Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Host galaxies of ultrastrong Mg ii absorbers at z ∼ 0.5

ABSTRACT From a sample of 109 candidate ultrastrong Mg ii (USMg ii; having rest equivalent width of Mg ii, W2796 > 3.0 Å) systems at z = 0.4–0.6, we confirm 27 and identify host galaxies of 20 systems based on associated nebular line emission from our SALT observations or from Sloan Digital Sky Survey (SDSS) fiber spectra. The measured impact parameter, [O ii] luminosity, star formation rate, B-band luminosity, and stellar mass are in the ranges 7.3 ≤ D[kpc] ≤ 79, $0.2\le L_{[\mathrm{ O}\,~\small {\rm II}]}[ 10^{41}~\mathrm{ erg} \mathrm{ s}^{-1}]\le 4.5$, 2.59 ≤ SFR[M⊙yr−1] ≤ 33.51, $0.15L_B^{*}\le L_B\le 1.63L_B^{*}$, and 10.21 ≤ log[M*/ M ⊙] ≤ 11.62, respectively. The impact parameters found are larger than that predicted by the W2796 versus D relationship of the general population of Mg ii absorbers. At a given D, USMg ii host galaxies are more luminous and massive compared to typical Mg ii absorbers. However, the measured SFRs are slightly lower than that of main-sequence galaxies with same M⋆ at z ∼ 0.5. We report a correlation between $L_{[\mathrm{ O}\,\small {\rm II}]}$ and W2796 for the full population of Mg ii absorbers, driven mainly by the host galaxies of weak Mg ii absorbers that tend to have low $L_{[\mathrm{ O}\,\small {\rm II}]}$ and large impact parameters. We find at least ∼33 per cent of the USMg ii host galaxies (with a limiting magnitude of mr < 23.6) are isolated and the large W2796 in these cases may originate from gas flows (infall/outflow) in single haloes of massive but not starburst galaxies. We also find galaxy interactions could be responsible for large velocity widths in at least ∼17 per cent cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband titanium nitride disordered metasurface absorbers

We experimentally demonstrate titanium nitride (TiN) broadband metasurface perfect absorbers by conformally coating plasmonic TiN films onto disordered anodic aluminum oxide (AAO) nanotemplates. The disordered metasurface absorbers exhibit polarization-insensitive and weak angle-dependent perfect absorption over the entire visible and near-infrared spectral regions (300 < λ < 2500 nm). We show from experimental results and numerical simulations that the light scattering induced by the strong disorder of the AAO nanopores and the strong absorption of the TiN deposited on their sidewall are of critical importance for achieving broadband perfect absorption. The TiN disordered metasurface perfect absorbers are superior to many other types of broadband perfect absorbers previously reported and are more suitable for practical applications especially in harsh environments. The device concept for broadband perfect absorption based on plasmonic metal-nitride film coated disordered dielectric media could potentially be extended to significantly enhance the efficiency of solar energy harvesting and the performance of hot-carrier based optoelectronics.

Chang, Chun-Chieh (ORCID:0000000337282454)↗

Distribution of U, Pu and Np in a Mo-99 Recovery Process using Sachtopore NP (titania based) Absorbent Material

A laboratory scale mockup of a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (U-238), plutonium (94% Pu-239), neptunium (Np-237), and non-radioisotopes of common fission products (including Mo). The goal of this work was to determine the amounts of U, Pu, and Np in the liquid waste streams created by the wash streams for the production process. The key question was how the initial acid wash volume will be handled, as this solution contains residual raffinate which amounted to ~ 3% ofthe mass ofthe feed solution in this experiment. If the initial 1.9 bed volumes (BV) of acid wash were recycled as in this experiment then the combined wash solutions can be expected to contain 0.4 g U/L, 2.7 pg Pu/L and < 14 pg Np/L. If, on the other extreme, the entire acid wash solution was discarded as waste, then the combined wash solutions can be expected to contain 11 g U/L, 3.8 pg Pu/L and ~ 80 pg Np/L. The Sachtopore NP absorbent (for Mo-99 recovery) retains a minuscule fraction ofthe U (2.3 mg U per g titania or 0.03% ofthe U in the feed). The uncertainties are too large to determine how close the absorbent is to saturation with U. Less mass but a higher fraction ofthe total Np was retained by the absorbent (0.7 pg Np per g titania or ~2% of the Np in the feed). As has been reported elsewhere, a large fraction ofthe Pu fed to the titania bed was retained by the absorbent (92% of Pu in the feed or 20 pg per g titania).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Absorbers seen near the Venus cloud tops from Pioneer Venus

Pioneer Venus Orbiter measurements of planetary contrast at the Venus cloud tops are discussed. Images of the cloud tops at wavelengths between 1990 and 3400 A were obtained by the Pioneer UV Spectrometer together with broadband imagery and polarimetry at 2700 and 3650 A from the Orbiter Cloud Photopolarimeter at Venus phase angles of 33 to 130 deg. The planet is found to be darkest at the point where the UV Spectrometer line of sight penetrates perpendicular to the cloud tops, indicating that the absorbing material must be deep in the atmosphere. The contrast observed at wavelengths shortward of 3200 A is explained by SO2 absorption in the dark regions, while the persistence of the contrast at longer wavelengths requires the presence of an additional absorber or absorbers closely associated with the SO2, and a haze of submicron particles overlying the cloud tops in the bright regions. The correlations found between contrast and polarization indicate that no single constituent or change in vertical structure can account for the UV contrast. The origin of the markings is instead explained by a model in which absorbers subject to photochemical destruction are mixed upward into the cloud top region.

