Search NASA⌕ Search

SEARCH · Search NASA

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Absolute colors and phase coefficients of asteroids

Context: We use the phase curves of small bodies to measure absolute magnitudes and, together with complementary theoretical and laboratory results, to understand the micro- and macroscopic properties of their surfaces. Although we can observe asteroids up to phase angles of about 30 deg, the range of phase angles covered by outer Solar System objects usually does not go further than 7-10 deg for centaurs and 2 deg for trans-Neptunian objects, and a linear relation between magnitude and phase angle may be assumed. Aims: We aim to directly compare data taken for objects in the inner Solar System (inside the orbit of Jupiter) with data for centaurs and trans-Neptunian objects. Methods: We use the SLOAN Moving Objects Catalog (MOC) data to construct phase curves restricted to phase angles of less than or equal to 7.5 deg, which is compatible with the angles observed for the trans-Neptunian and Centaur population. We assume a linear model for the photometric behavior to obtain absolute magnitudes and phase coefficients in the ugirz, V, and R filters. Results: We obtain absolute magnitudes in seven filters for over 4000 objects. Our comparison with outer Solar System objects suggests the surfaces have a common property: intrinsically redder objects become blue with increasing phase angle, while the opposite happens for intrinsically bluer objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute continuity for operator valued completely positive maps on C*-algebras

Motivated by applicability to quantum operations, quantum information, and quantum probability, we investigate the notion of absolute continuity for operator valued completely positive maps on C*-algebras, previously introduced by Parthasarathy [in Athens Conference on Applied Probability and Time Series Analysis I (Springer-Verlag, Berlin, 1996), pp. 34-54]. We obtain an intrinsic definition of absolute continuity, we show that the Lebesgue decomposition defined by Parthasarathy is the maximal one among all other Lebesgue-type decompositions and that this maximal Lebesgue decomposition does not depend on the jointly dominating completely positive map, we obtain more flexible formulas for calculating the maximal Lebesgue decomposition, and we point out the nonuniqueness of the Lebesgue decomposition as well as a sufficient condition for uniqueness. In addition, we consider Radon-Nikodym derivatives for absolutely continuous completely positive maps that, in general, are unbounded positive self-adjoint operators affiliated to a certain von Neumann algebra, and we obtain a spectral approximation by bounded Radon-Nikodym derivatives. An application to the existence of the infimum of two completely positive maps is indicated, and formulas in terms of Choi's matrices for the Lebesgue decomposition of completely positive maps in matrix algebras are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute calibration of LIDAR Thomson scattering systems by rotational Raman scattering

Absolute calibration of LIDAR Thomson scattering systems on large fusion devices may be achieved using rotational Raman scattering. The choice of calibrating gas molecule presents different options and design trade-offs and is likely to be strongly dependent on the laser wavelength selected. Raman scattering of hydrogenic molecules produces a very broad spectrum, however, with far fewer scattered photons than scattering from nitrogen or oxygen at the same gas pressure. Lower laser wavelengths have the advantage that the Raman cross section increases, {sigma}{sub Raman}{proportional_to}1/{lambda}{sub 0}{sup 4}, but the disadvantage that the spectral width of the scattered spectrum decreases, {Delta}{lambda}{sub Raman}{proportional_to}{lambda}{sub 0}{sup 2}. This narrower spectrum makes measurement closer to the laser wavelength necessary. The design of the calibration technique presents a number of challenges. Some of these challenges are generic to all Thomson scattering systems. These include detecting a sufficient number of photoelectrons and designing filters that measure close to the laser wavelength while simultaneously achieving adequate blocking of the laser wavelength. An issue specific to LIDAR systems arises since the collection optics operates over a wide range of depth of field. This wide depth of field has the effect of changing the angle of light incident on the optical interference filter with plasma major radius. The angular distribution then determines the effective spectral transmission function of the interference filter and hence impacts on the accuracy of the absolute calibration. One method that can be used to increase absolute calibration accuracy is collecting both Stokes and anti-Stokes lines with optical filter transmission bands specifically designed to reduce systematic uncertainty.

