Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALL TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Flame flashback in a premixed dump combustor

A stainless steel, rectangular center-dump, premixed-prevaporized combustor was used at the NASA Lewis Research Center to study flashback in controlled conditions simulating gas turbine combustor operations under steady-state and transient conditions. The combustor allowed visual access to the combustion area, and was operated at inlet air temperatures from 600 to 850 K, premixer wall temperatures from 450 to 900 K, and average premixer velocity from 40 to 80 ft/s. A parametric study revealed a slight decrease in the flashback equivalence ratio as the inlet air temperatures increased. It also indicated that the premixer wall temperature and premixer velocity are not governing parameters of flashback. It is suggested that flashback occurs through the premixer wall boundary layer flow reversal caused by combustion instability.

Proctor, M. P.↗

An Analysis of Nuclear-Rocket Nozzle Cooling

A nuclear-rocket regenerative-cooling analysis was conducted over a range of reactor power of 46 to 1600 megawatts and is summarized herein. Although the propellant (hydrogen) is characterized by a large heat-sink capacity, an analysis of the local heat-flux capability of the coolant at the nozzle throat indicated that, for conventional values of system pressure drop, the cooling capability was inadequate to maintain a selected wall temperature of 1440 R. Several techniques for improving the cooling capability were discussed, for example, high pressure drop, high wall temperature, refractory wall coatings, thin highly conductive walls, and film cooling. In any specific design a combination of methods will probably be utilized to achieve successful cooling.

Robbins, William H.↗

Analysis of Turbulent Flow and Heat Transfer in Noncircular Passages

Previous work on turbulent heat transfer and flow in tubes was generalized and applied to flow in non-circular passages of equilateral triangular and square cross section. Expressions for eddy diffusivity that had been verified for flow and heat transfer in tubes were assumed to apply in general along lines normal to a wall. Velocity distributions, wall shear-stress distributions, and friction factors, as well as wall heat-transfer distributions, wall temperature distributions, and average heat-transfer coefficients were calculated. In addition, results from a previous analysis for axial flow between rods were compared with new experimental data. For calculating wall temperature distributions, uniform heat generation in the passage wall and uniform heat transfer at the outer surface were assumed. The application of the results is restricted to moderately small peripheral wall temperature variations. Calculations were made for Reynolds numbers from 20,000 to 900,000 and Prandtl numbers from 0.73 to 300. Results show that velocities, shear stresses, and heat transfer in the region near the corner were lower than average values and were zero at the corner. Friction factors and average Nusselt numbers were lower than in a tube.

Taylor, Maynard F.↗

Experiments with phase change thermal energy storage canisters for Space Station Freedom

The solar dynamic power module proposed for the Space Station Freedom (SSF) uses the heat of fusion of a phase change material (PCM) to efficiently store thermal energy for use during eclipse periods. The PCM, a LiF-20CaF2 salt, is contained in annular, metal canisters located in a heat receiver at the focus of a solar concentrator. PCM canister ground-based experiments and analytical heat transfer studies are discussed. The hardware, test procedures, and test results from these experiments are discussed. After more than 900 simulated SSF orbital cycles, no canister cracks or leaks were observed and all data were successfully collected. The effect of 1-g test orientation on canister wall temperatures was generally small while void position was strongly dependent on test orientation and canister cooling. In one test orientation, alternating wall temperature data were measured that supports an earlier theory of oscillating vortex flow in the PCM melt. Analytical canister wall temperatures compared very favorably with experimental temperature data. This illustrates that ground-based canister thermal performance can be predicted well by analyses that employ straight-forward, engineering models of void behavior and liquid PCM free convection.

Kerslake, Thomas W.↗

Deposit formation in hydrocarbon rocket fuels

An experimental program was conducted to study deposit formation in hydrocarbon fuels under flow conditions that exist in high-pressure, rocket engine cooling systems. A high pressure fuel coking test apparatus was designed and developed and was used to evaluate thermal decomposition (coking) limits and carbon deposition rates in heated copper tubes for two hydrocarbon rocket fuels, RP-1 and commercial-grade propane. Tests were also conducted using JP-7 and chemically-pure propane as being representative of more refined cuts of the baseline fuels. A parametric evaluation of fuel thermal stability was performed at pressures of 136 atm to 340 atm, bulk fuel velocities in the range 6 to 30 m/sec, and tube wall temperatures in the range 422 to 811 K. Results indicated that substantial deposit formation occurs with RP-1 fuel at wall temperatures between 600 and 800 K, with peak deposit formation occurring near 700 K. No improvements were obtained when deoxygenated JP-7 fuel was substituted for RP-1. The carbon deposition rates for the propane fuels were generally higher than those obtained for either of the kerosene fuels at any given wall temperature. There appeared to be little difference between commercial-grade and chemically-pure propane with regard to type and quantity of deposit. Results of tests conducted with RP-1 indicated that the rate of deposit formation increased slightly with pressure over the range 136 atm to 340 atm. Finally, lating the inside wall of the tubes with nickel was found to significantly reduce carbon deposition rates for RP-1 fuel.