Esposito, L. W.↗

Optimal design of a passive vibration absorber for a truss beam

The selection of the design parameters of passive vibration absorbers attached to a long cantilevered beam is studied. This study was motivated by the need for conducting parametric analysis of dynamics and control for Space-Shuttle-attached long beams. An optimization scheme using a quadratic cost function is introduced yielding the optimal sizing of the tip vibration absorber. Analytical solutions for an optimal absorber are presented for the case of one beam vibrational mode coupled with the absorber dynamics, and results are extended to cover the multiple mode case. An algorithm is developed to make an initial estimate of optimal tuning parameters which minimize the quadratic error cost function. Examples are given to illustrate the design concept.

Juang, J.-N.↗

Absorbent product and articles made therefrom

A multilayer absorbent product for use in contact with the skin to absorb fluids is described. The product has a water pervious facing layer for contacting the skin, and a first fibrous wicking layer overlaying the water pervious layer. A first container section is defined by inner and outer layers of a water pervious wicking material in between a first absorbent mass and a second container section defined by inner and outer layers of a water pervious wicking material between what is disposed a second absorbent mass, and a liquid impermeable/gas permeable layer overlaying the second fibrous wicking layer.

Dawn, F. S.↗

Development of 2 underseat energy absorbers for application to crashworthy passenger seats for general aviation aircraft

This report presents the methodology and results of a program conducted to develop two underseat energy absorber (E/A) concepts for application to nonadjustable crashworthy passenger seats for general aviation aircraft. One concept utilizes an inflated air bag, and the other, a convoluted sheet metal bellows. Prototypes of both were designed, built, and tested. Both concepts demonstrated the necessary features of an energy absorber (load-limiter); however, the air bag concept is particularly encouraging because of its light weight. Several seat frame concepts also were investigated as a means of resisting longitudinal and lateral loads and of guiding the primary vertical stroke of the underseat energy absorber. Further development of a seat system design using the underseat energy absorbers is recommended because they provide greatly enhanced crash survivability as compared with existing general aviation aircraft seats.

Warrick, J. C.↗

Techniques for measuring intercepted and absorbed PAR in corn canopies

The quantity of radiation potentially available for photosynthesis that is captured by the crop is best described as absorbed photosynthetically active radiation (PAR). Absorbed PAR (APAR) is the difference between descending and ascending fluxes. The four components of APAR were measured above and within two planting densities of corn (Zea mays L.) and several methods of measuring and estimating APAR were examined. A line quantum sensor that spatially averages the photosynthetic photon flux density provided a rapid and portable method of measuring APAR. PAR reflectance from the soil (Typic Argiaquoll) surface decreased from 10% to less than 1% of the incoming PAR as the canopy cover increased. PAR reflectance from the canopy decreased to less than 3% at maximum vegetative cover. Intercepted PAR (1 - transmitted PAR) generally overestimated absorbed PAR by less than 4% throughout most of the growing season. Thus intercepted PAR appears to be a reasonable estimate of absorbed PAR.

Gallo, K. P.↗

Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft, volume 1

A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is explored. An energy-absorbing test seat was designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions, was conducted at a sled test facility. Comparative tests with operational F-111 crewseats were also conducted. After successful dynamic testing of the seat, more testing was conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests were conducted. The vertical drop tests were used to obtain comparative data between the energy-absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series.

Shane, S. J.↗

Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 2: Data from seat testing

The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.

Shane, S. J.↗

Electromagnetic fields backscattered from an s-shaped inlet cavity with an absorber coating on its inner walls

The EM backscatter from a two-dimensional S-shaped inlet cavity is analyzed using three different techniques, namely a hybrid combination of asymptotic high frequency and modal methods, an integral equation method, and the geometrical optics ray method, respectively. This inlet has a thin absorber coating on its perfectly conducting inner walls and the planar interior termination is made perfectly conducting. The effect of the absorber on the inner wall is treated via a perturbation scheme in the hybrid approach where it is assumed that the loss is sufficiently small for the method to be valid. The results are compared with the backscatter from a straight inlet cavity to evaluate the effect of offsetting the termination in the S-bend configuration such that it is not visible from the open end of the inlet. The envelope of the backscatter pattern for the straight inlet is always seen to peak around the forward axis due to the large return from the directly visible termination, and the pattern envelope tapers off away from the forward axis. Offsetting the termination causes the envelope of the backscatter pattern to flatten out, thereby reducing the return near the forward axis by several dB. The absorber coating reduces the pattern level of the straight inlet in directions away from the forward axis but has little effect on the peak near the axis; furthermore, the absorber coating is seen to consistently reduce the backscatter from the S-bend inlet for almost all incidence angles. The hybrid method gives excellent agreement with experimental data and with the integral equation solution, whereas, the geometrical optics ray tracing method is able to generally predict the average of the bachscatter pattern but not the pattern details.

