Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation for structuring Li-ion electrodes for fast charging and its impact on material properties, rate capability, Li plating, and wetting

Laser ablation is a scalable technique for decreasing the effective tortuosity of electrodes by selectively removing material with high precision. Applied to ≈ 110 um thick electrode coatings, this work focuses on understanding the impact of laser ablation on electrode material properties at the beginning of life and synergistic impacts of ablated channels on cell performance throughout their cycle life. Post laser ablation, local changes in chemistry, crystallography, and morphology of the laser-impacted electrode regions are investigated. It is shown that femtosecond pulsed laser ablation can achieve high-rate material removal with minor material damage locally at the interface of the impacted zones. The capacity achieved during a 6C (10 min) constant-current constant-voltage charge to 4.2 V improved from 1 mAh cm -2 for the non-ablated electrodes to almost 2 mAh cm -2 for the ablated electrodes. This benefit is attributed to a synergistic effect of enhanced wetting and decreased electrode tortuosity. The benefit was maintained for over 120 cycles, and upon disassembly decreased Li-plating on the graphite anode was observed. Finally, multi-physics modeling in conjunction with wetting analyses showed that laser ablating either one of the electrodes led to substantial improvements in wetting and rate capability, indicating that substantial performance benefits can be achieved by ablating only the graphite anode as apposed to both electrodes.

25 ENERGY STORAGE↗

The role of incidence angle in the laser ablation of a planar target

The effect of the laser ray incidence angle on the mass ablation rate and ablation pressure of planar inertial confinement fusion (ICF) targets is explored. In this work, a modified version of the textbook model of laser ablation is used to demonstrate that the mass ablation rate and ablation pressure scale with the 4/3 and 2/3 power of the cosine of the laser ray incidence angle relative to the target normal. Using an idealized planar model of ablation, it is demonstrated that constant irradiance is insufficient to produce similar velocities of a target when comparing cases driven at different incidence angles. Additionally, the effect of the incidence angle on the absorption fraction is demonstrated and it is shown that a longer duration is needed to achieve maximum absorption for greater angles. This further affects the mass ablation rate and ablation pressure in the first nanosecond of ablation. Here these results, when extrapolated, may provide insight into the variation of drive conditions encountered due to incidence in polar direct drive ICF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of the Three NIF Ablators

Indirect drive implosion experiments on NIF have now been performed using three different ablator materials: glow discharge polymer (GDP) or CH, high density carbon (HDC, which we also refer to as diamond), and sputtered beryllium (Be). It has been appreciated for some time that each of these materials has specific advantages and disadvantages as an ICF ablator.[1-4] In light of experiments conducted on NIF in the last few years, how do these ablators compare? Given current understanding, is any ablator more or less likely to reach ignition on NIF? Has the understanding of their respective strengths and weaknesses changed since NIF experiments began? How are those strengths and weaknesses highlighted by implosion designs currently being tested or planned for testing soon? This document aims to address these questions by combining modern simulation results with a survey of the current experimental data base. More particularly, this document is meant to fulfill an L2 Milestone for FY17 to “Document our understanding of the relative advantages and disadvantages of CH, HDC, and Be designs.” Note that this document does not aim to recommend a down-selection of the current three ablator choices. It is intended only to gather and document the current understanding of the differences between these ablators and thereby inform the choices made in planning future implosion experiments. This document has two themes: (i) We report on a reanalysis project in which post-shot simulations were done on a common basis for layered shots using each ablator. This included data from keyholes, 2D ConA, and so forth, from each campaign, leading up to the layered shots. (“Keyholes” are shots dedicated to measuring the shock timing in a NIF target, as described in Ref. 5. “2DConAs” are backlit implosions in which the symmetry of the implosion is measured between about half and full convergence, as described in Ref. 6.) This set of common-basis postshot simulations is compared to the respective shots. Each was then scaled to a “full NIF” experiment that could be done using the respective ablators at full NIF power and/or energy, and these scaled-up designs were simulated in detail. (ii) The report also contains a general survey of experimental and simulated results as pertinent to comparing and evaluating the three ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Direct Current-Enhanced Radiofrequency Ablation: An Ex Vivo Study

