Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-Ray Photoelectron Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Sodium hydroxide anodization of Ti-Al-4V adherends

The use of sodium hydroxide anodization (SHA) for Ti-6Al-4V adherends is examined. The SHA surface is evaluated using SEM, X-ray photoelectron spectroscopy, and Auger electron spectroscopy. The SHA procedures of Kennedy et al. (1983) were employed in this experiment. The photomicrographs of the SHA (sandblasted) and PSHA (sandblasted and pickled) oxide surface reveal that the two surfaces differ. The PSHA is patchy and similar to a chromic acid anodization surface and the porosity of the PSHA is more uniform than the SHA surface. The compositions of the surfaces are studied. It is noted that SHA is an effective pretreatment for Ti-6Al-4V adherends.

Filbey, Jennifer A.↗

Use of hydrophilic polymer coatings for control of electroosmosis and protein adsorption

The purpose of this project was to examine the utility of polyethylene glycol (PEG) and dextran coatings for control of electroosmosis and protein adsorption; electroosmosis is an important, deleterious process affecting electrophoretic separations, and protein adsorption is a factor which needs to be controlled during protein crystal growth to avoid multiple nucleation sites. Performance of the project required use of X-ray photoelectron spectroscopy to refine previously developed synthetic methods. The results of this spectroscopic examination are reported. Measurements of electroosmotic mobility of charged particles in appropriately coated capillaries reveals that a new, one-step route to coating capillaries gives a surface in which electroosmosis is dramatically reduced. Similarly, both PEG and dextran coatings were shown by protein adsorption measurements to be highly effective at reducing protein adsorption on solid surfaces. These results should have impact on future low-g electrophoretic and protein crystal growth experiments.

Harris, J. Milton↗

Boron nitride - Composition, optical properties, and mechanical behavior

A low energy ion beam deposition technique was used to grow boron nitride films on quartz, germanium, silicon, gallium arsenide, and indium phosphate. The film structure was amorphous with evidence of a hexagonal phase. The peak boron concentration was 82 at. percent. The carbon and oxygen impurities were in the 5 to 8 at. percent range. Boron-nitrogen and boron-boron bonds were revealed by X-ray photoelectron spectroscopy. The index of refraction varied from 1.65 to 1.67 for films deposited on III-V compound semiconductors. The coefficient of friction for boron nitride in sliding contact with diamond was less than 0.1. The substrate was silicon.

Pouch, John J.↗

Characterization of microcomposite polyimide films

Thermally stable microcomposite polyimide films were prepared by the homogeneous incorporation of either a soluble metal salt or a metal complex into a poly(amide-acid)/N,N-dimethylacetamide solution. The thermal processing of films solvent cast onto glass substrates and cured in an appropriate atmosphere yields films containing not only a fairly uniform dispersion of submicrometer particles, but also a new surface layer of metal or metal oxide. These polymeric systems have been characterized using X-ray photoelectron spectroscopy, Auger electron spectroscopy with depth profiling via argon ion etching, transmission electron microscopy of ultramicrotomed cross-sections, scanning electron microscopy, elemental analysis, thermal analysis, and variable temperature electrical resistivity determinations. The data from these techniques were used cooperatively to develop a model for these microcomposite polyimide films.

Rancourt, J. D.↗

Making Excited Oxygen Molecules And Atoms

Oxidation of semiconductors and high-temperature superconductors achieved at lower temperatures by use of oxygen molecules or atoms raised into specific excited states. Use of excited oxygen (or other species) of interest in research on kinetics and mechanisms of chemical reactions. Used in ultra-high-vacuum chamber also equipped for such surface-analytical techniques as x-ray photoelectron spectroscopy.