43 PARTICLE ACCELERATORS↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cathode-fall of low-pressure hydrogen discharges: Absolute spectral emission and model

Absolute excitation probabilities from very low to moderate-current hydrogen discharges in parallel-plane geometry are measured and used to test models. Relative emission data are obtained for the H{sub {alpha}} line, the H{sub 2} (a{sup 3}{Sigma}{yields}b{sup 3}{Pi}) near-UV continuum, and the H{sub 2} (G{sup 1}{Sigma}{yields}B{sup 1}{Pi}{sub u}{sup +}) band at pressures of 0.5 and 2 Torr, a 1.05 cm gap, and voltages from 300 to 900 V. Electron behavior is traced using the first negative (A{sup 2}{Sigma}{sub g}{yields} X{sup 2}{Pi}{sub u}, {nu}'' = 0 {yields}{nu}' = 0) band of N{sub 2}{sup +} by adding 2% N{sub 2}. Relative measurements of H{sub {alpha}}, H{sub 2} near-UV, and N{sub 2} 1st negative emission are placed on a absolute scale by normalization to published measurements and Boltzmann calculations of electron excitation. Emission probabilities calculated using a multi-beam kinetics model for the electrons, H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, H{sup -}, H, and H{sub 2} are compared with the calibrated experiments. Fast H atoms are calculated to produce H{sub {alpha}} excitation that is comparable with that of electrons. The calculated emission intensities for H{sub {alpha}} and H{sub 2} near-UV continuum are within a factor of three of the absolute measurements for a range of 5000:1 in current and 4:1 in hydrogen pressure. Calculations at 2 Torr show that most of the space charge electric field responsible for the cathode fall is produced by H{sub 3}{sup +} ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute photoionization cross-section of the propargyl radical

Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute NMR shielding scales and nuclear spin–rotation constants in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br and {sup 127}I)

We present nuclear spin–rotation constants, absolute nuclear magnetic resonance (NMR) shielding constants, and shielding spans of all the nuclei in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br, {sup 127}I), calculated using coupled-cluster singles-and-doubles with a perturbative triples (CCSD(T)) correction theory, four-component relativistic density functional theory (relativistic DFT), and non-relativistic DFT. The total nuclear spin–rotation constants determined by adding the relativistic corrections obtained from DFT calculations to the CCSD(T) values are in general in agreement with available experimental data, indicating that the computational approach followed in this study allows us to predict reliable results for the unknown spin–rotation constants in these molecules. The total NMR absolute shielding constants are determined for all the nuclei following the same approach as that applied for the nuclear spin–rotation constants. In most of the molecules, relativistic effects significantly change the computed shielding constants, demonstrating that straightforward application of the non-relativistic formula relating the electronic contribution to the nuclear spin–rotation constants and the paramagnetic contribution to the shielding constants does not yield correct results. We also analyze the origin of the unusually large absolute shielding constant and its relativistic correction of gold in AuF compared to the other gold monohalides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thresholds of absolute two-plasmon-decay and stimulated Raman scattering instabilities driven by multiple broadband lasers

Here, thresholds for the absolute stimulated Raman scattering (SRS) and two-plasma decay (TPD) instabilities driven by multiple broadband laser beams are evaluated using 3-D simulations at conditions relevant to inertial confinement fusion experiments. Multibeam TPD and SRS backscatter are found to be easier to mitigate with bandwidth than the corresponding single-beam instabilities. A relative bandwidth of 1% increases the threshold for absolute SRS backscatter by a factor of 4 at conditions relevant to ongoing National Ignition Facility experiments and should be sufficient to keep all of the absolute instabilities below threshold in experiments with similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ABSOLUTE PROPERTIES OF THE ECCENTRIC ECLIPSING BINARY STAR FT ORIONIS

