Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wolter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A far ultraviolet rocket-borne spectrograph

A sensitive spectrograph for rocket observations of celestial objects in the 910-1250A band is described. The instrument incorporates a variety of new technologies that allow unprecedented sensitivity in this difficult, but scientifically rewarding, band. It includes a diamond-turned Wolter-Schwarzschild Type II telescope, a conventional Rowland Circle spectrograph, and resistive anode/microchannel plate detectors. It has been launched twice from Woomera, Australia where it performed observations of SN1987A and discovered a new feature in the diffuse UV background.

Cash, Webster↗

Astronomical observations with normal incidence multilayer optics - Recent results and future prospects

High-resolution X-ray and EUV images of the solar corona have been obtained with two rocket-borne normal incidence Cassegrain multilayer telescopes. The Cassegrain images correspond to material at about 10 to the 6th K and about 80,000 K. Other images, at somewhat lower resolution, were obtained with Herschelian multilayer telescopes and Wolter-Schwarzschild hybrid grazing incidence/multilayer optical systems. The Cassegrain and Herschelian images are discussed emphasizing the analysis of polar plumes observed at the limb of the sun. The application of specific multilayer techniques to astronomical observations is discussed, emphasizing observations of the sun. Current efforts to develop a comprehensive Multi-Spectral Solar Telescope Array rocket instrument for the study of a wide variety of problems related to the solar atmosphere are reported.

Walker, Arthur B. C., Jr.↗

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.↗

X-ray optics. II - A technique for high resolution spectroscopy

A novel combination of optical elements and properties is combined to achieve high-spectral resolution using grazing incidence optics of modest quality. Analysis and ray tracing of examples show that using radial groove gratings at high blaze angles in the manner of an echelle spectrograph can provide high spectral resolution. This arrangement is compared to the conventional in-plane designs to show that the off-plane is superior in nearly every respect. Cross dispersion can be provided by the energy resolution of a CCD detector. Additional resolution can be squeezed from the system by strategic placement of gratings to take advantage of the azimuthal response of a Wolter X-ray optic.

Cash, Webster C., Jr.↗

High energy, high resolution X-ray optics

The scientific goals of X-ray astronomy are considered to evaluate the relative advantages of using classical Wolter-1 optics or using a different approach. The portion of the X-ray band over 10 keV is unexploited in the present X-ray optics technology, and focussing in this portion of the band is crucial because nonfocussed experiments are background limited. The basic design of 'hard' X-ray optics is described theoretically emphasizing the very small angles of incidence in the grazing-incidence optics. Optimization of the signal-to-noise ratio is found to occur at a finite angular resolution. In real applications, the effective area reduced by the efficiency of the two reflections is 80 percent at energies up to 40 keV, and the quality of the reflecting surface can be monitored to minimize scattering. Focussing optics are found to offer improvements in signal-to-noise as well as more effective scientific return because microelectronic focal-plane technology is employed.

Weisskopf, Martin C.↗

Aries x ray objective grating spectrograph

This investigation was initiated in June of 1983. An Aries payload involving a single Wolter 1 telescope was developed and flown under a previous contract and the objective of this work was to add two additional mirrors, nested inside of the then existing mirror and add 12 objective reflection gratings to convert the telescope into a spectrograph. A summary of major milestones in the investigation are given. Results of efforts under this contract prior to 1987 are presented in the form of four reprints of published papers attached to this report. Results of the gamma-ray research are also included in the form of an attached reprint. A summary of other work under the contract since 1987 is given.

Catura, R. C.↗

An EUV imaging spectrograph for high-resolution observations of the solar corona

An extreme ultraviolet (EUV) imaging spectrograph for the wavelength range from 235 to 450 A has been developed and used for resolution observations of the sun. The instrument incorporates a glancing incidence Wolter Type II Telescope and a near-normal incidence toroidal grating spectrograph to achieve near-stigmatic performance over this spectral range. The design of the spectrograph entrance aperture enables both stigmatic spectra with spectral resolution adequate to observe emission line profiles and spectroheliograms of restricted portions of the sun to be obtained concurrently. The design and performance of the instrument are described, and an overview of results obtained during a sounding rocket flight on May 5, 1989 is provided.