Vasquez, Richard P.↗

Design, development and applications of novel techniques for studying surface mechanical properties

Research is reviewed for the adhesion, friction, and micromechanical properties of materials and examples of the results presented. The ceramic and metallic materials studied include silicon carbide, aluminum oxide, and iron-base amorphous alloys. The design and operation of a torsion balance adapted for study of adhesion from the Cavendish balance are discussed first. The pull-off force (adhesion) and shear force (friction) required to break the interfacial junctions between contacting surfaces of the materials were examined at various temperatures in a vacuum. The surface chemistry of the materials was analyzed by X-ray photoelectron spectroscopy. Properties and environmental conditions of the surface regions which affect adhesion and friction-such as surface segregation, composition, crystal structure, surface chemistry, and temperature were also studied.

Miyoshi, Kazuhisa↗

Auger and ESCA analysis

X-ray photoelectron spectroscopy (XPS or ESCA) and Auger electron spectroscopy (AES) techniques are discussed. The XPS instrument is a Perkin-Elmer 5400 system which provides both elemental and chemical state information without restriction on the type of material that can be analyzed. The AES instrument is a Kratos Analytical XSAM 800 system. AES uses a beam of high energy electrons as a surface probe. Following electronic rearrangements within excited atoms by this probe, Auger electrons characteristic of each element present are emitted from the sample. Specific examples of analytic techniques and results are presented.

Gregory, John C.↗

Structural chemistry of Au(III)-substituted Ba2YCu3O(7-delta)

A series of gold-substituted perovskite superconductors Ba2Y(Cu/1-x/Aux)3O(7-delta)(x = 0-0.1) was synthesized. For x = 0.1, there was no change in the a and b lattice parameters (a = 3.826 A and b = 3.889 A), but a 0.06 A c-axis expansion to 11.75 A was observed. Substituted gold was found to be trivalent by X-ray photoelectron spectroscopy. Replacing Cu(1) in the copper oxide chain with a slight reordering of oxygen is consistent with c-axis expansion. The formal charge of the site remains trivalent, while remaining Cu in the chains is reduced to Cu(I), resulting in an oxygen stoichiometry of less than 7. Finally, no large effect on Tc is observed (Tc = 89 K for x = 0.10), in contrast to the effect of a number of other metal ion dopants. These results are discussed relative to the chemistry of Au(III) and to the use of the metal in structures containing gold and ceramic superconductors.

Hepp, A. F.↗

The effect of metal surface passivation on the Au-InP interaction

The effect of SiO2 encapsulation on reaction rates in the Au-InP system was studied. Scanning electron microscopy and x-ray photoelectron spectroscopy were used to investigate surface and/or interface morphologies and in-depth compositional profiles. It was found that the rate of dissolution of InP into Au and subsequent phase transformations are largely dependent on the condition of the free surface of the metalization. SiO2 capping of Au is reported for the first time to suppress the Au-InP reaction rate. The Au-InP interaction is shown to be quite similar to the Au-GaAs interaction despite differences in behavior of the group-V elements.

Fatemi, Navid S.↗

Development of sputter coatings for the gravity probe B gyroscope housings

Cu/Ti coatings have been applied by sputter deposition to fused quartz housings to serve as the electrodes and lands of electrostatically supported gyroscopes. Niobium-coated fused quartz gyro rotors have been successfully suspended and spun up in those housings. The Cu/Ti bilayer coating and alternative multilayer coatings (Cu/Mo, Mo/Cu/Ti and Mo/Cu/Mo) with 2-micron thickness produced by sputter deposition on flat, fused quartz substrates have been examined with scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and four-point resistivity measurement techniques. The multilayer coatings with a molybdenum bonding layer appear to produce smoother surfaces than those with a titanium bonding layer. All multilayer coatings survived thermal cycling to 77 K without adhesion failure.

