Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Data Analysis of X-ray Panels Used in X-ray CT Scientific Instruments

This report is a follow-up study on M. Skeate’s study on System Drift Detection for Health Monitoring (Skeate, 2023). The following report highlights analyses of the panel’s behavior with extended use. This includes effects of burn-in on the panel from over-use and bad pixels (defined in Methodology.) Using data-forward statistical analyses across a sequence of scans, and given that the other conditions present in the data can be replicated, this study show that overtime use of panels does not affect bad pixel count. Also, I present conclusive evidence of a direct relationship between the regions of the panel that are exposed to radiation and burn-in damage to that region overtime. Additionally, this study also highlights the effect of the duty cycle on the dark current change in the panel.

42 ENGINEERING↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Measuring the X-ray luminosities of DESI groups from eROSITA Final Equatorial-Depth Survey – I. X-ray luminosity–halo mass scaling relation

ABSTRACT We use the eROSITA Final Equatorial-Depth Survey (eFEDS) to measure the rest-frame 0.1–2.4 keV band X-ray luminosities of ∼600 000 DESI groups using two different algorithms in the overlap region of the two observations. These groups span a large redshift range of 0.0 ≤ zg ≤ 1.0 and group mass range of $10^{10.76}\, h^{-1}\, \mathrm{M}_{\odot } \le M_h \le 10^{15.0}\, h^{-1}\, \mathrm{M}_{\odot }$. (1) Using the blind detection pipeline of eFEDS, we find that 10932 X-ray emission peaks can be cross-matched with our groups, ∼38 per cent of which have a signal-to-noise ratio $\rm {S}/\rm {N} \ge 3$ in X-ray detection. Comparing to the numbers reported in previous studies, this matched sample size is a factor of ∼6 larger. (2) By stacking X-ray maps around groups with similar masses and redshifts, we measure the average X-ray luminosity of groups as a function of halo mass in five redshift bins. We find that in a wide halo mass range, the X-ray luminosity, LX, is roughly linearly proportional to Mh and quite independent to the redshift of the groups. (3) We use a Poisson distribution to model the X-ray luminosities obtained using two different algorithms and obtain the best-fit $L_{\rm X}=10^{28.46\pm 0.03}M_{\rm h}^{1.024\pm 0.002}$ and $L_{\rm X}=10^{26.73 \pm 0.04}M_{\rm h}^{1.140 \pm 0.003}$ scaling relations, respectively. The best-fit slopes are flatter than the results previously obtained but closer to a self-similar prediction.

Astronomy & Astrophysics↗

X-ray diffraction from shock driven Sn microjets

Here, in situ x-ray diffraction was performed on shock-generated microjets composed of Sn and Sn–4Ag. Under low pressure drives (~21 GPa), a significant fraction of the jet volume was found to be in the β-Sn phase, and these crystallites were much smaller than the initial grain size of the material. Significant quantities of amorphous (molten) material were observed for higher drive pressures (~25–35 GPa). The extent of melting at these pressures was greater than would be predicted for uniaxial shock loading. Diffraction patterns from the Sn–4Ag alloy showed a peak that is consistent with the expected Ag 3 Sn intermetallic phase. This peak remained evident under drive conditions where the sample was otherwise fully amorphous. This indicates a slushy or a mixed phase of liquid Sn and solid Ag 3 Sn. Given the eutectic character of this alloy, this observation is attributed to a kinetic limitation on the dissolution of Ag 3 Sn. This implies that a much broader range of drive conditions will lead to mixed phase jets and ejecta than would be predicted from the equilibrium melt boundary of such alloys.

36 MATERIALS SCIENCE↗

Limits on X-Ray Polarization at the Core of Centaurus A as Observed with the Imaging X-Ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the 2–8 keV band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100 ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at 99% confidence (MDP 99 ) of 6.5% using a weighted, spectral model-independent calculation in the 2–8 keV band. The polarization angle ψ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy (0.3–400 keV) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption (N H ~ 10 23 cm -2 ) and a Fe Kα emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below 2 keV. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for the production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe Kα emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Sulfur Kβ X-ray emission spectroscopy: comparison with sulfur K-edge X-ray absorption spectroscopy for speciation of organosulfur compounds

Until recently, sulfur was known as a “spectroscopically silent” element because of a paucity of convenient spectroscopic probes suitable for in situ chemical speciation. In recent years the technique of sulfur K-edge X-ray absorption spectroscopy (XAS) has been used extensively in sulfur speciation in a variety of different fields. With an initial focus on reduced forms of organic sulfur, we have explored a complementary X-ray based spectroscopy – sulfur Kβ X-ray emission spectroscopy (XES) – as a potential analytical tool for sulfur speciation in complex samples. In this work, we compare and contrast the sensitivity of sulfur Kβ XES with that of sulfur K-edge XAS, and find differing sensitivities for the two techniques. In some cases an approach involving both sulfur K-edge XAS and sulfur Kβ XES may be a powerful combination for deducing sulfur speciation in samples containing complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab Initio Methods for L-edge X-ray Absorption Spectroscopy

The theoretical prediction of X-ray absorption spectra (XAS) has become common- place in electronic structure theory. The ability to better model and understand L-edge spectra is of great interest in the study of transition metal complexes and a wide variety of solid state materials. However, until recently few rst-principles works have mod- eled L-edge XAS due to the presence of strong spin-orbit coupling in the 2p orbitals which splits the observed peaks into multiple groups of features. Therefore, a proper description of spin-orbit coupling is vital for the successful prediction of L-edge spectra. A number of new approaches that incorporate spin-orbit coupling have recently made advances in the computation of L-edge spectra. In this review, we describe recent work in computational L-edge XAS and how these methods may continue to improve in the future. Comparison of the advantages and disadvantages of the various approaches are considered, with special attention to not only the computational cost of the level of theory, but also the various approaches that can be used to compute the absorption spectra with a large number of high energy excited states.

Kasper, Joseph M.↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Mitigating X-ray-induced damage for accurate analysis of battery cathodes using transmission X-ray microscopy

Here, we investigate the impact of X-ray-induced damage on the evolution of battery cathodes using synchrotron transmission X-ray microscopy. In an operando coin cell, exposure to the X-ray beam can induce bubble formation, potentially rendering cathode particles electrochemically inactive and displacing particles from their initial position. However, utilizing external pressure on a pouch cell can mitigate bubble formation and its associated effects.

25 ENERGY STORAGE↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