Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waste Acceptance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Air passivation of metal hydride beds for waste disposal

One waste acceptance criteria for hydride bed waste disposal is that the bed be non-pyrophoric. Batch-wise air ingress tests were performed which determined the amount of air consumed by a metal hydride bed. A desorbed, 4.4 kg titanium prototype hydride storage vessel (HSV) produced a 4.4 deg.C internal temperature rise upon the first air exposure cycle and a 0.1 deg.C temperature rise upon a second air exposure. A total of 346 sec air was consumed by the bed (0.08 sec per gram Ti). A desorbed, 9.66 kg LaNi{sub 4.25}Al{sub 0.75} prototype storage bed experienced larger temperature rises over successive cycles of air ingress and evacuation. The cycles were performed over a period of days with the bed effectively passivated after the 12. cycle. Nine to ten STP-L of air reacted with the bed producing both oxidized metal and water. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned From Decommissioning B411 Decontamination Centre at Whiteshell Laboratories - 18211

Whiteshell Laboratories, located in Manitoba, Canada, provided research facilities for the Canadian nuclear industry since the early 1960's. The facility was centered on the largest organically cooled, heavy water moderated nuclear reactor in the world, the WR-1. It is now operated by Canadian Nuclear Laboratories (CNL) and is the first major decommissioning project of a nuclear research establishment in Canada. One of the major projects to support the closure of Whiteshell Laboratories (WL) is the decommissioning and demolition of the Building 411 (B411) Decontamination Centre, which provided a decontamination service for maintaining research and development of experimental rigs, equipment and tools in a safe usable state. It also provided a laundry service for radioactively contaminated clothing. The team successfully self-performed their first demolition of a nuclear facility, but not without challenges. The baseline decommissioning strategy assumed most of the facility would meet unconditional clearance levels; however when characterization revealed the extent of contamination exceeded initial assumptions projected from process knowledge, in conjunction with resource challenges and a waste disposal pathway not firmly established, active remediation of the facility was undertaken. With an unknown waste acceptance criteria for the future waste disposal facility, sludge that had accumulated in a tank used to collect xylene and organic coolant from contaminated tools and equipment and the selection of appropriate waste packages for waste storage, transportation and disposal forced the project team to adjust their demolition timeline. This, coupled with developing an open air demolition plan and managing an uncertain end state criteria, were just some of the major tasks the team successfully navigated. The impact on both schedule and cost performance caused by the change in strategy, and the lessons learned experienced by the WL Decommissioning Project Team that are being applied as the Whiteshell Laboratories Closure Project (WLCP) moves forward with the next major decommissioning challenge, are highlighted in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological Verification for the Remediation of LLRW at the Port Granby Project - 19210

The Port Granby Project is part of the Port Hope Area Initiative (PHAI) that Canadian Nuclear Laboratory (CNL) is using to manage long-term historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. Port Granby remediation scope includes constructing a new, secure long-term waste management facility (LTWMF) and supporting infrastructure and excavating and relocating LLRW and marginally contaminated soil from the Port Granby Waste Management Facility (PGWMF) which accepted waste until the 1980's to the newly constructed LTWMF. The PGWMF contains an estimated 450,000 cubic meters of LLRW deposited in unmarked and unlined trenches throughout the southern portion of the site that borders Lake Ontario. Project requirements include excavating contaminated material, verifying that the trench bottoms are below action levels using Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance, and final restoration. This paper describes challenges of meeting remediation verification requirements using traditional field and laboratory confirmation methods in areas of deep trench areas located in rugged terrain with ponded water and mud and presents a process that has expedited the traditional MARSSIM method for verification with greater productivity, and with enhanced safety and reliability as compared to the use of traditional methods alone. This enhanced process has been successfully employed for in-situ verification so that the excavated area can be backfilled and returned to a vegetative state. This enhanced process has been examined by federal regulatory staff through the course of their onsite audits and outcomes from these examinations have all been positive. The method involves a visual inspection and traditional walkover of the area to identify any areas with radiation measurements above the region's background followed by a full area survey performed using Wood's proprietary Orion ScanPlotSM system. The ScanPlotSM data is evaluated, mapped and overlaid on top of an aerial image of the surveyed area allowing remaining radiological material at surface or near surface to be quickly and easily identified for removal. Field staff then collect soil samples from evenly distributed points within the surveyed area and field screen the samples using an X-ray fluorescence (XRF) analysis for the three primary contaminates of potential concern (CoPCs) (arsenic, uranium and lead) that are indicative of the historical contamination. Samples passing XRF field screening are packaged and sent to a local laboratory for a full suite of analyses and checked against the CoPC list to assess whether the soil matches the profile for nearby native soils and passes the remediation goals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Port Hope Are Initiative Port Granby Project - Water Management in Extreme Weather Conditions - 19257