Zhou, P.↗

Hydrogen-terminated silicon substrates for low-temperature molecular beam epitaxy

The preparation of hydrogen-terminated silicon surfaces for use as starting substrates for low-temperature MBE growth is examined in detail. The procedure involves the ex situ removal under nitrogen of residual oxide from a silicon substrate using a spin-clean with HF in ethanol, followed by the in situ low-temperature desorption (150 C) of physisorbed etch residues. The critical steps and the chemical basis for these steps are examined using X-ray photoelectron spectroscopy. Impurity residues at the epilayer-substrate interface following subsequent homoepitaxial growth are studied using AES, SIMS and TEM. Finally, scanning tunneling microscopy is used to examine the effect of cleaning methods on substrate morphology.

Grunthaner, P. J.↗

XPS, AES and friction studies of single-crystal silicon carbide

The surface chemistry and friction behavior of a single crystal silicon carbide surface parallel to the 0001 plane in sliding contact with iron at various temperatures to 1500 C in a vacuum of 3 x 10 nPa are investigated using X-ray photoelectron and Auger electron spectroscopy. Results show that graphite and carbide-type carbon are seen primarily on the silicon carbide surface in addition to silicon at temperatures to 800 C by both types of spectroscopy. The coefficients of friction for iron sliding against a silicon carbide surface parallel to the 0001 plane surface are found to be high at temperatures up to 800 C, with the silicon and carbide-type carbon at maximum intensity in the X-ray photoelectron spectroscopy at 800 C. The concentration of the graphite increases rapidly on the surface as the temperature is increased above 800 C, while the concentrations of the carbide-type carbon and silicon decrease rapidly and this presence of graphite is accompanied by a significant decrease in friction. Preheating the surfaces to 1500 C also gives dramatically lower coefficients of friction when reheating in the sliding temperature range of from room temperature to 1200 C, with this reduction in friction due to the graphite layer on the silicon carbide surface.

Miyoshi, K.↗

A high flux source of swift oxygen atoms

A source of swift oxygen atoms is described which has several unique features. A high current ion beam is produced by a microwave discharge, accelerated to 10 keV and the mass selected by a modified Du Pont 21-110 mass spectrometer. The O(+) beam exciting the mass spectrometer is focused into a rectangular shape with an energy spread of less than 1 eV. The next section of the machine decelerates the ion beam into a counterpropagating electron beam in order to minimize space charge effects. After deceleration, the ion beam intersects at 90 deg, a neutral oxygen atom beam, which via resonant charge exchange produces a mixture of O(+) and O. Any remaining O(+) are swept out of the beam by an electric field and differentially pumped away while the desired O beam, collimated by slits, impinges on the target. In situ monitoring of the target surface is done by X-ray photoelectron or Auger spectroscopy. Faraday cups provide flux measurements in the ion sections while the neutral flux is determined by a special torsion balance or by a quadrupole mass spectrometer specially adapted for swift atoms. While the vacuum from the source through the mass spectrometer is maintained by diffusion pumps, the rest of the machine is UHV.

Fink, M.↗

Surface chemistry and friction behavior of the silicon carbide (0001) surface at temperatures to 1500 deg C

X-ray photoelectron and Auger electron spectroscopy analyses and friction studies were conducted with a silicon carbide (0001) surface in contact with iron at various temperatures to 1200 or 1500 C in a vacuum of 10 to the minus 8th power Pa. The results indicate that there is a significant temperature influence on both the surface chemistry and friction properties of silicon carbide. The principal contaminant of adsorbed amorphous carbon on the silicon carbide surface in the as received state is removed by simply heating to 400 C. Above 400 C, graphite and carbide type carbine are the primary species on the silicon carbide surface, in addition to silicon. The coefficients of friction of polycrystalline iron sliding against a single crystal silicon carbide (0001) surface were high at temperatures to 800 C. Similar coefficients of friction were obtained at room temperature after the silicon carbide was preheated at various temperatures up 800 C. When the friction experiments were conducted above 800 C or when the specimens were preheated to above 800 C, the coefficients of friction were dramatically lower. At 800 C the silicon and carbide type carbon are at a maximum intensity in the XPS spectra. With increasing temperature above 800 C, the concentration of the graphite increases rapidly on the surface, whereas those of the carbide type carbon and silicon decrease rapidly.