Accurate absolute properties are determined for the first time for the 3.15 day period eccentric eclipsing binary star FT Ori based on new absolute photometry, five differential light curves, and a radial velocity curve. The stars appear to be normal for their spectral types, A0 + A2. The orbit is highly eccentric (e = 0.409) and shows apsidal motion with a period of 536 years. The absolute properties and the degree of central mass concentration of the stars are consistent with current theoretical models at an age of 190 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

A strict test of stellar evolution models: The absolute dimensions of the massive benchmark eclipsing binary V578 Mon

We determine the absolute dimensions of the eclipsing binary V578 Mon, a detached system of two early B-type stars (B0V + B1V, P = 2.40848 days) in the star-forming region NGC 2244 of the Rosette Nebula. From the light curve analysis of 40 yr of photometry and the analysis of HERMES spectra, we find radii of 5.41 ± 0.04 R{sub ☉} and 4.29 ± 0.05 R{sub ☉}, and temperatures of 30,000 ± 500 K and 25,750 ± 435 K, respectively. We find that our disentangled component spectra for V578 Mon agree well with previous spectral disentangling from the literature. We also reconfirm the previous spectroscopic orbit of V578 Mon finding that masses of 14.54 ± 0.08 M{sub ☉} and 10.29 ± 0.06 M{sub ☉} are fully compatible with the new analysis. We compare the absolute dimensions to the rotating models of the Geneva and Utrecht groups and the models of the Granada group. We find that all three sets of models marginally reproduce the absolute dimensions of both stars with a common age within the uncertainty for gravity-effective temperature isochrones. However, there are some apparent age discrepancies for the corresponding mass-radius isochrones. Models with larger convective overshoot, >0.35, worked best. Combined with our previously determined apsidal motion of 0.07089{sub −0.00013}{sup +0.00021} deg cycle{sup –1}, we compute the internal structure constants (tidal Love number) for the Newtonian and general relativistic contribution to the apsidal motion as log k {sub 2} = –1.975 ± 0.017 and log k {sub 2} = –3.412 ± 0.018, respectively. We find the relativistic contribution to the apsidal motion to be small, <4%. We find that the prediction of log k {sub 2,theo} = –2.005 ± 0.025 of the Granada models fully agrees with our observed log k {sub 2}.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ABSOLUTE MAGNITUDES OF RED HORIZONTAL BRANCH STARS IN THE ugriz SYSTEM

Based on photometric data of the central parts of eight globular clusters and one open cluster presented by An and his collaborators, we select red horizontal branch (RHB) stars in the (g - r){sub 0}-g {sub 0} diagram and make a statistical study of the distributions of their colors and absolute magnitudes in the SDSS ugriz system. Meanwhile, absolute magnitudes in the Johnson VRI system are calculated through the translation formulae between gri and VRI in the literature. The calibrations of absolute magnitude as functions of metallicity and age are established by linear regressions of the data. It is found that metallicity coefficients in these calibrations decrease, while age coefficients increase, from the blue u filter to the red z filter. The calibration of M{sub i} = 0.06[Fe/H] + 0.040t + 0.03 has the smallest scatter of 0.04 mag, and thus i is the best filter in the ugriz system when RHB stars are used for distance indicators. The comparison of the M{sub I} calibration from our data with that from red clump stars indicates that the previous suggestion that the I filter is better than the V filter in distance determination may not be true because of its significant dependence on age.