Roback, R.↗

Influence of thermal boundary conditions on heat transfer from a cylinder in cross flow

Local heat transfer data over the leading surface of a cylinder in crossflow were obtained for a Reynolds number range of 50,000. The cylinder was operated at both uniform-wall-temperature and uniform-heat-flux thermal ance of 80 deg from the front stagnation point, the uniform-wall-temperature heat transfer coefficients were as much as 66 percent lower than the uniform-heat-flux data. Between the stagnation point and 60 deg around the cylinder, there were no significant differences in the data. This region of the cylinder is within the cylindrical curvature region of the front end of a real turbine so it was concluded that either thermal boundary condition could be used to model turbine flow over that region of the blade. Results of evaluating the exponent x in the fundamental relationship Nu=f(Re) sup x, which is used in data correlation show the exponent varies as a function of local position on the cylinder even in the laminar flow region. The value of x increases linearly from 0.50 at the stagnation point to 0.59 at 60 deg around the cylinder. This linear trend continued into the separation region at 80 deg for the uniform-wall-temperature data, but x increased markedly in the separation region for the uniform-heat-flux data.

Papell, S. S.↗

Heat transfer tests of a 0.0175-scale space shuttle orbiter model (29-0) to determine the effect of surface temperature on boundary layer transition at Mach 8.0 in the AEDC VKF tunnel B (test OH4A)

Wind tunnel tests were conducted to determine the heat transfer characteristics of a 0.0175-scale model of the space shuttle orbiter and to analyze the effect of wall temperature on the point of boundary layer transition. The tests were conducted at Mach 8.0 over a range of Reynolds numbers from 1.0 to 3.7 million per foot. Two regions of initial model wall temperature were investigated. Eighteen runs were obtained at each region to support the test objectives. Tabulated data are presented along with a description of the test procedure. Preliminary data indicated that the initial model wall temperature did not obviously affect the point of boundary layer transition.

Foust, J. W.↗

Chill Down Process of Hydrogen Transport Pipelines

A pseudo-steady model has been developed to predict the chilldown history of pipe wall temperature in the horizontal transport pipeline for cryogenic fluids. A new film boiling heat transfer model is developed by incorporating the stratified flow structure for cryogenic chilldown. A modified nucleate boiling heat transfer correlation for cryogenic chilldown process inside a horizontal pipe is proposed. The efficacy of the correlations is assessed by comparing the model predictions with measured values of wall temperature in several azimuthal positions in a well controlled experiment by Chung et al. (2004). The computed pipe wall temperature histories match well with the measured results. The present model captures important features of thermal interaction between the pipe wall and the cryogenic fluid, provides a simple and robust platform for predicting pipe wall chilldown history in long horizontal pipe at relatively low computational cost, and builds a foundation to incorporate the two-phase hydrodynamic interaction in the chilldown process.

Mei, Renwei↗

Heat transfer in laminar wall boundary layer within noncentered unsteady expansion wave

The paper summarizes results of theoretical and experimental investigations of wall temperature change and heat transfer in the laminar boundary layer formed within noncentered unsteady expansion waves in shock tubes. The study is restricted to a class of noncentered plane waves which have one key feature in common with centered waves, i.e., the first derivatives of the inviscid flow quantities have values or are discontinuous at the wavehead. The wall temperature is calculated implicitly by matching the local heat transfer rates of gas and wall thermal boundary layers. Experimentally, the wall temperature was measured using a thin-film resistance thermometer and heat transfer was then deduced using a one-dimensional unsteady heat conduction equation.