Neupert, Werner M.↗

Fabrication of a grazing incidence telescope by grinding and polishing techniques on aluminum

The paper describes the fabrication processes, by grinding and polishing, used in making the mirrors for a f/2.8 Wolter type-I grazing incidence telescope at Boulder (Colorado), together with testing procedure used to determine the quality of the images. All grinding and polishing is done on specially designed machine that consists of a horizontal spindle to hold and rotate the mirror and a stroke arm machine to push the various tools back and forth along the mirrors length. The progress is checked by means of the ronchi test during all grinding and polishing stages. Current measurements of the telescope's image quality give a FWHM measurement of 44 arcsec, with the goal set at 5-10 arcsec quality.

Gallagher, Dennis↗

X-ray testing of grazing incidence optics fabricated at the University of Colorado

An account is given of the methods and results of X-ray testing for the grazing-incidence optics of the F/5.73 Wolter Type I telescope, whose mirror had flown on a NASA sounding rocket in March, 1991. Attention is given to the tests of the inplane (full aperture) and offplane (apodized aperture) imaging response at 0.25-1.50 keV energies; correlations with surface figures are discussed.

Gallagher, Dennis↗

Multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992

The present volume on multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography discusses AXAF grazing incidence mirrors, the theory and high throughput optics of grazing incidence optics, multilayer mirror fabrication and characterization, and multilayer optics for X-ray projection lithography. Attention is given to the VETA-I X-ray detection system, a motion detection system for AXAF X-ray ground testing, image analysis of the AXAF VETA-I X-ray mirror, and optical constants from mirror reflectivities measured at synchrotrons. Topics discussed include the application of aberration theory to calculate encircled energy of Wolter I-II telescopes, W/C multilayers deposited on plastic films, nonspecular X-ray scattering from Si/Mo multilayers, and multilayer thin-film design as FUV polarizers. Also discussed are thin-film filter lifetesting results in the EUV, chromospheric and coronal observations with multilayer optics, present and future requirements of soft X-ray projection lithography, and the imaging Schwarzschild multilayer X-ray microscope.

Hoover, Richard B.↗

The AXAF VETA test - An overview

Results of a battery of X-ray tests on the AXAF Verification Engineering Test Article (VETA) X-ray optics which were performed shortly after their fabrication are presented. The optics, a paraboloid, and a hyperboloid in the classic Wolter-1 configuration are the outer mirrors of what is now the AXAF-I mission. The optical elements are each about 1.2 m in diameter and 0.8 m long. The principal proof that the optics met their specification was to demonstrate that the angular resolution was at least 0.5 arcsec. The final result was an angular resolution smaller than 0.25 arcsec.

Weisskopf, Martin C.↗

Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

Kellogg, E.↗

Synchrotron/crystal sample preparation

The Center for Applied Optics (CAO) of the University of Alabama in Huntsville (UAH) prepared this final report entitled 'Synchrotron/Crystal Sample Preparation' in completion of contract NAS8-38609, Delivery Order No. 53. Hughes Danbury Optical Systems (HDOS) is manufacturing the Advanced X-ray Astrophysics Facility (AXAF) mirrors. These thin-walled, grazing incidence, Wolter Type-1 mirrors, varying in diameter from 1.2 to 0.68 meters, must be ground and polished using state-of-the-art techniques in order to prevent undue stress due to damage or the presence of crystals and inclusions. The effect of crystals on the polishing and grinding process must also be understood. This involves coating special samples of Zerodur and measuring the reflectivity of the coatings in a synchrotron system. In order to gain the understanding needed on the effect of the Zerodur crystals by the grinding and polishing process, UAH prepared glass samples by cutting, grinding, etching, and polishing as required to meet specifications for witness bars for synchrotron measurements and for investigations of crystals embedded in Zerodur. UAH then characterized these samples for subsurface damage and surface roughness and figure.