Miyoshi, K.↗

Surface chemistry and wear behavior of single-crystal silicon carbide sliding against iron at temperatures to 1500 C in vacuum

X-ray photoelectron and Auger electron spectroscopy analyses and morphological studies of wear and metal transfer were conducted with a single-crystal silicon carbide 0001 surface in contact with iron at various temperatures to 1500 C in a vacuum of 10 to the minus 8th power pascal. The results indicate that below 800 C, carbide-carbon and silicon are primarily seen on the silicon carbide surface. Above 800 C the graphite increases rapidly with increase in temperature. The outermost surficial layer, which consists mostly of graphite and little silicon at temperatures above 1200 C is about 2 nm thick. A thicker layer, which consists of a mixture of graphite, carbide, and silicon is approximately 100 nm thick. The closer the surface sliding temperature is to 800 C, the more the metal transfer produced. Above 800 C, there was a transfer of rough, discontinuous, and thin iron debris instead of smooth, continuous and thin iron film which was observed to transfer below 800 C. Two kinds of fracture pits were observed on the silicon carbide surface: (1) a pit with a spherical asperity; and (2) multiangular shaped pits.

Miyoshi, K.↗

Surface chemistry, friction and wear of Ni-Zn and Mn-Zn ferrites in contact with metals

X-ray photoelectron and Auger electron spectroscopy analysis were used in sliding friction experiments. These experiments were conducted with hot-pressed polycrystalline Ni-Zn and Mn-Zn ferrites, and single-crystal Mn-Zn ferrite in contact with various transition metals at room temperature in both vacuum and argon. The results indicate that Ni2O3 and Fe3O4 were present on the Ni-Zn ferrite surface in addition to the nominal bulk constituents, while MnO2 and Fe3O4 were present on the Mn-Zn ferrite surface in addition to the nominal bulk constituents. The coefficients of friction for the ferrites in contact with metals were related to the relative chemical activity of these metals. The more active the metal, the higher is the coefficient of friction. The coefficients of friction for the ferrites were correlated with the free energy of formation of the lowest metal oxide. The interfacial bond can be regarded as a chemical bond between the metal atoms and the oxygen anions in the ferrite surfaces. The adsorption of oxygen on clean metal and ferrite does strengthen the metal-ferrite contact and increase the friction. The ferrites exhibit local cracking and fracture with sliding under adhesive conditions. All the metals transferred to he surfaces of the ferrites in sliding.

Miyoshi, K.↗

Surface chemistry, friction, and wear of Ni-Zn and Mn-Zn ferrites in contact with metals

X-ray photoelectron and Auger electron spectroscopy analysis were used in sliding friction experiments. These experiments were conducted with hot-pressed polycrystalline Ni-Zn and Mn-Zn ferrites, and single-crystal Mn-Zn ferrite in contact with various transition metals at room temperature in both vacuum and argon. The results indicate that Ni2O3 and Fe3O4 were present on the Ni-Zn ferrite surface in addition to the nominal bulk constituents, while MnO2 and Fe3O4 were present on the Mn-Zn ferrite surface in addition to the nominal bulk constituents. The coefficients of friction for the ferrites in contact with metals were related to the relative chemical activity of these metals. The more active the metal, the higher is the coefficient of friction. The coefficients of friction for the ferrites were correlated with the free energy of formation of the lowest metal oxide. The interfacial bond can be regarded as a chemical bond between the metal atoms and the oxygen anions in the ferrite surfaces. The adsorption of oxygen on clean metal and ferrite does strengthen the metal-ferrite contact and increase the friction. The ferrites exhibit local cracking and fracture with sliding under adhesive conditions. All the metals transferred to the surfaces of the ferrites in sliding. Previously announced in STAR as N83-19901

Miyoshi, K.↗