The purpose of this study was to investigate the optimal setting for radiofrequency (RF) ablation combined with direct electrical current (DC) ablation in ex vivo bovine liver. An electrical circuit combining a commercially available RF ablation system with DC was developed. The negative electrode of a rectifier that provides DC was connected to a 3-cm multitined expandable RF probe. A 100-mH inductor was used to prevent electrical leakage from the RF generator. DC was applied for 15 min and followed by RF ablation in freshly excised bovine livers. Electric current was measured by an ammeter. Coagulation volume, ablation duration, and mean amperage were assessed for various DC voltages (no DC, 2.2, 4.5, and 9.0 V) and different RF ablation protocols (stepwise increase from 40 to 80 W, 40 W fixed, and 80 W fixed). Results were compared using Kruskal-Wallis and Mann-Whitney U test. Applying DC with 4.5 or 9.0 V, in combination with 40 W fixed or a stepwise increase of RF energy, resulted in significantly increased zone of ablation size compared with 2.2 V or no DC (P = 0.009). At 4.5 V DC, the stepwise increase of RF energy resulted in the same necrosis size as a 40 W fixed protocol (26.6 {+-} 3.9 vs. 26.5 {+-} 4.0 ml), but ablation duration was significantly decreased (296 {+-} 85 s vs. 423 {+-} 104 s; P = 0.028). Mean amperage was significantly lower at 4.5 V compared with 9.0 V (P = 0.028). Combining a stepwise increase of RF energy with a DC voltage of 4.5 V is most appropriate to increase coagulation volume and to minimize procedure time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Evaluation of Lung Microwave Ablation in a Porcine Tumor Mimic Model

To evaluate the microwave ablation of created tumor mimics in the lung of a large animal model (pigs), with examination of the ablative synergy of multiple antennas. Fifty-six tumor-mimic models of various sizes were created in 15 pigs by using barium-enriched minced collected thigh muscle injected into the lung of the same animal. Tumors were ablated under fluoroscopic guidance by single-antenna and multiple-antenna microwaves. Thirty-five tumor models were treated in 11 pigs with a single antenna at 75 W for 15 min, with 15 measuring 20 mm in diameter, 10 measuring 30 mm, and 10 measuring 40 mm. Mean circularity of the single-antenna ablation zones measured 0.64 {+-} 0.12, with a diameter of 35.7 {+-} 8.7 mm along the axis of the antenna and 32.7 {+-} 12.8 mm perpendicular to the feeding point. Multiple-antenna delivery of 75 W for 15 min caused intraprocedural death of 2 animals; modified protocol to 60 W for 10 min resulted in an ablation zone with a diameter of 43.0 {+-} 7.7 along the axis of the antenna and 54.8 {+-} 8.5 mm perpendicular to the feeding point; circularity was 0.70 {+-} 0.10. A single microwave antenna can create ablation zones large enough to cover lung tumor mimic models of {<=}4 cm with no heat sink effect from vessels of {<=}6 mm. Synergic use of 3 antennas allows ablation of larger volumes than single-antenna or radiofrequency ablation, but great caution must be taken when 3 antennas are used simultaneously in the lung in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 Cases