Srinivasan, G.↗

Modeling a Packed Bed Reactor Utilizing the Sabatier Process

A numerical model is being developed using Python which characterizes the conversion and temperature profiles of a packed bed reactor (PBR) that utilizes the Sabatier process; the reaction produces methane and water from carbon dioxide and hydrogen. While the specific kinetics of the Sabatier reaction on the RuAl2O3 catalyst pellets are unknown, an empirical reaction rate equation1 is used for the overall reaction. As this reaction is highly exothermic, proper thermal control is of the utmost importance to ensure maximum conversion and to avoid reactor runaway. It is therefore necessary to determine what wall temperature profile will ensure safe and efficient operation of the reactor. This wall temperature will be maintained by active thermal controls on the outer surface of the reactor. Two cylindrical PBRs are currently being tested experimentally and will be used for validation of the Python model. They are similar in design except one of them is larger and incorporates a preheat loop by feeding the reactant gas through a pipe along the center of the catalyst bed. The further complexity of adding a preheat pipe to the model to mimic the larger reactor is yet to be implemented and validated; preliminary validation is done using the smaller PBR with no reactant preheating. When mapping experimental values of the wall temperature from the smaller PBR into the Python model, a good approximation of the total conversion and temperature profile has been achieved. A separate CFD model incorporates more complex three-dimensional effects by including the solid catalyst pellets within the domain. The goal is to improve the Python model to the point where the results of other reactor geometry can be reasonably predicted relatively quickly when compared to the much more computationally expensive CFD approach. Once a reactor size is narrowed down using the Python approach, CFD will be used to generate a more thorough prediction of the reactors performance.

Reactor↗

Inviscid-viscous interaction on triple-deck scales in a hypersonic flow with strong wall cooling

The influence of wall temperatures on the flow structure in a region near a laminar separation is presently studied on the triple-deck scales, for the case of a high supersonic flow's inviscid-viscous interactions. A critical wall-temperature range is identified whose lower deck pressure-displacement relation departs from that of the classical formulation; below it, the pressure-displacement relation undergoes still greater transformations in conjunction with drastic scale-changes in the triple deck. The reduced lower-deck problem falls into supercritical, transcritical, and subcritical domains. A computational study is conducted for the compressive free-interaction solutions, and solutions are obtained for a sharp-corner ramp in the three wall-temperature ranges.

Brown, S. N.↗

A Laboratory Model of a Hydrogen/Oxygen Engine for Combustion and Nozzle Studies

A small laboratory diagnostic thruster was developed to augment present low thrust chemical rocket optical and heat flux diagnostics at the NASA Lewis Research Center. The objective of this work was to evaluate approaches for the use of temperature and pressure sensors for the investigation of low thrust rocket flow fields. The nominal engine thrust was 110 N. Tests were performed at chamber pressures of about 255 kPa, 370 kPa, and 500 kPa with oxidizer to fuel mixture ratios between 4.0 and 8.0. Two gaseous hydrogen/gaseous oxygen injector designs were tested with 60 percent and 75 percent fuel film cooling. The thruster and instrumentation designs were proven to be effective via hot fire testing. The thruster diagnostics provided inner wall temperature and static pressure measurements which were compared to the thruster global performance data. For several operating conditions, the performance data exhibited unexpected trends which were correlated with changes in the axial wall temperature distribution. Azimuthal temperature distributions were found to be a function of operating conditions and hardware configuration. The static pressure profiles showed that no severe pressure gradients were present in the rocket. The results indicated that small differences in injector design can result in dramatically different thruster performance and wall temperature behavior, but that these injector effects may be overshadowed by operating at a high fuel film cooling rate.

Morren, Sybil Huang↗

Computation of full-coverage film-cooled airfoil temperatures by two methods and comparison with high heat flux data

Two methods were used to calculate the heat flux to full-coverage film cooled airfoils and, subsequently, the airfoil wall temperatures. The calculated wall temperatures were compared to measured temperatures obtained in the Hot Section Facility operating at real engine conditions. Gas temperatures and pressures up to 1900 K and 18 atm with a Reynolds number up to 1.9 million were investigated. Heat flux was calculated by the convective heat transfer coefficient adiabatic wall method and by the superposition method which incorporates the film injection effects in the heat transfer coefficient. The results of the comparison indicate the first method can predict the experimental data reasonably well. However, superposition overpredicted the heat flux to the airfoil without a significant modification of the turbulent Prandtl number. The results suggest that additional research is required to model the physics of full-coverage film cooling where there is significant temperature/density differences between the gas and the coolant.

Gladden, H. J.↗

Variation in Heat Transfer During Transient Heating of a Hemisphere at a Mach Number of 2

Convective heat-transfer tests were made on a 5-inch-diameter hemisphere to determine the variation of Stanton number with the ratio of wall temperature to total temperature. The tests were made at a nominal Mach number of 2 for stagnation temperatures of 760 deg R, 1,030 deg R, and 1,380 deg R. The model was constructed so that radiation effects and also streamwise conduction effects within the model skin were minimized. The results of the tests verified that these effects were small. Tests which were made with different masses of air inside the model to check for conduction effects to the internal air cavity showed these effects to be negligible. For laminar flow on the hemisphere, the Stanton number remained essentially constant as the ratio of wall temperature to total temperature increased. However, for fully established turbulent flow, the Stanton number at some stations decreased on the order of 50 percent as the ratio of wall temperature to total temperature increased. A theory which agreed fairly well with the trend of this decrease is shown for comparison.

