ten fragments. Some of the largest impacts (L, G, and K) were greater that 1 km in diameter, but the density of the fragments was low, about 0.25 g/cm(exp 3). The volume of the combined fifteen fragments would make a sphere 1.8 km in diameter. Assuming a prebreakup density of 0.5 g/cm(exp 3), the parent body of Shoemaker-Levy 9 had a probable diameter of 1.4 km. The total kinetic energy of all the impacts was equivalent to the explosive yield of 300 Gigatons of TNT.

Crawford, David A.↗

Quantative Measurements of Trace Elements and Three-Dimensional Atomic Scale Characterisation of Presolar O-rich Oxides and Silicates: An Atom Probe Tomography Approach

Presolar grains are recordsof a single moment in stellar evolution which have survived nebula and parent body processingwithin our Solar System. These grains condensed within a range of stellar envi-ronments including asymptotic giant branch stars, red giant branch stars, nova, supernova (SN) and hydrogen burning electron capture supernova(ECSN)[1,2]. Iso-topic and chemical compositions can be used to unravel details about environmental conditions at the time of their condensation and physical and chemical processes occurring at the time. For example,nucleosynthesis, stellar evolution, physical properties of stellar atmos-pheres, mixing from inner core to outer envelope, galac-tic chemical evolution, interstellar medium and parent body processing.NanoSIMS enables detailed characterisation of iso-topic compositions and rapid in situidentification of O-rich presolar oxides and silicates using their character-istic 17O/16O and 18O/16O isotopic ratios.Spectroscopic techniques e.g., auger spectroscopyand transmission electron microscopy, have provided additional details on major and minor chemical signatures. However, due tospatial resolution limitations,interaction volumes and interferencesfrom surrounding grains for in situtech-niques, attaining quantative characterisation of trace el-ements,hasproved challenging[1,3]. As the most sensitive geochemical tracers of envi-ronmental changes, trace elements are essential to un-ravelling the geochemical record of their parent stellar environments and evolutionary pathways[4].We car-ried out correlated in situisotopic and chemical analyses of 13 presolar grains to better understand stellar evolu-tion. In this work, we achieved this using a custom ap-proach, coordinating NanoSIMS, Scanning Electron Microscopy Energy Dispersive X-Ray Spectroscopy (SEM-EDX)and Atom Probe Tomography(APT).Our objective was to develop an approach which could ena-ble precise targeting of presolar grains for atom probe tomography and successfully execute atomic scale anal-yses of presolar oxides and silicates, to achieve quantative analysis of their trace elements for the first time.We also aimed to test the capability for Atom Probe tomography to measure isotopic compositions and stoichiometries of presolar oxide and silicate grains.

N D Nevill↗

Ultra-Thin Coatings Beautify Art

The craftsmen in the Roman Empire who constructed the Lycurgus Cup 17 centuries ago probably didn't think their artifact would survive for nearly 2,000 years as a prized possession. And they certainly couldn't have known that the technology they used to make it would eventually become an important part of space exploration. Carved from one solid mass, the cup is one of the few complete glass objects from that period, and the only one made from dichroic glass. Meaning "two-colored" in Greek, dichroic glass was originally created by adding trace amounts of gold and silver to a large volume of glass melt. The resulting medium partially reflects the light passing through it, causing an observer to see different colors depending on the direction of the light source. The Lycurgus Cup, for example, is famous for appearing green in daylight and red when lit at night, symbolic of the ripening grapes used to fill it with wine. NASA revitalized the production of dichroic glass in the 1950s and 1960s as a means of protecting its astronauts. Ordinary clear substances cannot protect human vision from the harsh rays of unfiltered sunlight, and everything from the human body to spacecraft sensors and computers are at risk if left unprotected from the radiation that permeates space. The microscopic amounts of metal present in dichroic glass make it an effective barrier against such harmful radiation. While the ancient manufacturing technique called for adding metals to glass melt, NASA developed a process in which metals are vaporized by electron beams in a vacuum chamber and then applied directly to surfaces in an ultra-thin film. The vapor condenses in the form of crystal structures, and the process is repeated for up to several dozen coatings. The resulting material, still only about 30 millionths of an inch thick, is sufficient to reflect radiation even while the glass, or polycarbonate, as in the case of space suit helmets, remains transparent to the human eye.

Source record↗

Linear feature detection algorithm for astronomical surveys – II. Defocusing effects on meteor tracks

Given the current limited knowledge of meteor plasma micro-physics and its interaction with the surrounding atmosphere and ionosphere, meteors are a highly interesting observational target for high-resolution wide-field astronomical surveys. Such surveys are capable of resolving the physical size of meteor plasma heads, but they produce large volumes of images that need to be automatically inspected for possible existence of long linear features produced by meteors. Here in this paper, we show how big aperture sky survey telescopes detect meteors as defocused tracks with a central brightness depression. We derive an analytic expression for a defocused point source meteor track and use it to calculate brightness profiles of meteors modelled as uniform brightness discs. We apply our modelling to meteor images as seen by the Sloan Digital Sky Survey and Large Synoptic Survey Telescope telescopes. The expression is validated by Monte Carlo ray-tracing simulations of photons travelling through the atmosphere and the Large Synoptic Survey Telescope telescope optics. We show that estimates of the meteor distance and size can be extracted from the measured full width at half-maximum and the strength of the central dip in the observed brightness profile. However, this extraction becomes difficult when the defocused meteor track is distorted by the atmospheric seeing or contaminated by a long-lasting glowing meteor trail. The full width at half-maximum of satellite tracks is distinctly narrower than meteor values, which enables removal of a possible confusion between satellites and meteors.

79 ASTRONOMY AND ASTROPHYSICS↗

HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR brachytherapy planning.

61 RADIATION PROTECTION AND DOSIMETRY↗