PurposeThis study was designed to assess feasibility of US-CT/MRI fusion-guided ablation in liver tumors undetectable with US.MethodsFrom 2002 to 2012, 295 tumors (162 HCCs and 133 metastases; mean diameter 1.3 ± 0.6 cm, range 0.5–2.5 cm) detectable on contrast-enhanced CT/MRI, but completely undetectable with unenhanced US and either totally undetectable or incompletely conspicuous with contrast-enhanced US (CEUS), were treated in 215 sessions using either internally cooled radiofrequency or microwave with standard ablation protocols, guided by an image fusion system (Virtual Navigation System, Esaote S.p.A., Genova, Italy) that combines US with CT/ MRI images. Correct targeting and successful ablation of tumor were verified after 24 hours with CT or MRI.ResultsA total of 282 of 295 (95.6 %) tumors were correctly targeted with successful ablation achieved in 266 of 295 (90.2 %). Sixteen of 295 (5.4 %) tumors were correctly targeted, but unsuccessfully ablated, and 13 of 295 (4.4 %) tumors were unsuccessfully ablated due to inaccurate targeting. There were no perioperative deaths. Major complications were observed in 2 of the 215 treatments sessions (0.9 %).ConclusionsReal-time virtual navigation system with US-CT/MRI fusion imaging is precise for targeting and achieving successful ablation of target tumors undetectable with US alone. Therefore, a larger population could benefit from ultrasound guided ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Irreversible Electroporation in the Porcine Kidney: Are Numerical Simulations Reliable for Predicting Empiric Ablation Outcomes?

PurposeNumerical simulations are used for treatment planning in clinical applications of irreversible electroporation (IRE) to determine ablation size and shape. To assess the reliability of simulations for treatment planning, we compared simulation results with empiric outcomes of renal IRE using computed tomography (CT) and histology in an animal model.MethodsThe ablation size and shape for six different IRE parameter sets (70–90 pulses, 2,000–2,700 V, 70–100 µs) for monopolar and bipolar electrodes was simulated using a numerical model. Employing these treatment parameters, 35 CT-guided IRE ablations were created in both kidneys of six pigs and followed up with CT immediately and after 24 h. Histopathology was analyzed from postablation day 1.ResultsAblation zones on CT measured 81 ± 18 % (day 0, p ≤ 0.05) and 115 ± 18 % (day 1, p ≤ 0.09) of the simulated size for monopolar electrodes, and 190 ± 33 % (day 0, p ≤ 0.001) and 234 ± 12 % (day 1, p ≤ 0.0001) for bipolar electrodes. Histopathology indicated smaller ablation zones than simulated (71 ± 41 %, p ≤ 0.047) and measured on CT (47 ± 16 %, p ≤ 0.005) with complete ablation of kidney parenchyma within the central zone and incomplete ablation in the periphery.ConclusionBoth numerical simulations for planning renal IRE and CT measurements may overestimate the size of ablation compared to histology, and ablation effects may be incomplete in the periphery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

“Edgeboost”: A Novel Technique to Extend the Ablation Zone Lateral to a Two-Probe Bipolar Radiofrequency Device

BackgroundThe dual-electrode bipolar-RFA (B-RFA) is increasingly used to ablate large liver tumours (3–7 cm). However, the challenging aspect of B-RFA is the placement of the two electrodes around the tumour. Realignment often requires the electrodes to be extracted and reinserted.AimThe aim of this study is to examine “Edgeboost”, a novel technique to increase the lateral ablation dimension without requiring any realignment of the electrodes.Methods and MaterialsAn egg-white model and an ex vivo calf liver model were used compare the standard bipolar mode ablation to Edgeboost-1 (reaching full impedance in bipolar mode initially, then cycling in unipolar mode between left and right probes) and Edgeboost-2 (similar to Edgeboost-1 but not reaching full impedance initially in bipolar mode in order to minimize charring and, thus, to increase total ablation time).ResultsA significantly larger outer lateral ablation dimension to the probe was achieved with Edgeboost-1 compared to the standard method in the liver model (1.14 cm, SD: 0.16 vs. 0.44 cm, SD: 0.24, p = 0.04). Edgeboost-2 achieved the largest outer lateral ablation dimension of 1.75 cm (SD: 0.35). A similar association was seen in the egg model. Edgeboost-2 almost doubled the mass ablated with standard bipolar alone (mass ratio: 1:1.94 in egg white and 1:1.84 in liver).ConclusionThis study demonstrates that the novel “Edgeboost” technique can increase the outer lateral ablation dimension without requiring the two inserted electrodes to be reinserted. This would be beneficial for interventionists who use the dual B-RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Osteoid Osteomas Using a Navigational Bipolar Radiofrequency Ablation System