English, Roland D.↗

Liquid Transfer Cryogenic Test Facility: Initial hydrogen and nitrogen no-vent fill data

The Liquid Transfer Cryogenic Test Facility is a versatile testbed for ground-based cryogenic fluid storage, handling, and transfer experimentation. The test rig contains two well instrumented tanks, and a third interchangeable tank, designed to accommodate liquid nitrogen or liquid hydrogen testing. The internal tank volumes are approx. 18, 5, and 1.2 cu. ft. Tank pressures can be varied from 2 to 30 psia. Preliminary no vent fill tests with nitrogen and hydrogen were successfully completed with the test rig. Initial results indicate that no vent fills of nitrogen above 90 percent full are achievable using this test configuration, in a 1-g environment, and with inlet liquid temperatures as high as 143 R, and an average tank wall temperature of nearly 300 R. This inlet temperature corresponds to a saturation pressure of 19 psia for nitrogen. Hydrogen proved considerably more difficult to transfer between tanks without venting. The highest temperature conditions resulting in a fill level greater than 90 percent were with an inlet liquid temperature of 34 R, and an estimated tank wall temperature of slightly more than 100 R. Saturation pressure for hydrogen at this inlet temperature is 10 psia. All preliminary no vent fill tests were performed with a top mounted full cone nozzle for liquid injection. The nozzle produces a 120 degree conical droplet spray at a differential pressure of 10 psi. Pressure in the receiving tank was held to less than 30 psia for all tests.

Moran, Matthew E.↗

Model wall and recovery temperature effects on experimental heat transfer data analysis

Basic analytical procedures are used to illustrate, both qualitatively and quantitatively, the relative impact upon heat transfer data analysis of certain factors which may affect the accuracy of experimental heat transfer data. Inaccurate knowledge of adiabatic wall conditions results in a corresponding inaccuracy in the measured heat transfer coefficient. The magnitude of the resulting error is extreme for data obtained at wall temperatures approaching the adiabatic condition. High model wall temperatures and wall temperature gradients affect the level and distribution of heat transfer to an experimental model. The significance of each of these factors is examined and its impact upon heat transfer data analysis is assessed.

Throckmorton, D. A.↗

Jet array impingement flow distributions and heat transfer characteristics. Effects of initial crossflow and nonuniform array geometry

Two-dimensional arrays of circular air jets impinging on a heat transfer surface parallel to the jet orifice plate are considered. The jet flow, after impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer surface. The configurations considered are intended to model those of interest in current and contemplated gas turbine airfoil midchord cooling applications. The effects of an initial crossflow which approaches the array through an upstream extension of the channel are considered. Flow distributions as well as heat transfer coefficients and adiabatic wall temperatures resolved to one streamwise hole spacing were measured as a function of the initial crossflow rate and temperature relative to the jet flow rate and temperature. Both Nusselt number profiles and dimensionless adiabatic wall temperature (effectiveness) profiles are presented and discussed. Special test results which show a significant reduction of jet orifice discharge coefficients owing to the effect of a confined crossflow are also presented, along with a flow distribution model which incorporates those effects. A nonuniform array flow distribution model is developed and validated.

Florschuetz, L. W.↗

Experimental evaluation of heat transfer on a 1030:1 area ratio rocket nozzle

A 1030:1 carbon steel, heat-sink nozzle was tested. The test conditions included a nominal chamber pressure of 2413 kN/sq m and a mixture ratio range of 2.78 to 5.49. The propellants were gaseous oxygen and gaseous hydrogen. Outer wall temperature measurements were used to calculate the inner wall temperature and the heat flux and heat rate to the nozzle at specified axial locations. The experimental heat fluxes were compared to those predicted by the Two-Dimensional Kinetics (TDK) computer model analysis program. When laminar boundary layer flow was assumed in the analysis, the predicted values were within 15% of the experimental values for the area ratios of 20 to 975. However, when turbulent boundary layer conditions were assumed, the predicted values were approximately 120% higher than the experimental values. A study was performed to determine if the conditions within the nozzle could sustain a laminar boundary layer. Using the flow properties predicted by TDK, the momentum-thickness Reynolds number was calculated, and the point of transition to turbulent flow was predicted. The predicted transition point was within 0.5 inches of the nozzle throat. Calculations of the acceleration parameter were then made to determine if the flow conditions could produce relaminarization of the boundary layer. It was determined that if the boundary layer flow was inclined to transition to turbulent, the acceleration conditions within the nozzle would tend to suppress turbulence and keep the flow laminar-like.

Kacynski, Kenneth J.↗