Johnson, R. Barry↗

Investigate zero-stress replicated optics

The contracted activities for the procurement of 'Investigate Zero-Stress Replicated Optics' to support the AXAF-S x-ray spectrometer mirrors has been completed. To date four large Wolter I grazing incidence x-ray optical shells have been electroformed from nickel. The mirrors were fabricated utilizing each of two nickel alloy plated aluminum substrates twice. A wide variety of testing has been completed by NASA MSFC and UAH. This testing includes heat treatment control tests, subscale plating and fixture testing, alloy control of the electroless nickel, adhesion and release testing of the gold to electroless nickel, electroforming instrumentation and software and fabrication of subscale models. The full scale shells are one millimeter thick nickel electrodeposited over a thin gold layer which in turn has the optical surface on the inside. The optical surface is the replicate of the surface prepared on the substrate. Appendix I briefly outlines the fabrication process. Major objectives which were shared by UAH and MSFC include the design of facilities, equipment and tooling and procurement of materials and equipment. Process development followed with the fabrication of small scale pilot units. Procurement commenced immediately and equipment and materials were ordered to implement the fabrication of first surface full scale substrates (mandrels) and the second surface electroformed optical components. All principal objectives have been achieved. Inspection of the mirrors in visible and x-ray modes validates that the required performance and the quality can be achieved by an electroforming replication process. A very distinct progressive improvement has been achieved with each of the four mirrors produced. The final mirror exceeded the original goals and set an improved standard for flight hardware. The future goal of a 30 arc second resolution at 8 KEV x-ray appears to be achievable by this process when proper cleanliness and process control is utilized.

Engelhaupt, Darell↗

TransFit: Finite element analysis data fitting software

The Advanced X-Ray Astrophysics Facility (AXAF) mission support team has made extensive use of geometric ray tracing to analyze the performance of AXAF developmental and flight optics. One important aspect of this performance modeling is the incorporation of finite element analysis (FEA) data into the surface deformations of the optical elements. TransFit is software designed for the fitting of FEA data of Wolter I optical surface distortions with a continuous surface description which can then be used by SAO's analytic ray tracing software, currently OSAC (Optical Surface Analysis Code). The improved capabilities of Transfit over previous methods include bicubic spline fitting of FEA data to accommodate higher spatial frequency distortions, fitted data visualization for assessing the quality of fit, the ability to accommodate input data from three FEA codes plus other standard formats, and options for alignment of the model coordinate system with the ray trace coordinate system. TransFit uses the AnswerGarden graphical user interface (GUI) to edit input parameters and then access routines written in PV-WAVE, C, and FORTRAN to allow the user to interactively create, evaluate, and modify the fit. The topics covered include an introduction to TransFit: requirements, designs philosophy, and implementation; design specifics: modules, parameters, fitting algorithms, and data displays; a procedural example; verification of performance; future work; and appendices on online help and ray trace results of the verification section.

Freeman, Mark↗

AXAF-I ghost ray study: On orbit case

The problem of baffles for control of singly reflected (and nonreflected) ghost rays is considered. The theory of baffle design for Wolter Type I grazing incidence optics is reviewed, and a set of sample baffle parameters is obtained subject to the assumptions of nominal mirror figures and perfect manufacture and alignment of baffles. It is found that baffles forward of the optics (in the thermal precollimator) and between the mirror elements (at the CAP) are sufficient to allow the simultaneous ghost image and vignetting requirements to be satisfied for HRMA shells P1H1, P3H3, and P4H4. However, these baffles are not sufficient for the innermost shell P6H6; at best the requirements are slightly violated and there is no margin for tolerances. The addition of a baffle interior to the P6 space at an axial station about one third of the way forward from the aft end of the paraboloid will allow the ghost ray and vignetting requirements to be met. The minimum ghost ray angles and the vignetting angles are sensitive functions of the baffle positions and radii; tolerances of considerably better than 1 mm will be required. The sensitivities are coupled and correlated; further investigations should be undertaken in order to obtain baffle parameters which, combined with likely achievable tolerances, will minimize the risk of the vignetting/ghost ray requirements not being met. The lightweight carbon-epoxy composite used for thermal baffles has insufficient X-ray opacity to be a suitable material for construction of the controlling X-ray baffles; further study is needed to determine an appropriate material and to investigate its thermal and mechanical implications.

Gaetz, T. J.↗

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell↗

The Alignment Test System for AXAF-I's High Resolution Mirror Assembly

The AXAF-1 High Resolution Mirror Assembly (HRMA) consists of four nested mirror pairs of Wolter Type-1 grazing incidence optics. The HRMA assembly and alignment will take place in a vibration-isolated, cleanliness class 100, 18 meter high tower at an Eastman Kodak Company facility in Rochester, NY. Each mirror pair must be aligned such that its image is coma-free, and the four pairs must be aligned such that their images are coincident. In addition, both the HRMA optical axis and focal point must be precisely known with respect to physical references on the HRMA. The alignment of the HRMA mirrors is measured by the HRMA Alignment Test System (HATS), which is an integral part of the tower facility. The HATS is configured as a double-pass, autocollimating Hartmann test where each mirror aperture is scanned to determine the state of alignment. This paper will describe the design and operation of the HATS.

Waldman, Mark↗