79 ASTRONOMY AND ASTROPHYSICS↗

ABSOLUTE PHOTODETACHMENT CROSS-SECTION MEASUREMENTS FOR HYDROCARBON CHAIN ANIONS

Absolute photodetachment cross sections have been measured for the hydrocarbon chain anions C{sub n}H{sup -}, n = 2, 4, and 6, which are relevant for an understanding of molecular clouds in the interstellar medium. Data have been obtained for different photon energies within approximately 1 eV of the detachment threshold. With our recently developed method we have achieved a precision of better than 25% on these absolute cross sections. The experiments have been carried out by means of photodetachment tomography of the mass-selected molecular anions in a multipole radio-frequency ion trap. The measured absolute cross sections are in accordance with the empirical scaling law of Millar et al. and have allowed us to determine its free parameters. These results are important for predicting the photostability and thus the abundance of carbon chain anions in planetary atmospheres, in circumstellar envelopes, and in photon-dominated regions of interstellar molecular clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

STANDARDIZING TYPE Ia SUPERNOVA ABSOLUTE MAGNITUDES USING GAUSSIAN PROCESS DATA REGRESSION

We present a novel class of models for Type Ia supernova time-evolving spectral energy distributions (SEDs) and absolute magnitudes: they are each modeled as stochastic functions described by Gaussian processes. The values of the SED and absolute magnitudes are defined through well-defined regression prescriptions, so that data directly inform the models. As a proof of concept, we implement a model for synthetic photometry built from the spectrophotometric time series from the Nearby Supernova Factory. Absolute magnitudes at peak B brightness are calibrated to 0.13 mag in the g band and to as low as 0.09 mag in the z = 0.25 blueshifted i band, where the dispersion includes contributions from measurement uncertainties and peculiar velocities. The methodology can be applied to spectrophotometric time series of supernovae that span a range of redshifts to simultaneously standardize supernovae together with fitting cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON A NEW NEAR-INFRARED METHOD TO ESTIMATE THE ABSOLUTE AGES OF STAR CLUSTERS: NGC 3201 AS A FIRST TEST CASE

We present a new method to estimate the absolute ages of stellar systems. This method is based on the difference in magnitude between the main-sequence turnoff (MSTO) and a well-defined knee located along the lower main sequence (MSK). This feature is caused by the collisionally induced absorption of molecular hydrogen, and it can easily be identified in near-infrared (NIR) and in optical-NIR color-magnitude diagrams of stellar systems. We took advantage of deep and accurate NIR images collected with the Multi-Conjugate Adaptive Optics Demonstrator temporarily available on the Very Large Telescope and of optical images collected with the Advanced Camera for Surveys Wide Field Camera on the Hubble Space Telescope and with ground-based telescopes to estimate the absolute age of the globular NGC 3201 using both the MSTO and the {delta}(MSTO-MSK). We have adopted a new set of cluster isochrones, and we found that the absolute ages based on the two methods agree to within 1{sigma}. However, the errors of the ages based on the {delta}(MSTO-MSK) method are potentially more than a factor of 2 smaller, since they are not affected by uncertainties in cluster distance or reddening. Current isochrones appear to predict slightly bluer ({approx}0.05 mag) NIR and optical-NIR colors than observed for magnitudes fainter than the MSK.

79 ASTRONOMY AND ASTROPHYSICS↗

An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR{sub 20,10}) and it is therefore necessary to know the TPR{sub 20,10} to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and therefore measured the dose using a Farmer-type instrument (model NE 2571) as well. Results: We found the tomotherapy TPR{sub 20,10} value to be around 0.629, which is close to a 4 MV conventional linear accelerator value. During static irradiation, the secondary standard and the alanine dosimeters were compatible within 0.5%. The A1SL relative deviation to the secondary standard was 1.2% and the NE2571 relative deviation to the secondary standard was -1.7%. The measurement in dynamic helical mode found the different dosimeters compatible within 1.4% and the alanine dosimeters and the secondary standard were even found under 0.2%. Conclusions: We found that the different methods are all within uncertainties as well as globally coherent, and the specific limitations of the various dosimeters are discussed in order to help the medical physicist design an independent reference system. We demonstrated that, taking into account the particular reference conditions, one can use an ionization chamber calibrated for conventional linear accelerators to assert the absolute dose delivered by a tomotherapy accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