BackgroundPercutaneous CT-guided radiofrequency ablation is a safe and effective minimally invasive treatment for osteoid osteomas. This technical case series describes the use of a recently introduced ablation system with a probe that can be curved in multiple directions, embedded thermocouples for real-time monitoring of the ablation volume, and a bipolar design that obviates the need for a grounding pad.MethodsMedical records of all patients who underwent radiofrequency ablation of an osteoid osteoma with the STAR Tumor Ablation System (DFINE; San Jose, CA) were reviewed. The location of each osteoid osteoma, nidus volume, and procedural details were recorded. Treatment efficacy and long-term complications were assessed at clinical follow-up.ResultsDuring the study period, 18 osteoid osteomas were radiofrequency ablated with the multidirectional bipolar system. Lesion locations included the femur (50 %; 9/18), tibia (22 %; 4/18), cervical spine (11 %; 2/18), calcaneus (5.5 %; 1/18), iliac bone (5.5 %; 1/18), and fibula (5.5 %; 1/18). The median nidus volume of these cases was 0.33 mL (range 0.12–2.0 mL). All tumors were accessed via a single osseous channel. Median cumulative ablation time was 5 min and 0 s (range 1 min and 32 s–8 min and 50 s). All patients with clinical follow-up reported complete symptom resolution. No complications occurred.ConclusionSafe and effective CT-guided radiofrequency ablation of osteoid osteomas can be performed in a variety of locations using a multidirectional bipolar system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency and Microwave Ablation Compared to Systemic Chemotherapy and to Partial Hepatectomy in the Treatment of Colorectal Liver Metastases: A Systematic Review and Meta-Analysis

PurposeTo assess safety and outcome of radiofrequency ablation (RFA) and microwave ablation (MWA) as compared to systemic chemotherapy and partial hepatectomy (PH) in the treatment of colorectal liver metastases (CRLM).MethodsMEDLINE, Embase and the Cochrane Library were searched. Randomized trials and comparative observational studies with multivariate analysis and/or matching were included. Guidelines from National Guideline Clearinghouse and Guidelines International Network were assessed using the AGREE II instrument.ResultsThe search revealed 3530 records; 328 were selected for full-text review; 48 were included: 8 systematic reviews, 2 randomized studies, 26 comparative observational studies, 2 guideline-articles and 10 case series; in addition 13 guidelines were evaluated. Literature to assess the effectiveness of ablation was limited. RFA + systemic chemotherapy was superior to chemotherapy alone. PH was superior to RFA alone but not to RFA + PH or to MWA. Compared to PH, RFA showed fewer complications, MWA did not. Outcomes were subject to residual confounding since ablation was only employed for unresectable disease.ConclusionThe results from the EORTC-CLOCC trial, the comparable survival for ablation + PH versus PH alone, the potential to induce long-term disease control and the low complication rate argue in favour of ablation over chemotherapy alone. Further randomized comparisons of ablation to current-day chemotherapy alone should therefore be considered unethical. Hence, the highest achievable level of evidence for unresectable CRLM seems reached. The apparent selection bias from previous studies and the superior safety profile mandate the setup of randomized controlled trials comparing ablation to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of initial γ -irradiation on infrared laser ablation of poly(vinyl alcohol) studied by infrared spectroscopy