The Port Granby Project is part of the Port Hope Area Initiative (PHAI) through which Canadian Nuclear Laboratory (CNL) is managing long-term historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. Port Granby remediation scope includes 1) constructing a new, secure long-term waste management facility (LTWMF) and supporting infrastructure, and 2) excavating and relocating LLRW and marginally contaminated soil from the Port Granby Waste Management Facility (PGWMF), which accepted waste until the 1980's, to the newly constructed LTWMF. This paper provides an overview of the challenges of water management (control of storm and groundwater at the LTWMF and PGWMF) on a large-scale construction project with changing and unpredictable weather patterns. Consistent with increased observations of extreme weather events, over two consecutive construction seasons, weather changed from one of the driest on record (high temperatures, dry conditions and strong wind) to one of the wettest on record (short duration high-intensity rainfall that flooded the LTWMF, excavations and on-site PGWMF and LTWMF retention ponds). This paper describes the collaborative approach among Wood (Constructor), AECOM (Engineer of Record), and CNL to adjust to extremes in weather to control dust and excessive water during construction. The summer of 2016, one of the driest summers on record in southern Ontario, was followed by one of the wettest in 2017. In 2016, the project team used water from the uncontaminated on-site storm water ponds, applied a polymer product for dust control across the site to augment water applications, obtained a Permit to Take Water from the provincial government to pump water from Lake Ontario, procured large tanks for storage of Lake Ontario water to meet peak demand, and retained additional water trucks/operators for day to day site operations. In stark contrast, to accommodate heavy rains in 2017 the project team installed ∼6 million liter aboveground storage tanks with secondary containment for contaminated water storage; procured 100+ mobile water storage tanks to supplement the on-site storage, utilized LTWMF cells sumps, excavations and retention ponds to store and manage onsite water; and adjusted additional staff resources (more staff and longer shifts) during anticipated periods of high-intensity rainfall, at times managing water around the clock. Recognizing the need to minimize the release of contaminated soil and water from the construction site at all times, these efforts illustrate the importance of anticipating and reacting to extreme weather events on a more regular basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-level radioactive waste management: transitioning to off-site disposal at Los Alamos National Laboratory

Facing the closure of nearly all on-site management and disposal capability for low-level radioactive waste (LLW), Los Alamos National Laboratory (LANL) is making ready to ship the majority of LLW off-site. In order to ship off-site, waste must meet the Treatment, Storage, and Disposal Facility's (TSDF) Waste Acceptance Criteria (WAC). In preparation, LANL's waste management organization must ensure LANL waste generators characterize and package waste compliantly and waste characterization documentation is complete and accurate. Key challenges that must be addressed to successfully make the shift to off-site disposal of LLW include improving the detail, accuracy, and quality of process knowledge (PK) and acceptable knowledge (AK) documentation, training waste generators and waste management staff on the higher standard of data quality and expectations, improved WAC compliance for off-site facilities, and enhanced quality assurance throughout the process. Certification of LANL generators will allow direct off-site shipping of LLW from their facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification Process for Idaho HLW Calcine - 18433

