Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Discovery of Thermonuclear (Type 1) X-ray Bursts in the X-ray Binary Swift J1858.6-0814 Observed with NICER and NuSTAR

Swift J1858.6–0814 is a recently discovered X-ray binary notable for extremely strong variability (by factors of >100 in soft X-rays) in its discovery state. We present the detection of five thermonuclear (Type I) X-ray bursts from Swift J1858.6–0814, implying that the compact object in the system is a neutron star (NS). Some of the bursts show photospheric radius expansion, so their peak flux can be used to estimate the distance to the system. The peak luminosity, and hence distance, can depend on several system parameters; for the most likely values, a high inclination and a helium atmosphere, D = 12.8+0.8−0.6 kpc, although systematic effects allow a conservative range of 9–18 kpc. Before one burst, we detect a QPO at 9.6 ± 0.5 mHz with a fractional rms amplitude of 2.2 ± 0.2 per cent (0.5–10 keV), likely due to marginally stable burning of helium; similar oscillations may be present before the other bursts but the light curves are not long enough to allow their detection. We also search for burst oscillations but do not detect any, with an upper limit in the best case of 15 per cent fractional amplitude (over 1–8 keV). Finally, we discuss the implications of the NS accretor and this distance on other inferences which have been made about the system. In particular, we find that Swift J1858.6–0814 was observed at super-Eddington luminosities at least during bright flares during the variable stage of its outburst.

D J K Buisson↗

Uhuru observations of 4U 1608-52 - The 'steady' X-ray source associated with the X-ray burst source in Norma

Data are presented for the X-ray source 4U 1608-52, summarizing its light curve, location, and spectral parameters. Evidence is presented showing that this source is the 'steady' X-ray counterpart of the X-ray burst source in Norma. The spectrum of the 'steady' source is compared with the spectrum observed during two bursts, and it is noted that there is substantially more low-energy absorption during the bursts. The 'steady' source spectral data are used to examine the optical data, and it is concluded that if the X-ray spectrum is thermal, then a globular-cluster counterpart probably would have been detected (whereas none has been). Further X-ray and optical observations are suggested for this source, since an optical identification may be central in determining whether all X-ray bursts have a common origin and if this origin requires a globular-cluster environment.

Tananbaum, H.↗

Complex Variations in X-ray Polarization in the X-ray pulsar LS V +44 17 / RX J0440.9+4431

We report on Imaging X-ray polarimetry explorer (IXPE) observations of the Be-transient X-ray pulsar LS V+44 17/RX J0440.9+4431 made at two luminosity levels during the giant outburst in January–February 2023. Considering the observed spectral variability and changes in the pulse profiles, the source was likely caught in supercritical and subcritical states with significantly different emission-region geometry, associated with the presence of accretion columns and hot spots, respectively. We focus here on the pulse-phase-resolved polarimetric analysis and find that the observed dependencies of the polarization degree and polarization angle (PA) on the pulse phase are indeed drastically different for the two observations. The observed differences, if interpreted within the framework of the rotating vector model (RVM), imply dramatic variations in the spin axis inclination, the position angle, and the magnetic colatitude by tens of degrees within the space of just a few days. We suggest that the apparent changes in the observed PA phase dependence are predominantly related to the presence of an unpulsed polarized component in addition to the polarized radiation associated with the pulsar itself. We then show that the observed PA phase dependence in both observations can be explained with a single set of RVM parameters defining the pulsar’s geometry. We also suggest that the additional polarized component is likely produced by scattering of the pulsar radiation in the equatorial disk wind.

RX J0440.9+4431↗

Gamma-ray and X-ray time profiles expected from a trap-plus-precipitation model for the 7 June 1980 and 27 April 1981 solar flares

Hard X-ray and prompt gamma-ray line emissions are the most direct signatures of, respectively, electron and ion acceleration during solar flares. The peak time of the gamma-ray emission for some events is delayed with respect to the peak time of the hard X-ray flux. These delays are either interpreted as evidence of a two-step acceleration process or as the result of the partial trapping and/or propagation of the particles from the acceleration region to the emission sites. It was shown earlier that hard X-ray and prompt gamma-ray line delays can be qualitatively reproduced in the frame of the latter hypothesis with models describing the time-dependent transport of energetic electrons and ions between these two sites. Here we focus on the close examination of the temporal evolution of X-ray and gamma-ray fluxes for the 7 June 1980 and 27 April 1981 events which exhibit delays between X-ray and gamma-ray maxima. The parameters of the ambient medium and of the accelerated particles are deduced for the two events and it is shown that the relative timing of X-ray and gamma-ray emissions is quantitatively reproduced in the present context.

Hulot, E.↗

X-ray and optical observations of X-ray-selected BL Laceratae objects

Results from several X-ray and optical observations of five X-ray-selected BL Lacertae objects are reported. X-ray light curves covering periods of up to 6 yr reveal that the X-ray flux from these objects does not show large-amplitude trends over this time scale. Variations of up to 2 mag have been observed in the optical. The soft X-ray spectra of three objects have been measured with the Exosat Medium Energy detectors. Energy spectral indices range between one and two. In one case (1E 1415.6 + 2557), evidence for photoelectric absorption in excess of that due to the local interstellar medium has been found. A new optical flare from 1E 1402.3 + 0416, with rise and decay time of order of a few weeks, has been detected.

