Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Thermal Testing Quality Assurance of 24LCC & 3LCC Electronic Packages

The purpose of this project is to experimentally validate the thermal fatigue life of solder interconnects for a variety of surface mount electronic packages. Over the years, there has been a significant amount of research and analysis in the fracture of solder joints on printed circuit boards. Solder is important in the mechanical and electronic functionality of the component. It is important throughout the life of the product that the solder remains crack and fracture free. The specific type of solder used in this experiment is a 63Sn37Pb eutectic alloy. Each package was manufactured with conformal coating along with and without an underfill material below the device. Conformal coating helps protect the board from environments such as electrostatic discharge and humidity. It is commonly used in broad types of engineering disciplines such as commercial, military, research and development, etc. Conformal coating can also pose a risk for the life of the board because of its high thermal expansion coefficient. This can greatly decrease the life of the product if it regularly sees high temperature variations. This leads to a shorter fatigue life of the solder. The fatigue life is a common mechanical problem in the field of electronic devices. Adding underfill can help increase the fatigue life of the solder. However, applying underfill adds time to manufacturing and production. This ultimately increases the cost per unit. The study of conformal coated printed circuit boards with and without underfill was done on two different surface mount electronic packages. The electronic packages studied were 24 and 3 contact Leadless Ceramic Chips packages. When the package was not underfilled, the coating was allowed to flow underneath. The assembly was analyzed and tested to obtain the best available combination of conformal coating, underfill, and potting to design the most robust and reliable circuit board while keeping in mind certain factors such as cost, manufacturing time, and need. Different types of conformal coatings were considered with and without underfill for each device. 29 of each component were manufactured to have a large sample size and for the sake of individual defects and imperfections. Finite Element Analysis (FEA) was performed by an engineer at Sandia National Laboratories for both Leadless Ceramic Chips. From the FEA results, a test acceleration profile was derived and the number of temperature cycles to fail the solder interconnects were found for three different cases. Experimentation was done as a secondary measure to validate this data to show confidence in the theoretical analysis. Accelerated testing functions as a quality check for the product. Accelerated testing is extremely useful in the research and development phase of engineering. It can save money from the potential of early life defects and the costs that come along with warranties. Accelerated testing makes a weaker design more robust and checks the reliability of a strong design in a shorter period of time. It is extremely helpful in a world where deliverables are in high demand and scheduling is tight. Accelerated testing helps the engineer gain an understanding of what needs to be improved and what works well. There are many different types of accelerated tests. Our circuit boards were accelerated inside a closed thermal chamber because of the high number of use cycles. The ultimate goal of this experimentation is to help identify what will prevent any premature cracking or fracturing in the solder alloy. It is important to understand that underfilling each component may or may not be needed. If underfill is not needed, there are several production benefits.

42 ENGINEERING↗

A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

The Advanced Test Reactor (ATR) has been used successfully for the testing of fast reactor fuel for nearly two decades. These successes have been in spite of numerous challenges for testing fast reactor fuel in the ATR (a thermal spectrum reactor), but the solutions to those challenges have resulted in excessively long irradiation times (~10 years) for high-burnup targets as well as experiments that are highly sensitive to fabrication tolerances and eccentricities. This paper presents a solution to the problems of extended irradiation times and fabrication sensitivities. Thermal and neutronic analyses were performed to show that a reduced-diameter fuel pin with an equivalent linear heat generation rate can provide a prototypic thermal profile (peak centerline and inner clad temperature) along with a near-prototypic power profile within the ATR thermal spectrum. This allows the experiment to reach a high burnup in an expeditious timeframe compared to traditional ATR fast fuel irradiations. In addition, problems with fabrication sensitivities were addressed by introducing a double-encapsulated experiment that pushes the high heat flux helium gap farther away from the fuel pin. Fuel pin position eccentricities are also mitigated by using a large sodium bond between the pin and capsule fuel. The advantages and potential pitfalls of this revised design are discussed, including the effect of length scales on fuel system behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

Permanent magnets for the return loop of the Cornell-Brookhaven energy recovery linac test accelerator

214 neodymium permanent magnets have been manufactured for the return loop of the CBETA multi-turn ERL at Cornell University. There are 5 types of quadrupole and combined-function gradient magnets using a variant of the circular Halbach design. These are made out of NdFeB material and glued into an aluminium housing with water channels for temperature stabilisation. The NdFeB wedges and magnet construction were done by outside companies, while the final “tuning” using inserts containing 64 iron rods per magnet was done at BNL over a period of about 6 months. Average relative field errors of 2.2×10 -4 were achieved on the beam region. The magnet strengths vary by type but are of order 10 T/m for quadrupole component and up to 0.3 T for the dipole. This paper reports on the field quality and timeline achieved in this production process

43 PARTICLE ACCELERATORS↗