Burkholder, R. J.↗

Absorbing boundary conditions for second-order hyperbolic equations

A uniform approach to construct absorbing artificial boundary conditions for second-order linear hyperbolic equations is proposed. The nonlocal boundary condition is given by a pseudodifferential operator that annihilates travelling waves. It is obtained through the dispersion relation of the differential equation by requiring that the initial-boundary value problem admits the wave solutions travelling in one direction only. Local approximation of this global boundary condition yields an nth-order differential operator. It is shown that the best approximations must be in the canonical forms which can be factorized into first-order operators. These boundary conditions are perfectly absorbing for wave packets propagating at certain group velocities. A hierarchy of absorbing boundary conditions is derived for transonic small perturbation equations of unsteady flows. These examples illustrate that the absorbing boundary conditions are easy to derive, and the effectiveness is demonstrated by the numerical experiments.

Jiang, Hong↗

Production of self-absorbed synchrotron spectra steeper than nu to the 5/2

Self-absorbed synchrotron radiation produced by electrons with a power-law distribution of energies has a unique spectral shape: intensity is proportional to nu to the 5/2, where nu is the frequency, irrespective of the power law index of the electrons. It has been asserted that the measurement of a spectral index greater than 5/2 at frequencies below the 'far-IR turnovers' observed in the spectra of many radio-quiet AGN is incompatible with the physics of self-absorbed synchrotron sources. It is shown here that plausible electron energy distributions can lead to self-absorbed synchrotron spectra which are steeper than nu to the 5/2 over 1-1.5 orders of magnitude in frequency. This indicates that none of the existing observations are in fact incompatible with self-absorbed synchrotron radiation as the source.

De Kool, Martijn↗

Absorbing boundary conditions for second-order hyperbolic equations

A uniform approach to construct absorbing artificial boundary conditions for second-order linear hyperbolic equations is proposed. The nonlocal boundary condition is given by a pseudodifferential operator that annihilates travelling waves. It is obtained through the dispersion relation of the differential equation by requiring that the initial-boundary value problem admits the wave solutions travelling in one direction only. Local approximation of this global boundary condition yields an nth-order differential operator. It is shown that the best approximations must be in the canonical forms which can be factorized into first-order operators. These boundary conditions are perfectly absorbing for wave packets propagating at certain group velocities. A hierarchy of absorbing boundary conditions is derived for transonic small perturbation equations of unsteady flows. These examples illustrate that the absorbing boundary conditions are easy to derive, and the effectiveness is demonstrated by the numerical experiments.

Jiang, Hong↗

Optimal active vibration absorber: Design and experimental results

An optimal active vibration absorber can provide guaranteed closed-loop stability and control for large flexible space structures with collocated sensors/actuators. The active vibration absorber is a second-order dynamic system which is designed to suppress any unwanted structural vibration. This can be designed with minimum knowledge of the controlled system. Two methods for optimizing the active vibration absorber parameters are illustrated: minimum resonant amplitude and frequency matched active controllers. The Controls-Structures Interaction Phase-1 Evolutionary Model at NASA LaRC is used to demonstrate the effectiveness of the active vibration absorber for vibration suppression. Performance is compared numerically and experimentally using acceleration feedback.

Lee-Glauser, Gina↗

Optimal active vibration absorber - Design and experimental results

An optimal active vibration absorber can provide guaranteed closed-loop stability and control for large flexible space structures with collocated sensors/actuators. The active vibration absorber is a second-order dynamic system which is designed to suppress any unwanted structural vibration. This can be designed with minimum knowledge of the controlled system. Two methods for optimizing the active vibration absorber parameters are illustrated: minimum resonant amplitude and frequency matched active controllers. The Controls-Structures Interaction Phase-1 Evolutionary Model at NASA LaRC is used to demonstrate the effectiveness of the active vibration absorber for vibration suppression. Performance is compared numerically and experimentally using acceleration feedback.

Lee-Glauser, Gina↗

Dynamic testing of airplane shock-absorbing struts

Measurement of perpendicular impacts of a landing gear with different shock-absorbing struts against the drum testing stand. Tests were made with pneumatic shock absorbers having various degrees of damping, liquid shock absorbers, steel-spring shock absorbers and rigid struts. Falling tests and rolling tests. Maximum impact and gradual reduction of the impacts in number and time in the falling tests. Maximum impact and number of weaker impacts in rolling tests.

Langer, P↗