Giommi, P.↗

The Gemini-Monoceros X-ray enhancement - A giant X-ray ring

A 1.5 deg spatial resolution map of the 1/4 KeV diffuse X-ray background enhancement in the Gemini and Monoceros constellations is found to show a circular ring-shaped emission feature with a diameter of 20 deg. The feature and possible X-ray contributions from the Mon OB1 association and neighboring supernova remnants are discussed. From 300 pc, the region has a radius of 50 pc, with an emitting electron density of 0.01 per cu cm. A shell of expanding neutral hydrogen and nonthermal radio spur is observed outside the ring with the X-ray emitting pulsar PSR 0656 + 14 lying close to the center of the ring. Origins of the ring are discussed, ruling out formation by the association Mon OB1. The ring is considered to be a field supernova remnant formed by the progenitor of the central pulsar, and providing constraints on theories of remnant evolution. This conclusion is found to agree with estimated supernova rates, and the absence of additional examples of this stage of evolution is an observational selection effect.

Nousek, J. A.↗

GRB 050117: Simultaneous Gamma-ray and X-ray Observations with the Swift Satellite

The Swift Gamma-Ray Burst Explorer performed its first autonomous, X-ray follow-up to a newly detected GRB on 2005 January 17, within 193 seconds of the burst trigger by the Swift Burst Alert Telescope. While the burst was still in progress, the X-ray Telescope obtained a position and an image for an un-catalogued X-ray source; simultaneous with the gamma-ray observation. The XRT observed flux during the prompt emission was 1.1 x 10(exp -8) ergs/sq cm/s in the 0.5-10 keV energy band. The emission in the X-ray band decreased by three orders of magnitude within 700 seconds, following the prompt emission. This is found to be consistent with the gamma-ray decay when extrapolated into the XRT energy band. During the following 6.3 hours, the XRT observed the afterglow in an automated sequence for an additional 947 seconds, until the burst became fully obscured by the Earth limb. A faint, extremely slowly decaying afterglow, alpha=-0.21, was detected. Finally, a break in the lightcurve occurred and the flux decayed with alpha<-1.2. The X-ray position triggered many follow-up observations: no optical afterglow could be confirmed, although a candidate was identified 3 arcsecs from the XRT position.

Hill, J. E.↗

First Flight of the X-Ray Polarimeter X-Calibur

X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built and tested a hard X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope with the goal of observing astrophysical sources. X-Calibur combines a low-Z Compton scatterer with a CZT detector assembly to measure the polarization of 20-60 keV X-rays making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. A I-day test. flight of the instrument was performed from Ft.Sumner, NM, In fall 2014. The sensitivity, performance and first results form the flight will be presented.

First Flight↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

Search for scattered X-ray halos around variable sources - The X-ray halo of Cygnus X-1

The results of a program to search for the presence of halos due to X-ray scattering by interstellar grains in the line-of-sight to variable X-ray sources are reported. As part of this program, four Einstein HRI images of Cyg X-1 were examined. The analysis technique exploits the intrinsic aperiodic variability of this source to map the point response function of the optics. Any scattered halo present will not reflect short-term central source time variability, since such variability is smoothed by differential time delays of order days. Thus, a residual, nonvariable component to the surface brightness distribution (comprising about 12 percent or more of the source flux) is interpreted as a scattered halo. The Cyg X-1 halo is consistent with those of other sources found in previous studies using different techniques. Comparison is also made with a scattering model and, despite uncertainties in source spectrum and distance, reasonable agreement with the observatons is found using a standard interstellar grain model. The potential of X-ray scattering as a probe of the properties of interstellar grains is demonstrated.

Bode, M. F.↗

Unsupervised machine learning for unbiased chemical classification in X-ray absorption spectroscopy and X-ray emission spectroscopy

Here we report a comprehensive computational study of unsupervised machine learning for extraction of chemically relevant information in X-ray absorption near edge structure (XANES) and in valence-to-core X-ray emission spectra (VtC-XES) for classification of a broad ensemble of sulphorganic molecules. By progressively decreasing the constraining assumptions of the unsupervised machine learning algorithm, moving from principal component analysis (PCA) to a variational autoencoder (VAE) to t-distributed stochastic neighbour embedding (t-SNE), we find improved sensitivity to steadily more refined chemical information. Surprisingly, when embedding the ensemble of spectra in merely two dimensions, t-SNE distinguishes not just oxidation state and general sulphur bonding environment but also the aromaticity of the bonding radical group with 87% accuracy as well as identifying even finer details in electronic structure within aromatic or aliphatic sub-classes. We find that the chemical information in XANES and VtC-XES is very similar in character and content, although they unexpectedly have different sensitivity within a given molecular class. We also discuss likely benefits from further effort with unsupervised machine learning and from the interplay between supervised and unsupervised machine learning for X-ray spectroscopies. Our overall results, i.e., the ability to reliably classify without user bias and to discover unexpected chemical signatures for XANES and VtC-XES, likely generalize to other systems as well as to other one-dimensional chemical spectroscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing X-ray Color Selection in Separating X-ray Binary Classes using Color-Color-Intensity Diagrams