We report the effect of initial γ-irradiation of poly(vinyl alcohol) (PVA) on the kinetics of polymer ablation under CO 2 laser irradiation was studied using infra-red spectroscopy. The rate of laser ablation rapidly decreases with increasing time of laser ablation up to 10 s. Initial γ-irradiation of a dose up to 100 kGy reduces the rate of the laser ablation, just like the effect of laser exposure. The number of OH and CH groups decrease in PVA both with laser irradiation and with γ-irradiation. The number of OH groups decreases more under laser irradiation. Unsaturated bonds are formed in γ–irradiated PVA on the surface of the crater formed by laser ablation of the polymer that has undergone radiolysis. Increasing the dose of initial γ-irradiation from 100 to 2300 kGy leads to an increase in the intensity of the IR bands of the unsaturated bonds. The number of IR bands in the spectra of the laser ablation crater of PVA does not change with the dose of initial γ-irradiation. A dose of radiolysis of 3500 kGy significantly changes the IR spectra of both the ablation crater and the coating formed from the ablation products. Many bands characteristic for PVA are no longer present and the intensities of bands corresponding to unsaturated bonds are increased. A computational model for loss of water and ketone formation was developed for PVA and PVA including a diol using G3(MP2). The highest activation energy barrier step in the decomposition reaction was formation of the enol species and water was shown to catalyze all decomposition steps.

36 MATERIALS SCIENCE↗

Principles of the radiative ablation modeling

Indirectly driven inertial confinement fusion (ICF) rests on the setting up of a radiation temperature within a laser cavity and on the optimization of the capsule implosion ablated by this radiation. In both circumstances, the ablation of an optically thick medium is at work. The nonlinear radiation conduction equations that describe this phenomenon admit different kinds of solutions called generically Marshak waves. In this paper, a completely analytic model is proposed to describe the ablation in the subsonic regime relevant to ICF experiments. This model approximates the flow by a deflagrationlike structure where Hugoniot relations are used in the stationary part from the ablation front up to the isothermal sonic Chapman-Jouguet point and where the unstationary expansion from the sonic point up to the external boundary is assumed quasi-isothermal. It uses power law matter properties. It can also accommodate arbitrary boundary conditions provided the ablation wave stays very subsonic and the surface temperature does not vary too quickly. These requirements are often met in realistic situations. Interestingly, the ablated mass rate, the ablation pressure, and the absorbed radiative energy depend on the time history of the surface temperature, not only on the instantaneous temperature values. The results compare very well with self-similar solutions and with numerical simulations obtained by hydrodynamic code. This analytic model gives insight into the physical processes involved in the ablation and is helpful for optimization and sensitivity studies in many situations of interest: radiation temperature within a laser cavity, acceleration of finite size medium, and ICF capsule implosion, for instance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density gradient effects in weakly nonlinear ablative Rayleigh-Taylor instability

In this research, density gradient effects (i.e., finite thickness of ablation front effects) in ablative Rayleigh-Taylor instability (ARTI), in the presence of preheating within the weakly nonlinear regime, are investigated numerically. We analyze the weak, medium, and strong ablation surfaces which have different isodensity contours, respectively, to study the influences of finite thickness of ablation front on the weakly nonlinear behaviors of ARTI. Linear growth rates, generation coefficients of the second and the third harmonics, and coefficients of the third-order feedback to the fundamental mode are obtained. It is found that the linear growth rate which has a remarkable maximum, is reduced, especially when the perturbation wavelength {lambda} is short and a cut-off perturbation wavelength {lambda}{sub c} appears when the perturbation wavelength {lambda} is sufficiently short, where no higher harmonics exists when {lambda}<{lambda}{sub c}. The phenomenon of third-order positive feedback to the fundamental mode near the {lambda}{sub c}[J. Sanz et al., Phys. Rev. Lett. 89, 195002 (2002); J. Garnier et al., Phys. Rev. Lett. 90, 185003 (2003); J. Garnier and L. Masse, Phys. Plasmas 12, 062707 (2005)] is confirmed in numerical simulations, and the physical mechanism of the third-order positive feedback is qualitatively discussed. Moreover, it is found that generations and growths of the second and the third harmonics are stabilized (suppressed and reduced) by the ablation effect. Meanwhile, the third-order negative feedback to the fundamental mode is also reduced by the ablation effect, and hence, the linear saturation amplitude (typically {approx}0.2{lambda} in our simulations) is increased significantly and therefore exceeds the classical prediction 0.1{lambda}, especially for the strong ablation surface with a small perturbation wavelength. Overall, the ablation effect stabilizes the ARTI in the weakly nonlinear regime. Numerical results obtained are in general agreement with the recent weakly nonlinear theories and simulations as proposed [J. Sanz et al., Phys. Rev. Lett. 89, 195002 (2002); J. Garnier et al., Phys. Rev. Lett. 90, 185003 (2003); J. Garnier and L. Masse, Phys. Plasmas 12, 062707 (2005)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultraviolet versus infrared: Effects of ablation laser wavelength on the expansion of laser-induced plasma into one-atmosphere argon gas