The majority of the liquid wastes produced from reprocessing of several types of spent nuclear fuel at the Department of energy's (DOE) Idaho site have been volume reduced by calcination. The resulting ∼155,600 ft{sup 3} of calcined waste is stored in 43 shielded stainless steel bins, which have a 500-year design life. The calcined material is both a high-level waste and a RCRA hazardous waste, which complicates treatment and disposal options. In addition to a potential direct disposal option, treatment options that have been considered include steam reforming, hot isostatic pressing (HIP), and vitrification. This paper describes testing and evaluation of a vitrification option for the calcine. Vitrification to produce a borosilicate glass has the advantage that it is the only treatment that provides a waste form that meets the current HLW repository waste acceptance criteria. It is therefore the lowest risk option in terms of regulatory and legislative concerns. The present work addressed several key questions: (i) Calcine waste loadings in glass, which determine the number of HLW canisters produced and the required glass production rate (throughput) for the system design; (ii) Melt rate per unit glass pool surface area of the melter, which determines the sizing of the vitrification system; and (iii) The ability to meet waste form acceptance requirements (PCT and TCLP) while achieving reasonable waste loadings. These are issues of fundamental importance to the sizing estimates for the unit operations and overall flow-sheet and they, therefore, directly impact the cost and schedule estimates. Fully compliant, high-waste-loading glasses were developed for two of the four Idaho calcine wastes. The results demonstrate that waste loadings of 35 wt% waste oxides are achievable for the two alumina calcines and about 30 wt% is achievable for the two zirconia calcines. Testing of these formulations in a joule-heated ceramic melter showed glass production rates of over 5000 kg/(m2/d) for the Alumina calcine and over 8500 kg/(m{sup 2}/d) for the Zirconium-Na Blend calcine. These extremely high production rates translate directly into smaller system size and shorter mission duration and, therefore, reduced costs. Based on these results, a preliminary design for the full-scale vitrification system was developed. The system consists of waste receipt, vitrification, off-gas treatment, and canister sealing and decontamination equipment. The calcine is blended with the appropriate glass forming chemicals (or glass frit) and fed to the melter as a solid stream. The melter has a glass pool surface area of about 2.5 m{sup 2} and is equipped with a bubbling system to increase processing rates. Glass production rates of about 6 metric tons per day are projected. The vitrification system would be installed into the existing Idaho Waste Treatment Unit Facility (IWTU) so that no new facilities are required to house the treatment system, thus greatly reducing overall cost, duration, and risk. The system would be designed to treat all of the calcine waste within a period of 12 years at an operating efficiency of 80%, producing a total of about 8500 canisters each weighing two metric tons. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low Activity Waste Pretreatment System with actual Hanford tank waste. Crystalline silicotitanate (CST) ion exchange media is planned to be used to remove cesium (137Cs) from the aqueous phases of the tank wastes. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Removal of Cs from these wastes is an important processing step in preparing the waste for long-term safe storage. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using CST. Column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Feed was processed until the lag column effluent reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations), at which point, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected lead column samples were analyzed to assess particular metal analyte load characteristics. Results of these analyses will be discussed.

cesium exchange, Hanford tank waste, ion exchange↗

Solidified Organics Testing

The Radiochemical Engineering Development Center currently has plutonium-containing liquid organic waste that must be solidified before final disposal as solid debris waste. The documented safety analysis for the Radiochemical Engineering Development Center limits the amount of plutonium that can be released from solid debris waste forms during a fire scenario, which is less than 10 -4 airborne release fraction. Experimental results for plutonium release fractions from burning various materials has been compiled by the Department of Energy [DOE, 1994]. Combustion of organic liquids gave an average airborne release fraction of 6 × 10 -3 and combustion of surface-contaminated solids (paper, plastic, etc.) gave an average airborne release fraction of 5 × 10 -4 . Burning of 30% tri- n -butyl phosphate (TBP) in kerosene gave cerium release fractions of 5.6–7.7 × 10 -3 [Mishima and Schwendiman, 1973]. Earlier testing had evaluated many different grout-based formulations to solidify plutonium-containing organic waste liquids, and the ones used in these tests were shown to produce monolithic, fairly homogeneous solids. Each of the waste forms tested would meet the waste acceptance criteria for disposal at the Waste Isolation Pilot Plant as transuranic waste, but there were questions about whether they would meet the plutonium release criteria during a fire. The purpose of the work described here was to quantify the airborne release fraction for cerium, as a surrogate for plutonium, in these proposed waste forms. Cerium is often used as a simulant for plutonium in bench-scale testing, and cerium nitrate hexahydrate [Ce (NO 3 ) 3 ·6H 2 O] was added to the organic solutions that were solidified to prepare the surrogate waste forms for these tests. The waste forms were subjected to the designated fire scenario of 600ºC for 1 hour, and any cerium in the off-gas was trapped using a quartz filter followed by a scrubber containing 0.1 M NaOH, which is the same as used by Mishima and Schwendiman, [1973].