X-ray binaries exhibit a wide range of properties but there are few accepted methods to determine the nature of the compact object. Color-Color-Intensity diagrams have been suggested as a means of distinguishing between systems containing black holes from those containing neutron stars. However, this technique has been verified with data from only one instrument (RXTE/ASM) with a single set of X-ray colors defined using data available only in pre-determined energy bands. We test a selection of X-ray colors with a more sensitive instrument to determine the reliability of this method. We use data from the MAXI/Gas Slit Camera, which allows users to specify energy-bands. We test X-ray colors that have been previously defined in the literature as well as ones that we define specifically in this paper. A representative set of systems are used to construct Color-Color-Intensity diagrams in each set of colors to determine which are best for separating different classes. For studying individual sources certain bands are more effective than others. For a specified energy range, the separation of soft states in black hole binaries was possible only where both soft and hard colors included information from the lowest energy band. We confirm that Color-Color-Intensity diagrams can distinguish between systems containing black holes or neutron stars in all X-ray colors tested; this suggests an universality in the accretion processes governing these different classes. We suggest possible physical processes driving different classes of X-ray binaries to different locations in Color-Color-Intensity diagrams.

N Islam↗

Reflectivity Around the Gold M-Edges of X-ray Reflector of the Soft X-Ray Telescope Onboard ASTRO-H

The X-ray astronomy satellite ASTRO-H are equipped with two equivalent soft X-ray telescopes (SXT-I and SXT-S) which cover the energy band 0.3-12 keV. The X-ray reflectors of the SXTs are coated with a gold monolayer by means of the replication technique. A series of gold M absorption edges in the 2-4 keV band causes complex structures in the energy response of the SXTs. In the same band, there are astrophysically important emission lines from Si, Ar and S. Since the SXS has unprecedentedly high spectral resolution, we have measured the reflectivity around the gold M-edges in an extremely fine energy pitch at the synchrotron radiation facility KEK PF BL11-B, with the 2 eV pitch in 2100 eV to 4100 eV band that covers the entire series of the absorption edges (M-I through M-V) at grazing incident angles to the reflectors of 0.5, 0.8, 1.0, 1.2, 1.4 degree, and with a finer pitch of 0.25 eV in the 2200 eV to 2350 eV band where the two deepest M-IV and M-V edges are included. In the resultant reflectivity curves, we have clearly identified the fine structures associated with all the M-edges. Using these data, we calculated atomic scattering factor f1 as a function of X-ray energy, with which we have built the mirror response function which can be applied to the Suzaku spectra. As a result, we have found that discrepancy of the spectral model to the Suzaku data of 4U1630-472 (a black hole transient) and the Crab nebula around the M-edges are significantly reduced from those with the official Suzaku response.

ASTRO-H↗

A Correlation Between the Intrinsic Brightness and Average Decay Rate of Gamma-Ray Burst X-Ray Afterglow Light Curves

We present a correlation between the average temporal decay (alpha X,avg, greater than 200 s) and early-time luminosity (LX,200 s) of X-ray afterglows of gamma-ray bursts as observed by the Swift X-ray Telescope. Both quantities are measured relative to a rest-frame time of 200 s after the gamma-ray trigger. The luminosity â€" average decay correlation does not depend on specific temporal behavior and contains one scale-independent quantity minimizing the role of selection effects. This is a complementary correlation to that discovered by Oates et al. in the optical light curves observed by the Swift Ultraviolet Optical Telescope. The correlation indicates that, on average, more luminous X-ray afterglows decay faster than less luminous ones, indicating some relative mechanism for energy dissipation. The X-ray and optical correlations are entirely consistent once corrections are applied and contamination is removed. We explore the possible biases introduced by different light-curve morphologies and observational selection effects, and how either geometrical effects or intrinsic properties of the central engine and jet could explain the observed correlation.

gamma-ray burst: general X-rays: burst↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

One-dimensional focusing X-ray telescope for stellar X-ray astronomy

A one-dimensional X-ray telescope of the Kirkpatrick-Baez design is described. The instrument consists of a grazing-incidence X-ray telescope and a multiwire proportional counter. The optics were provided with a gold reflecting surface to yield an energy response from below 0.25 to above 4.0 keV. The angular resolution of the system is 6 min by 9.5 deg over a 1.1 deg by 9.5 deg field of view.

Helava, H.↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Chandra X-Ray Observations of the Anomalous X-Ray Pulsar 1E 2259+58.6

We present X-ray imaging, timing, and phase resolved spectroscopy of the anomalous X-ray pulsar 1E 2259+58.6 using the Chandra X-ray Observatory. Time resolved X-ray spectra show no significant variation as a function of pulsar spin phase. The phase averaged spectrum is well described by a powerlaw plus blackbody model; we find no evidence for spectral features. We derive a spin period. We have detected a halo beyond the central source, possibly due to dust scattering in the ISM (interstellar matter).

Patel, Sandeep K.↗