Laser-induced plasma from an aluminum target in one-atmosphere argon background has been investigated with ablation using nanosecond ultraviolet (UV: 355 nm) or infrared (IR: 1064 nm) laser pulses. Time- and space-resolved emission spectroscopy was used as a diagnostics tool to have access to the plasma parameters during its propagation into the background, such as optical emission intensity, electron density, and temperature. The specific feature of nanosecond laser ablation is that the pulse duration is significantly longer than the initiation time of the plasma. Laser-supported absorption wave due to post-ablation absorption of the laser radiation by the vapor plume and the shocked background gas plays a dominant role in the propagation and subsequently the behavior of the plasma. We demonstrate that the difference in absorption rate between UV and IR radiations leads to different propagation behaviors of the plasma produced with these radiations. The consequence is that higher electron density and temperature are observed for UV ablation. While for IR ablation, the plasma is found with lower electron density and temperature in a larger and more homogenous axial profile. The difference is also that for UV ablation, the background gas is principally evacuated by the expansion of the vapor plume as predicted by the standard piston model. While for IR ablation, the background gas is effectively mixed to the ejected vapor at least hundreds of nanoseconds after the initiation of the plasma. Our observations suggest a description by laser-supported combustion wave for the propagation of the plasma produced by UV laser, while that by laser-supported detonation wave for the propagation of the plasma produced by IR laser. Finally, practical consequences of specific expansion behavior for UV or IR ablation are discussed in terms of analytical performance promised by corresponding plasmas for application with laser-induced breakdown spectroscopy.

36 MATERIALS SCIENCE↗

Rare event molecular dynamics simulations of plasma induced surface ablation

The interaction of thermal Ar plasma particles with Si and W surfaces is modeled using classical molecular dynamics (MD) simulations. At plasma energies above the threshold for ablation, the ablation yield can be calculated directly from MD. For plasma energies below threshold, the ablation yield becomes exponentially low, and direct MD simulations are inefficient. Instead, we propose an integration method where the yield is calculated as a function of the Ar incident kinetic energy. Subsequent integration with a Boltzmann distribution at the temperature of interest gives the thermal ablation yield. At low plasma temperatures, the ablation yield follows an Arrhenius form in which the activation energy is shown to be the threshold energy for ablation. Interestingly, equilibrium material properties, including the surface and bulk cohesive energy, are not good predictors of the threshold energy for ablation. The surface vacancy formation energy is better, but is still not a quantitative predictor. An analysis of the trajectories near threshold shows that ablation occurs by different mechanisms on different material surfaces, and both the mechanism and the binding of surface atoms determine the threshold energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved investigations of the non-thermal ablation process of graphite induced by femtosecond laser pulses

We report on the in-situ analysis of the ablation dynamics of the, so-called, laser induced non-thermal ablation process of graphite. A highly oriented pyrolytic graphite is excited by femtosecond laser pulses with fluences below the classic thermal ablation threshold. The ablation dynamics are investigated by axial pump-probe reflection measurements, transversal pump-probe shadowgraphy, and time-resolved transversal emission photography. The combination of the applied analysis methods allows for a continuous and detailed time-resolved observation of the non-thermal ablation dynamics from several picoseconds up to 180 ns. Formation of large, μm-sized particles takes place within the first 3.5 ns after irradiation. The following propagation of ablation products and the shock wave front are tracked by transversal shadowgraphy up to 16 ns. The comparison of ablation dynamics of different fluences by emission photography reveals thermal ablation products even for non-thermal fluences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