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Reportable Radionuclides for Defense Waste Processing Facility (DWPF) Sludge Batch 10 (Macrobatch 12)

Savannah River National Laboratory (SRNL) was tasked with the radionuclide characterization of the Sludge Batch 10 (SB10) Tank 40 sample (HTF-40-23-24) in accordance with requirements for reporting the Waste Acceptance Product Specifications (WAPS). The Defense Waste Processing Facility (DWPF) is required to report all radionuclides with half-lives greater than ten years and which comprise greater than 0.05% of the total activity inventory for a given waste form at certain specified “index years”. DWPF complies with the requirements by considering the half-life requirement (t1/2 > 10 years) and radionuclides with concentrations greater than 0.01% of the total inventory from the approximate time of production through 1,100 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Audit Report on "Waste Processing and Recovery Act Acceleration Efforts for Contact-Handled Transuranic Waste at the Hanford Site"

The Department of Energy's Office of Environmental Management's (EM), Richland Operations Office (Richland), is responsible for disposing of the Hanford Site's (Hanford) transuranic (TRU) waste, including nearly 12,000 cubic meters of radioactive contact-handled TRU wastes. Prior to disposing of this waste at the Department's Waste Isolation Pilot Plant (WIPP), Richland must certify that it meets WIPP's waste acceptance criteria. To be certified, the waste must be characterized, screened for prohibited items, treated (if necessary) and placed into a satisfactory disposal container. In a February 2008 amendment to an existing Record of Decision (Decision), the Department announced its plan to ship up to 8,764 cubic meters of contact-handled TRU waste from Hanford and other waste generator sites to the Advanced Mixed Waste Treatment Project (AMWTP) at Idaho's National Laboratory (INL) for processing and certification prior to disposal at WIPP. The Department decided to maximize the use of the AMWTP's automated waste processing capabilities to compact and, thereby, reduce the volume of contact-handled TRU waste. Compaction reduces the number of shipments and permits WIPP to more efficiently use its limited TRU waste disposal capacity. The Decision noted that the use of AMWTP would avoid the time and expense of establishing a processing capability at other sites. In May 2009, EM allocated $229 million of American Recovery and Reinvestment Act of 2009 (Recovery Act) funds to support Hanford's Solid Waste Program, including Hanford's contact-handled TRU waste. Besides providing jobs, these funds were intended to accelerate cleanup in the short term. We initiated this audit to determine whether the Department was effectively using Recovery Act funds to accelerate processing of Hanford's contact-handled TRU waste. Relying on the availability of Recovery Act funds, the Department changed course and approved an alternative plan that could increase costs by about $25 million by processing Hanford TRU-waste on-site rather than at AMWTP. Further, under the newly adopted alternative approach, the Department would fail to achieve the previously anticipated reductions in volume associated with the use of existing AMWTP waste compaction capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Andra's strategy and approach for operational safety of French underground facility Cigeo - 15127

According to the French Act on radioactive waste of 28 June 2006, Andra shall design a reversible repository. In response to this demand, Andra is developing the industrial project namely 'Cigeo', a reversible geological disposal facility for HLW and ILW located in Meuse/Haute-Marne. The previous safety cases of 2005, 2009 and 2012 give a sound basis to assess Cigeo's safety both for the operational and post-closure periods. Regarding operational safety, in this new stage of the project, the challenging issues for the preparation of the safety case are the following: - To adapt the various regulatory frameworks (nuclear and non-nuclear) to the underground facility - To design the underground facility and handling equipment's to reduce at first risks in the underground facility as such radioactive particles release, gas explosion, fire and co-activity and limit their consequence. - To establish waste acceptance criteria to be fulfilled by waste producers in line with operational safety and design options. The objective of the paper is to present the experience of Andra in operation safety of the underground facility of Cigeo. Operational safety for Cigeo is assessed as much as possible according to the existing French regulations and guidance for nuclear facilities. Indeed, compared to existing nuclear facilities, a geological repository is a specific case due to the existence of underground facilities with particularities such as: - ventilation management in a large scale underground facility, - fire risk management. As an input for the industrial design of Cigeo for operation, Andra defined a fire guidance and a specific reference safety guidance, based on the adaptation of the French nuclear regulatory texts for and when feasible to mines and tunnels regulatory texts and on its own experience gained through safety operational reports since 2005 and their reviews by the Safety Authority. - underground co-activity of nuclear operation with construction works. According to the common 'defense-in depth' principle for nuclear facilities, these guidelines for the industrial design of Cigeo for operation consider the successive levels of defense of: - Preventing the risk and its spreading by design and construction; - Detecting incidents and early fighting by design and operation dispositions (detection and control systems, survey procedure); - Controlling incidents and limiting of their consequences by safeguarding systems, specific procedures. At that stage, design options for Cigeo constitute an adequate response to the operational safety functions and requirements: - Two levels of containment are set up: the first one is ensured by the waste package, the second one is ensured from the surface facility to the disposal vaults by the transfer cask during the transfer of waste packages in the disposal vaults by the disposal vault itself and a nuclear ventilation with HEPA filter; - Favorable options for fire risk prevention and mitigation: transport system minimizing heat load (cable car for the transfer from the surface, electric transfer engines), twin access tunnels to ease fire-fighting and evacuation...; - Permanent complete physical separation of nuclear zone and construction zone (including ventilation systems). In practice, operation safety assessment of Cigeo, designed following the aforesaid reference safety guidelines, follows a common risk analysis (internal aggressions such as auxiliary losses, chemical and toxic risks, fall or collision, fire, human factors and external aggressions such as earthquake, air traffic, flooding) with the following steps: - Identification of the major risks and the design basis scenarios that have to be considered for dimensioning of the installations and the safety devices; - On the basis of these different situations, those who will have to be quantified are identified; one or more representative and envelop situations are chosen in order to evaluate robustness of the installation. Quantitative evaluation of these situations permits to: - identify the consequences on man, environment and installation, and in particular to gain confidence in the maintaining of the safety functions; - identify or define the technic and/or organisational dispositions classified as 'important elements for protection' (IEP); - Situations beyond dimensioning permit to verify the robustness of the installation. They permit, on one hand to identify possible complementary material or organisational dispositions; on the other hand, to define the 'hard core' i.e. structures, systems and components that permit to maintain the confinement function of radioactive substance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107 - 19104

Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low-Activity Waste Pretreatment System (LAWPS) with Hanford tank waste. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. Batch contact testing was performed to evaluate CST performance on tank waste prior to processing it in the LAWPS. Subsequently, column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Loading continued until the lag column reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and {sup 137}Cs concentrations). The Cs effluent from the lag column reached the WAC after processing half the feed volume. To keep the subsequent product effluent below the WAC, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected batch contact and lead column samples were analyzed to assess selected metal analyte load characteristics. Results of these analyses will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 36: Hot Topics in US Commercial Low-Level Waste Management

This panel focused on emerging issues in commercial LLW management in the US from the perspective of active members of the Low-Level Radioactive Waste Forum, Inc. State, compact, federal and industry officials shared their views on a variety of timely and significant topics related to low-level radioactive waste management, disposal and related issues. Session no. 36 Co-Chairs, Patricia Holahan and Daniel Shrum, introduced the panelists and provided a summary of the purpose of the session. This Panel Session focused on several current and emerging issues impacting the commercial Low-Level Radioactive Waste (LLRW) management in the US from the perspective of active members of the Low-Level Waste Forum, Inc., States, Compact, as well as Federal and nuclear industries. The panelists provided different perspectives on number of key issues such as: LLW disposal facility status and updates (e.g.; in terms of disposal capacity, plans, and waste acceptance conditions). The panelists also addressed waste disposal rates and potential impacts of ongoing regulatory developments by the NRC and the concerned States. Other timely topics pertaining to the revision of 10CFR Part 61, the Greater-than-Class C (GTCC) and Transuranic (TRU) waste, and Very Low-Level Waste (VLLW) disposal issues were also addressed at this Session. Panelists with presentations: Hot Topics in US Commercial LLW Management (Joe Weismann); Texas LLRW Compact (David Carlson); Texas Low-Level Radioactive Waste Disposal Compact Commission (John Salsman); Barnwell LLRW Disposal Facility (Benjamin Smith, Bill Carver)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Second Quarter 2013 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by Saltstone Facility Engineering (SFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For The Third Quarter 2013 Tank 50 WAC Slurry Sample

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For the Fourth Quarter 2013 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: SRR WAC targets or limits were met for all analyzed chemical and radioactive contaminants unless noted in this section. 59 Ni, 94 Nb, 247 Cm, 249 Cf, and 251 Cf are above the requested SRR target concentrations. However, they are below the detection limits established by SRNL. Norpar 13 and Isopar L have higher detection limits compared with the Saltstone WAC. The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility of these materials in aqueous solution, may not represent the concentrations of the analytes in Tank 50. The low insoluble solids content increases the measurement uncertainty for insoluble species. The semivolatile organic analysis (SVOA) method employed in the measurement of Norpar 13 and tributyl phosphate (TBP) has resulted in the erroneous reporting of a variety of small chain alcohols, including 4-methyl-3-hexanol and 5-methyl-3-hexanol, in previous quarterly sample reports. It has now been determined that these alcohols are an artifact of the sample preparation. Further work is being conducted in SRNL to delineate the conditions that produce these alcohols, and these findings will be reported separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the second quarter 2014 tank 50 WAC slurry sample chemical and radionuclide contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2014 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