Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIRE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Search for a Sterile Neutrino in a 3+1 Framework using Wire-Cell Inclusive Charged-Current $\nu_e$ Selection with the BNB and NuMI beamlines in MicroBooNE

A search for a sterile neutrino is being carried out in the MicroBooNE experiment within the 3+1 (three flavors of active neutrinos + one flavor of sterile neutrino) framework using neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI). The sensitivity of this search is built upon high performance inclusive charged-current electron neutrino and muon neutrino event selections. The previous 3+1 sterile neutrino search using only BNB data, the cancellation between $\nu_{e}$ disappearance and $\nu_{e}$ appearance oscillations led to a reduced oscillation effect in the $\nu_{e}$ energy spectrum resulting in a degeneracy of the oscillation parameters. Such a degeneracy is shown to be mitigated by including the neutrino events from the NuMI beam. In this note, the prospect of a 3+1 oscillation analysis using both BNB and NuMI is reported, considerably improving the sensitivity to 3+1 neutrino oscillations.

43 PARTICLE ACCELERATORS↗

Feature Based Qualification (FBQ) of Wire Arc Additively Manufactured (WAAM) 17-4PH Martensitic Stainless Steels

The Department of Defense (DOD) programs of records desire to reduce the time and cost of the development and delivery loop in metal additive manufacturing (AM), including establishing forwarded AM capabilities. The success of these efforts relies on a robust and qualified process. To achieve this, the United States Army Combat Capabilities Development Command Ground Vehicle Systems Center Materials Engineering (GVME) needs to be able to quickly evaluate, test, and develop feedstocks, processes, and parts. This report is directed towards demonstrating the need for a framework for metal AM processes, defining and exploring geometries for metal AM process qualification, testing resultant deposition, and delivering actionable data.

36 MATERIALS SCIENCE↗

Production of Precursor Materials for the Development of Iron-Based Superconductor (IBS) Wire

The goal of this agreement will be devoted to the understanding of the radiation-induced defects landscape produced on irradiated bulk samples and of the intrinsic properties of the stoichometric phases with special regards to the difference interaction with multiple chemical additions and doping elements. Samples will be produced by ENEA Frascati per Fermilab specifications and then shipped to Fermilab for the characterization testing and the execution of irradiation experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pairing Simulation with Uncertainty Quantification for Exploding Wire Tests

In a 2025 SAND report by Carnes et al., it was observed that experimental and model results were not in agreement, especially peak voltage, and time of peak, for gold, with observed disagreements of up to 40%. In this work, we investigate whether other sources of uncertainty in the model can explain this disagreement between experiment and model.

Mendoza, Hector Javier [Sandia National Laboratori↗

The potential of wire arc directed energy deposition

A diverse team of materials scientists, systems engineers and computational scientists at the Manufacturing Demonstration Facility at Oak Ridge National Laboratory (ORNL) is working closely with industry to employ WA-DED to transform the current manufacturing supply chains and change industry perception of metal-AM-fabricated components.

36 MATERIALS SCIENCE↗

Elimination LArTPC Simulation Uncertainty With Modifcations to TPC Wire Waveforms

This paper introduces a novel approach to reducing systematic uncertainties in LArTPC detector simulations, which arise from known detector effects that are challenging and computationally intensive to model. The proposed method involves modifying simulated waveforms based on observed discrepancies in ionization signals from the TPC between actual data and simulations. This approach reduces the sensitivity to detailed detector modeling and decreases the computational resources required for accurate simulations.

Mktchyan, Karen↗

Ultra-low magnetization and hysteresis loss in APC Nb 3 Sn superconductors

For the accelerator magnets of the next hadron collider, reducing superconductor persistent-current magnetization is not only important for achieving the desired field quality, but also crucial for its sustainability because the magnetization loss is the major heat load to the magnet cold mass. For conventional Nb 3 Sn conductors this requires reduction of effective subelement size (D eff ). For the restacked-rod-process (RRP ® ) conductors a physical subelement size (D sub ) as small as 35 µm (corresponding to a D eff close to 45 µm) can be reached, but at a significant price in J c . Another way to reduce the magnetization is by introducing artificial pinning centers (APC) using the internal oxidation approach. APC conductors outperform conventional Nb 3 Sn wires in two aspects: 1) higher J c at high fields, and 2) much lower J c and magnetization at low fields (e.g. below 5 T). Here, in this work we explored the fabricability of APC wires with small D sub . A 180-stack APC wire was produced and drawn to 0.7- and 0.5 mm diameters with good quality, with D sub s of 34 and 24 µm (D eff s of 36 and 25 µm), respectively. For the 34 µm-D sub wire, its non-Cu J c is higher than that of an RRP ® wire used for the High-Luminosity Large Hadron Collider (HL-LHC) project above 13 T (e.g. 36% higher at 4.2 K, 18 T), while its non-Cu magnetization at 1 T, ΔM(1 T), is only 29% of the RRP ® wire. Its non-Cu hysteresis loss for a cycle between 1 and 14 T, Q h (1–14 T), is 37% of the RRP ® wire. For the 24 µm-D sub wire, its non-Cu J c surpasses the HL-LHC RRP ® wire above 17.5 T, while its ΔM(1 T) and Q h (1–14 T) are only 17% and 23% of the RRP® wire, respectively. Its non-Cu Q h (±3 T) even meets the specification of the International Thermonuclear Experimental Reactor project.

Xu, X [Fermi National Accelerator Laboratory (FNAL↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